1.Transcatheter ventilation with a modified Rapid-O2 oxygen insufflation device
Jaewon JANG ; Hye Jin KIM ; Hyun Joo KIM ; Wyun Kon PARK
Korean Journal of Anesthesiology 2025;78(1):61-72
Background:
The Rapid-O2 oxygen insufflation device® (Rapid-O2) was designed primarily for rescue oxygenation in cannot intubate, cannot oxygenate (CICO) events; thus, hypercapnia is inevitable. Rapid-O2 was modified to enhance ventilation using the Venturi effect during expiration.
Methods:
To determine the most effective combination of inner catheters (20 gauge [G], 18 G, 16 G, 14 G, and 2-mm inner diameter [ID] transtracheal catheter [TTC]) and insufflation catheters (16 G, 14 G, and 2-mm ID TTC) for achieving optimum ventilation, insufflating and expiratory flows were measured at an oxygen flow rate of 15 L/min. The insufflating and expiratory pressures were measured at 6–15 L/min. The flows and pressures were measured using a gas flow analyzer. The insufflating and expiratory times were measured using a trachea-lung model to obtain minute volumes. To assess the improvement by modifying the Rapid-O2, minute volumes were measured using the Rapid-O2.
Results:
The most appropriate inner catheter was 18 G. The insufflating pressures ranged from 97 (2-mm ID TTC) to 377 cmH2O (16 G) at 15 L/min. During expiration, similar negative pressures of 50 cmH2O were measured in the insufflation catheters at 15 L/min. At lung compliance of 100 ml/cmH2O, the minute volumes through a 2-mm ID and 14 G insufflation catheters were 7.0 and 5.37 L/min, respectively, at 15 L/min. The minute volumes were significantly greater in modified Rapid-O2.
Conclusions
Modified Rapid-O2 provided sufficient minute volumes in adults using a 14 G or 2-mm ID insufflation catheter at 15 L/min, demonstrating its potential for ventilation in CICO events.
2.Transcatheter ventilation with a modified Rapid-O2 oxygen insufflation device
Jaewon JANG ; Hye Jin KIM ; Hyun Joo KIM ; Wyun Kon PARK
Korean Journal of Anesthesiology 2025;78(1):61-72
Background:
The Rapid-O2 oxygen insufflation device® (Rapid-O2) was designed primarily for rescue oxygenation in cannot intubate, cannot oxygenate (CICO) events; thus, hypercapnia is inevitable. Rapid-O2 was modified to enhance ventilation using the Venturi effect during expiration.
Methods:
To determine the most effective combination of inner catheters (20 gauge [G], 18 G, 16 G, 14 G, and 2-mm inner diameter [ID] transtracheal catheter [TTC]) and insufflation catheters (16 G, 14 G, and 2-mm ID TTC) for achieving optimum ventilation, insufflating and expiratory flows were measured at an oxygen flow rate of 15 L/min. The insufflating and expiratory pressures were measured at 6–15 L/min. The flows and pressures were measured using a gas flow analyzer. The insufflating and expiratory times were measured using a trachea-lung model to obtain minute volumes. To assess the improvement by modifying the Rapid-O2, minute volumes were measured using the Rapid-O2.
Results:
The most appropriate inner catheter was 18 G. The insufflating pressures ranged from 97 (2-mm ID TTC) to 377 cmH2O (16 G) at 15 L/min. During expiration, similar negative pressures of 50 cmH2O were measured in the insufflation catheters at 15 L/min. At lung compliance of 100 ml/cmH2O, the minute volumes through a 2-mm ID and 14 G insufflation catheters were 7.0 and 5.37 L/min, respectively, at 15 L/min. The minute volumes were significantly greater in modified Rapid-O2.
Conclusions
Modified Rapid-O2 provided sufficient minute volumes in adults using a 14 G or 2-mm ID insufflation catheter at 15 L/min, demonstrating its potential for ventilation in CICO events.
3.Transcatheter ventilation with a modified Rapid-O2 oxygen insufflation device
Jaewon JANG ; Hye Jin KIM ; Hyun Joo KIM ; Wyun Kon PARK
Korean Journal of Anesthesiology 2025;78(1):61-72
Background:
The Rapid-O2 oxygen insufflation device® (Rapid-O2) was designed primarily for rescue oxygenation in cannot intubate, cannot oxygenate (CICO) events; thus, hypercapnia is inevitable. Rapid-O2 was modified to enhance ventilation using the Venturi effect during expiration.
Methods:
To determine the most effective combination of inner catheters (20 gauge [G], 18 G, 16 G, 14 G, and 2-mm inner diameter [ID] transtracheal catheter [TTC]) and insufflation catheters (16 G, 14 G, and 2-mm ID TTC) for achieving optimum ventilation, insufflating and expiratory flows were measured at an oxygen flow rate of 15 L/min. The insufflating and expiratory pressures were measured at 6–15 L/min. The flows and pressures were measured using a gas flow analyzer. The insufflating and expiratory times were measured using a trachea-lung model to obtain minute volumes. To assess the improvement by modifying the Rapid-O2, minute volumes were measured using the Rapid-O2.
Results:
The most appropriate inner catheter was 18 G. The insufflating pressures ranged from 97 (2-mm ID TTC) to 377 cmH2O (16 G) at 15 L/min. During expiration, similar negative pressures of 50 cmH2O were measured in the insufflation catheters at 15 L/min. At lung compliance of 100 ml/cmH2O, the minute volumes through a 2-mm ID and 14 G insufflation catheters were 7.0 and 5.37 L/min, respectively, at 15 L/min. The minute volumes were significantly greater in modified Rapid-O2.
Conclusions
Modified Rapid-O2 provided sufficient minute volumes in adults using a 14 G or 2-mm ID insufflation catheter at 15 L/min, demonstrating its potential for ventilation in CICO events.
4.Transcatheter ventilation with a modified Rapid-O2 oxygen insufflation device
Jaewon JANG ; Hye Jin KIM ; Hyun Joo KIM ; Wyun Kon PARK
Korean Journal of Anesthesiology 2025;78(1):61-72
Background:
The Rapid-O2 oxygen insufflation device® (Rapid-O2) was designed primarily for rescue oxygenation in cannot intubate, cannot oxygenate (CICO) events; thus, hypercapnia is inevitable. Rapid-O2 was modified to enhance ventilation using the Venturi effect during expiration.
Methods:
To determine the most effective combination of inner catheters (20 gauge [G], 18 G, 16 G, 14 G, and 2-mm inner diameter [ID] transtracheal catheter [TTC]) and insufflation catheters (16 G, 14 G, and 2-mm ID TTC) for achieving optimum ventilation, insufflating and expiratory flows were measured at an oxygen flow rate of 15 L/min. The insufflating and expiratory pressures were measured at 6–15 L/min. The flows and pressures were measured using a gas flow analyzer. The insufflating and expiratory times were measured using a trachea-lung model to obtain minute volumes. To assess the improvement by modifying the Rapid-O2, minute volumes were measured using the Rapid-O2.
Results:
The most appropriate inner catheter was 18 G. The insufflating pressures ranged from 97 (2-mm ID TTC) to 377 cmH2O (16 G) at 15 L/min. During expiration, similar negative pressures of 50 cmH2O were measured in the insufflation catheters at 15 L/min. At lung compliance of 100 ml/cmH2O, the minute volumes through a 2-mm ID and 14 G insufflation catheters were 7.0 and 5.37 L/min, respectively, at 15 L/min. The minute volumes were significantly greater in modified Rapid-O2.
Conclusions
Modified Rapid-O2 provided sufficient minute volumes in adults using a 14 G or 2-mm ID insufflation catheter at 15 L/min, demonstrating its potential for ventilation in CICO events.
5.The Life Functioning Scale: A Measurement Tool Developed to Assess the Physical Functioning Abilities of Community-Dwelling Adults Aged 50 Years or Older
Yunhwan LEE ; Eunsaem KIM ; Jihye YUN ; Jaewon CHOI ; Jinhee KIM ; Chang Won WON ; Miji KIM ; Soongnang JANG ; Kyungwon OH ; Jihee KIM
Annals of Geriatric Medicine and Research 2024;28(4):410-418
Background:
This study aimed to develop an instrument for assessing physical functioning among adults aged 50 years or older living in the community.
Methods:
Based on a review of various national health surveys and cohort studies, a 144-item bank was constructed for assessing physical functioning. Focus group interviews were conducted among adults aged 50 years or older to investigate their level of understanding of 60 selected items, followed by a pretest of the items on a nationally representative sample (n=508). The final 25-item questionnaire was tested on an independent sample (n=259) for validity and reliability based on classical test and item response theories. Predictive validity at the 6-month follow-up was tested in a separate sample (n=263).
Results:
The newly developed Life Functioning (LF) scale assessed the dimensions of functional limitations, disabilities, and social activities. The scale satisfied a one-dimensionality assumption with good item fit and demonstrated criterion validity, construct validity, high internal consistency (Cronbach’s alpha=0.93), and test-retest reliability (intra-class correlation coefficient=0.84; 95% confidence interval, 0.76–0.89). The LF scale comprised 25 items with a total score ranging from 0 to 100. Higher scores indicated higher levels of functioning. The LF score was significantly associated with the Physical Functioning score at 6 months.
Conclusion
The LF scale was developed to assess the physical functioning of people in their late midlife or older. Future studies should test the instrument on a national sample and evaluate its application in diverse population subgroups.
6.Genetics of Cerebral Palsy: Diagnosis, Differential Diagnosis, and Beyond
Dae-Hyun JANG ; Jaewon KIM ; Aloysia Leisanne SCHWABE ; Timothy Edward LOTZE
Annals of Rehabilitation Medicine 2024;48(6):369-376
Cerebral palsy (CP) is the most common motor disability in children, characterized by diverse clinical manifestations and often uncertain etiology, which has spurred increasing interest in genetic diagnostics. This review synthesizes findings from various studies to enhance understanding of CP’s genetic underpinnings. The discussion is structured around five key areas: monogenic causes and copy number variants directly linked to CP, differential genetic disorders including atypical CP and mimics, ambiguous genetic influences, co-occurrence with other neurodevelopmental disorders, and polygenic risk factors. Case studies illustrate the clinical application of these genetic insights, underscoring the complexity of diagnosing CP due to the phenotypic overlap with other conditions and the potential for misdiagnosis. The review highlights the significant role of advanced genetic testing in distinguishing CP from similar neurodevelopmental disorders and assessing cases with unclear clinical presentations. Furthermore, it addresses the ongoing challenges in establishing a consensus on genetic contributors to CP, the need for comprehensive patient phenotyping, and the integration of rigorous genetic and functional studies to validate findings. This comprehensive examination of CP genetics aims to pave the way for more precise diagnostics and personalized treatment plans, urging continued research to overcome the current limitations and refine diagnostic criteria within this field.
7.Impact of Preanesthetic Blood Pressure Deviations on 30-Day Postoperative Mortality in Non-Cardiac Surgery Patients
Sang-Wook LEE ; Seongyong PARK ; Jin-Young KIM ; Baehun MOON ; Donghee LEE ; Jaewon JANG ; Woo-young SEO ; Hyun-Seok KIM ; Sung-Hoon KIM ; Jiyeon SIM
Journal of Korean Medical Science 2024;39(35):e241-
Background:
Blood pressure readings taken before anesthesia often influence the decision to delay or cancel elective surgeries. However, the implications of these specific blood pressure values, especially how they compare to baseline, on postoperative in-hospital 30-day mortality remain underexplored. This research aimed to examine the effect of discrepancies between the baseline blood pressure evaluated in the ward a day before surgery, and the blood pressure observed just before the administration of anesthesia, on the postoperative mortality risks.
Methods:
The study encompassed 60,534 adults scheduled for non-cardiac surgeries at a tertiary care center in Seoul, Korea. Baseline blood pressure was calculated as the mean of the blood pressure readings taken within 24 hours prior to surgery. The preanesthetic blood pressure was the blood pressure measured right before the administration of anesthesia. We focused on in-hospital 30-day mortality as the primary outcome.
Results:
Our research revealed that a lower preanesthetic systolic or mean blood pressure that deviates by 20 mmHg or more from baseline significantly increased the risk of 30-day mortality. This association was particularly pronounced in individuals with a history of hypertension and those aged 65 and above. Higher preanesthetic blood pressure was not significantly associated with an increased risk of 30-day mortality.
Conclusion
We found that a lower preanesthetic blood pressure compared to baseline significantly increased the 30-day postoperative mortality risk, whereas a higher preanesthetic blood pressure did not. Our study emphasizes the critical importance of accounting for variations in both baseline and preanesthetic blood pressure when assessing surgical risks and outcomes.
8.Advantages of laparoscopy in gynecologic surgery in elderly patients
Jaewon NA ; Young Eun CHUNG ; Il-Yeo JANG ; Yoo-Young LEE ; Tae-Joong KIM ; Jeong-Won LEE ; Byoung-Gie KIM ; Chi-Son CHANG ; Chel Hun CHOI
Obstetrics & Gynecology Science 2024;67(2):243-252
Objective:
Geriatric patients requiring gynecological surgery is increasing worldwide. However, older patients are at higher risk of postoperative morbidity and mortality, particularly cardiopulmonary complications. Laparoscopic surgery is widely used as a minimally invasive method for reducing postoperative morbidities. We compared the outcomes of open and laparoscopic gynecologic surgeries in patients older than 55 years.
Methods:
We included patients aged >55 years who underwent gynecological surgery at a single tertiary center between 2010 and 2020, excluding vaginal or ovarian cancer surgeries were excluded. Surgical outcomes were compared between the open surgery and laparoscopic groups, with age cutoff was set at 65 years for optimal discriminative power. We performed linear or logistic regression analyses to compare the surgical outcomes according to age and operation type.
Results:
Among 2,983 patients, 28.6% underwent open surgery and 71.4% underwent laparoscopic surgery. Perioperative outcomes of laparoscopic surgery were better than those of open surgery in all groups. In both the open and laparoscopic surgery groups, the older patients showed worse overall surgical outcomes. However, age-related differences in perioperative outcomes were less severe in the laparoscopic group. In the linear regression analysis, the differences in estimated blood loss, transfusion, and hospital stay between the age groups were smaller in the laparoscopy group. Similar results were observed in cancer-only and benign-only cohorts.
Conclusion
Although the surgical outcomes were worse in the older patients, the difference between age groups was smaller for laparoscopic surgery. Laparoscopic surgery offers more advantages and safety in patients aged >65 years.
9.The Life Functioning Scale: A Measurement Tool Developed to Assess the Physical Functioning Abilities of Community-Dwelling Adults Aged 50 Years or Older
Yunhwan LEE ; Eunsaem KIM ; Jihye YUN ; Jaewon CHOI ; Jinhee KIM ; Chang Won WON ; Miji KIM ; Soongnang JANG ; Kyungwon OH ; Jihee KIM
Annals of Geriatric Medicine and Research 2024;28(4):410-418
Background:
This study aimed to develop an instrument for assessing physical functioning among adults aged 50 years or older living in the community.
Methods:
Based on a review of various national health surveys and cohort studies, a 144-item bank was constructed for assessing physical functioning. Focus group interviews were conducted among adults aged 50 years or older to investigate their level of understanding of 60 selected items, followed by a pretest of the items on a nationally representative sample (n=508). The final 25-item questionnaire was tested on an independent sample (n=259) for validity and reliability based on classical test and item response theories. Predictive validity at the 6-month follow-up was tested in a separate sample (n=263).
Results:
The newly developed Life Functioning (LF) scale assessed the dimensions of functional limitations, disabilities, and social activities. The scale satisfied a one-dimensionality assumption with good item fit and demonstrated criterion validity, construct validity, high internal consistency (Cronbach’s alpha=0.93), and test-retest reliability (intra-class correlation coefficient=0.84; 95% confidence interval, 0.76–0.89). The LF scale comprised 25 items with a total score ranging from 0 to 100. Higher scores indicated higher levels of functioning. The LF score was significantly associated with the Physical Functioning score at 6 months.
Conclusion
The LF scale was developed to assess the physical functioning of people in their late midlife or older. Future studies should test the instrument on a national sample and evaluate its application in diverse population subgroups.
10.Genetics of Cerebral Palsy: Diagnosis, Differential Diagnosis, and Beyond
Dae-Hyun JANG ; Jaewon KIM ; Aloysia Leisanne SCHWABE ; Timothy Edward LOTZE
Annals of Rehabilitation Medicine 2024;48(6):369-376
Cerebral palsy (CP) is the most common motor disability in children, characterized by diverse clinical manifestations and often uncertain etiology, which has spurred increasing interest in genetic diagnostics. This review synthesizes findings from various studies to enhance understanding of CP’s genetic underpinnings. The discussion is structured around five key areas: monogenic causes and copy number variants directly linked to CP, differential genetic disorders including atypical CP and mimics, ambiguous genetic influences, co-occurrence with other neurodevelopmental disorders, and polygenic risk factors. Case studies illustrate the clinical application of these genetic insights, underscoring the complexity of diagnosing CP due to the phenotypic overlap with other conditions and the potential for misdiagnosis. The review highlights the significant role of advanced genetic testing in distinguishing CP from similar neurodevelopmental disorders and assessing cases with unclear clinical presentations. Furthermore, it addresses the ongoing challenges in establishing a consensus on genetic contributors to CP, the need for comprehensive patient phenotyping, and the integration of rigorous genetic and functional studies to validate findings. This comprehensive examination of CP genetics aims to pave the way for more precise diagnostics and personalized treatment plans, urging continued research to overcome the current limitations and refine diagnostic criteria within this field.

Result Analysis
Print
Save