1.Eyeball Donation and Management System
Jaeyoung KIM ; Chul Young CHOI ; Jae Yong KIM ; Roo Min JUN ; Eun Chul KIM ; Yong-Soo BYUN ; Jong Hwa JUN ; Dong Hyun KIM ; Yunjin LEE ; Hyung Keun LEE ; Mee Kum KIM
Journal of the Korean Ophthalmological Society 2026;67(2):33-46
Purpose:
To propose improvements for promoting eyeball donation and managing donated corneas, this study analyzed the current system in Korea and reviewed relevant Korean laws, international standards, and foreign practices.
Methods:
To understand the current situation in Korea, annual reports published by the Korean Network for Organ Sharing and existing Korean laws were examined. For the international context, references were made to the National Organ Transplant Act, 21 CFR Part 1271 (Code of Federal Regulations Title 21 Part 1271), Current Good Tissue Practice guidelines of the Food and Drug Administration, and the Medical Standards of the Eye Bank Association of America in the United States. Opinions on promoting eyeball donation, improving the monitoring system for donated corneas and revising laws related to cornea management were gathered. The perspectives of 31 experts affiliated with the Korea Cornea Society were collected through a survey.
Results:
Currently, there are no laws or regulations that can be appropriately applied to the cornea which has properties of both organs and tissue. Additionally, there is no law regulating imported corneas. Therefore, there is a need to legislate or revise the current law; all experts who conducted the survey agreed on this. Furthermore, the current system faces limitations in the efficient procurement, stable supply, and management of donor corneas, as well as in donation promotion. To address these issues, the establishment of independent legislation for managing donated corneas and a National Central Eye Bank was proposed. This central body would oversee continuous personnel training, education, and monitoring, along with ensuring stable procurement, processing, and supply of corneas within a structured management system. Sixty-eight percent of the surveyed experts agreed with this proposal.
Conclusions
To establish a safe and efficient Korean corneal supply and demand system, it is imperative to enact cornea-specific laws, including the establishment of a National Central Eye Bank.
2.The Korean Contact Lens Study Society Member Survey: Diagnosis and Treatment Trends of Acanthamoeba Keratitis
Jaeyoung KIM ; Min Ho KANG ; Roo Min JUN
Annals of Optometry and Contact Lens 2026;25(1):12-18
Purpose:
This study reports the results of a survey on the diagnosis and treatment status of Acanthamoeba keratitis among members of the Korean Contact Lens Study Society.
Methods:
To understand the current trends of diagnosis and treatment of Acanthamoeba keratitis in Korea, a 16-question survey was conducted on 1,189 members of the Korean Contact Lens Study Society in November 2024.
Results:
In total, 132 members responded to the survey (response rate; 11.1%). Among them, 79 members (59.8%) reported having encountered Acanthamoeba keratitis at least one case annually, whereas nine (6.8%) reported having experienced > 6 cases annually. Ninety-six members (72.7%) reported that they used slit-lamp microscopic findings and clinical symptoms as basis for diagnosis. Regarding first-line topical medication, 0.02% polyhexamethylene biguanide (PHMB) was the most commonly used (63.3%), followed by 0.02% PHMB plus 0.02% chlorhexidine combined therapy (26.3%) and 0.02% chlorhexidine alone (24.6%). In cases of progressive keratitis despite medical treatment, the surgical treatment options included corneal transplantation (58.6%) and corneal epithelial debridement (46%). Corticosteroids were used in 70 patients (61.9%) to manage neovascularization or corneal opacity after keratitis improved (75.9%,); 0.1% fluorometholone (64.7%) was used most frequently. After keratitis improved, 104 patients (94.5%) continued to use eye drops for > 2 months.
Conclusions
The survey showed the diagnosis and treatment trends of Acanthamoeba keratitis in Korea.
3.Effect of scan body geometric configuration and library design on digital implant impression accuracy
Hong Seok MOON ; Ahreum CHOI ; Kyung Chul OH ; Minji SUN ; Jaeyoung KIM
The Journal of Advanced Prosthodontics 2026;18(1):55-66
PURPOSE:
. The purpose of this in vitro study was to evaluate how variations in scan body geometry, specifically body height and the length of the flat indexing surface (FIS), affect linear and angular accuracy when combined with truncated or full-geometry library files.
MATERIALS AND METHODS:
. Nine scan body geometries were fabricated by combining three body heights (4, 5, and 6 mm) with three FIS lengths (1, 2, and 3 mm). Digital impressions were superimposed onto truncated or full-geometry library files. Linear deviation (ΔD) and angular deviation (ΔA) were calculated by comparing aligned scan bodies with coordinate measuring machine references. Linear and angular deviations were compared between library types using the Mann–Whitney U test, and differences among body heights and FIS lengths were evaluated using the Kruskal–Wallis test with Dunn’s post-hoc test (α = .05).
RESULTS:
. Linear deviation remained within a comparable range, and most geometry–library comparisons did not show a significant difference from body height, FIS length, or library morphology (P > .05). Angular deviation demonstrated geometry-dependent behavior, increasing only in the 4-mm body paired with larger FIS lengths, particularly when fullgeometry libraries were used. No significant angular differences were observed in the 5-mm or 6-mm body groups.
CONCLUSION
. Digital implant registration remained stable across most configurations. Shortened scan bodies performed reliably when FIS dimensions were preserved. Angular accuracy was more sensitive to geometry-library interactions, with truncated libraries improving stability.
4.Full-mouth rehabilitation in a patient with severe erosion and wear using various digital tools: a case report
Da-Jung JUNG ; Minji SUN ; June-Sung SHIM ; Jaeyoung KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):92-102
The rapid advancement of digital dentistry has enabled the integration of digital technologies into full-mouth rehabilitation, improving communication between clinicians and dental technicians while greatly enhancing treatment efficiency.This case report details the treatment of a patient with severe tooth erosion and wear, where full-mouth rehabilitation with an increase in vertical dimension was planned. Four digital tools‒an intraoral scanner, facial scanner, T-scan, and Jaw Motion Analyzer‒were used to collect and integrate data, which were then utilized to create a virtual patient through CAD software for the design and fabrication of the prosthesis. The effective use of these digital technologies supported the achievement of a stable occlusion and resulted in both functional and esthetic outcomes. This case demonstrates the effectiveness of a digital workflow in enhancing the accuracy and efficiency of the treatment process, producing clinically satisfactory results.
5.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
6.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
7.Full-mouth rehabilitation in a patient with severe erosion and wear using various digital tools: a case report
Da-Jung JUNG ; Minji SUN ; June-Sung SHIM ; Jaeyoung KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):92-102
The rapid advancement of digital dentistry has enabled the integration of digital technologies into full-mouth rehabilitation, improving communication between clinicians and dental technicians while greatly enhancing treatment efficiency.This case report details the treatment of a patient with severe tooth erosion and wear, where full-mouth rehabilitation with an increase in vertical dimension was planned. Four digital tools‒an intraoral scanner, facial scanner, T-scan, and Jaw Motion Analyzer‒were used to collect and integrate data, which were then utilized to create a virtual patient through CAD software for the design and fabrication of the prosthesis. The effective use of these digital technologies supported the achievement of a stable occlusion and resulted in both functional and esthetic outcomes. This case demonstrates the effectiveness of a digital workflow in enhancing the accuracy and efficiency of the treatment process, producing clinically satisfactory results.
8.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
9.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
10.Full-mouth rehabilitation in a patient with severe erosion and wear using various digital tools: a case report
Da-Jung JUNG ; Minji SUN ; June-Sung SHIM ; Jaeyoung KIM
The Journal of Korean Academy of Prosthodontics 2025;63(1):92-102
The rapid advancement of digital dentistry has enabled the integration of digital technologies into full-mouth rehabilitation, improving communication between clinicians and dental technicians while greatly enhancing treatment efficiency.This case report details the treatment of a patient with severe tooth erosion and wear, where full-mouth rehabilitation with an increase in vertical dimension was planned. Four digital tools‒an intraoral scanner, facial scanner, T-scan, and Jaw Motion Analyzer‒were used to collect and integrate data, which were then utilized to create a virtual patient through CAD software for the design and fabrication of the prosthesis. The effective use of these digital technologies supported the achievement of a stable occlusion and resulted in both functional and esthetic outcomes. This case demonstrates the effectiveness of a digital workflow in enhancing the accuracy and efficiency of the treatment process, producing clinically satisfactory results.

Result Analysis
Print
Save
E-mail