1.Clinical efficacy of robot-assisted single-position OLIF with lateral plate combined with posterior unilateral fixation for single-segment lumbar spinal stenosis.
Yuekun FANG ; Zhilin YANG ; Haotian LI ; Weizhou WANG ; Hangchuang BI ; Bing WANG ; Junjie DONG ; Jin YANG ; Zhiqiang GONG ; Lingqiang CHEN
Journal of Central South University(Medical Sciences) 2025;50(1):119-129
OBJECTIVES:
Oblique lateral interbody fusion (OLIF) has become a well-established treatment for lumbar spinal stenosis (LSS) due to its advantages of being minimally invasive, effective, and associated with fewer complications. However, relying solely on lateral fixation provides limited strength and uneven load distribution. Conventional posterior bilateral fixation after OLIF typically requires intraoperative repositioning, increases fluoroscopy frequency, and involves extensive dissection of posterior muscles and soft tissues, resulting in greater trauma, blood loss, and risks of dural tear, nerve root injury, and persistent postoperative low back pain. This study aims to compare the clinical efficacy of robot-assisted single-position OLIF with lateral plating and posterior unilateral fixation, OLIF with lateral fixation alone, and OLIF combined with posterior bilateral fixation for treating single-segment LSS, and to explore how to enhance fixation stability, reduce trauma, and achieve precise minimally invasive outcomes without changing patient positioning.
METHODS:
A retrospective analysis was conducted on the clinical data from patients treated for single-segment LSS between January 2020 and June 2023 at the First Affiliated Hospital of Kunming Medical University. Patients were divided into 3 groups: Robot group (robot-assisted single-position OLIF with lateral plate and posterior unilateral fixation, 33 cases), lateral group (OLIF with lateral fixation alone, 52 cases), and combined group (OLIF with posterior bilateral fixation, 45 cases). Surgical time, intraoperative blood loss, fluoroscopy frequency, hospital stay, pedicle screw placement accuracy, and complication rates were recorded. Pain visual analogue scale (VAS) scores and Oswestry disability index (ODI) scores were assessed preoperatively, postoperatively, and at the final follow-up. Radiological evaluations (X-ray, computed tomography, and magnetic resonance imaging) measured interbody disc height (IDH), intervertebral foraminal height (IFH), and cross-sectional area (CSA) of the dural sac. Differences between pre- and postoperative imaging indices were statistically analyzed, and complication rates, fusion rates, and cage subsidence rates were recorded.
RESULTS:
All patients exhibited good positioning of internal fixation devices and cages, with significant symptom relief and no cases of spinal cord injury or symptom worsening. The follow-up time was (15.2±3.6) months. The operation time of the robot group was (70.62±8.99) min, which was longer than that of the lateral group (45.90±6.09) min and shorter than that of the combined group (110.12±8.44) min. The intraoperative blood loss of the robot group was (44.27±6.87) mL, which was more than that of the lateral group (33.58±9.73) mL and less than that of the combined group (79.19±10.35) mL. The number of intraoperative fluoroscopy times of the robot group was (9.49±2.25), which was comparable to that of the lateral group (7.45±2.02) but less than that of the combined group (12.24±4.25). The hospital stay of the robot group was (9.28±2.10) days, which was longer than that of the lateral group (7.95±1.91) days and shorter than that of the combined group (12.49±5.07) days. The screw placement accuracy of the robot group was 98.48%, which was higher than that of the combined group (90.55%). Postoperative and final follow-up VAS and ODI scores were significantly lower than preoperative scores in all 3 groups (all P<0.05), and there were no significant differences in preoperative VAS and ODI scores among the groups (all P>0.05). Radiologically, IDH, IFH, and CSA at the surgical segment were significantly increased postoperatively and at final follow-up compared to preoperatively and at final follow-up compared to preoperative values (all P<0.05), with no significant differences among the groups postoperatively (all P>0.05). Internal fixation remained stable during the follow-up period, and all cages achieved fusion at final follow-up. The intervertebral fusion rate of the robot-assisted group was 93.40%, which was similar to that of the combined group (95.56%) and higher than that of the lateral approach group (90.34%). The complication rate of the robot-assisted group was 6.1%, which was comparable to that of the combined group (8.9%) and lower than that of the lateral approach group (15.4%) (P<0.05). No cases of fixation loosening or breakage were observed throughout the follow-up period.
CONCLUSIONS
Robot-assisted single-position OLIF with lateral plate combined with posterior unilateral fixation effectively achieves indirect decompression and excellent spinal stability without the need for intraoperative repositioning. It provides high pedicle screw accuracy, reduces intraoperative blood loss, fluoroscopy times, and complication rates, offering a fully minimally invasive new treatment option for single-segment LSS.
Humans
;
Spinal Stenosis/surgery*
;
Robotic Surgical Procedures/methods*
;
Lumbar Vertebrae/surgery*
;
Spinal Fusion/instrumentation*
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Aged
;
Treatment Outcome
;
Bone Plates
;
Minimally Invasive Surgical Procedures/methods*
;
Adult
2.Biomechanical analysis of a novel bridging plate for treating Rockwood III acromioclavicular joint dislocation.
Yancai CHEN ; Gaofeng ZHANG ; Shubo LI ; Nianxiang LUO ; Yi ZHANG
Journal of Southern Medical University 2025;45(5):1103-1112
OBJECTIVES:
To assess the biomechanical performance of a novel bridging plate for treating Rockwood III acromioclavicular joint dislocation.
METHODS:
A novel bridging plate structure was designed based on CT data from a patient with Rockwood type III acromioclavicular joint dislocation, and a finite element model of the bridging plate-acromioclavicular joint interaction was constructed. The stress and deformation characteristics and biomechanical compatibility of the plate under post-reduction, normal loading, and impact loading conditions were analyzed to evaluate its fixation mechanism and clinical advantages.
RESULTS:
The stiffness of the bridging system was 27.78 N/mm, close to that of acromioclavicular joint ligaments (26.05 N/mm) and meeting the requirements for flexible deformation. Under normal loading, the maximum stress in the bridging system was 88.29 MPa to sustain physiological activities; under impact loading, the maximum stress reached 480 MPa, and the cable underwent plastic deformation to dissipate energy and effectively buffer local stress concentrations, thereby reducing the risk of rigid bone fractures. The high-stress regions in the bone primarily occurred at the edges of the C1-C4 screw holes. The maximum bone stress was 0.762 MPa under normal loading and 5.963 MPa under impact loading, accounting for 2.86% and 1.66% of the corresponding bolt stresses, respectively.
CONCLUSIONS
The novel bridging plate is better adapted to biomechanical characteristics of the acromioclavicular joint compared to traditional internal fixation. This fixation system provides sufficient stability while allowing physiological micromotion to facilitate postoperative rehabilitation. Significant flexible deformation can occur at the connection between the fixation ring and the cable, and brittle materials should not be used in this region. The issue of stress concentration at the C1-C4 screw holes requires special attention in its clinical application.
Acromioclavicular Joint/surgery*
;
Humans
;
Bone Plates
;
Biomechanical Phenomena
;
Finite Element Analysis
;
Joint Dislocations/surgery*
;
Fracture Fixation, Internal/methods*
3.Application progress of customized steel plates in osteotomy and orthopedic treatment of knee osteoarthritis.
Jingkun JIA ; Jianxiong MA ; Xinlong MA
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1586-1590
OBJECTIVE:
To review the application progress of customized steel plates in osteotomy and orthopedic treatment for knee osteoarthritis (KOA), and provide reference for orthopedic surgeons and researchers.
METHODS:
Extensive review of the literature on customized steel plates for osteotomies and knee-preserving surgeries for KOA, 2015-2025, with an overview of the principles of customized steel plate design, clinical applications, and future directions, describing their advantages and shortcomings.
RESULTS:
Customized steel plates have demonstrated many advantages in osteotomy and orthopedic treatment of KOA, which not only enhance surgical outcomes and optimize mechanical properties, but also reduce the incidence of postoperative complications. However, high cost, long manufacturing period, and selection of patient indications are still important factors restricting their use.
CONCLUSION
Customized steel plates show promising potential in treating KOA. Not only do they reduce surgical duration and enhance postoperative healing outcomes, but they also effectively lower the incidence of postoperative complications, thereby improving patients' quality of life.
Humans
;
Osteoarthritis, Knee/surgery*
;
Osteotomy/methods*
;
Bone Plates
;
Postoperative Complications/epidemiology*
;
Steel
;
Quality of Life
;
Treatment Outcome
;
Knee Joint/surgery*
4.Research progress on augmentation repair of anterior talofibular ligament under arthroscopy.
Minyuan ZHANG ; Kaiquan LI ; Hongmai YANG ; Yanlin LI
Chinese Journal of Reparative and Reconstructive Surgery 2025;39(12):1600-1605
OBJECTIVE:
To summarize the research progress on augmentation repair of anterior talofibular ligament (ATFL) under arthroscopy.
METHODS:
The domestic and international studies from the past decade on augmentation repair techniques for the ATFL. The advantages and limitations of each approach were summarized and the outcomes of these augmentation repair techniques when applied to ATFL repair were evaluated.
RESULTS:
Mechanical augmentation technique (suture tape or internal brace technique, double anchor enhancement technique) can increase the strength after ATFL repair, but it will increase the economic burden of the patients; bioenhanced repair technology (inferior extensor retinaculum enhancement, anterior tibiofibular ligament's distal fascicle transfer augmentation) can also increase the strength after ATFL repair, but it will damage the anatomical structure in the ankle cavity to a certain extent, and the surgery is difficult, and the operation time will prolong and also increase the incidence of perioperative complications. Regardless of the augmentation repair techniques used, the benefits are higher for patients with high exercise needs, and active postoperative rehabilitation is required to maximize the surgical effect.
CONCLUSION
Although augmentation repair of ATFL offers several advantages, its use-whether augmentation should be employed and, if so, which technique is preferable-requires further study across patient subgroups owing to increased costs, potential disruption of ankle anatomy, and longer operation time.
Humans
;
Arthroscopy/methods*
;
Lateral Ligament, Ankle/injuries*
;
Ankle Joint/surgery*
;
Suture Techniques
;
Ankle Injuries/surgery*
;
Suture Anchors
5.Comparison of short-term clinical efficacy between CO external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures.
Min-Rui FU ; Chang-Long SHI ; Yong-Zhong CHENG ; Ming-Ming MA ; Zheng-Lin NIU ; Hai-Xiang SUN ; Jing-Hua GAO ; Zhong-Kai WU ; Yi-Ming XU
China Journal of Orthopaedics and Traumatology 2025;38(1):10-17
OBJECTIVE:
To evaluate the short-term clinical efficacy of external fixation and internal fixation with steel plate in the treatment of unstable distal radius fractures (AO-23C type), based on the principles of Chinese osteosynthesis (CO).
METHODS:
Forty-eight patients with unstable distal radius fractures between January 2022 and February 2023 were retrospectively analyzed and divided into the CO external fixation group and internal fixation group. CO external fixation group consisted of 25 patients, including 7 males and 18 females, aged from 37 to 56 years old with an average of ( 52.6±11.3) years old. Among them, there were 7 patients of traffic accidents and 18 patients of falls, resulting in a total of 25 patients of closed fractures and no open fractures, the treatment was conducted using closed reduction and CO external fixation. The internal fixation group consisted of 23 patients, comprising 8 males and 15 females, age ranged from 41 to 59 years old, with an average age of(53.3±13.7) years old. Among them, 8 patients resulted from car accidents while the remaining 15 patients were caused by falls. All 23 patients were closed fractures without any open fractures observed. The technique of open reduction and internal fixation with steel plate was employed. The perioperative data, including injury-operation time, operation duration, blood loss, and length of hospital stay, were assessed in both groups. Additionally, the QuickDASH score and visual analogue scale (VAS) were evaluated. Range of motion and grip strength assessment, imaging findings such as palmar inclination angle, ulnar declination angle, radius length, articular surface step, intra-articular space measurements were also examined along with any complications.
RESULTS:
The follow-up duration ranged from 0 to 24 months, with an average duration of (16.0±3.8) months. The CO external fixation exhibited significantly shorter time from injury to operation (2.4±3.3) d vs (7.4±3.7) d, shorter operation duration (56.27±15.23) min vs (74.10±5.26) min, lower blood loss (14.52±6.54) ml vs (32.32±10.03) ml, and reduced hospitalization days (14.04±3.24 )d vs (16.45±3.05) d compared to the internal fixation group (P<0.05). The QuickDASH score at 12 months post-operation was (8.21±1.64) in the CO external fixation group, while no significant difference was observed in the internal fixation group (7.04±3.64), P>0.05. There were no statistically significant differences in VAS between two groups at 6 weeks, as well as 1 and 3 months post-surgery (P>0.05). Additionally, there were no significant disparities observed in terms of range of motion and grip strength between two groups at the 2-year follow-up after the operation (P>0.05). After 12 months of surgery, the CO external fixation group exhibited a significantly smaller palmar inclination angle (17.90±2.18) ° vs (19.87±3.21) °, reduced articular surface step (0.11±0.03) mm vs (0.17±0.02) mm, and shorter radius length (8.16±1.11) mm compared to the internal fixation group (9.59±1.02) mm, P<0.05. The ulnar deviation angle and intra-articular space did not show any significant difference between two groups (P>0.05). The reduced fell within the allowable range between the CO external fixation group (23 out of 25 cases) and the internal fixation group (21 out of 23 cases) was not statistically significant (P=0.29). There was no significant difference in complications between the two groups(P>0.05).
CONCLUSION
Both the CO external fixation and open reduction with plate internal fixation demonstrate clinical efficacy in managing unstable distal radius fractures. The CO external fixation offers advantages in shorter injury-to-operation times, reduced intraoperative blood loss, and decreased surgical durations, while radial shortening is more effectively controlled by internal fixation.
Humans
;
Male
;
Female
;
Middle Aged
;
Radius Fractures/physiopathology*
;
Adult
;
Bone Plates
;
Fracture Fixation, Internal/methods*
;
External Fixators
;
Retrospective Studies
;
Fracture Fixation/methods*
;
Wrist Fractures
6.Clinical efficacy of open reduction and internal fixation with plates versus minimally invasive Kirschner wire fixation for osteoporotic Colles' fractures.
Jun-Wei ZHANG ; Jin-Yong HOU ; Zhao-Hui LI ; Zhen-Yuan MA ; Xiang GAO ; Hong-Zheng BI ; Ling-Ling CHEN ; Hai-Tao WANG ; Wei-Zhi NIE ; Yong-Zhong CHENG ; Xiao-Bing XI
China Journal of Orthopaedics and Traumatology 2025;38(1):18-24
OBJECTIVE:
To compare the short-term clinical efficacy and safety of closed reduction with Kirschner wire fixation versus open reduction with plate fixation for treating osteoporotic Colles' fractures in middle-aged and elderly patients.
METHODS:
Between January 2018 and January 2023, 119 patients with Colles fractures were retrospectively analyzed, including 39 males and 80 females, aged from 48 to 74 years old with an average of(60.58±6.71) years old. The time from injury to operation ranged 1 to 13 days with an average of (5.29±2.52) days. According to the surgical method, they were divided into Kirschner wire fixation group (Kirschner wire group) and plate internal fixation group (plate group). In Kirschner wire group, there were a total of 68 patients, comprising 21 males and 47 females. The average age was (61.15±6.24) years old, ranged from 49 to 74 years old. Among them, 41 cases involved the left side while 27 cases involved the right side. In the plate group, there were a total of 51 patients, including 18 males and 33 females. The average age was (59.78±5.71) years old ranged from 48 to 72 years old. Among them, there were 31 cases on the left side and 20 cases on the right side. The following parameters were recorded before and after the operation:operation time, intraoperative blood loss, hospitalization days, hospitalization expenses, postoperative complications, and radiographic parameters of distal radius (distal radius height, ulnar deviation angle, palmar tilt angle). The clinical efficacy was evaluated at 3 and 12 months after the operation using Gartland-Werley and disabilites of the arm shoulder and hand (DASH) scores.
RESULTS:
The patients in both groups were followed up for a duration from 12 to 19 months with an average of(13.32±2.02) months. The Kirschner wire group exhibited significantly shorter operation time compared to the plate group 27.91(13.00, 42.00) min vs 67.52(29.72, 105.32) min, Z=-8.74, P=0.00. Intraoperative blood loss was also significantly lower in the Kirschner wire group than in the plate group 3.24(1.08, 5.40) ml vs 21.91(17.38, 26.44) ml, Z=-9.31, P=0.00. Furthermore, patients in the Kirschner wire group had a shorter length of hospital stay compared to those in the plate group (8.38±2.63) days vs (11.40±2.78) days, t=-3.12, P=0.00. Additionally, hospitalization cost was significantly lower in the Kirschner wire group than in the plate group 10 111.29(6 738.98, 13 483.60) yuan vs 15 871.11(11 690.40, 20 051.82) yuan, Z=-5.62, P=0.00. The incidence of complications was 2 cases in the Kirschner wire group and 1 case in the plate group, with no statistically significant difference(P>0.05). At 3 months postoprative, the radial height of the Kirschner wire group was found to be significantly smaller than that of the plate group, with measurements of (11.45±1.69) mm and (12.11±1.78) mm respectively (t=-2.06, P=0.04). However, there were no statistically significant differences observed in ulnar deviation angle and palmar tilt angle between the two groups (P>0.05). The DASH score and Gartland-Werley score in the Kirschner group were significantly higher than those in the plate group at 3 months post-operation (19.10±9.89) vs (13.47±3.51), t=4.34, P=0.00;(11.15±3.61) vs (6.41±2.75), t=8.13, P=0.00). However, there was no significant difference between the two groups at 12 months post-operation (P>0.05).
CONCLUSION
Compared to plate internal fixation, closed reduction with Kirschner wire support fixation yields a slightly inferior recovery of radial height;however, there is no significant disparity in the functional score of the affected limb at 12 months post-operation. Nonetheless, this technique offers advantages such as shorter operation time, reduced intraoperative blood loss, decreased hospitalization duration, and lower cost.
Humans
;
Female
;
Male
;
Middle Aged
;
Aged
;
Fracture Fixation, Internal/instrumentation*
;
Bone Wires
;
Bone Plates
;
Retrospective Studies
;
Colles' Fracture/surgery*
;
Minimally Invasive Surgical Procedures/methods*
;
Open Fracture Reduction/methods*
;
Osteoporotic Fractures/surgery*
7.Short-term clinical efficacy of unilateral external fixator combined with percutaneous Kirschner wire fixation in the treatment of type C1 distal radius fractures in elderly patients.
Run-Bin SHEN ; Guo-Liang LI ; Xiao-Ping LIU ; Kang CHEN ; Guang-Pu HAN ; Jian-Yong ZHAO
China Journal of Orthopaedics and Traumatology 2025;38(1):25-30
OBJECTIVE:
To investigate the short-term clinical effect of closed reduction single arm external fixator combined with percutaneous needle fixation in the treatment of C1 distal radius fracture in elderly patients.
METHODS:
Between December 2022 and December 2023, a total of 60 elderly patients diagnosed with type C1 distal radius fractures were treated, comprising 9 males and 51 females. The age ranged from 65 to 84 years old, with an average of (72.69±8.14) years old. Among them, there were 18 cases on the left side and 42 cases on the right side. There were 55 cases of falling injury and 5 cases of traffic accident injury. According to the different surgical methods, the patients were divided into observation group and control group, with 30 cases in each group. The control group underwent manual reduction and unilateral external fixator fixation, consisting of 4 males and 26 females. The mean age was (72.54±8.67) years old. The body mass index (BMI) was (20.61±2.17) kg·m-2. There were 10 cases on the left side and 20 cases on the right side. Among them, there were 27 cases of falling injury and 3 cases of traffic accident injury. The observation group was treated with manual reduction and unilateral external fixator combined with percutaneous Kirschner wire fixation, including 5 males and 25 females. The mean age was (72.76±7.23) years old. BMI (20.82±2.03) kg·m-2. The left side was involved in 8 cases and the right side in 22 cases. There were 28 cases of falling injury and 2 cases of traffic accident injury. The changes in radial height, ulnar declination, palmar inclination angle parameters and patient-rated wrist evaluation (PRWE) were assessed on X-ray films before surgery, 2 days after surgery, and 12 weeks after surgery between the two groups.
RESULTS:
All surgical procedures were successfully completed in both groups without any significant complications. All patients were followed up for a duration from 12 to 20 weeks with an average of(14.50±2.78) weeks. The two groups exhibited significant differences in radial height, palmar inclination angle, and ulnar deviation angle at 2 days and 12 weeks post-operation (P<0.05). However, there was no statistically significant difference observed in radial height, palmar inclination, and ulnar deviation between the two groups at 2 days after the operation (P>0.05). There were significant differences in radial height, palmar inclination angle, and ulnar deviation between the two groups at 12 weeks after operation (P<0.05). At 2 days and 12 weeks after the operation, there were significant differences in PRWE scores of the two groups compared with preoperative scores(P<0.05). At 2 days after the operation, there was no significant difference in PRWE score between the two groups (P>0.05). The PRWE score showed a significant difference between the two groups at 12 weeks post-operation(P<0.05).
CONCLUSION
The combination of closed reduction and unilateral external fixator, along with percutaneous pin fixation provides move stable fixation for type C1 distal radius fractures. Gradual removal of external fixator further facilitatse the recovery of wrist joint function.
Humans
;
Male
;
Female
;
Radius Fractures/surgery*
;
External Fixators
;
Aged
;
Aged, 80 and over
;
Bone Wires
;
Fracture Fixation/instrumentation*
;
Wrist Fractures
8.A preliminary study of risk factors for the stress fracture in treated with clavicle hook plate.
Peng-Fei NIE ; Yuan-Lin XU ; Yong-Fu LI ; Lun ZHANG ; Qian-Qian ZHOU ; Jian-Nyu LUO ; Jian GUO
China Journal of Orthopaedics and Traumatology 2025;38(1):61-65
OBJECTIVE:
To investigate the effects of bone density, plate bending degree and proximal screw type on the stress fracture of clavicle hook.
METHODS:
Three sows weighing between 45 and 50 kg were selected, from which a total of 40 rivs were collected. The 15 ribs of sows were divided into 3 groups according to bone density and bone hardness with 5 rivs in each group. And then the 3 groups were fixed with 6-hole collarbone hook plates and 3 locking screws. Measure the maximum torsion force when the ribs were fractured by force. The same size 15 rids were divided into 3 groups, named forward bending group, 0° group(the angle between the plate surface and the rib surface) and reverse bending group. All fixed with 6-hole collarbone hook plates and locking screws to measure the maximum torsion force of rib stress fracture. Then the same size 10 rids were divided into 2 groups, the normal screw group and the locking screw group with 5 ribs in each group. Both groups were fixed with 6-hole collarbone hook plates and screws. The normal screw group was a normal screw, fixed in proximal end, and two locking screws. The locking screw group was fixed by locking screws. Measure the maximum torsion force of the two groups when the ribs fracture by force.
RESULTS:
In the bone density experiment, the torque force of hard bone group (104.51±6.27) N was greater than the normal bone group (75.04±3.81) N(t=8.979, P<0.05). The force of normal bone group was greater than the osteoporosis group (49.99±2.12) N(t=12.832, P<0.05). In the bending collarbone hook experiment, the order of the torque force generated by each group as follow:the forward bending group (343.59±6.18) N greater than the 0° group (106.01±5.29) N(t=65.279, P<0.05) greater than the reverse bending group (95.82±4.12) N(t=3.398, P<0.05). The force of the normal screw group (98.68±0.70) N was greater than the locking screw group (50.20±0.95) N(t=91.484, P<0.05). The data comparisons of each group were statistically significant.
CONCLUSION
Bone density, plate bending degree and proximal screw type had an impact on stress fracture of clavicle hook plate. Higher bone density, forward bending of the steel plate, and ordinary screws in proximal end can reduce the rates of stress fractures of clavicle hooks.
Animals
;
Bone Plates
;
Clavicle/surgery*
;
Swine
;
Fractures, Stress/etiology*
;
Female
;
Risk Factors
;
Fracture Fixation, Internal/instrumentation*
;
Bone Screws
;
Biomechanical Phenomena
;
Bone Density
9.Meta-analysis of the efficacy of plate fixation and external fixator fixation in the treatment of AO-C type distal radius fractures.
Guang-Yao LI ; Yong-Zhong CHENG ; Huan LIU ; Jun-Jie JIANG ; Yong-Yao LI ; Yang CHEN ; Yu-Xiang YAO
China Journal of Orthopaedics and Traumatology 2025;38(1):66-80
OBJECTIVE:
Meta-analysis of the clinical efficacy of plate and external fixator fixation in the treatment of AO-C type distal radius fractures.
METHODS:
PubMed, Embase, Cochrane Medical Library, Web of Science, CNKI, Wanfang, VIP and SinoMed databases were searched for all literature on randomized controlled clinical trials of AO-C distal radius fractures. The search time limits were from each database. The database will be established until June 30, 2023. The included studies were extracted according to the Cochrane Handbook (Version 6.3, 2022) for information extraction and literature quality evaluation. RevMan 5.4 was used to evaluate the risk of Publication bias, test heterogeneity and Perform Meta-analysis. The outcome indicators were:imaging anatomy indicators (volar inclination angle, ulnar deviation angle, radial height), wrist joint mobility (flexion, extension, rotation, ulnar deviation), complication rate, and comparison of surgical treatments (operative blood loss, operation time, hospitalization time, fracture healing time) and wrist joint function scores and related scales.
RESULTS:
(1) A total of 28 studies were included, with a total of 2 192 patients, including 1 096 cases in the plate internal fixation group and 1 096 cases in the external fixation group.(2) Meta analysis results showed:the surgical treatment situation of the external fixation group:surgical blood loss MD=-37.93, 95%CI(-48.54, -27.31), P<0.000 01;operation time MD=-31.58, 95%CI(-48.96, -14.20), P<0.000 4;hospitalization time MD=-4.58, 95%CI(-5.44, -3.71), P<0.000 01;the fracture healing time MD=-0.88, 95%CI(-1.35, -0.41), P<0.000 2, which were significantly better than that of the plate internal fixation group(P<0.05).(3) The two groups:palmar inclination angle MD=-0.17, 95%CI(-0.95, 0.61), P=0.68;ulnar declination MD=0.22, 95%CI(-0.73, 1.17), P=0.65, radial height MD=-0.24, 95%CI(-1.15, 0.67), P=0.60;flexion and extension MD=-5.63, 95%CI(-11.85, 0.58), P=0.08;rotation MD=-5.80, 95%CI(-12.77, 1.17), P=0.10, radioulnar deviation MD=-2.86, 95%CI(-10.87, 5.15), P=0.48;complication rate RR=0.96, 95%CI(0.63, 1.46), P=0.83;Gartland-Werley clinical wrist score MD=0.13, 95%CI(-0.80, 1.06), P=0.78;excellent and good rate of Gartland-Werley wrist clinical score RR=0.93, 95%CI(0.87, 1.01), P=0.08;excellent and good rate of Cooney wrist score RR=0.99, 95%CI(0.62, 1.59), P=0.98;wrist DASH score MD=-4.67, 95%CI(-14.96, 5.62), P=0.37;the differences were not significant (P>0.05).
CONCLUSION
Compared with internal fixation with plate, external fixation can significantly reduce the amount of surgical bleeding, shorten the operation time, hospitalization time and fracture healing time, and its imaging anatomical indicators, wrist mobility, and complications can be significantly reduced in treating AO-C distal radius fractures. Rates and wrist function scores were equivalent.
Humans
;
External Fixators
;
Bone Plates
;
Radius Fractures/surgery*
;
Fracture Fixation/methods*
;
Fracture Fixation, Internal
;
Wrist Fractures
10.Dorsally displaced distal radial double-column Die-punch fractures by dorsal approach external fixator combined with Kirschner wires.
Fu-de JIAO ; Jing-Wei ZHANG ; Li-Mei ZHU ; Lin AN ; Yun-Qiang ZHUANG ; Jian-Ming CHEN
China Journal of Orthopaedics and Traumatology 2025;38(1):87-91
OBJECTIVE:
Investigating the clinical efficacy of treating dorsally displaced distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires.
METHODS:
Retrospectively analyzed the clinical data of 15 patients with distal radial double-column Die-punch fractures treated with an external fixator combined with Kirschner wire between July 2020 and January 2023. There were 10 males and 5 females;6 cases on the left side and 9 on the right;age ranged from 22 to 76 years old. Recorded the preoperative and the final follow-up Cooney wrist function scores for the patients. The fracture healing time, and occurrence of complications were recorded.
RESULTS:
All 15 patients were followed up ranged from 12 to 16 months post-operation. All fractures achieved bony union, healing time ranging form 8 to 16 weeks. Not a single patient exhibited complications such as surgical site infection, fracture redislocation, or tendon injury. All individuals had their Kirschner wires and external fixation devices removed six weeks post-operatively and commenced rehabilitative therapy for wrist articulation. The Cooney wrist function scores at preoperative and ranged from 5 to 45 scores, at the latest follow-up ranged from 65 to 100 scores. At the final follow-up, the results were assessed as excellent in 10 patients, good in 4 patients, and fair in 1 patient.
CONCLUSION
The clinical efficacy of treating distal radial double-column Die-punch fractures using a dorsal approach external fixator combined with Kirschner wires is satisfactory.
Humans
;
Male
;
Female
;
Middle Aged
;
Adult
;
External Fixators
;
Bone Wires
;
Aged
;
Retrospective Studies
;
Radius Fractures/physiopathology*
;
Young Adult
;
Fracture Fixation/methods*

Result Analysis
Print
Save
E-mail