1.Clinical Practice Guideline for the Prehospital Stage of Acute Stroke : III. Initial Decision for Primary Treatment in Subarachnoid Hemorrhage
Jae Sang OH ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Yuna JO ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Dae-Won KIM ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):35-50
Subarachnoid hemorrhage (SAH) is a stroke subtype with high mortality and poor functional outcomes. Prompt occlusion of a ruptured aneurysm at an early stage is crucial to prevent rebleeding, which can result in even higher mortality and more severe disabilities. The most critical initial decision in SAH management is the choice of treatment method with surgical clipping or endovascular coiling. We aimed to develop an evidence-based clinical guideline to select the optimal initial treatment in patients with SAH. We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer two population, intervention, comparison, outcome questions comparing clipping and coiling. The risk of bias was assessed using ROB 2.0 and the Newcastle-Ottawa Scale. The Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcome and mortality. We included six randomized control trials (RCTs) and 58 observational studies. Meta-analysis of RCTs showed that coiling improved functional outcomes compared to clipping (odds ratio [OR], 0.91; 95% confidence interval [CI], 0.86–0.97). No significant mortality difference was observed in RCTs (OR, 1.38; 95% CI, 0.91–2.09), but non-RCTs favored clipping for reduced mortality (OR, 0.77; 95% CI, 0.69–0.86). However, it is difficult to generalize these findings to all clinical situations, as patients with SAH have a highly variable clinical course. Final treatment decision should be tailored to the individual patient’s status, including aneurysm location, morphology, and the expertise available at the treatment center. Such decisions are best made by specialists such as a board-certified physician and should be explained to the patient and their caregivers, along with the rationale for selecting the most appropriate treatment at the given hospital. Korea has many certified endovascular neurosurgeons, cerebrovascular surgeons, and certified cerebrovascular centers. Proper selection of the most suitable treatment method by certified physicians and centers would greatly benefit patient outcomes and healthcare professionals.
2.Twig-Like Middle Cerebral Artery : Acquired Lesion Rather than Congenital Anomaly
Yung Ki PARK ; Byul-Hee YOON ; Eui-Hyun HWANG ; Jae Hoon KIM ; Hee In KANG ; Yu Deok WON ; Jin Whan CHEONG
Journal of Korean Neurosurgical Society 2026;69(1):51-60
Objective:
: A twig-like middle cerebral artery (T-MCA) is a rare condition characterized by steno-occlusion of the M1 segment of the middle cerebral artery (MCA) with nearby collateral arterial networks. Despite unclear pathophysiology, it is often classified as a congenital anomaly caused by failure of fusion of the plexiform MCA arterial plexus. We aimed to improve understanding of the pathophysiology of T-MCAs by analyzing incidental T-MCA findings and their natural history.
Methods:
: A retrospective chart review was performed between January 2011 and December 2023 at three medical centers treating both ischemic and hemorrhagic strokes. Patients with suspected MCA lesions were selected through radiology reports from computed tomography, magnetic resonance angiography, and digital subtraction imaging.
Results:
: We identified 51 T-MCA cases from a radiology report search spanning 13 years across three medical centers. The study included 9875 patients with ischemic stroke and 2097 with hemorrhagic stroke. Of the 51 T-MCA cases, incidental findings accounted for 25 (49.0%), ischemic stroke for 18 (35.3%), and hemorrhagic strokes accounted for eight cases (15.7%). T-MCA related ischemic and hemorrhagic strokes accounted for 0.18–0.38% of all strokes. The RNF213.R4810K mutation was identified in seven of 15 patients (46.7%) tested. We found three cases of a de-novo T-MCA that progressed from a normal MCA architecture.
Conclusion
: T-MCAs may represent an acquired secondary anomaly rather than a congenital lesion, followed by steno-occlusion of the focal MCA with new arterial network formation. Both Moyamoya angiopathy and chronic atherosclerosis likely contributed to disease progression. Formation of a microaneurysm, dilatation of the lenticulostriate artery, and hemodynamic stress can lead to stroke.
3.Clinical Practice Guidelines for the Prehospital Stage of Acute Stroke in Korea II : Transport Decisions for Patients with Acute Ischemic Stroke
Jae Sang OH ; Yuna JO ; Jong Min LEE ; Hong Suk AHN ; Jung-Jae KIM ; Kyoung Min JANG ; Gi-Yong YUN ; Jang Hun KIM ; Dongwook SEO ; Hyeong Jin LEE ; Jinwoo JEONG ; Kyoung-Chul CHA ; Yong Soo CHO ; Su Jin KIM ; Jongkyu PARK ; Won-Sang CHO ; Hoon KIM ; Young Woo KIM ; Seung Hun SHEEN ; Sang Weon LEE ; Jae Whan LEE ; Tae Gon KIM ; Sung-kon HA ; Sukh Que PARK ; Soon Chan KWON
Journal of Korean Neurosurgical Society 2026;69(1):23-34
The mothership (MS) model, where patients are directly transferred to a thrombectomy-capable center, and the drip-and-ship (DS) model, where thrombolysis is initiated at the nearest primary stroke center before transfer for thrombectomy, are the primary transport modes for patients with stroke. We aimed to establish guidelines for selecting the appropriate transfer strategy based on emergent large vessel occlusion (LVO). We developed this guideline based on evidence from systematic reviews and meta-analyses via a de novo process. A systematic literature review was conducted across four databases (MEDLINE, Embase, Cochrane, and KoreaMed) to answer three Population, Intervention, Comparison, and Outcome questions comparing MS and DS models. The risk of bias was assessed using the Newcastle-Ottawa Scale. Preferred Reporting Items for Systematic Reviews and Meta-Analyses flow diagrams and meta-analyses were generated for functional outcomes, mortality, and successful recanalization. Twenty-six non-randomized controlled studies showed that the MS model improved good functional outcomes by approximately 14% compared with the DS model (odds ratio [OR], 1.14; 95% confidence interval [CI], 1.00–1.30). Fifteen studies reported that mortality in the MS and DS models showed no significant differences (OR, 0.97; 95% CI, 0.84–1.11). Twenty-four studies revealed no significant difference in successful recanalization between the MS and DS models (OR, 0.87; 95% CI, 0.68–1.10). The MS model should be considered first to improve the functional outcome of patients with LVO. However, if thrombectomy cannot be performed immediately after thrombolysis, or if a thrombectomy-enabled hospital is not nearby, the DS model should be considered by stroke specialists depending on transportation time and regional factors. We suggest a mixed approach with the DS model based on specific circumstances or regions to ensure the optimum treatment of patients with acute ischemic stroke (AIS). Appropriate transport for patients with LVO improves the prognosis of AIS.
4.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.National trends in surgical treatment and clinical outcomes among patients with aneurysmal subarachnoid hemorrhage in the Republic of Korea
Yung Ki PARK ; Byul-Hee YOON ; Eui-Hyun HWANG ; Jae Hoon KIM ; Hee In KANG ; Yu Deok WON ; Jin Whan CHEONG
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):19-32
Objective:
In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.
Methods:
Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used. Yearly trends in mortality rates and poor prognosis, using tracheostomy as proxy, were analyzed by a simple regression analysis. A multistep logistic regression analysis was performed to evaluate the risk factors of mortality and poor prognosis.
Results:
Overall, 83,587 patients were included. Females were predominant (64.5%). Microsurgical clip usage rate decreased by approximately two-thirds from 78.8% in 2005 to 24.4% in 2020. Contrarily, endovascular treatment proportion gradually increased, and stent-assisted coil embolization rate surpassed microsurgical clip usage rate in 2020 (24.6% vs. 24.4%). In the multivariate analysis, endovascular treatment correlated positively with 3-month mortality (hazard ratio [HR]: 1.13, 95% confidence interval [CI]: 1.07–1.19, P<0.0001), although correlated negatively with poor prognosis (tracheostomy) (HR: 0.93, 95% CI: 0.89–0.98, P=0.0050).
Conclusions
According to the treatment trend analysis, during the 16 years studied, for patients with subarachnoid hemorrhage due to ruptured cerebral aneurysm, the endovascular treatment rate increased rapidly and stent-assisted coil embolization rate surpassed that of microsurgical clip ligation. Diversification of treatment methods has led to a decrease in mortality and improved prognosis.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.National trends in surgical treatment and clinical outcomes among patients with aneurysmal subarachnoid hemorrhage in the Republic of Korea
Yung Ki PARK ; Byul-Hee YOON ; Eui-Hyun HWANG ; Jae Hoon KIM ; Hee In KANG ; Yu Deok WON ; Jin Whan CHEONG
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):19-32
Objective:
In this study, changes in treatment methods and patient prognosis were analyzed using a Korean nationwide medical insurance information database.
Methods:
Patients with subarachnoid hemorrhage who received surgical treatment for cerebral aneurysm from 2005 to 2020 were included. The specific surgery type was classified using the surgical code and according to whether stents were used. Yearly trends in mortality rates and poor prognosis, using tracheostomy as proxy, were analyzed by a simple regression analysis. A multistep logistic regression analysis was performed to evaluate the risk factors of mortality and poor prognosis.
Results:
Overall, 83,587 patients were included. Females were predominant (64.5%). Microsurgical clip usage rate decreased by approximately two-thirds from 78.8% in 2005 to 24.4% in 2020. Contrarily, endovascular treatment proportion gradually increased, and stent-assisted coil embolization rate surpassed microsurgical clip usage rate in 2020 (24.6% vs. 24.4%). In the multivariate analysis, endovascular treatment correlated positively with 3-month mortality (hazard ratio [HR]: 1.13, 95% confidence interval [CI]: 1.07–1.19, P<0.0001), although correlated negatively with poor prognosis (tracheostomy) (HR: 0.93, 95% CI: 0.89–0.98, P=0.0050).
Conclusions
According to the treatment trend analysis, during the 16 years studied, for patients with subarachnoid hemorrhage due to ruptured cerebral aneurysm, the endovascular treatment rate increased rapidly and stent-assisted coil embolization rate surpassed that of microsurgical clip ligation. Diversification of treatment methods has led to a decrease in mortality and improved prognosis.
9.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
10.Study on the Necessity and Methodology for Enhancing Outpatient and Clinical Education in the Department of Radiology
Soo Buem CHO ; Jiwoon SEO ; Young Hwan KIM ; You Me KIM ; Dong Gyu NA ; Jieun ROH ; Kyung-Hyun DO ; Jung Hwan BAEK ; Hye Shin AHN ; Min Woo LEE ; Seunghyun LEE ; Seung Eun JUNG ; Woo Kyoung JEONG ; Hye Doo JEONG ; Bum Sang CHO ; Hwan Jun JAE ; Seon Hyeong CHOI ; Saebeom HUR ; Su Jin HONG ; Sung Il HWANG ; Auh Whan PARK ; Ji-hoon KIM
Journal of the Korean Society of Radiology 2025;86(1):199-200

Result Analysis
Print
Save
E-mail