1.Risk factors and prognosis of first extubation failure in neonates undergoing invasive mechanical ventilation.
Mengyao WU ; Hui RONG ; Rui CHENG ; Yang YANG ; Keyu LU ; Fei SHEN
Journal of Central South University(Medical Sciences) 2025;50(8):1398-1407
OBJECTIVES:
Prolonged invasive mechanical ventilation is associated with increased risks of severe complications such as retinopathy of prematurity and bronchopulmonary dysplasia. Although neonatal intensive care unit (NICU) follow the principle of early extubation, extubation failure rates remain high, and reintubation may further increase the risk of adverse outcomes. This study aims to identify risk factors and short-term prognosis associated with first extubation failure in neonates, to provide evidence for effective clinical intervention strategies.
METHODS:
Clinical data of neonates who received invasive ventilation in the NICU of Children's Hospital of Nanjing Medical University from January 1, 2019, to December 31, 2021, were retrospectively collected. Neonates were divided into a successful extubation group and a failed extubation group based on whether reintubation occurred within 72 hours after the first extubation. Risk factors and short-term outcomes related to extubation failure were analyzed.
RESULTS:
A total of 337 infants were included, with 218 males (64.69%). Initial extubation failed in 34 (10.09%) infants. Compared with the successful extubation group, the failed extubation group had significantly lower gestational age [(31.37±5.14) weeks vs (34.44±4.07) weeks], age [2.5 (1.00, 8.25) h vs 5 (1.00, 22.00) h], birth weight [(1 818.97±1128.80) g vs (2 432.18±928.94) g], 1-minute Apgar score (6.91±1.90 vs 7.68±2.03), and the proportion of using mask oxygenation after extubation (21% vs 46%) (all P<0.05). Conversely, compared with the successful extubation group, the failed extubation group had significantly higher rates of vaginal delivery (59% vs 32%), caffeine use during mechanical ventilation (71% vs 38%), dexamethasone use at extubation (44% vs 17%), the highest positive end-expiratory pressure level within 72 hours post-extubation [6(5.00, 6.00) cmH2O vs 5 (0.00, 6.00) cmH2O] (1 cmH2O=0.098 kPa), the highest FiO2 within 72 hours post-extubation [(34.35±5.95)% vs (30.22±3.58)%], and duration of noninvasive intermittent positive pressure ventilation after extubation [0.5 (0.00, 42.00) hours vs 0 (0, 0) hours] (all P<0.05). Multivariate analysis identified gestational age <28 weeks (OR=5.570, 95% CI 1.866 to 16.430), age at NICU admission (OR=0.959, 95% CI 0.918 to 0.989), and a maximum FiO2≥35% within 72 hours post-extubation (OR=4.541, 95% CI 1.849 to 10.980) as independent risk factors for extubation failure (all P<0.05). Additionally, the failed extubation group exhibited significantly higher incidences of necrotizing enterocolitis grade II or above, moderate-to-severe bronchopulmonary dysplasia, severe bronchopulmonary dysplasia, retinopathy of prematurity, treatment abandonment due to poor prognosis, and discharge on home oxygen therapy (all P<0.05). Total hospital length of stay and total hospitalization costs were also significantly increased in the failed extubation group (all P<0.05).
CONCLUSIONS
Gestational age <28 weeks, younger age at NICU admission, and FiO2≥35% after extubation are high-risk factors for first extubation failure in neonates. Extubation failure markedly increases the risk of adverse clinical outcomes.
Humans
;
Infant, Newborn
;
Male
;
Female
;
Airway Extubation/adverse effects*
;
Risk Factors
;
Retrospective Studies
;
Respiration, Artificial/methods*
;
Intensive Care Units, Neonatal
;
Prognosis
;
Gestational Age
;
Bronchopulmonary Dysplasia
;
Infant, Premature
;
Treatment Failure
;
Intubation, Intratracheal
2.A self-controlled study on endotracheal tube cuff pressure management modes.
Yanxin LIU ; Yanhong GAO ; Xingli ZHAO ; Hongxia LI ; Baojun SUN ; Xiangqun FANG ; Zhijian ZHANG
Chinese Critical Care Medicine 2025;37(4):348-353
OBJECTIVE:
To explore the effects of different endotracheal tube cuff pressure management modes on cuff sealing and the pressure exerted on the tracheal wall.
METHODS:
A prospective self-controlled study was conducted. Eleven patients undergoing endotracheal intubation and mechanical ventilation with an automatic airway management system (AGs) admitted to the Second Medical Centre of the Chinese People's Liberation Army General Hospital from October 1, 2020, to April 1, 2022, were enrolled as the study subjects. Within 24 hours after the establishment of artificial airway and mechanical ventilation, four cuff pressure management modes were randomly applied to each patient for 24 hours in sequence: automatic cuff pressure management mode [modeI: the safe range of cuff pressure was set at 20-35 cmH2O (1 cmH2O≈0.098 kPa), and the CO2 pressure above the endotracheal tube cuff was automatically detected by AGs every 5 minutes to determine the cuff sealing status, and the cuff pressure was automatically adjusted], constant cuff pressure (25 cmH2O) management mode (mode II: the cuff pressure was monitored by AGs through a pressure sensor, and the cuff pressure was maintained at 25 cmH2O via a pressure pump), constant cuff pressure (30 cmH2O) management mode (mode III: the cuff pressure was monitored by AGs through a pressure sensor, and the cuff pressure was maintained at 30 cmH2O via a pressure pump), and manual cuff pressure management mode (mode IV: the cuff pressure was manually measured by nurses every 6-8 hours using a cuff pressure gauge to keep the cuff pressure at 25-30 cmH2O after inflation). The CO2 pressure above the endotracheal tube cuff (at 60-minute intervals) and the cuff pressure changes (at 50-ms intervals) were recorded to compare the differences in number of cuff leaks [no leak was defined as CO2 pressure = 0, small leak as 0 < CO2 pressure < 2 mmHg (1 mmHg≈0.133 kPa), and large leak as CO2 pressure ≥ 2 mmHg] and cuff pressure among modesI-IV.
RESULTS:
A total of 24 CO2 pressure measurements were taken per patient across the four modes, resulting in a total of 264 detections for each mode. Regarding the cuff leak, the total number of leak and large leak in modeIwas significantly lower than that in modes II-IV [total leak: 30 cases (11.36%) vs. 81 cases (30.68%), 70 cases (26.52%), 103 cases (39.02%); large leak: 15 cases (5.68%) vs. 50 cases (18.94%), 48 cases (18.18%), 66 cases (25.00%), all P < 0.05]. There was no significant difference in the number of cuff leak between modes II and III, and mode IV had the most severe cuff leak. In terms of cuff pressure, since mode IV required blocking the cuff tube from the AGs tube and the AGs cuff pressure management module did not actually work, real-time monitoring of cuff pressure was not possible. Therefore, cuff pressure changes were only analyzed in modes I-III. Each of the 11 patients underwent 24-hour cuff pressure monitoring under modes I-III, with 19 008 000 monitoring times for each mode. The cuff pressure in mode I was between that in modes II and III [cmH2O: 27.09 (26.10, 28.14) vs. 26.60 (25.92, 27.47), 31.01 (30.33, 31.88), both P < 0.01]. Moreover, the number of extreme values of cuff pressure > 50 cmH2O in mode I was significantly lower than that in modes II and III [19 900 cases (0.105%) vs. 22 297 cases (0.117%), 27 618 cases (0.145%), both P < 0.05].
CONCLUSION
Dynamically monitoring the CO2 pressure above the cuff to guide the adjustment of endotracheal tube cuff pressure can achieve better cuff sealing with a relatively lower cuff pressure load.
Humans
;
Intubation, Intratracheal/instrumentation*
;
Pressure
;
Prospective Studies
;
Respiration, Artificial
;
Male
;
Airway Management/methods*
;
Female
;
Middle Aged
3.Design and application of a nasogastric tube auxiliary pushing device and intubation kit.
Qiao HE ; Xiaoyun ZHANG ; Yinfen XIAO ; Hua HUANG ; Junyao FAN
Chinese Critical Care Medicine 2025;37(8):771-773
As a common clinical treatment technique, nasogastric tube insertion plays an important role in assisting in disease diagnosis and treatment, and promoting patient recovery. Nasogastric tubes currently used in clinical practice are packaged individually without accompanying sterile materials, hence additional materials need to be prepared before operation, which is complicated and prone to omission, consumes clinical manpower, and increases the proportion of departmental consumption. The operator needs to hold the nasogastric tube with one hand and place it with the other hand during operation, the lack of auxiliary tool for uniformly controlling the placement of gastric tubes may easily lead to tube failure due to patient intolerance, agitation, or uneven force exerted by the operator, and improper force may even result in violent tube placement, leading to adverse outcomes such as mucosal bleeding and aspiration into the airway. Medical staff of intensive care unit of department of infectious diseases of Tongji Hospital, Tongji Medical College of Huazhong University of Science and Technology have designed a nasogastric tube auxiliary pushing device and an intubation kit to overcome the above problems, and obtaining National Utility Model Patent of China (patent number: ZL 2024 2 0300856.X). The device consists of two parts: a nasogastric tube auxiliary pushing device and a nasogastric tube insertion kit. Nasogastric tube auxiliary pushing device mainly consists of a nasogastric tube with guide wire, a circular wire harness, and a booster base with a pushing element. The tube insertion kit includes sterile treatment trays, main placement slots, and other operational accessory slots. The new nasogastric tube auxiliary pushing device and tube insertion kit integrates packaging and portable design, providing stable and uniform assistance for safe insertion of nasogastric tubes by a single person, which is able to reduce the occurrence of complications, ensure patient safety, improve patient comfort, and reduce occupational exposure risks, making it suitable for clinical promotion.
Intubation, Gastrointestinal/methods*
;
Equipment Design
;
Humans
4.The evolution of approach in the resuscitation of neonates born with meconium-stained amniotic fluid: a tale of two countries, China and U.S.A., in the past 60 years.
Hai-Bo HUANG ; Xiao-Yu ZHU ; Po-Yin CHEUNG
Chinese Journal of Contemporary Pediatrics 2023;25(3):229-237
Neonates born through meconium-stained amniotic fluid (MSAF) may develop complications including meconium aspiration syndrome, persistent pulmonary hypertension of newborn and death. The approach to the resuscitation of these neonates has significantly evolved for the past few decades. Initially, under direct visualization technique, neonates with MSAF were commonly suctioned below the vocal cords soon after delivery. Since 2015, Neonatal Resuscitation Program (NRP®) of the American Academy of Pediatrics has recommended against "routine" endotracheal suctioning of non-vigorous neonates with MSAF but favored immediate resuscitation with positive pressure ventilation via face-mask bagging. However, the China neonatal resuscitation 2021 guidelines continue to recommend routine endotracheal suctioning of non-vigorous neonates born with MSAF at birth. This review article discusses the differences and the rationales in the approach in the resuscitation of neonates with MSAF between Chinese and American NRP® guidelines over the past 60 years.
Female
;
Infant, Newborn
;
Humans
;
Child
;
Meconium Aspiration Syndrome/therapy*
;
Meconium
;
Resuscitation
;
Amniotic Fluid
;
Intubation, Intratracheal/methods*
;
Infant, Newborn, Diseases
;
China
5.Application and Research Progress of Video Double-lumen Tube in Thoracic Surgery.
Cheng SHEN ; Peng LIANG ; Guowei CHE
Chinese Journal of Lung Cancer 2022;25(8):622-626
The rapid development and promotion of minimally invasive thoracic surgery represented by video-assisted thoracoscopy surgery has gradually replaced traditional thoracic surgery technique as the primary choice for the treatment of pulmonary nodules, including early lung cancer. With the clinical application of double-lumen bronchial catheters, the realization of one-lung ventilation technology not only provides a solid anesthesia foundation for the popularization of minimally invasive thoracic surgery, but also provides a guarantee for the rapid and smooth implementation of the operation. However, compared with single-lumen bronchial catheters, the diameter of the double-lumen bronchial catheter is thicker, and the tube body is hard and difficult to shape, which brings inconvenience to anesthesia intubation. The bronchial structure is different, and the incidence of dislocation during anesthesia intubation is also high. With the gradual clinical use of video double-lumen tube (VDLT), it has become a hot spot in thoracic surgery in recent years. This article reviews the application and research progress of VDLT in thoracic surgery.
.
Humans
;
Intubation, Intratracheal/methods*
;
Lung Neoplasms/surgery*
;
One-Lung Ventilation/methods*
;
Thoracic Surgery
;
Thoracic Surgery, Video-Assisted/methods*
6.Infection Prevention Strategy in Operating Room during Coronavirus Disease 2019 (COVID-19) Outbreak.
Yi TIAN ; Ya Hong GONG ; Pei Yu LIU ; Sheng WANG ; Xiao Han XU ; Xiao Yue WANG ; Yu Guang HUANG
Chinese Medical Sciences Journal 2020;35(2):114-120
A novel coronavirus that emerged in late 2019 rapidly spread around the world. Most severe cases need endotracheal intubation and mechanical ventilation, and some mild cases may need emergent surgery under general anesthesia. The novel coronavirus was reported to transmit via droplets, contact and natural aerosols from human to human. Therefore, aerosol-producing procedures such as endotracheal intubation and airway suction may put the healthcare providers at high risk of nosocomial infection. Based on recently published articles, this review provides detailed feasible recommendations for primary anesthesiologists on infection prevention in operating room during COVID-19 outbreak.
Anesthesiologists
;
standards
;
Betacoronavirus
;
Coronavirus Infections
;
epidemiology
;
prevention & control
;
transmission
;
Cross Infection
;
epidemiology
;
prevention & control
;
transmission
;
Disease Outbreaks
;
prevention & control
;
Humans
;
Intubation, Intratracheal
;
methods
;
standards
;
Operating Rooms
;
methods
;
standards
;
Pandemics
;
prevention & control
;
Pneumonia, Viral
;
epidemiology
;
prevention & control
;
transmission
7.Establishment and clinical application of modified endoscopic freka trelumina placement.
Yankang FENG ; Ming CUI ; Yun HE ; Xilong ZHAO
Chinese Journal of Gastrointestinal Surgery 2019;22(1):79-84
OBJECTIVE:
To establish a modified endoscopic Freka Trelumina placement (mEFTP) for modifying or substituting the traditional endoscopic Freka Trelumina placement (EFTP) and to explore the safety and feasibility of mEFTP in patients requiring enteral nutrition and gastrointestinal decompression in general surgery.
METHODS:
A retrospective cohort study was conducted to analyze the clinical data of patients undergoing EFTP or mEFTP at General Surgery Department of 920 Hospital of the Joint Logistics Support Force of the Chinese People's Liberation Army from January 2016 to January 2018.
INCLUSION CRITERIA:
the function of lower digestive tract was normal; patients who could not eat through mouth or nasogastric tube needed to have enteral nutrition and gastrointestinal decompression; the retention time of Freka Trelumina (FT) was not expected to exceed 2 months.
EXCLUSION CRITERIA:
contraindication for gastroscopy; suspected shock or digestive tract perforation; suspected mental diseases; infectious diseases of digestive tract; thoracoabdominal aortic aneurysm. mEFIP procedure was as follow. FT was inserted into stomach through one side nasal cavity, gastroscope was inserted into stomach cavity, and the front part of FT was clamped with biopsy forceps through biopsy hole. Biopsy forceps and FT were inserted into the pylorus or anastomosis under gastroscope, and they were pushed into the duodenum or output loop. During pushing, the gastroscope did not pass through the duodenum or output loop. The biopsy forceps was released and pushed out, and FT was pushed with biopsy forceps synchronously into the duodenum or output loop more than 5 cm. The foreign body forceps was inserted through the biopsy hole, and the FT tube was held in the stomach and pushed to the duodenum or output loop. The previous steps repeated until the suction cavity reached the pylorus or anastomosis. The gastroscope was exited gently; the guide wire was pulled out slowly. EFTP procedure: foreign body forceps was used to clamp the front part of FT, and gastroscope, foreign body forceps and FT pass the pylorus or anastomosis simultaneously to reach the descendent duodenum or output loop as a whole. The time of catheterization was recorded and position of FT was examined by X-ray within 1 h after catheterization. The success rate of catheterization and morbidity of complications after catheterization were evaluated and compared between the two groups.
RESULTS:
A total of 141 patients were enrolled, 72 in the mEFTP group and 69 in the EFTP group. In mEFTP group, 45 cases were males and 27 were females with an average age of 55.8(37-76) years; 27 cases had normal upper gastrointestinal anatomy (postoperative gastroplegia syndrome due to colon cancer in 17 cases, due to rectal cancer in 10 cases) and 45 had upper gastrointestinal anatomic changes (gastric cancer with pylorus obstruction in 18 cases and anastomotic block after gastroenterostomy in 27 cases). In the EFTP group, 41 were males and 28 were females with an average age of 55.3(36-79) years; 33 cases had normal upper gastrointestinal anatomy (postoperative gastroplegia syndrome due to colon cancer in 20 cases, due to rectal cancer in 13 cases) and 36 had upper gastrointestinal anatomic changes (gastric cancer with pylorus obstruction in 15 cases and anastomotic block after gastroenterostomy in 21 cases). In patients with normal upper digestive tract anatomy, the average catheterization time of mEFTP was (4.9±1.7) minutes which was shorter than (7.6±1.7) minutes of EFTP(t=6.683, P<0.001). In patients of gastric cancer with pyloric obstruction, the average catheterization time of mEFTP was (6.6±1.6) minutes which was shorter than (10.5±2.6) minutes of EFTP (t=4.724, P<0.001). In patients with anastomotic block after gastroenterostomy, the average catheterization time of mEFTP was (11.3±2.5) minutes which was shorter than (15.1±3.5) minutes of EFTP (t=4.513, P<0.001). In patients with normal upper gastrointestinal anatomy, there were no significant differences in the success rate of catheterization and the morbidity of catheterization complication between mEFTP and EFTP (all P>0.05). In patients with upper gastrointestinal anatomic changes, the success rate of catheterization in mEFTP was even higher than that in EFTP, but the difference was not significant [97.8%(41/45) vs. 86.1%(31/36), χ²=2.880, P=0.089]; while the morbidity of catheterization complication in mEFTP was lower than that in EFTP [0 vs. 8.3%(3/36), χ²=3.894, P=0.048].
CONCLUSIONS
Whether the upper gastrointestinal anatomy is normal or not, mEFTP presents shorter catheterization time, higher success catheterization rate than EFTP, and is safety. mEFTP can be widely applied to clinical practice for patients requiring enteral nutrition and gastrointestinal decompression.
Adult
;
Aged
;
Decompression, Surgical
;
instrumentation
;
methods
;
Enteral Nutrition
;
instrumentation
;
methods
;
Female
;
Gastric Outlet Obstruction
;
etiology
;
surgery
;
Gastroparesis
;
etiology
;
surgery
;
Gastroscopy
;
instrumentation
;
methods
;
Humans
;
Intubation, Gastrointestinal
;
instrumentation
;
methods
;
Male
;
Middle Aged
;
Retrospective Studies
;
Stomach Diseases
;
etiology
;
surgery
8.Impacts of Different Nostril for Nasotracheal Intubation with Video Laryngoscopy.
Lei WANG ; Jing Hu SUI ; Xiao Ming DENG ; Wen Li XU ; Ke Yu CHEN ; Ling Xin WEI ; Dong YANG
Acta Academiae Medicinae Sinicae 2019;41(3):379-382
Objective To compare the impacts of different nostril on nasotracheal intubation with video laryngoscopy.Methods Totally 120 ASA grade I maxillofacial surgery patients were equally randomized into two groups:group A(left nostril)and group B(right nostril).After rapid induction of anesthesia,the nasal intubation was completed by Tosight video laryngoscope,and the success rate of the first attempt of the tube passing through the nasal cavity was recorded and compared between these two groups.In addition,time of tube through nasal cavity,time of glottis exposure,total intubation time,intubation success rate,and nasal bleeding were recorded.Results The success rate of the first attempt of tube passing through the nasal cavity was not significantly different between groups A and B(84.7% . 81.7%;=0.202,=0.653).The time of tube passing through nasal cavity [(7.3±4.6)s .(7.5±4.1)s;=-0.223,=0.824] and the time of glottic exposure [(6.6±1.4)s .(6.7±1.4)s;=-0.348,=0.728] had no significant differences between two groups.The success rates of first intubation attempt were 100% in both groups.The total intubation time was(35.1±9.2)s in group A and(34.0±7.8)s in group B(=0.663,=0.509).Intubation-related epistaxis was found in 16 cases(27.1%)in group A and in 17 cases(28.3%)in group B( =0.022,=0.882).Conclusion Different nasal approaches have no effect on nasal intubation.
Glottis
;
Humans
;
Intubation, Intratracheal
;
methods
;
Laryngoscopes
;
Laryngoscopy
;
Nasal Cavity
;
Oral Surgical Procedures
9.Disruptive innovators in anaesthesia: data and devices.
Singapore medical journal 2019;60(3):108-109
10.Fibreoptic intubation in airway management: a review article.
Jolin WONG ; John Song En LEE ; Theodore Gar Ling WONG ; Rehana IQBAL ; Patrick WONG
Singapore medical journal 2019;60(3):110-118
Since the first use of the flexible fibreoptic bronchoscope, a plethora of new airway equipment has become available. It is essential for clinicians to understand the role and limitations of the available equipment to make appropriate choices. The recent 4th National Audit Project conducted in the United Kingdom found that poor judgement with inappropriate choice of equipment was a contributory factor in airway morbidity and mortality. Given the many modern airway adjuncts that are available, we aimed to define the role of flexible fibreoptic intubation in decision-making and management of anticipated and unanticipated difficult airways. We also reviewed the recent literature regarding the role of flexible fibreoptic intubation in specific patient groups who may present with difficult intubation, and concluded that the flexible fibrescope maintains its important role in difficult airway management.
Airway Management
;
methods
;
Airway Obstruction
;
complications
;
Anesthesia
;
methods
;
Bronchoscopy
;
methods
;
Equipment Design
;
Fiber Optic Technology
;
Humans
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngoscopes
;
Manikins
;
Obesity
;
complications
;
Respiratory System
;
Skull Fractures
;
complications

Result Analysis