1.A case report of intraoperative awareness under general endotracheal anesthesia during decompressive laminectomy T3-T4.
Philippine Journal of Anesthesiology 2024;29(2):66-71
Intraoperative awareness during general anesthesia remains a significant concern. This report presents a rare case of a 40-year-old male patient, experiencing intraoperative awareness during an elective decompressive laminectomy T3–T4 for spinal cord compression secondary to an epidural abscess. Despite no comorbidities and being classified as American Society of Anesthesiologists II, the patient postoperatively reported recalling intraoperative events. Notably, intraoperative findings revealed malfunctioning of the anesthesia machine’s bellows and a vaporizer installation issue. This mishap suggests equipment failure as the potential cause of reduced anesthetic delivery. Using the Brice protocol, the patient’s claims were confirmed as he recalled specific discussions during the operation, though he reported no pain. The team acknowledged and apologized for the awareness incident, assuring patient safety. Awareness, although rare, can be distressing and might result from anesthesia underdosing, equipment failure, or anesthetic application errors. Anesthesiologists must remain vigilant, ensuring equipment functionality, considering increased anesthetic doses when safe, and promptly addressing patient claims of intraoperative awareness. Proper communication, documentation, and patient follow-up are crucial in managing these cases effectively.
Human ; Male ; Adult: 25-44 Yrs Old ; Intraoperative Awareness
2.A case report of intraoperative awareness under general endotracheal anesthesia during decompressive laminectomy T3-T4.
Philippine Journal of Anesthesiology 2024;29(2):66-71
Intraoperative awareness during general anesthesia remains a significant concern. This report presents a rare case of a 40-year-old male patient, experiencing intraoperative awareness during an elective decompressive laminectomy T3–T4 for spinal cord compression secondary to an epidural abscess. Despite no comorbidities and being classified as American Society of Anesthesiologists II, the patient postoperatively reported recalling intraoperative events. Notably, intraoperative findings revealed malfunctioning of the anesthesia machine’s bellows and a vaporizer installation issue. This mishap suggests equipment failure as the potential cause of reduced anesthetic delivery. Using the Brice protocol, the patient’s claims were confirmed as he recalled specific discussions during the operation, though he reported no pain. The team acknowledged and apologized for the awareness incident, assuring patient safety. Awareness, although rare, can be distressing and might result from anesthesia underdosing, equipment failure, or anesthetic application errors. Anesthesiologists must remain vigilant, ensuring equipment functionality, considering increased anesthetic doses when safe, and promptly addressing patient claims of intraoperative awareness. Proper communication, documentation, and patient follow-up are crucial in managing these cases effectively.
Human ; Male ; Adult: 25-44 Yrs Old ; Intraoperative Awareness
3.Awareness during general anesthesia despite simultaneous bispectral index and end-tidal anesthetic gas concentration monitoring
Jungwon LEE ; Chorong PARK ; Saeyoung KIM
Yeungnam University Journal of Medicine 2019;36(1):50-53
Awareness during general anesthesia occurs in approximately 0.1–0.2% of cases; nevertheless, particular attention is required because it can lead to critical complications including insomnia, depression, anxiety, and post-traumatic stress disorder. To prevent these complications, bispectral index (BIS) and end-tidal anesthetic gas (ETAG) concentration monitoring are commonly used to examine patient consciousness during surgery. In the present case, an 80-year-old man was scheduled for total gastrectomy. Anesthesia was maintained using desflurane 4.0–5.0% vol, oxygen, and nitrous oxide. The authors simultaneously monitored BIS, which was maintained between 37 and 43, and ETAG, which was maintained between 0.9 and 1.2 minimum alveolar concentration (MAC). After the operation, however, the authors were surprised to learn that the patient complained of awareness during anesthesia. Although BIS and ETAG concentration monitoring are useful in preventing awareness during anesthesia, they cannot be completely trusted. Even though BIS was maintained at approximately 40 and ETAG at 0.7–1.3 MAC, awareness during anesthesia occurred.
Aged, 80 and over
;
Anesthesia
;
Anesthesia, General
;
Anxiety
;
Consciousness
;
Consciousness Monitors
;
Depression
;
Gastrectomy
;
Humans
;
Intraoperative Awareness
;
Nitrous Oxide
;
Oxygen
;
Sleep Initiation and Maintenance Disorders
;
Stress Disorders, Post-Traumatic
4.Investigation into memory formation according to the level of hypnotic depth using process dissociation.
Yu Ri JUNG ; Byung Moon CHOI ; Gyu Jeong NOH
Anesthesia and Pain Medicine 2018;13(4):388-393
BACKGROUND: Process dissociation procedure has been used to evaluate explicit and implicit memories. Two process-dissociation measurement models are described. METHODS: This prospective study evaluated intraoperative memory formation in Korean patients undergoing elective surgery under general anesthesia and its relation to the depth of hypnotic state. A total of 270 patients enrolled were randomly assigned to three groups based on Bispectral Index (BIS) values in the following ranges: 30 to 40, BIS 40 to 50, and BIS 50 to 60 according to the level of hypnotic depth induced by propofol or sevoflurane during the presentation of wordlists. When the level of hypnotic depth was maintained at the target BIS range, words were played for 15 minutes via headphones to patients. Within 24 hours after the word presentation, memory was assessed using an auditory word stem completion test. The probability of explicit and implicit memory was calculated using original and extended measurement models. Brice interviews were performed within 1 and 24 hours after surgery. RESULTS: A total of 119 patients who did not deviate from the target BIS range were included in the analysis. The 95% confidence interval (CI) of the probability of occurrence of implicit memory evaluated by the original model did not include zero. However, when the extension model was used, 0 was included in the 95% CI. Explicit memory evaluated via Brice interviews did not occur in any group. CONCLUSIONS: When BIS was maintained in the range of 30 to 60 during surgery, no explicit or implicit memory was observed.
Anesthesia
;
Anesthesia, General
;
Humans
;
Intraoperative Awareness
;
Memory*
;
Propofol
;
Prospective Studies
5.Do you believe that processed EEG helps to prevent intraoperative awareness?.
Korean Journal of Anesthesiology 2018;71(6):427-429
No abstract available.
Electroencephalography*
;
Intraoperative Awareness*
6.Unexpected anesthetic leakage from a damaged O-ring on the Selectatec back bar: A case report.
Young Uk KIM ; Jimi OH ; Chan Hye PARK ; Byung Moon CHOI ; Dong Min JANG ; Ji Yeon BANG
Anesthesia and Pain Medicine 2017;12(2):183-186
The Selectatec mounting system was devised to provide easy and quick on-site fitting of various vaporizers for the anesthetic machine. However, a quick changing system for the vaporizer can also damage the O-ring due to friction between the vaporizer and the Selectatec back bar. We herein report a case of an unexpected anesthetic gas leakage from a damaged O-ring on the Selectatec back bar, which resulted from exchanging the vaporizers between two operations. In cases using the Datex Ohmeda machine, it is not easy to detect leakages from the vaporizers because of the location of the check valve near to the fresh gas outlet. This complicates the use of the positive pressure leakage test to detect a low pressure system leakage on the Selectatec back bar. We recommend the preanesthetic negative pressure or low-flow leakage test to detect a low pressure leakage when exchanging vaporizers on the Selectatec system.
Friction
;
Intraoperative Awareness
;
Nebulizers and Vaporizers
;
Ventilators, Mechanical
7.Mechanisms underlying brain monitoring during anesthesia: limitations, possible improvements, and perspectives.
Korean Journal of Anesthesiology 2016;69(2):113-120
Currently, anesthesiologists use clinical parameters to directly measure the depth of anesthesia (DoA). This clinical standard of monitoring is often combined with brain monitoring for better assessment of the hypnotic component of anesthesia. Brain monitoring devices provide indices allowing for an immediate assessment of the impact of anesthetics on consciousness. However, questions remain regarding the mechanisms underpinning these indices of hypnosis. By briefly describing current knowledge of the brain's electrical activity during general anesthesia, as well as the operating principles of DoA monitors, the aim of this work is to simplify our understanding of the mathematical processes that allow for translation of complex patterns of brain electrical activity into dimensionless indices. This is a challenging task because mathematical concepts appear remote from clinical practice. Moreover, most DoA algorithms are proprietary algorithms and the difficulty of exploring the inner workings of mathematical models represents an obstacle to accurate simplification. The limitations of current DoA monitors - and the possibility for improvement - as well as perspectives on brain monitoring derived from recent research on corticocortical connectivity and communication are also discussed.
Anesthesia*
;
Anesthesia, General
;
Anesthetics
;
Brain*
;
Consciousness
;
Electroencephalography
;
Hypnosis
;
Intraoperative Awareness
;
Intraoperative Neurophysiological Monitoring
;
Mathematical Concepts
;
Models, Theoretical
8.Study on the Evaluation Index of Depth of Anesthesia Awareness Based on Sample Entropy and Decision Tree.
Jun LIU ; Yaqi ZHOU ; Shaobin CHEN ; Tianhao XU ; Xiao CHEN ; Fei XIE
Journal of Biomedical Engineering 2015;32(2):434-439
Currently, monitoring system of awareness of the depth of anesthesia has been more and more widely used in clinical practices. The intelligent evaluation algorithm is the key technology of this type of equipment. On the basis of studies about changes of electroencephalography (EEG) features during anesthesia, a discussion about how to select reasonable EEG parameters and classification algorithm to monitor the depth of anesthesia has taken place. A scheme which combines time domain analysis, frequency domain analysis and the variability of EEG and decision tree as classifier and least squares to compute Depth of anesthesia Index (DOAI) is proposed in this paper. Using the EEG of 40 patients who underwent general anesthesia with propofol, and the classification and the score of the EEG annotated by anesthesiologist, we verified this scheme with experiments. Classification and scoring was based on a combination of modified observer assessment of alertness/sedation (MOAA/S), and the changes of EEG parameters of patients during anesthesia. Then we used the BIS index to testify the validation of the DOAI. Results showed that Pearson's correlation coefficient between the DOAI and the BIS over the test set was 0.89. It is demonstrated that the method is feasible and has good accuracy.
Algorithms
;
Anesthesia, General
;
Decision Trees
;
Electroencephalography
;
Entropy
;
Humans
;
Intraoperative Awareness
;
Monitoring, Physiologic
;
Propofol
9.Anesthesia awareness. Can midazolam attenuate or prevent memory consolidation on intraoperative awakening during general anesthesia without increasing the risk of postoperative delirium?.
Korean Journal of Anesthesiology 2015;68(2):200-202
No abstract available.
Anesthesia, General*
;
Delirium*
;
Intraoperative Awareness*
;
Memory*
;
Midazolam*
10.Effect of beach chair position on bispectral index values during arthroscopic shoulder surgery.
Sang Wook LEE ; Soo Eun CHOI ; Jin Hee HAN ; Sung Wook PARK ; Wha Ja KANG ; Young Kyoo CHOI
Korean Journal of Anesthesiology 2014;67(4):235-239
BACKGROUND: Bispectral index (BIS) monitoring reduces the cases of intraoperative awareness. Several factors can alter BIS readings without affecting the depth of anesthesia. We conducted a study to assess the impact of beach chair position (sitting position) on BIS readings. METHODS: General anesthesia was administered to 30 patients undergoing arthroscopic shoulder surgery. Patients were kept in neutral position (supine) for 10 minutes and BIS readings, mean arterial blood pressure, heart rate, end-tidal carbon dioxide, and end-tidal sevoflurane were recorded. Patients were then shifted to beach chair position. After 15 minutes, data were recorded. RESULTS: A significant decrease in BIS values (P < 0.01) associated with a position change from neutral position to beach chair position was evident. CONCLUSIONS: BIS values are significantly decreased in the beach chair position compared with the neutral position and might affect interpretation of the depth of anesthesia.
Anesthesia
;
Anesthesia, General
;
Arterial Pressure
;
Carbon Dioxide
;
Heart Rate
;
Humans
;
Intraoperative Awareness
;
Reading
;
Shoulder*