1.Intubaiton with electromyographic endotracheal tube increases risks of postoperative sore throat following thyroidectomy under general anesthesia: a retrospective cohort study.
Lihong CHEN ; Yafen CHEN ; Huilin XIE ; Yancheng HUANG ; Yabin HUANG ; Sanqing JIN
Journal of Southern Medical University 2025;45(11):2511-2517
OBJECTIVES:
To investigate the effect of intubation with electromyographic (EMG) endotracheal tubes versus conventional wire-reinforced (CWR) tubes on the incidence of postoperative sore throat (POST) in patients undergoing thyroidectomy under general anesthesia and identify the risk factors for POST.
METHODS:
We retrospectively collected the clinical data from a cohort of 245 patients undergoing elective thyroid surgery under general anesthesia at the Sixth Affiliated Hospital of Sun Yat-sen University between October, 2024 and March, 2025. Patients received intubation with either EMG endotracheal tubes (n=100) or CWR tubes (n=145) during the operation, and the incidences of POST and other postoperative complications were compared between the two groups. Propensity score matching (PSM) was applied to adjust for the baseline differences, and multivariate logistic regression analysis was used to identify independent risk factors for POST.
RESULTS:
Comparisons of the baseline data revealed significant differences between the two groups (P<0.05). After PSM, 90 patients in EMG group and 75 in CWR group were included in the final analysis with matching baseline characteristics (P>0.05). Post-matching analysis showed that the EMG group had a shorter operative time (P=0.002) but a higher incidence of POST (P=0.001). Multivariate logistic regression identified the use of EMG tubes (OR=17.50, 95% CI: 2.25-136.03, P<0.01) as an independent risk factor for POST.
CONCLUSIONS
Intubation with EMG endotracheal tubes can shorten the operative time and allow recurrent laryngeal nerve monitoring during thyroidectomy under general anesthesia, but their structural design may increase the risk of POST. Clinical decisions should be made to balance nerve protection and postoperative patient comfort by selecting appropriate tube types and optimizing intubation strategies to enhance perioperative outcomes.
Humans
;
Retrospective Studies
;
Intubation, Intratracheal/instrumentation*
;
Thyroidectomy/adverse effects*
;
Anesthesia, General
;
Postoperative Complications/epidemiology*
;
Pharyngitis/epidemiology*
;
Electromyography
;
Risk Factors
;
Female
;
Male
;
Middle Aged
;
Adult
;
Incidence
2.A self-controlled study on endotracheal tube cuff pressure management modes.
Yanxin LIU ; Yanhong GAO ; Xingli ZHAO ; Hongxia LI ; Baojun SUN ; Xiangqun FANG ; Zhijian ZHANG
Chinese Critical Care Medicine 2025;37(4):348-353
OBJECTIVE:
To explore the effects of different endotracheal tube cuff pressure management modes on cuff sealing and the pressure exerted on the tracheal wall.
METHODS:
A prospective self-controlled study was conducted. Eleven patients undergoing endotracheal intubation and mechanical ventilation with an automatic airway management system (AGs) admitted to the Second Medical Centre of the Chinese People's Liberation Army General Hospital from October 1, 2020, to April 1, 2022, were enrolled as the study subjects. Within 24 hours after the establishment of artificial airway and mechanical ventilation, four cuff pressure management modes were randomly applied to each patient for 24 hours in sequence: automatic cuff pressure management mode [modeI: the safe range of cuff pressure was set at 20-35 cmH2O (1 cmH2O≈0.098 kPa), and the CO2 pressure above the endotracheal tube cuff was automatically detected by AGs every 5 minutes to determine the cuff sealing status, and the cuff pressure was automatically adjusted], constant cuff pressure (25 cmH2O) management mode (mode II: the cuff pressure was monitored by AGs through a pressure sensor, and the cuff pressure was maintained at 25 cmH2O via a pressure pump), constant cuff pressure (30 cmH2O) management mode (mode III: the cuff pressure was monitored by AGs through a pressure sensor, and the cuff pressure was maintained at 30 cmH2O via a pressure pump), and manual cuff pressure management mode (mode IV: the cuff pressure was manually measured by nurses every 6-8 hours using a cuff pressure gauge to keep the cuff pressure at 25-30 cmH2O after inflation). The CO2 pressure above the endotracheal tube cuff (at 60-minute intervals) and the cuff pressure changes (at 50-ms intervals) were recorded to compare the differences in number of cuff leaks [no leak was defined as CO2 pressure = 0, small leak as 0 < CO2 pressure < 2 mmHg (1 mmHg≈0.133 kPa), and large leak as CO2 pressure ≥ 2 mmHg] and cuff pressure among modesI-IV.
RESULTS:
A total of 24 CO2 pressure measurements were taken per patient across the four modes, resulting in a total of 264 detections for each mode. Regarding the cuff leak, the total number of leak and large leak in modeIwas significantly lower than that in modes II-IV [total leak: 30 cases (11.36%) vs. 81 cases (30.68%), 70 cases (26.52%), 103 cases (39.02%); large leak: 15 cases (5.68%) vs. 50 cases (18.94%), 48 cases (18.18%), 66 cases (25.00%), all P < 0.05]. There was no significant difference in the number of cuff leak between modes II and III, and mode IV had the most severe cuff leak. In terms of cuff pressure, since mode IV required blocking the cuff tube from the AGs tube and the AGs cuff pressure management module did not actually work, real-time monitoring of cuff pressure was not possible. Therefore, cuff pressure changes were only analyzed in modes I-III. Each of the 11 patients underwent 24-hour cuff pressure monitoring under modes I-III, with 19 008 000 monitoring times for each mode. The cuff pressure in mode I was between that in modes II and III [cmH2O: 27.09 (26.10, 28.14) vs. 26.60 (25.92, 27.47), 31.01 (30.33, 31.88), both P < 0.01]. Moreover, the number of extreme values of cuff pressure > 50 cmH2O in mode I was significantly lower than that in modes II and III [19 900 cases (0.105%) vs. 22 297 cases (0.117%), 27 618 cases (0.145%), both P < 0.05].
CONCLUSION
Dynamically monitoring the CO2 pressure above the cuff to guide the adjustment of endotracheal tube cuff pressure can achieve better cuff sealing with a relatively lower cuff pressure load.
Humans
;
Intubation, Intratracheal/instrumentation*
;
Pressure
;
Prospective Studies
;
Respiration, Artificial
;
Male
;
Airway Management/methods*
;
Female
;
Middle Aged
3.Fibreoptic intubation in airway management: a review article.
Jolin WONG ; John Song En LEE ; Theodore Gar Ling WONG ; Rehana IQBAL ; Patrick WONG
Singapore medical journal 2019;60(3):110-118
Since the first use of the flexible fibreoptic bronchoscope, a plethora of new airway equipment has become available. It is essential for clinicians to understand the role and limitations of the available equipment to make appropriate choices. The recent 4th National Audit Project conducted in the United Kingdom found that poor judgement with inappropriate choice of equipment was a contributory factor in airway morbidity and mortality. Given the many modern airway adjuncts that are available, we aimed to define the role of flexible fibreoptic intubation in decision-making and management of anticipated and unanticipated difficult airways. We also reviewed the recent literature regarding the role of flexible fibreoptic intubation in specific patient groups who may present with difficult intubation, and concluded that the flexible fibrescope maintains its important role in difficult airway management.
Airway Management
;
methods
;
Airway Obstruction
;
complications
;
Anesthesia
;
methods
;
Bronchoscopy
;
methods
;
Equipment Design
;
Fiber Optic Technology
;
Humans
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngoscopes
;
Manikins
;
Obesity
;
complications
;
Respiratory System
;
Skull Fractures
;
complications
4.Prevailing practices in airway management: a prospective single-centre observational study of endotracheal intubation.
Geraldine Pei Chin CHEONG ; Anusha KANNAN ; Kwong Fah KOH ; Kumaresh VENKATESAN ; Edwin SEET
Singapore medical journal 2018;59(3):144-149
INTRODUCTIONAirway management during anaesthesia has potential difficulties and risks. We aimed to investigate the utility of routine airway assessment for predicting difficult tracheal intubation, review the prevailing practice of videolaryngoscope use amongst anaesthetists in a teaching hospital and determine the incidence of intraoperative and postoperative airway-related complications.
METHODSA prospective observational study of 1,654 patients undergoing general anaesthesia with endotracheal intubation over a seven-month period was performed. Data regarding airway and anaesthetic management was collected and analysed.
RESULTSVideolaryngoscopes were used as the first-choice equipment in 60.5% of the cohort. The incidence of difficult intubation was 2.1%, of which 45.7% of cases were unanticipated. The sensitivity of airway assessment was 54.3%, with a positive predictive value of 8.1%. When difficult intubation was anticipated, more videolaryngoscopes were used as the first equipment of choice compared to the Macintosh laryngoscope (p < 0.001). In the Macintosh group, more patients required a change of airway equipment (p = 0.015), but the number of intubation attempts was similar (p = 0.293). The incidence of intraoperative (p = 0.920) and postoperative complications (p = 0.380) were similar in both groups.
CONCLUSIONUsing the current predictors of difficult intubation, half of the difficult airways we encountered were unanticipated. Videolaryngoscopes were preferred when difficulty was anticipated and were also used in routine tracheal intubation.
Adult ; Aged ; Airway Management ; Anesthesia, General ; Anesthesiology ; education ; Humans ; Intubation, Intratracheal ; instrumentation ; Laryngoscopes ; Laryngoscopy ; Middle Aged ; Prospective Studies ; Trachea ; Video Recording
5.Evaluation of Endotracheal Intubation with a Flexible Fiberoptic Bronchoscope in Lateral Patient Positioning: A Prospective Randomized Controlled Trial.
Hui LI ; Wu WANG ; Ya-Ping LU ; Yan WANG ; Li-Hua CHEN ; Li-Pei LEI ; Xiang-Ming FANG
Chinese Medical Journal 2016;129(17):2045-2049
BACKGROUNDThere is an unmet need for a reliable method of airway management for patients in the lateral position. This prospective randomized controlled two-center study was designed to evaluate the feasibility of intubation using a flexible fiberoptic bronchoscope in the lateral position during surgery.
METHODSSeventy-two patients scheduled for elective nonobstetric surgery in the lateral decubitus position requiring tracheal intubation under general anesthesia at Lishui Central Hospital of Zhejiang Province and Jiaxing First Hospital of Zhejiang Province from April 1, 2015, to September 30, 2015, were enrolled in this study. Patients were randomly assigned to the supine position group (Group S, n = 38) and the lateral position group (Group L, n = 34). Experienced anesthetists performed tracheal intubation with a fiberoptic bronchoscope after general anesthesia. The time required for intubation, intubation success rates, and hemodynamic changes was recorded. Between-group differences were assessed using the Student's t-test, Mann-Whitney U-test, or Chi-square test.
RESULTSThe median total time to tracheal intubation was significantly longer in Group S (140.0 [135.8, 150.0] s) compared to Group L (33.0 [24.0, 38.8] s) (P < 0.01). The first-attempt intubation success rate was significantly higher in Group L (97%) compared to Group S (16%). Hemodynamic changes immediately after intubation were more exaggerated in Group S compared to Group L (P = 0.02).
CONCLUSIONEndotracheal intubation with a flexible fiberoptic bronchoscope may be an effective and timesaving technique for patients in the lateral position.
TRIAL REGISTRATIONChinese Clinical Trial Register, ChiCTR-IIR-16007814; http://www.chictr.org.cn/showproj.aspx?proj=13183.
Adult ; Aged ; Airway Management ; Bronchoscopes ; Equipment Design ; Female ; Fiber Optic Technology ; instrumentation ; methods ; Humans ; Intraoperative Complications ; prevention & control ; Intubation, Intratracheal ; instrumentation ; methods ; Male ; Middle Aged ; Patient Positioning ; Prospective Studies ; Young Adult
6.Standard versus Rotation Technique for Insertion of Supraglottic Airway Devices: Systematic Review and Meta-Analysis.
Jin Ha PARK ; Jong Seok LEE ; Sang Beom NAM ; Jin Wu JU ; Min Soo KIM
Yonsei Medical Journal 2016;57(4):987-997
PURPOSE: Supraglottic airway devices have been widely utilized as an alternative to tracheal intubation in various clinical situations. The rotation technique has been proposed to improve the insertion success rate of supraglottic airways. However, the clinical efficacy of this technique remains uncertain as previous results have been inconsistent, depending on the variable evaluated. MATERIALS AND METHODS: We systematically searched PubMed, Embase, and the Cochrane Central Register of Controlled Trials in April 2015 for randomized controlled trials that compared the rotation and standard techniques for inserting supraglottic airways. RESULTS: Thirteen randomized controlled trials (1505 patients, 753 with the rotation technique) were included. The success rate at the first attempt was significantly higher with the rotation technique than with the standard technique [relative risk (RR): 1.13; 95% confidence interval (CI): 1.05 to 1.23; p=0.002]. The rotation technique provided significantly higher overall success rates (RR: 1.06; 95% CI: 1.04 to 1.09; p<0.001). Device insertion was completed faster with the rotation technique (mean difference: -4.6 seconds; 95% CI: -7.37 to -1.74; p=0.002). The incidence of blood staining on the removed device (RR: 0.36; 95% CI: 0.27 to 0.47; p<0.001) was significantly lower with the rotation technique. CONCLUSION: The rotation technique provided higher first-attempt and overall success rates, faster insertion, and a lower incidence of blood on the removed device, reflecting less mucosal trauma. Thus, it may be considered as an alternative to the standard technique when predicting or encountering difficulty in inserting supraglottic airways.
Device Removal
;
Humans
;
Intubation, Intratracheal/instrumentation/*methods/standards
;
*Laryngeal Masks
;
Randomized Controlled Trials as Topic
;
Reference Standards
;
Risk
;
*Rotation
7.Awake tracheal intubation in a patient with a supraglottic mass with the Bonfils fibrescope after failed attempts with a flexible fibrescope.
Geoffrey LIEW ; Xin Fang LEONG ; Theodore WONG
Singapore medical journal 2015;56(8):e139-41
Awake intubation with a flexible fibrescope is usually done electively in patients with a known difficult airway. Herein, we describe the case of an elective awake tracheal intubation that was performed on a patient with a large, obstructive supraglottic mass. The intubation was successfully performed using the Bonfils fibrescope after several failed attempts with a flexible fibrescope. This case highlights the usefulness of the Bonfils fibrescope and the limitations of the flexible fibrescope in certain clinical situations.
Fiber Optic Technology
;
Humans
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngeal Neoplasms
;
diagnosis
;
Laryngoscopes
;
Laryngoscopy
;
instrumentation
;
Male
;
Middle Aged
;
Trachea
;
Tracheostomy
;
methods
;
Wakefulness
8.Comparison of cardiac output and hemodynamic responses of intubation among different videolaryngoscopies in normotensive and hypertensive patients.
Amro Faez ABDELGAWAD ; Qin-Fang SHI ; Mohamed Abo HALAWA ; Zhi-Lin WU ; Zhou-Yang WU ; Xiang-Dong CHEN ; Shang-Long YAO
Journal of Huazhong University of Science and Technology (Medical Sciences) 2015;35(3):432-438
Tracheal intubation with Macintosh laryngoscope (MAC) might result in severe cardiovascular complications. The results of conducted studies investigating the effects of videolaryngoscopies on hemodynamic response of tracheal intubation are conflicting. We know little about the effects of videolaryngoscopies on cardiac output changes during tracheal intubation. We compared cardiac output (COP) and hemodynamic responses in normal blood pressure (n=60) and hypertensive patients (n=60) among 3 intubation devices: the MAC, the UE videolaryngoscopy ® (UE), and the UE video intubation stylet ® (VS). Cardiac index (CI), stroke volume index (SVI), heart rate (HR), systolic blood pressure (SBP) and diastolic blood pressure (DBP) were recorded using LidcoRapid (V2)® preinduction, preintubation, and every minute for the first 5 min after intubation. We assessed oropharyngeal and laryngeal structures injury as well. Intubation time was significantly shorter than MAC groups (P<0.001) only in UE group of normotensive and hypertensive patients. In normotensive patients, there were no significant differences in any of COP variables or hemodynamic variables among the three devices. In hypertensive patients, SBP and DBP in the MAC group were significantly higher (P<0.05 or <0.01) than the UE and VS groups at 1, 2 and 3 min after intubation, but there were no significant differences in CI, SVI and HR among the three devices. There was no significant difference in oropharyngeal and laryngeal structures injury among all groups. It was concluded that both the UE and VS attenuate only the hemodynamic response to intubation as compared with the MAC in hypertensive patients, but not in normotensive patients.
Adult
;
Aged
;
Blood Pressure
;
physiology
;
Cardiac Output
;
physiology
;
Female
;
Hemodynamics
;
Humans
;
Hypertension
;
physiopathology
;
surgery
;
Intubation, Intratracheal
;
instrumentation
;
methods
;
Laryngoscopy
;
instrumentation
;
methods
;
Larynx
;
anatomy & histology
;
injuries
;
Male
;
Middle Aged
;
Oropharynx
;
anatomy & histology
;
injuries
;
Video-Assisted Surgery
;
methods
;
Young Adult
10.Effects of Open or Closed Suctioning on Lung Dynamics and Hypoxemia in Mechanically Ventilated Patients.
Journal of Korean Academy of Nursing 2014;44(2):149-158
PURPOSE: This study was conducted to compare effects of open and closed suctioning methods on lung dynamics (dynamic compliance, tidal volume, and airway resistance) and hypoxemia (oxygen saturation and heart rate) in mechanically ventilated patients. METHODS: This study was a cross-over repeated design. Participants were 21 adult patients being treated with endotracheal intubation using a pressure-controlled ventilator below Fraction of Inspired Oxygen (FiO2) 60% and PEEP 8 cmH2O. Data were collected at baseline and 1, 2, 3, 4, 5, and 10 minutes after suctioning. Data were analyzed using two-factor ANOVA with repeated measures on time and suctioning type. RESULTS: Effects of the interaction between suction type and time were significant for oxygen saturation and heart rate but not significant for dynamic compliance, tidal volume, or airway resistance. Prior to performance of suctioning, tidal volume and oxygen saturation were significantly lower, but airway pressure and heart rate were significantly higher using the closed suctioning method as compared with the open suctioning method. CONCLUSION: For patients on ventilator therapy below FiO2 60% and PEEP 8cmH2O, open suctioning performed after delivery of 100% FiO2 using a mechanical ventilator may not have as much negative impact on lung dynamics and hypoxemia as closed suctioning.
APACHE
;
Adult
;
Aged
;
Aged, 80 and over
;
Anoxia/*physiopathology/therapy
;
Female
;
Heart Rate/physiology
;
Humans
;
Intubation, Intratracheal
;
Lung/*physiopathology
;
Male
;
Middle Aged
;
Oxygen Consumption/physiology
;
Respiration, Artificial/*instrumentation
;
Suction

Result Analysis
Print
Save
E-mail