1.Biomechanical advantages of personalized Y-shaped plates in treatment of distal humeral intra-articular fractures.
Hao YU ; Jiachen PENG ; Jibin YANG ; Lidan YANG ; Zhi XU ; Chen YANG
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(5):574-583
OBJECTIVE:
To compare the biomechanical properties of personalized Y-shaped plates with horizontal plates, vertical plates, and traditional Y-shaped plates in the treatment of distal humeral intra-articular fractures through finite element analysis, and to evaluate their potential for clinical application.
METHODS:
The study selected a 38-year-old male volunteer and obtained a three-dimensional model of the humerus by scanning his upper limbs using a 64-slice spiral CT. Four types of fracture-internal fixation models were constructed using Mimics 19.0, Geomagic Wrap 2017, Creo 6.0, and other software: horizontal plates, vertical plates, traditional Y-shaped plate, and personalized Y-shaped plate. The models were then meshed using Hypermesh 14.0 software, and material properties and boundary conditions were defined in Abaqus 6.14 software. AnyBody 7.3 software was used to simulate elbow flexion and extension movements, calculate muscle strength, joint forces, and load torques, and compare the peak stress and maximum displacement of the four fixation methods at different motion angles (10°, 30°, 50°, 70°, 90°, 110°, 130°, 150°) during elbow flexion and extension.
RESULTS:
Under dynamic loading during elbow flexion and extension, the personalized Y-shaped plate exhibits significant biomechanical advantages. During elbow flexion, the peak internal fixation stress of the personalized Y-shaped plate was (28.8±0.9) MPa, which was significantly lower than that of the horizontal plates, vertical plates, and traditional Y-shaped plate ( P<0.05). During elbow extension, the peak internal fixation stress of the personalized Y-shaped plate was (18.1±1.6) MPa, which was lower than those of the other three models, with significant differences when compared with horizontal plates and vertical plates ( P<0.05). Regarding the peak humeral stress, the personalized Y-shaped plate model showed mean values of (10.9±0.8) and (13.1±1.4) MPa during elbow flexion and extension, respectively, which were significantly lower than those of the other three models ( P<0.05). Displacement analysis showed that the maximum displacement of the humerus with the personalized Y-shaped plate during elbow flexion was (2.03±0.08) mm, slightly higher than that of the horizontal plates, but significantly lower than that of the vertical plates, showing significant differences ( P<0.05). During elbow extension, the maximum displacement of the humerus with the personalized Y-shaped plate was (1.93±0.13) mm, which was lower than that of the other three models, with significant differences when compared with vertical plates and traditional Y-shaped plates ( P<0.05). Stress contour analysis showed that the stress of the personalized Y-shaped plate was primarily concentrated at the bifurcation of the Y-shaped structure. Displacement contour analysis showed that the personalized Y-shaped plate effectively controlled the displacement of the distal humerus during both flexion and extension, demonstrating excellent stability.
CONCLUSION
The personalized Y-shaped plate demonstrates excellent biomechanical performance in the treatment of distal humeral intra-articular fractures, with lower stress and displacement, providing more stable fixation effects.
Humans
;
Male
;
Adult
;
Healthy Volunteers
;
Finite Element Analysis
;
Tomography, Spiral Computed
;
Models, Anatomic
;
Biomechanical Phenomena
;
Humeral Fractures, Distal/surgery*
;
Fracture Fixation, Internal/instrumentation*
;
Bone Plates
;
Computer Simulation
;
Precision Medicine/methods*
;
Elbow Joint/surgery*
;
Elbow/surgery*
;
Humerus/surgery*
;
Torque
;
Stress, Mechanical
;
Intra-Articular Fractures/surgery*
;
Prosthesis Design/methods*
;
Imaging, Three-Dimensional
;
Range of Motion, Articular
3.The flexibility and convenience of using a standard orthopaedic table in peri-articular knee fractures: Allowing ligamentotaxis and improving imaging accessibility.
Zaid AL-ANI ; Shaival S DALAL ; Amit CHANDRATREYA ; Khalid SHARIF ; Sarvpreet SINGH
Chinese Journal of Traumatology 2022;25(6):375-378
Tibial plateau and distal femoral fractures are common injuries presenting a significant operative challenge. Complexity of the fracture often needs multi-planar surgical access. A combined two-staged procedure is frequently suggested both in supine and prone position to address this issue. However, this will significantly increase the operative time and eventually impact the outcome, in addition to the complications associated with prone positioning. In this study we used a standard orthopaedic table to position these patients in order to grant access to the postro-medial and a postro-lateral structures while the patient stays in supine setup, at the same time, giving the flexibility to change the alignment from valgus to varus and vice versa. This facilitates fracture reduction while addressing the anatomical structure of the knee. A further advantage is the unobstructed imaging access throughout the surgical fixation. This facilitates the reduction in operative time hence leading to a better outcome in these difficult fractures. We tested this positioning technique in more than 40 patients over a 4-year period at two different centres in the United Kingdome. We found that this approach is safe, reproducible and relatively easy to set up in the two centres.
Humans
;
Tibial Fractures/surgery*
;
Orthopedics
;
Fracture Fixation, Internal/methods*
;
Intra-Articular Fractures/surgery*
;
Knee Injuries/surgery*
;
Knee Joint/surgery*
;
Treatment Outcome
5.Comparative study on curative effect of minimally invasive locking plate for the treatment of intra-articular calcaneal fractures via sinus tarsi approach.
Jiong-Ming YOU ; Yin-Sheng WU ; Feng WANG ; Feng LI ; Yong WANG
China Journal of Orthopaedics and Traumatology 2021;34(9):794-800
OBJECTIVE:
To compare clinical efficacy of minimally invasive locking plate and anatomic locking plate in treating intra-articular calcaneal fractures via sinus tarsi approach.
METHODS:
A retrospective analysis was conducted of 48 patients with intra-articular calcaneal fractures treated with surgery via sinus tarsi approach from July 2016 to June 2017. According to differernt methods of internal fixation, the patients were divided into minimally invasive locking plate group and anatomic locking plate group. In minimally invasive locking plate group, there were 14 males and 10 females, aged from 27 to 46 years old with an average age of (38.70±5.58) years old, 18 patients were typeⅡand 6 patients were type Ⅲ according to Sanders classification. In anatomic locking plate group, there were 17 males and 7 females, aged from 26 to 46 years old with an average age of (37.10±6.44) years old, 16 patients were typeⅡ and 8 patients were type Ⅲ according to Sanders classification. Operative time, visual analogue scale (VAS), postoperative complications between two groups were compared, and Böhler angle, Gissane angal, calcaneal width and height were recorded and compared between two groups at 1 week after operation and final follow up. The functional effect was assessed according to Maryland foot function score at final follow up.
RESULTS:
All patients were followed up for (14.10±1.94) months (ranged 12 to 18 months). All patients were obtained bone union from 8 to 16 weeks with an average of (10.60±2.25) weeks. Operation time, VAS score and complication rate in minimally invasive locking plate group were (69.50±7.51) min, (2.80±1.07) and 2 cases respectively, and (77.50±7.15) min, (3.80±1.09) and 8 cases in anatomic locking plate group respectively, there were statistical difference between two groups (
CONCLUSION
Compare with anatomic locking plate, minimally invasive locking plate via sinus tarsi approach for Sanders typeⅡ and Ⅲ intra-articular calcaneal fractures could obtain similar reliable fixation and functional recovery with more simple operation, shorter operative time, lighter postoperative pain and less complications.
Adult
;
Aged
;
Bone Plates
;
Calcaneus/surgery*
;
Female
;
Fracture Fixation, Internal
;
Fractures, Bone/surgery*
;
Heel
;
Humans
;
Intra-Articular Fractures/surgery*
;
Male
;
Middle Aged
;
Retrospective Studies
;
Treatment Outcome
6.Surgical Treatment of Pediatric Intra-Articular Proximal Phalangeal Head Fracture of the Big Toe
Yeun Soo KIM ; Geunwu GIMM ; Il ung HWANG ; Goo Hyun BAEK ; Jihyeung KIM
Journal of the Korean Fracture Society 2020;33(1):9-15
PURPOSE: Pediatric intra-articularproximal phalangeal head fractures of the big toe are very rare and few studies on this have been published. The purpose of this study is to present the diagnostic approach and surgical management of these extremely rare fractures, which might be easily underestimated or misdiagnosed.MATERIALS AND METHODS: The study retrospectively reviewed all the patients who were diagnosed as intra-articular proximal phalangeal head fracture of the big toe and who underwent surgical intervention in our institution. The size of the bony fragment and hallux valgus interphalangeus angle were measured on the preoperative X-rays. The size and rotation of the osteochondral fragment, the presence of avascular necrosis, ligamentous injury and soft tissue entrapment were assessed on the preoperative magnetic resonance images (MRIs). The radiologic and functional evaluation were performed at 1 year postoperatively.RESULTS: The average size of the bony fragments measured on the X-rays was 4.1 mm in width and 2.3 mm in length. Two cases showed hallux valgus interphalangeus. Preoperative MRI was performed in four cases and the average size of any osteochondral lesion was 5.3 mm in width, 3.9 mm in length, and 4.7 mm in height. Rotation of the osteochondral fragment was observed in one patient, and soft tissue entrapment was noted in two patients. Postoperatively, successful bony union was achieved in all the patients and the average time to union was 74.4 days.CONCLUSION: Intra-articular proximal phalangeal head fractures of the big toe are very rare and often neglected due to incomplete ossification in the pediatric population. It is important to suspect the presence of this intra-articular fracture and to appropriately implement further evaluation. Nonunion of chronic cases as well as acute fractures can be successfully treated through open reduction and internal fixation using multiple K-wires.
Hallux Valgus
;
Hallux
;
Head
;
Humans
;
Intra-Articular Fractures
;
Ligaments
;
Magnetic Resonance Imaging
;
Necrosis
;
Retrospective Studies
7.Surgical Treatment Strategy for Distal Humerus Intra-articular Fractures
Journal of the Korean Shoulder and Elbow Society 2019;22(2):113-117
Treating distal humerus fractures, especially those involving intra-articular lesions, is complex and often technically demanding. Although there still exist many controversial issues, the goal of treatment is to establish anatomical stable fixation by restoring the two columns and the articular surface. Universally, a posterior midline incision is applied, and the approach varies according to the further management of the triceps or olecranon. Evidence supports dual plate fixation as the optimal fixation method, and debates regarding appropriate plating configuration are still ongoing. As multiple clinical studies comparing results of parallel and perpendicular plate fixation have shown no actual difference, it is important to place the plates according to the fracture configuration.
Fracture Fixation
;
Humerus
;
Intra-Articular Fractures
;
Methods
;
Olecranon Process
8.Paratricipital Approach for AO/OTA Type C2 Intra-Articular Fracture of Distal Humerus
Chul Hyung LEE ; Doo Hun SUN ; Deukhee JUNG ; Chung Han AN
Journal of the Korean Fracture Society 2019;32(3):128-134
PURPOSE: The aim of this study was to determine the outcomes of fixation of AO/OTA type C2 fractures among intra-articular fractures of the distal humerus using the paratricipital approach (side to side retraction of the triceps). MATERIALS AND METHODS: From June 2008 to January 2018, 12 patients underwent an open reduction and internal fixation with the paratricipital approach and were followed-up for more than 10 months after surgery. According to the AO/OTA classification, type C2 fractures were chosen among the intraarticular distal humerus fractures. An extended posterior incision was used over the olecranon in the prone position, preserving the insertion site of the triceps brachii muscle. The fracture site was exposed by retracting the muscle side-to side through a dissection of the medial and lateral intermuscular septum of the triceps brachii muscle. The therapeutic results were assessed by the anatomical reduction of the articular surface and integrity of the metaphyseal contour in postoperative simple radiographs, complications, such as neuropathy or non-union, and the Mayo elbow performance score (MEPS) were checked to estimate the functional outcome. RESULTS: In the postoperative simple radiographs, no case showed more than 1 mm step-off and the disrupted contour of the distal humerus was recovered to normal alignment in most cases. The range of elbow joint motion in the last follow-up was 133.8° on average with a mean flexion contracture of 5.0°. The clinical results depending on the MEPS were excellent, except for two cases, which were good. Neuropathy of the ulnar nerve was observed in one patient, which was resolved after metal removal. CONCLUSION: The paratricipital approach is useful technique in AO/OTA type C2 intra-articular distal humerus fractures that provides sufficient exposure of the surgical field, without injury to the triceps brachii muscle and postoperative complications associated with the trans-olecranon approach.
Classification
;
Contracture
;
Elbow
;
Elbow Joint
;
Follow-Up Studies
;
Humans
;
Humerus
;
Intra-Articular Fractures
;
Olecranon Process
;
Postoperative Complications
;
Prone Position
;
Ulnar Nerve
9.Use of Miniplate for Severe Comminuted Metadiaphyseal Fractures of the Distal Radius
Jong Ryoon BAEK ; Yong Cheol YOON ; Seung Hyun BAEK
Journal of the Korean Fracture Society 2019;32(4):204-210
PURPOSE: This study investigated the clinical and radiological outcomes of patients undergoing provisional fixation in conjunction with locking plate fixation. Miniplates were used as the reduction plates for the surgical treatment of severe comminuted metadiaphyseal fractures with an intra-articular fracture of the distal radius. MATERIALS AND METHODS: The radial length, radial inclination, volar tilt, and radial intra-articular step-off were measured preoperatively, postoperatively, and at one year after surgery in 12 patients (eight males, four females, mean age 55.4 years old). The patients underwent volar locking plate fixation with miniplate as a reduction plate for severe comminuted metadiaphyseal fractures with an intra-articular fracture of the distal radius. Clinical evaluations were conducted using the modified Mayo wrist score (MMWS). RESULTS: Bone union was achieved in all cases. The mean MMWS was 81.8 points, including two excellent, three good, and seven fair cases. Radiological improvements were observed in the average radial length (preoperative, 6.4 mm; postoperative, 11.8 mm), average radial inclination (10.2° to 22.4°), average volar tilt (−4.5° to 10.6°), and average radial intra-articular step-off (4.8–0.8 mm) (all, p<0.05). Radiographic measurements obtained immediately after surgery and at the final follow-up revealed insignificant decreases in radial length (0.6 mm), radial inclination (0.4°), and volar tilt (0.9°) (all, p>0.05). CONCLUSION: Miniplate fixation can be an effective treatment option as a reduction plate for the treatment of distal radial fractures, which is challenging to reduce and maintain due to severely comminuted metadiaphysis fractures with the intra-articular fracture.
Female
;
Follow-Up Studies
;
Fractures, Comminuted
;
Humans
;
Intra-Articular Fractures
;
Male
;
Radius
;
Wrist
10.Simulation for Reduction of Transverse Acetabular Fractures in Sawbones Models
Seongeun BYUN ; Cyril MAUFFREY ; Jehyun YOO ; Changwon PARK ; Jihyo HWANG
Journal of the Korean Fracture Society 2019;32(4):196-203
PURPOSE: The transversely oriented fracture lines are very difficult to reduce during operations, even after clear exposure of the fracture site, in acetabular fractures. The purpose of this study is to verify the quality of reduction between the different subtypes (transtectal, juxtatectal, and infratectal) of transverse fractures. This study also determined the proper type of clamps to use and the proper zone for achieving accurate reductions in Sawbones models. MATERIALS AND METHODS: Six fractures in 3 different subtypes of transverse fractures were artificially created. Ten different reduction clamps were applied for reduction of the fractures. Twelve holes around the fracture were drilled for the maintenance of the clamps. The fracture displacements were measured at the extra-articular area and the intra-articular joint portion. The pictures of the intra-articular fracture displacements were taken by a camera and these were uploaded and analyzed by the TraumaCad® computer program (Brainlab). RESULTS: The reduction quality was poor in order of transtectal, juxtatectal and infratectal. The intraarticular opening was more prominent in the transtectal subtype. The safe zone, when giving consideration of the neurovascular bundles, was a quadrilateral surface of the ilium. Drill holes are useful for maintenance of the reduction clamps. Reduction clamps with points (Weber clamp) were the best for maintenance and accurate reduction. Regarding the concerns of placement of clamps, the middle to posterior combination was the best. The upper hole among the posterior holes in the ilium was the most likely to well reduce the intra-articular opening. CONCLUSION: Transtectal was the more complicated subtype in the aspect of reduction quality. The Weber type reduction clamp was the best for reduction by centrally located holes in the quadrilateral surface and posteriorly located iliac holes in transverse acetabular fractures. The upper hole, among the posterior holes in the ilium, was the best for reduction of the fracture displacements in the intraarticular portion of acetabulum.
Acetabulum
;
Ilium
;
Intra-Articular Fractures
;
Joints

Result Analysis
Print
Save
E-mail