1.A comparative study based on the mandibular movement track and the movement parameters of the virtual articulator in simulating occlusal adjustment.
Liya MA ; Jiarui CHAO ; Fei LIU ; Jiansong MEI ; Jiefei SHEN
West China Journal of Stomatology 2023;41(3):254-259
OBJECTIVES:
This study aimed to compare the effects of virtual adjustment on occlusal interferences in mandibular posterior single crown and three-unit bridge restorations by using the mandibular movement track and the movement parameters of a virtual articulator.
METHODS:
Twenty-two participants were recruited. Digital casts of the maxillary and mandibular arches were obtained using an intraoral scanner, and the jaw registration system was used to record the data of the mandibular movement track and the movement parameters of the articulator. Four kinds of restorations with 0.3 mm occlusal interferences were designed with dental design software. In particular, single crowns were designed for teeth 44 and 46, whereas three-unit bridges were designed for teeth 44-46 and 45-47, and the corresponding natural teeth were virtually extracted. Virtual adjustment of the restorations was performed using two dynamic occlusal recordings, namely, the mandibular movement track and the movement parameters of the virtual articulator. A reverse-engineering software was used to measure the root-mean-square of the three-dimensional deviation of the occlusal surfaces between natural teeth and the adjusted restorations. The differences between the two methods of virtual-occlusion adjustment were compared and analyzed.
RESULTS:
For the same group of restorations, the three-dimensional deviation of the mandibular movement track group were lower than those of the virtual articulator group, and the differences were statistically significant (P<0.05). For the four groups of restorations adjusted by the same method, the three-dimensional deviation of the 46-tooth single crown was the largest and the smallest three-dimensional deviation was that of the 44-tooth single crown. Statistical differences existed between the 44-tooth single crown and the other groups (P<0.05).
CONCLUSIONS
For the occlusal design of posterior single crown and three-unit bridge, the mandibular movement track could be a more effective approach to virtual occlusal adjustment than the movement parameters of the virtual articulator.
Humans
;
Mouth, Edentulous
;
Occlusal Adjustment
;
Jaw Relation Record
;
Dental Articulators
;
Software
2.A clinical application study of digital manufacturing simple intraoral Gothic arch-tracing device in determining the centric relation of complete dentures.
Tuan Feng ZHOU ; Xue YANG ; Rui Jie WANG ; Ming Xuan CHENG ; Hua ZHANG ; Jin Qi WEI
Journal of Peking University(Health Sciences) 2023;55(1):101-107
OBJECTIVE:
To verify the consistency between the digital manufacturing simple intraoral Gothic arch-tracing device and the traditional intraoral Gothic arch-tracing device in determining the centric relation of complete dentures restoration.
METHODS:
Ten outpatients with edentulous jaws were selec-ted, and the centric relation of the patients was determined by digital manufacturing of simple intraoral Gothic arch-tracing device (T1) and traditional intraoral Gothic arch-tracing device (T2); the difference of clinical operation time between the two methods was recorded; the upper and lower edentulous jaw plaster models were scanned with two kinds of centric relation, the Standard Triangle Language (STL) files imported into Geomagic studio software to apply the best fitting of multiple points of the both upper jaw models, the fitted STL files imported into the 3 shape viewer software, and the maximum position deviations of the vertical, labial (buccal) and lingual directions of the mandibular midline area and molar areas in T1 and T2 groups measured. During the clinical complete dentures try-in, we observed whether there was midline deviation in the mouth of T1 group and T2 group, and whether the occlusion of posterior teeth was stable or not.
RESULTS:
The mean time spent on determining the centric relation of T1 and T2 groups was (41.90±2.64) min, (57.50±2.37) min respectively. Paired t test was conducted in the two groups, P < 0.01 with significant statistical difference; The mean maximum position deviation between T1 group and T2 group of the midline mandibular region in labial lingual direction was (0.32±0.14) mm, that was (0.40±0.23) mm in vertical direction; the mean maximum position deviation of molar area in buccal lingual direction was (0.35±0.23) mm and that was (0.33±0.20) mm in vertical direction. In the vertical and horizontal directions, the maximum position deviation of mandibles between group T1 and group T2 was controlled within 0.5 mm. In the process of clinical complete dentures try-in, there was no deviation from the center line of dentures. There was not warping, swinging and other poor stability phenomena in T1 and T2 groups.
CONCLUSION
The digital manufacturing of simple intraoral Gothic arch-tracing device can be used to determine the centric relation of complete dentures, which can not only save time of clinical operation, but also ensure the accuracy of the centric relation.
Humans
;
Centric Relation
;
Jaw Relation Record/methods*
;
Denture, Complete
;
Mouth, Edentulous
;
Jaw, Edentulous
3.Accuracy of intercuspal occlusion in 3D reconstruction with the dental articulator position method.
Lin Lin LI ; Yi Jiao ZHAO ; Hu CHEN ; Yong WANG ; Yu Chun SUN
Journal of Peking University(Health Sciences) 2020;52(1):138-143
OBJECTIVE:
To evaluate the three-dimensional (3D) reconstruction accuracy of the intercuspal occlusion (ICO) of the dental casts, by the dental articulator position method, and provide a reference for clinical application.
METHODS:
The standard dental casts in ICO were mounted on average values articulator, and five pairs of milling resin cylinders were respectively attached to the base of both the casts. 100 μm articulating paper and occlusal record silicone rubber were used to detect the occlusal contact number between the posterior teeth of casts mounted on articulator in ICO. The occlusal contact numbers NA detected by the two methods were calculated simultaneously, as the reference. After the upper and lower casts were scanned separately, and the buccal data of casts in ICO were scanned with the aid of the dental articulator position, registration was carried out utilizing the registration software. Then the digital casts mounted in ICO as well as the buccal occlusal data were saved in standard tessellation language (STL) format. Geomagic Studio 2013 software was used to analyze the contact number NS between digital upper and lower casts by the "deviation analysis" function. The differences were compared between NS and NA, to evaluate the sensitivity and positive predict value (PPV) of the model scanner to reproduce the occlusal contact with the aid of dental articulator position. The distance DR between the centers of the circles at the top surface of the upper and lower corresponding cylinders was obtained by the three-coordinate measuring system Faro Edge, as the reference value. The Geomagic Studio 2013 software was used to construct the cylinders of digital casts and the distance DM between the centers of the circles at the top surface of the corresponding cylinders were measured, as the test value. The one-sample T test was used to analyze the variable differences between DM and DR.
RESULTS:
The PPV of reproducing the occlusal contact point was 0.76 and sensitivity was 0.81. The distance error of the opposite cylinder was (0.232±0.089) mm. There was no statistical difference between the feature points 5-5', while there were statistical differences between the other feature points.
CONCLUSION
By the dental articulator position method, the model scanner reproduces the occlusal contact point with high sensitivity and PPV, and that meets clinical needs. Meanwhile, the distance between the feature points is greater than the reference value, which will lead to occlusal disturbance, and require clinical grinding.
Dental Articulators
;
Dental Occlusion
;
Imaging, Three-Dimensional
;
Jaw Relation Record
;
Models, Dental
;
Software
4.Method and accuracy of determining the jaw position of repositioning splint with the aid of digital technique.
Shuo Bo FANG ; Guang Ju YANG ; Yan Feng KANG ; Yu Chun SUN ; Qiu Fei XIE
Journal of Peking University(Health Sciences) 2020;53(1):76-82
OBJECTIVE:
To establish the workflow of determining the jaw position of repositioning splint with the aid of digital technique, and to evaluate the accuracy of this workflow and compare the accuracy of raising different vertical dimensions in vitro.
METHODS:
A volunteer was recruited. The data of full-arch scans, cone beam computed tomography (CBCT) image and ultrasonic jaw motion tracking of the volunteer were acquired. The full-arch scans were merged with the CBCT image, which were then matched to the jaw motion tracking reference system. The jaw position of repositioning splint was determined when the anterior teeth opening was 3 mm and the condyle was in centric relation of the fossa in the sagittal plane. A digital repositioning splint was designed in the software based on virtual articulator and fabricated with additive manufacturing technique. After the splint was tried in, another CBCT image was taken and a qualitative analysis was conducted to compare the position of condyle between these two CBCT images. In the in vitro study, standard dental plaster casts with resin ball markers attached to the base were mounted onto a fully adjustable articulator in the intercuspal position. The dental casts were scanned by an extraoral scanner to establish digital models. The ultrasonic jaw motion tracking device was used to obtain simulated jaw movements on the articulator, which was repeated for three times. The digital models and data of jaw movements were merged in one coordination with the aid of bite forks. The jaw position of repositioning splint was determined by adjusting data of jaw movements, each of which was used to determine three vertical jaw positions 4 mm, 5 mm, and 6 mm with the horizontal jaw position of protrusion 2 mm. The virtual articulators with differently adjusted jaw movements were applied in designing repositioning splints, and the final repositioning splints and virtual jaw relationships were exported in STL format. Then the repositioning splints were fabricated with additive manufacturing technique and tried in plaster casts on the mechanical articulator, which were scanned and the jaw relationships on the mechanical articulator were exported later. The virtual jaw relationships and scanned jaw relationships were registered according to lower models and displacement of upper models was calculated. Ball markers were fit to acquire the coordinates of centers and absolute difference values of centers along three coordinating axes X, Y, and Z were calculated. One-way analysis of variance was conducted using SPSS 18.0 software to compare deviations of the three different vertical jaw relationships in two-side test and the significance level was 0.05.
RESULTS:
With the aid of multi-source data fusion and individualized jaw motion, the clinical workflow of determining jaw position of repositioning splint was preliminarily established. The designed jaw position was realized on the right and the condyle was more inferior than the designed position on the left. Both displacement of the upper models and absolute difference values of centers showed no significant differences (P>0.05) in different vertical jaw dimensions. The displacement of the upper models was (0.25±0.04) mm. The absolute difference values of centers along the three coordinating axes X, Y, and Z were respectively (0.08±0.01) mm, (0.30±0.02) mm, and (0.21±0.04) mm.
CONCLUSION
A novel method of determining the jaw position of repositioning splint with the aid of digital technique is established. It is proved to be feasible by try-in after multi-data fusion, computer-aided design and computer-aided manufacturing. As is shown in vitro, it is accurate to apply this method in adjusting jaw position. Further clinical trial will be designed to evaluate its clinical effect.
Computer-Aided Design
;
Cone-Beam Computed Tomography
;
Dental Articulators
;
Humans
;
Jaw Relation Record
;
Occlusal Splints
;
Software
;
Splints
5.Full mouth rehabilitation using removable prosthesis of patient with unstable mandible movements: A case report
Dong Hwan SOHN ; Yang Jin YI ; Deuk Won JO
The Journal of Korean Academy of Prosthodontics 2020;58(1):35-41
Patients with collapsed occlusal support and unilateral chewing show parafunctional mandibular movements, which can be complicated in older patients. Gothic arch tracing and split cast technique are used to confirm the deviation between centric relation and anterior habitual bite in patient who has oral dyskinesia and collapsed occlusion. Temporary denture as occlusal stabilization appliance was provided for stable occlusion and reproducible mandibular movement. Definitive denture was fabricated by lingualized occlusion concept.
Centric Relation
;
Dentures
;
Humans
;
Mandible
;
Mastication
;
Mouth Rehabilitation
;
Mouth
;
Movement Disorders
;
Prostheses and Implants
6.Research progress on the relationship between centric relation and orthodontic treatment.
Dian JING ; Yu SHEN ; Pu YANG ; Zhi-He ZHAO
West China Journal of Stomatology 2019;37(5):527-532
Centric relation (CR) is one of the core research contents in orthodontics, prosthodontics, and gnathology, acting as an important physiological factor in reconstructing the occlusion and adjusting the occlusal relationship. For over a century, CR is still a controversial subject in dentistry. CR has been redefined for several times, and recently, its application has been widened in orthodontics, including orthodontic diagnosis, clinical examination and analysis, and treatment goals. The purpose of this article is to review the definition of CR, its relationship with malocclusion, and the application of this relationship in orthodontic treatment.
Centric Relation
;
Dental Care
;
Dental Occlusion, Centric
;
Humans
;
Malocclusion
;
Orthodontics, Corrective
7.Maxillary anterior prosthetic treatment concerning anterior guidance of a patient who lost stable holding contact
The Journal of Korean Academy of Prosthodontics 2019;57(4):467-474
Recently, many patients undergo anterior prosthetic treatment for esthetic reasons. In some patients complain about functional reasons such as inaccurate pronunciation and occlusal discomfort after the treatment. Anterior teeth are important esthetically but in the occlusal point of view, anterior guidance is the second most important factor in occlusion, next to centric relation. Failure to determine an appropriate anterior guidance might lead to posterior occlusal interference, which can highly affect the stability of the posterior teeth. Also, discomfort might occur if the customized interior guidance is not in harmony with the patient's envelope of function. The patient in this case complained of overall discomfort in the maxillary anterior area after prosthetic treatment. The expressed difficulty in pronunciation, unstable occlusion due to lack of stable holding contact and discomfort of the facial muscles. Maxillary anterior prostheses were refabricated through systematic diagnosis and treatment and thus, this case presents esthetical and functional satisfaction to both the patient and the dentist.
Centric Relation
;
Dentists
;
Diagnosis
;
Facial Muscles
;
Humans
;
Prostheses and Implants
;
Tooth
8.Full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to tooth wear
Hyun Seok CHAE ; Bo Seul JEON ; Jung Jin LEE ; Seung Geun AHN ; Jae Min SEO
The Journal of Korean Academy of Prosthodontics 2019;57(4):405-415
Excessive tooth wear can cause irreversible damage to the occlusal surface and can alter the anterior occlusal relationship by destroying the structure of the anterior teeth needed for esthetics and proper anterior guidance. The anterior deep bite is not a morbid occlusion by itself, but it may cause problems such as soft tissue trauma, opposing tooth eruption, tooth wear, and occlusal trauma if there are no stable occlusal contacts between the lower incisal edge against its upper lingual surface. The most important goal of treatment is to form stable occlusal contact in centric relation. In this case report, patients with decrease in vertical dimension and anterior deep bite due to maxillary posterior tooth loss and excessive tooth wear were treated full mouth rehabilitation with increased vertical dimension to regain the space for restoration and improve anterior occlusal relationship and esthetics. The functional and aesthetic problems of the patient could be solved by the equal intensity contact of all the teeth in centic relation (CR), anterior guidance in harmony with the functional movement, and restoration of the wear surface beyond the enamel range.
Centric Relation
;
Dental Enamel
;
Esthetics
;
Humans
;
Mouth Rehabilitation
;
Mouth
;
Overbite
;
Tooth Eruption
;
Tooth Loss
;
Tooth Wear
;
Tooth
;
Vertical Dimension
9.Restoration of patient accelerating anterior teeth wear by loss of posterior support: Case report
The Journal of Korean Academy of Prosthodontics 2019;57(4):382-388
Increased anterior teeth mastication following posterior teeth loss leads to greater anterior occlusal force. It may cause greater attrition of anterior teeth, traumatic force occlusion (TFO), also often followed by antagonist extrusion and occlusal disharmony. This clinical report describes the treatment for a 67-year-old female patient diagnosed with loss of both maxillary and left mandibular posterior teeth, severe attrition of maxillary and mandibular anterior teeth and extrusion of multiple teeth. A diagnostic cast was mounted on articular in centric relation (CR) position to evaluate vertical dimension (VD) and interspace. To provide adequate space for the prosthetic reconstructions, VD was increased by 3 mm on the anterior pin. And then diagnostic wax-up was completed upon that VD. Wax-up was converted to provisional restorations and verified in the patient's mouth and the final restorations were delivered. Clinical follow up examination held 3 months after temporary restoration owing to changes in vertical dimension revealed proper function in mastication without evidence of temporo-mandibular joint (TMJ) disorders. This clinical report presents successfully restoring severe attrition case with increasing vertical dimension resulting in satisfaction in esthetics and function.
Aged
;
Bite Force
;
Centric Relation
;
Esthetics
;
Female
;
Follow-Up Studies
;
Humans
;
Joints
;
Mastication
;
Mouth
;
Tooth
;
Vertical Dimension
10.Accuracy comparison of buccal bite scans by five intra-oral scanners
Ji Man PARK ; Jin JEON ; Seong Joo HEO
Journal of Dental Rehabilitation and Applied Science 2018;34(1):17-31
PURPOSE: The purpose of this study was to investigate the accuracy of the interocclusal relationship between upper and lower teeth according to the buccal interocclusal record scan using various intraoral scanner systems. MATERIALS AND METHODS: The upper and lower full arch Models with normal occlusion were scanned with 5 intraoral scanners (Cerec Omnicam, CS3500, iTero, Trios, True Definition). Buccal interocclusal record scan was taken only at the left side while occlusion was intentionally raised by 1 mm, 2 mm, 3 mm, and 4 mm with metal cylinder core embedded within polyvinylsiloxane bite registration material at the right molar region. The superimposition analysis was done to evaluate overall three-dimensional deviation and cross-section analysis was done to evaluate the degree and the direction of deviation of interocclusal relationship. RESULTS: From the superimposition study, Cerec Omnicam showed the least deviation (165.5 µm) and CS3500 (369.0 µm) showed the largest (P < 0.01). And the deviation was greater in 3, 4, 2 mm group than 1 mm (P < 0.01). From the cross-section study, Cerec Omnicam showed the farthest deviation (−242.8 µm) and CS3500 showed the closest deviation (312.5 µm) and a significantly high value was shown in 3 mm group. CONCLUSION: Every intraoral scanner has different accuracy in reproducing interocclusal relationship.
Intention
;
Jaw Relation Record
;
Molar
;
Tooth

Result Analysis
Print
Save
E-mail