1.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
2.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
3.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
4.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
5.Simulating the effects of reducing transfer latency from the intensive care unit on intensive care unit bed utilization in a Korean Tertiary Hospital
Jaeyoung CHOI ; Song-Hee KIM ; Ryoung-Eun KO ; Gee Young SUH ; Jeong Hoon YANG ; Chi-Min PARK ; Joongbum CHO ; Chi Ryang CHUNG
Acute and Critical Care 2025;40(1):18-28
Background:
Latency in transferring patients from intensive care units (ICUs) to general wards impedes the optimal allocation of ICU resources, underscoring the urgency of initiatives to reduce it. This study evaluates the extent of ICU transfer latency and assesses the potential benefits of minimizing it.
Methods:
Transfer latency was measured as the time between the first transfer request and the actual ICU discharge at a single-center tertiary hospital in 2021. Computer-based simulations and cost analyses were performed to examine how reducing transfer latency could affect average hourly ICU bed occupancy, the proportion of time ICU occupancy exceeds 80%, and hospital costs. The first analysis evaluated all ICU admissions, and the second analysis targeted a subset of ICU admissions with longer transfer latency, those requiring infectious precautions.
Results:
A total of 7,623 ICU admissions were analyzed, and the median transfer latency was 5.7 hours. Eliminating transfer latency for all ICU admissions would have resulted in a 32.8% point decrease in the proportion of time ICU occupancy exceeded 80%, and a potential annual savings of $6.18 million. Eliminating transfer latency for patients under infectious precautions would have decreased the time ICU occupancy exceeded 80% by 13.5% points, and reduced annual costs by a potential $1.26 million.
Conclusions
Transfer latency from ICUs to general wards might contribute to high ICU occupancy. Efforts to minimize latency for all admissions, or even for a subset of admissions with particularly long transfer latency, could enable more efficient use of ICU resources.
6.A survey of current practices in post-polypectomy surveillance in Korea
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Eun Ran KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ;
Intestinal Research 2024;22(2):186-207
Background/Aims:
We investigated the clinical practice patterns of post-polypectomy colonoscopic surveillance among Korean endoscopists.
Methods:
In a web-based survey conducted between September and November 2021, participants were asked about their preferred surveillance intervals and the patient age at which surveillance was discontinued. Adherence to the recent guidelines of the U.S. Multi-Society Task Force on Colorectal Cancer (USMSTF) was also analyzed.
Results:
In total, 196 endoscopists completed the survey. The most preferred first surveillance intervals were: a 5-year interval after the removal of 1–2 tubular adenomas < 10 mm; a 3-year interval after the removal of 3–10 tubular adenomas < 10 mm, adenomas ≥ 10 mm, tubulovillous or villous adenomas, ≤ 20 hyperplastic polyps < 10 mm, 1–4 sessile serrated lesions (SSLs) < 10 mm, hyperplastic polyps or SSLs ≥ 10 mm, and traditional serrated adenomas; and a 1-year interval after the removal of adenomas with highgrade dysplasia, >10 adenomas, 5–10 SSLs, and SSLs with dysplasia. In piecemeal resections of large polyps ( > 20 mm), surveillance colonoscopy was mostly preferred after 1 year for adenomas and 6 months for SSLs. The mean USMSTF guideline adherence rate was 30.7%. The largest proportion of respondents (40.8%–55.1%) discontinued the surveillance at the patient age of 80–84 years.
Conclusions
A significant discrepancy was observed between the preferred post-polypectomy surveillance intervals and recent international guidelines. Individualized measures are required to increase adherence to the guidelines.
7.Pediatric Extracorporeal Membrane Oxygenation in Korea: A Multicenter Retrospective Study on Utilization and Outcomes Spanning Over a Decade
Yu Hyeon CHOI ; Won Kyoung JHANG ; Seong Jong PARK ; Hee Joung CHOI ; Min-su OH ; Jung Eun KWON ; Beom Joon KIM ; Ju Ae SHIN ; In Kyung LEE ; June Dong PARK ; Bongjin LEE ; Hyun CHUNG ; Jae Yoon NA ; Ah Young CHOI ; Joongbum CHO ; Jaeyoung CHOI ; Hwa Jin CHO ; Ah Young KIM ; Yu Rim SHIN ; Joung-Hee BYUN ; Younga KIM
Journal of Korean Medical Science 2024;39(3):e33-
Background:
Over the last decade, extracorporeal membrane oxygenation (ECMO) use in critically ill children has increased and is associated with favorable outcomes. Our study aims to evaluate the current status of pediatric ECMO in Korea, with a specific focus on its volume and changes in survival rates based on diagnostic indications.
Methods:
This multicenter study retrospectively analyzed the indications and outcomes of pediatric ECMO over 10 years in patients at 14 hospitals in Korea from January 2012 to December 2021. Four diagnostic categories (neonatal respiratory, pediatric respiratory, postcardiotomy, and cardiac-medical) and trends were compared between periods 1 (2012–2016) and 2 (2017–2021).
Results:
Overall, 1065 ECMO runs were performed on 1032 patients, with the annual number of cases remaining unchanged over the 10 years. ECMO was most frequently used for post-cardiotomy (42.4%), cardiac-medical (31.8%), pediatric respiratory (17.5%), and neonatal respiratory (8.2%) cases. A 3.7% increase and 6.1% decrease in pediatric respiratory and post-cardiotomy cases, respectively, were noted between periods 1 and 2.Among the four groups, the cardiac-medical group had the highest survival rate (51.2%), followed by the pediatric respiratory (46.4%), post-cardiotomy (36.5%), and neonatal respiratory (29.4%) groups. A consistent improvement was noted in patient survival over the 10 years, with a significant increase between the two periods from 38.2% to 47.1% (P = 0.004). Improvement in survival was evident in post-cardiotomy cases (30–45%, P = 0.002).Significant associations with mortality were observed in neonates, patients requiring dialysis, and those treated with extracorporeal cardiopulmonary resuscitation (P < 0.001). In pediatric respiratory ECMO, immunocompromised patients also showed a significant correlation with mortality (P < 0.001).
Conclusion
Pediatric ECMO demonstrated a steady increase in overall survival in Korea;however, further efforts are needed since the outcomes remain suboptimal compared with global outcomes.
8.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.
9.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
10.The Accuracy of Implant Placement According to the Height of the Surgical Guide Hole
Kyu Won PARK ; Jihun CHA ; Seunggon JUNG ; Min‑Suk KOOK ; Hong-Ju PARK ; Hee-Kyun OH ; Jaeyoung RYU
Journal of Korean Dental Science 2024;17(4):201-209
Purpose:
This study investigated the impact of the guide hole height on the accuracy of implant placement using CAD/ CAM-fabricated surgical guides in resin models. The hypothesis is that decreasing the height of the guide hole reduces placement accuracy.
Materials and Methods:
Ten identical partially edentulous maxillary models were each fitted with surgical guides featuring guide hole heights of 1 mm, 3 mm, and/or 5 mm. Using a surgical guide and drill kit, implants were placed in six predetermined sites per model. Placement accuracy was evaluated by comparing the actual implant positions with the planned positions using digital scanning and computer software analysis. Statistical analyses were performed using ANOVA and Kruskal-Wallis tests to determine the significance of deviations at both the coronal and apical positions.
Results:
The average deviations were 0.75±0.33 mm at the coronal position and 1.10±0.51 mm at the apical position. Placement accuracy didnot differ with different guide hole heights. Additionally, errors were consistent regardless of the guide hole height and were not influenced by the type of support or the implant placement site.
Conclusion
In this rotro study, varying the height of the guide hole did not significantly affect the accuracy of implant placement. The results suggest that guide hole height within the tested range does not have a substantial impact on placement errors. Our findings indicate that factors other than the guide holeheight may play a more critical role in implant placement accuracy.

Result Analysis
Print
Save
E-mail