1.Does the size of the cold snare affect the outcome of cold snare polypectomy in the colon? A KASID prospective multicenter study
Seongwoo CHOI ; Jaeyoung CHUN ; Geunhyuk CHOI ; Yoojin LEE ; Taegeun GWEON ; Yunho JUNG
Intestinal Research 2026;24(1):76-83
Background/Aims:
Cold snare polypectomy (CSP) is recommended for colorectal polyps <10 mm; however, the impact of snare size on clinical outcomes remains unclear. This study evaluated the efficacy and safety of 10-mm and 15-mm snares for CSP of small colorectal polyps.
Methods:
In this prospective multicenter study, patients with 4–10 mm non-pedunculated polyps underwent CSP with either a 10-mm or 15-mm snare. Both snares had identical wire thickness and hexagonal loop design. The primary outcome was histological complete resection rate (CRR). Secondary outcomes included adverse events and technical parameters.
Results:
In total, 182 patients were enrolled (10-mm group: n = 92; 15-mm group: n = 90). Baseline characteristics, including age, sex, polyp size, morphology, location, and pathology, were comparable between groups. Histological CRRs were 90.2% in the 10-mm group and 91.1% in the 15-mm group (P= 0.483). No significant differences were observed in the presence of submucosal tissue within specimens (P= 0.523), iatrogenic ulcer size (P= 0.532), hematoma occurrence (P= 0.391), or intraprocedural bleeding requiring hemostasis (6.5% vs. 5.6%; P= 0.974). No cases of delayed bleeding or perforation were reported. Logistic regression analysis identified iatrogenic ulcer size > 8 mm as an independent predictor of complete resection (odds ratio, 3.89; 95% confidence interval, 1.15–13.21; P= 0.029); snare size was not significantly associated with CRR (P= 0.519).
Conclusions
CSP using either a 10-mm or a 15-mm snare for 4–10 mm non-pedunculated colorectal polyps showed no significant difference in complete resection or safety outcomes within this size range. (Clinical Research Information Service [CRIS], KCT0005031)
2.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
3.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
4.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
5.Survey of the Actual Practices Used for Endoscopic Removal of Colon Polyps in Korea: A Comparison with the Current Guidelines
Jeongseok KIM ; Tae-Geun GWEON ; Min Seob KWAK ; Su Young KIM ; Seong Jung KIM ; Hyun Gun KIM ; Sung Noh HONG ; Eun Sun KIM ; Chang Mo MOON ; Dae Seong MYUNG ; Dong-Hoon BAEK ; Shin Ju OH ; Hyun Jung LEE ; Ji Young LEE ; Yunho JUNG ; Jaeyoung CHUN ; Dong-Hoon YANG ; Eun Ran KIM ; Intestinal Tumor Research Group of the Korean Association for the Study of Intestinal Diseases
Gut and Liver 2025;19(1):77-86
Background/Aims:
We investigated the clinical practice patterns of Korean endoscopists for the endoscopic resection of colorectal polyps.
Methods:
From September to November 2021, an online survey was conducted regarding the preferred resection methods for colorectal polyps, and responses were compared with the international guidelines.
Results:
Among 246 respondents, those with <4 years, 4–9 years, and ≥10 years of experiencein colonoscopy practices accounted for 25.6%, 34.1%, and 40.2% of endoscopists, respectively. The most preferred resection methods for non-pedunculated lesions were cold forceps polypectomy for ≤3 mm lesions (81.7%), cold snare polypectomy for 4–5 mm (61.0%) and 6–9 mm (43.5%) lesions, hot endoscopic mucosal resection (EMR) for 10–19 mm lesions (72.0%), precut EMR for 20–25 mm lesions (22.0%), and endoscopic submucosal dissection (ESD) for ≥26 mm lesions (29.3%). Hot EMR was favored for pedunculated lesions with a head size <20 mm and stalk size <10 mm (75.6%) and for those with a head size ≥20 mm or stalk size ≥10 mm (58.5%). For suspected superficial and deep submucosal lesions measuring 10–19 mm and ≥20 mm, ESD (26.0% and 38.6%) and surgery (36.6% and 46.3%) were preferred, respectively. The adherence rate to the guidelines ranged from 11.2% to 96.9%, depending on the size, shape, and histology of the lesions.
Conclusions
Adherence to the guidelines for endoscopic resection techniques varied depend-ing on the characteristics of colorectal polyps. Thus, an individualized approach is required to increase adherence to the guidelines.
6.Endoscopic mucosal resection using anchored snare Tip-in versus precut technique for small rectal neuroendocrine tumors
Seung Wook HONG ; Dong-Hoon YANG ; Yoo Jin LEE ; Dong Hoon BAEK ; Jaeyoung CHUN ; Hyun Gun KIM ; Sung Joo KIM ; Seung-Mo HONG ; Dae-Seong MYUNG
The Korean Journal of Internal Medicine 2024;39(2):238-247
Background/Aims:
Small rectal neuroendocrine tumors (NETs) can be treated with modified endoscopic mucosal resection (EMR). However, an optimal EMR method remains to be established. We aimed to assess the non-inferiority of Tip-in EMR versus precut EMR (EMR-P) for treating rectal NETs.
Methods:
This prospective, multicenter, randomized controlled trial enrolled patients with rectal NETs of < 10 mm in diameter. The patients were randomly assigned to EMR-P and Tip-in EMR groups in a 1:1 ratio. Primary outcome was margin-negative (R0) resection rate between the two methods, with a noninferiority margin of 10%.
Results:
Seventy-five NETs in 73 patients, including 64 eligible lesions (32 lesions in each, EMR-P and Tip-in EMR groups), were evaluated. In a modified intention-to-treat analysis, R0 resection rates of the EMR-P and Tip-in EMR groups were 96.9% and 90.6%, respectively, which did not demonstrate non-inferiority (risk difference, -6.3 [95% confidence interval: -18.0 to 5.5]). Resection time in the EMR-P group was longer than that in the Tip-in EMR group (p < 0.001). One case of intraprocedural bleeding was reported in each group.
Conclusions
We did not demonstrate the non-inferiority of Tip-in EMR compared to EMR-P for treating small rectal NETs. However, the R0 resection rates for both techniques were high enough for clinical application.
7.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
8.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
9.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.
10.Efficacy of Oral Sulfate Tablet and 2 L-Polyethylene Glycol With Ascorbic Acid for Bowel Preparation: A Prospective Randomized KASID Multicenter Trial
Yunho JUNG ; Hyun Gun KIM ; Dong-Hoon YANG ; Hyoun Woo KANG ; Jae Jun PARK ; Dong Hoon BAEK ; Jaeyoung CHUN ; Tae-Geun GWEON ; Hyeon Jeong GOONG ; Min Seob KWAK ; Hyun Jung LEE ; Soo-Kyung PARK ; Jong Hoon LEE
Journal of Korean Medical Science 2024;39(48):e301-
Background:
Oral sulfate tablets (OSTs) are bowel preparation agents that combine oral sulfate solution and simethicone. This study compared the efficacy, tolerability, and safety of OST compared to 2 L-polyethylene glycol plus ascorbic acid (2 L-PEG/ASC).
Methods:
This prospective, randomized, controlled, single-blinded, multicenter, noninferiority trial enrolled 211 healthy adults who underwent colonoscopy between May 2020 and September 2022 at 13 university hospitals. The bowel cleansing rate was assessed using the Boston Bowel Preparation Scale (BBPS) and Harefield Cleansing Scale (HCS), and the preparation agents were administered in split regimens.
Results:
The total BBPS score (8.2 ± 1.5 vs. 7.8 ± 1.4, p = 0.040) and the high-quality bowel cleansing rates in the right colon (73.2% vs. 50.5), transverse colon (80.6% vs. 68.0%), and left colon (81.5% vs. 67.0%) on the BBPS were significantly higher in the OST group than in the 2 L-PEG/ASC group. However, the rates of successful cleansing according to BBPS (90.7% vs. 91.2%) and HCS (96.3% vs. 94.2%) did not significantly differ between the two groups.The taste, ease, and amount of consumption of the preparation agent; and willingness to repeat colonoscopy with the same agent (89.8% vs. 78.6%, P = 0.026) were significantly better in the OST group compared to the 2 L-PEG/ASC group. Adverse events and clinically significant laboratory changes were not significantly different between the two groups.
Conclusion
The OST was not inferior to 2 L-PEG/ASC in terms of bowel cleansing efficacy and showed better tolerability when used for bowel preparation for colonoscopy.

Result Analysis
Print
Save
E-mail