1.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
2.Perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain: a multicenter cross-sectional study in Korea
Jieun BAE ; Yun Hee LIM ; Sung Jun HONG ; Jae Hun JEONG ; Hey Ran CHOI ; Sun Kyung PARK ; Jung Eun KIM ; Jae Hun KIM
The Korean Journal of Pain 2025;38(1):69-78
Background:
Chronic pain significantly affects daily activities, mental health, and the interpersonal relationships of patients. Consequently, physicians use various treatments to manage pain. This study investigated the perceptions of treatment, accompanying symptoms, and other problems in patients with chronic pain.
Methods:
The authors enrolled patients with chronic pain from 19 university hospitals in South Korea. Data was collected on age, gender, diagnosis, disease duration, severity of pain, perception of pain treatment, and accompanying symptoms or problems using an anonymous survey comprising 19 questions.
Results:
In total, 833 patients with chronic pain completed the survey, and 257 (31.0%) and 537 (64.5%) patientsexpressed concerns about the potential adverse effects of medication and opioid addiction, respectively. Personalitychanges such as irritability or anger were the most frequent accompanying symptoms in 507 (63.8%) patients, followed by depression and sleep disturbance in 462 (58.1%) and 450 (54.5%) patients, respectively. Depression (P = 0.001) and anxiety (P = 0.029) were more common among women, whereas divorce (P = 0.016), family conflict (P < 0.001), unemployment (P < 0.001), suicide attempts (P < 0.001), and restrictions on economic activity (P < 0.001) were more common among men. The frequency of accompanying symptoms, except for suicidal ideation,was higher in the younger patients aged ≤ 40 years than in the older patients aged > 40 years.
Conclusions
Many patients with chronic pain had concerns about adverse effects or medication tolerance and experienced anxiety, depression, or sleep disturbances. The prevalence of accompanying problems varies according to age and gender.
3.Non-Inferiority Analysis of Electrocardiography Analysis Application vs. Point-of-Care Ultrasound for Screening Left Ventricular Dysfunction
Jin Hee KIM ; Jae Yun JUNG ; Joonghee KIM ; Youngjin CHO ; Eunkyoung LEE ; Dahyeon SON
Yonsei Medical Journal 2025;66(3):172-178
Purpose:
Point-of-care ultrasound (POCUS) is widely used for heart function evaluation in emergency departments (EDs), but requires specific equipment and skilled operators. This study evaluates the diagnostic accuracy of a mobile application for estimating left ventricular (LV) systolic dysfunction [left ventricular ejection fraction (LVEF) <40%] using electrocardiography (ECG) and tests its non-inferiority to POCUS.
Materials and Methods:
Patients (aged ≥20 years) were included if they had both a POCUS-based EF evaluation and an ECG within 24 hours of their ED visit between January and May 2022, along with formal echocardiography within 2 weeks before or after the visit. A mobile app (ECG Buddy, EB) estimated LVEF (EF from EB) and the risk of LV dysfunction (LV-Dysfunction score) from ECG waveforms, which were compared to NT-proBNP levels and POCUS-evaluated LVEF (EF from POCUS). A non-inferiority margin was set at an area under the curve (AUC) difference of 0.05.
Results:
Of the 181 patients included, 37 (20.4%) exhibited LV dysfunction. The AUCs for screening LV dysfunction using POCUS and NT-proBNP were 0.885 and 0.822, respectively. EF from EB and LV-Dysfunction score outperformed NT-proBNP, with AUCs of 0.893 and 0.884, respectively (p=0.017 and p=0.030, respectively). EF from EB was non-inferior to EF from POCUS, while LV-Dysfunction score narrowly missed the mark. A subgroup analysis of sinus-origin rhythm ECGs supported the non-inferiority of both EF from EB and LV-Dysfunction score to EF from POCUS.
Conclusion
A smartphone application that analyzes ECG image can screen for LV dysfunction with a level of accuracy comparable to that of POCUS.
4.Erratum: Correction of Text in the Article “The Long-term Outcomes and Risk Factors of Complications After Fontan Surgery: From the Korean Fontan Registry (KFR)”
Sang-Yun LEE ; Soo-Jin KIM ; Chang-Ha LEE ; Chun Soo PARK ; Eun Seok CHOI ; Hoon KO ; Hyo Soon AN ; I Seok KANG ; Ja Kyoung YOON ; Jae Suk BAEK ; Jae Young LEE ; Jinyoung SONG ; Joowon LEE ; June HUH ; Kyung-Jin AHN ; Se Yong JUNG ; Seul Gi CHA ; Yeo Hyang KIM ; Youngseok LEE ; Sanghoon CHO
Korean Circulation Journal 2025;55(3):256-257
6.Effect of Wearing Phospholipid-releasing Contact Lenses on Dry Eyes in Rabbits
Hyeon Jung KIM ; Sehie PARK ; Yun Kyoung RYU ; Jin Sun HWANG ; Sun Hee OH ; Jae Hwi LEE ; Gui Bae KIM ; Young Joo SHIN
Journal of the Korean Ophthalmological Society 2025;66(4):181-190
Purpose:
To investigate whether a new phospholipid-releasing soft contact lens can improve symptoms of dry eyes.
Methods:
The study used 2.5-3.0 kg New Zealand rabbits including both normal non-dry eye rabbits and dry eye rabbits, the latter having undergone electrocauterization of the meibomian glands to block the gland orifices. Each rabbit wore a control contact lens on one eye and a phospholipid-releasing contact lens on the other eye daily. Phospholipid-releasing and control contact lenses were provided by NEOVISION Co., Ltd. The parameters assessed included tear film break-up time, tear osmolarity, ocular surface staining, and central corneal thickness. After the experiment, the rabbits were euthanized and their conjunctival tissue was stained with Periodic Acid Schiff (PAS) to observe conjunctival goblet cells.
Results:
In both dry eye and normal non-dry eye rabbits, tear film break-up time was longer and tear osmolarity was lower when using the phospholipid-releasing contact lens compared to the control contact lens. The ocular surface remained unstained in normal non-dry eye rabbits while staining was observed in dry eye rabbits. There was no significant difference in central corneal thickness between the control and phospholipid-releasing contact lenses in either group. PAS staining showed no difference in conjunctival goblet cell density between the two lens types in normal non-dry eye rabbits. However, in dry eye rabbits, the conjunctival goblet cell density tended to be slightly higher with the phospholipid-releasing contact lens compared to the control lens.
Conclusions
Phospholipid-releasing contact lenses may help reduce dry eye symptoms and minimize contact lens-related complications by stabilizing the tear film and lowering tear osmolarity.
7.Effect of regional COVID-19 outbreak to emergency department response on acute myocardial infarction: a multicenter retrospective study
Young Wook KIM ; Sungbae MOON ; Hyun Wook RYOO ; Jae Yun AHN ; Jung Bae PARK ; Dong Eun LEE ; Sang Hun LEE ; Sangchan JIN ; You Ho MUN ; Jung Ho KIM ; Tae Chang JANG
Journal of the Korean Society of Emergency Medicine 2025;36(2):72-82
Objective:
The Daegu region experienced the first wave of the pandemic at the beginning of the coronavirus disease 2019 (COVID-19) outbreak in Korea. Other non-COVID-19-related treatments during a community outbreak, such as cardiovascular diseases, were expected to impact emergency departments. In acute myocardial infarctions, time is an important factor affecting the patient outcome. This study examined how community COVID-19 outbreak affected STsegment elevated myocardial infarction (STEMI) care in emergency departments.
Methods:
A retrospective analysis was performed on patients visiting five emergency departments in the Daegu area who were diagnosed with STEMI from February 18 to April 17 each year from 2018 to 2020. The demographic characteristics, prehospital variables, in-hospital time variables, and treatment results were collected. The cases were divided into the pre-COVID period and the COVID period for comparison.
Results:
The study included 254 patients (194 pre-COVID, 60 during COVID). The symptom-to-door time did not differ. Although the door-to-first doctor time was shortened (4 min vs. 2 min, P=0.01), the rate of coronary angiogram along with the door-to-angiogram time and the door-to-balloon time did not change. The length of stay in the emergency department was delayed during COVID-19 (median, 136 min vs. 404 min; P<0.01). The in-hospital length of stay and mortality were similar in both groups.
Conclusion
The time to treat STEMI was not delayed significantly during the first wave of the COVID-19 outbreak in the Daegu area compared with the pre-pandemic period. Mortality did not change. The length of stay was elongated significantly in the emergency department but not in the hospital.
8.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.
9.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.
10.Consensus Statements on Tinnitus Assessment and Treatment Outcome Evaluation: A Delphi Study by the Korean Tinnitus Study Group
Oak-Sung CHOO ; Jung Mee PARK ; Euyhyun PARK ; Jiwon CHANG ; Min Young LEE ; Ho Yun LEE ; In Seok MOON ; Jae-Jun SONG ; Kyu-Yup LEE ; Jae-Jin SONG ; Eui-Cheol NAM ; Shi Nae PARK ; Hyun Joon SHIM ; Yoon Chan RAH ; Jae-Hyun SEO
Journal of Korean Medical Science 2025;40(7):e93-
Background:
Tinnitus is a multifactorial condition with no universally accepted assessment guidelines. The Korean Tinnitus Study Group previously established consensus statements on the definition, classification, and diagnostic tests for tinnitus. As a continuation of this effort, this study aims to establish expert consensus on tinnitus assessment and treatment outcome evaluation, specifically tailored to the Korean clinical context.
Methods:
A modified Delphi method involving 26 otology experts from across Korea was used. A two-round Delphi survey was conducted to evaluate statements related to tinnitus assessment before and after treatment. Statements were rated on a scale of 1 to 9 for the level of agreement. Consensus was defined as ≥ 70% agreement (score of 7–9) and ≤ 15% disagreement (score of 1–3). Statistical measures such as content validity ratio and Kendall’s coefficient of concordance (W) were calculated to assess agreement levels.
Results:
Of the 46 assessment-related statements, 17 (37%) reached consensus, though overall pre-treatment assessments showed weak agreement (Kendall’s W = 0.319). Key areas of agreement included the use of the visual analogue scale, numeric rating scale, and validated questionnaires for pre-treatment evaluation. Five statements, such as the use of computed tomography, magnetic resonance imaging, and angiography for diagnosing pulsatile tinnitus, achieved over 90% agreement. For treatment outcome measurements, 8 of 12 statements (67%) reached a consensus, with moderate agreement (Kendall’s W = 0.513). Validated questionnaires and psychoacoustic tests were recommended for evaluating treatment effects within 12 weeks. While standardized imaging for pulsatile tinnitus and additional clinical tests were strongly recommended, full consensus was not achieved across all imaging modalities.
Conclusion
This study provides actionable recommendations for tinnitus assessment and treatment evaluation, emphasizing the use of standardized tools and individualized approaches based on patient needs. These findings offer a practical framework to enhance consistency and effectiveness in tinnitus management within Korean clinical settings.

Result Analysis
Print
Save
E-mail