1.Effect of morphine pump in prepontine cistern via lumbar approach for intractable head and neck cancer pain.
Wenjie ZHANG ; Bohua YIN ; Xinning LI ; Jiaxin LEI ; Yanying XIAO ; Yaping WANG ; Dingquan ZOU
Journal of Central South University(Medical Sciences) 2025;50(6):995-1001
OBJECTIVES:
Managing patients with refractory head and neck cancer pain is one of the more challenging issues in clinical practice, and traditional intrathecal drug delivery also fails to provide adequate analgesia. There are currently no comprehensive and effective treatment methods. This study aims to observe the efficacy and safety of treating intractable head and neck cancer pain with morphine pump via lumbar approach to the prepontine cistern.
METHODS:
A total of 18 patients with intractable head and neck cancer pain treated with prepontine cistern morphine pumps were selected from the Department of Pain Management, Second Xiangya Hospital, Central South University between September 2019 and July 2023. Statistical analysis was performed on patients' preoperative and postoperative (1 week, 1 month, and 2 months after surgery), Numerical Rating Scale (NRS) scores, Self-Rating Depression Scale (SDS) scores, daily oral morphine consumption, the number of daily breakthrough pain episodes, and postoperative daily intrathecal morphine dosage.
RESULTS:
The NRS scores, SDS scores, daily oral morphine consumption, and the number of daily breakthrough pain episodes of patients at each time point after surgery were significantly lower than before surgery (all P<0.05). With the gradual increase in the dosage of intrathecal morphine, the daily oral morphine consumption of patients at each postoperative time point was significantly reduced compared to preoperative levels (all P<0.05). The complications related to the operation were mild, including nausea in 5 cases (31.3%), headache in 2 cases (12.5%); hypotension, urine retention, hypersomnia and constipation in 1 case (6.3% each), and no serious adverse events occurred. All improved and were discharged after symptomatic treatment.
CONCLUSIONS
The implantation of prepontine cistern morphine pump effectively controls intractable head and neck cancer pain, demonstrating characteristics of minimal invasiveness, mild side effects, and low medication dosage under the premise of standardized procedures.
Humans
;
Morphine/administration & dosage*
;
Male
;
Female
;
Middle Aged
;
Head and Neck Neoplasms/surgery*
;
Analgesics, Opioid/administration & dosage*
;
Cancer Pain/drug therapy*
;
Pain, Intractable/etiology*
;
Aged
;
Adult
;
Infusion Pumps, Implantable
;
Pain Management/methods*
2.Research progress on automated insulin delivery system in the field of diabetes management.
Zhichao YU ; Yufan SUN ; Zhijian HUANG ; Zhanhong LI ; Jianjun LONG ; Zhigang ZHU
Journal of Biomedical Engineering 2024;41(6):1279-1285
Diabetes and its complications pose a serious threat to human life and health. It has become a public health problem of wide concern worldwide. Currently, diabetes is mainly treated with insulin injection in clinic. However, manual insulin injection still has many shortcomings. In recent years, with the deepening of research, it has been found that an automated insulin delivery system (AID), which combines a continuous glucose monitoring device with an insulin pump, can significantly improve the effectiveness of diabetes treatment and reduce the incidence of complications in patients. This paper firstly introduces the composition of the AID system and its working principle, and then details the development history and current status of the related technologies from the aspects of continuous glucose monitoring technology, insulin pumps and the development of closed-loop control algorithms, etc. Finally, this paper looks forward to the application prospect and future development of AID system in the field of diabetes treatment, providing theoretical reference for further research.
Humans
;
Insulin Infusion Systems
;
Insulin/administration & dosage*
;
Blood Glucose Self-Monitoring/instrumentation*
;
Diabetes Mellitus/drug therapy*
;
Algorithms
;
Hypoglycemic Agents/administration & dosage*
;
Blood Glucose/analysis*
;
Pancreas, Artificial
;
Automation
3.Optimization of Quality Control Efficiency of Infusion Pump.
Chinese Journal of Medical Instrumentation 2022;46(2):233-236
OBJECTIVE:
Analyze and conclude the new quality control process, so as to improve the quality control efficiency.
METHODS:
Statistical analysis was conducted on the flow rate quality control data of infusion pump in 2020, with a total of 330 times of quality control data.
RESULTS:
The pump with qualified flow rate entered and maintained the qualified state from the third minute, while the pump with unqualified flow rate entered and maintained the unqualified state from the second minute.
CONCLUSIONS
Take the third minute to enter the qualified range and continue for 2 minutes to judge that the flow rate quality control is qualified. The accuracy of this new rule is as high as 100%, and the time of flow rate quality control can be reduced from 60 minutes to 10 minutes, which greatly improves the work efficiency.
Infusion Pumps
;
Quality Control
4.Some Problems and Risk Analysis of Infusion Pump Instructions.
Chinese Journal of Medical Instrumentation 2022;46(3):323-325
OBJECTIVE:
10 instructions of infusion pumps were contrasted and analyzed in order to explore the problems of instructions, furthermore improve the product safety.
METHODS:
Analyzed the scopes of application, requirements of infusion apparatus, maintenance methods and cycles, battery maintenance, and service life, etc.
RESULTS:
There were 5 products in 10 which did not indicate contraindications. One product only provided the thickness range of the tube wall of the infusion apparatus instead of specific brands. The cleaning cycles of 9 products varied from 2 to 12 months. One product did not clarify the service life.
CONCLUSIONS
It is recommended that manufactures should improve the product instructions to ensure the safety of infusion pumps.
Electric Power Supplies
;
Infusion Pumps
;
Risk Assessment
5.Clinical study of hydraulic perfusion pump and traditional water flushing for percutaneous endoscopic lumbar discectomy.
China Journal of Orthopaedics and Traumatology 2021;34(1):63-67
OBJECTIVE:
To compare the clinical outcomes of hydraulic perfusion pump and traditional water fhushing in percutaneous endoscopic lumbar discectomy.
METHODS:
From January 2016 to December 2018, 72 patients with lumbar disc herniation failed to conservative treatment were enrolled in this study. The patients were divided into hydraulic perfusion pump group and traditional water flushing group, 36 cases in each group. There were no significant differences in gender, age, prominent segment, clinical classification, preoperative visual analogue scale (VAS) and Japanese Orthopaedic Association(JOA) score between two groups (
RESULTS:
All the patients were followed up for 12 to 24 (15.7±5.1) months. Compared with the traditional water flushing group, the operation time of the hydraulic perfusion pump group was shorter [(65.5±21.3) min vs (74.8±19.9) min,
CONCLUSION
Both hydraulic perfusion pump and traditional water flushing assisted percutaneous endoscopic lumbar disc herniation can achieve satisfactory clinical results, but the former has shorter operation time, clearer intraoperative vision, less bleeding, and fewer intraoperative and postoperative complications.
Diskectomy
;
Diskectomy, Percutaneous
;
Endoscopy
;
Humans
;
Infusion Pumps
;
Intervertebral Disc Displacement/surgery*
;
Lumbar Vertebrae/surgery*
;
Retrospective Studies
;
Treatment Outcome
;
Water
6.Comparison of Operator Workloads Associated with the Single-unit Anyfusion® Pump and the Changeover from a Syringe Pump to an Infusion Pump
Jeong Jin MIN ; Duk Kyung KIM ; Kwan Young HONG ; Ji Won CHOI ; Ka Young CHOI
Journal of Korean Medical Science 2019;34(49):314-
infusion pump may transiently interrupt drug administration and result in medication errors. A newly developed infusion device (Anyfusion®) that combines the functions of an infusion pump and a syringe pump in a single unit was recently commercialized. This study compared the operator workloads associated with the Anyfusion® pump and with the conventional method using two infusion devices (a syringe pump and an infusion pump).METHODS: This was a prospective, randomized, crossover-designed simulation study using an imitation arm with an intravascular line. We compared the two methods in terms of total execution time, total number of button clicks, and subjective difficulty using a numerical rating scale with a score from 0 (extremely easy) to 10 (extremely difficult).RESULTS: Twenty-two nurses successfully performed both interventions according to the allocated sequence. Total execution times did not differ between the two methods (129.5 ± 23.2 seconds for the conventional method vs. 121.2 ± 24.3 seconds for the Anyfusion® method; P = 0.244), although the total number of clicks was significantly fewer using the Anyfusion® than the conventional method (median [interquartile range]: 10.0 [9.0–12.0] vs. 21.0 [20.0–25.0], respectively; P < 0.001). Participants rated the Anyfusion® method as easier than the conventional method (1.7 ± 1.2 vs. 3.6 ± 1.6; P < 0.001, respectively).CONCLUSION: The introduction of Anyfusion® lessened the workload of practitioners required by the changeover process, which might reduce the risk of medication errors and subsequent patient harm.TRIAL REGISTRATION: Clinical Research Information Service Identifier: KCT0004172]]>
Arm
;
Information Services
;
Infusion Pumps
;
Medication Errors
;
Methods
;
Patient Harm
;
Prospective Studies
;
Syringes
7.Effectiveness of continuous hypertonic saline infusion with an automated infusion pump for decompressive neuroplasty: a randomized clinical trial
Ho Jin LEE ; Jaewoo LEE ; Yeon Wook PARK ; Ho Young GIL ; Eunjoo CHOI ; Francis Sahngun NAHM ; Pyung Bok LEE
The Korean Journal of Pain 2019;32(3):196-205
BACKGROUND: Hypertonic saline (HS) injections for decompressive neuroplasty (DN) can cause pain. We assessed whether a continuous infusion of HS through an infusion pump would reduce injection-related pain compared with repeated bolus administrations. METHODS: Fifty patients scheduled for DN were randomized to either the bolus injection or the continuous infusion group. After appropriately placing the epidural catheter, 4 mL of 5% NaCl was injected as four boluses of 1 mL each at 15-minute intervals or infused over 1 hour using an infusion pump. The severity of pain induced by HS injection, as measured by the 11-point numerical rating scale (NRS), was the primary outcome. The severity of low back or lower extremity pain, as measured by the 11-point NRS and Oswestry Disability Index (ODI), 3 months following the procedure, was the secondary outcome. RESULTS: Data from 21 patients in the bolus group and 23 in the continuous infusion group were analyzed. No statistically significant difference in injection-related pain was identified between the two groups during the initial HS administration (P = 0.846). However, there was a statistically significant reduction in injection-related pain in the continuous infusion group compared to the bolus injection group from the second assessment onwards (P = 0.001, < 0.001, and < 0.001, respectively). No significant between-group differences in the NRS and ODI scores 3 months post-procedure were noted (P = 0.614 and 0.949, respectively). CONCLUSIONS: Our study suggests that administering HS through a continuous infusion is a useful modality for reducing HS injection-related pain during DN.
Catheters
;
Chronic Pain
;
Humans
;
Infusion Pumps
;
Injections, Epidural
;
Low Back Pain
;
Lower Extremity
;
Radiculopathy
;
Saline Solution, Hypertonic
;
Spinal Stenosis
8.Continuous Glucose Monitoring Sensors for Diabetes Management: A Review of Technologies and Applications
Giacomo CAPPON ; Martina VETTORETTI ; Giovanni SPARACINO ; Andrea FACCHINETTI
Diabetes & Metabolism Journal 2019;43(4):383-397
By providing blood glucose (BG) concentration measurements in an almost continuous-time fashion for several consecutive days, wearable minimally-invasive continuous glucose monitoring (CGM) sensors are revolutionizing diabetes management, and are becoming an increasingly adopted technology especially for diabetic individuals requiring insulin administrations. Indeed, by providing glucose real-time insights of BG dynamics and trend, and being equipped with visual and acoustic alarms for hypo- and hyperglycemia, CGM devices have been proved to improve safety and effectiveness of diabetes therapy, reduce hypoglycemia incidence and duration, and decrease glycemic variability. Furthermore, the real-time availability of BG values has been stimulating the realization of new tools to provide patients with decision support to improve insulin dosage tuning and infusion. The aim of this paper is to offer an overview of current literature and future possible developments regarding CGM technologies and applications. In particular, first, we outline the technological evolution of CGM devices through the last 20 years. Then, we discuss about the current use of CGM sensors from patients affected by diabetes, and, we report some works proving the beneficial impact provided by the adoption of CGM. Finally, we review some recent advanced applications for diabetes treatment based on CGM sensors.
Acoustics
;
Blood Glucose
;
Blood Glucose Self-Monitoring
;
Diabetes Mellitus
;
Glucose
;
Humans
;
Hyperglycemia
;
Hypoglycemia
;
Incidence
;
Insulin
;
Insulin Infusion Systems
9.Comparison and Discussion of National/Military Standards Related to Flow Measurement of Medical Injection Pump.
Nan ZHANG ; Juan ZHOU ; Jinlai YU ; Ziyu HUA ; Yongxue LI ; Jiangang WU
Chinese Journal of Medical Instrumentation 2018;42(3):219-221
Medical injection pump is a commonly used clinical equipment with high risk. Accurate detection of flow is an important aspect to ensure its reliable operation. In this paper, we carefully studied and analyzed the flow detection methods of three standards being used in medical injection pump detection in our country. The three standards were compared from the aspects of standard device, flow test point selection, length of test time and accuracy judgment. The advantages and disadvantages of these standards were analyzed and suggestions for improvement were put forward.
Equipment and Supplies
;
standards
;
Infusion Pumps
;
standards
;
Injections
;
Military Personnel
;
Reference Standards
10.Evaluation of Clinical Alarms and Alarm Management in Intensive Care Units
Journal of Korean Biological Nursing Science 2018;20(4):228-235
PURPOSE: This study aimed to investigate the clinical alarm occurrence and management of nurses toward clinical alarms in the intensive care unit (ICU). METHODS: This observational study was conducted with 40 patients and nurses cases in two ICUs of a university hospital. This study divided 24 hours into the unit of an hour and conducted two times of direct observation per unit hour for 48 hours targeting the medical devices applied to 40 patients. Data were analyzed using IBM SPSS Statistics 23. RESULTS: On average, 3.8 units of medical devices were applied for each patient and the ranges of alarm settings were wide. During 48 hours, 184 cases of clinical alarm were occurred by four types of medical devices including physiological monitors, mechanical ventilators, infusion pumps, and continuous renal replacement therapy. Among them, false alarm was 110 cases (59.8%). As for the alarm management by ICU nurses, two-minute alarm mute took up most at 38.0% (70 cases), and no response was second most at 32.6% (60 cases). When valid alarm sounded, nurses showed no response at 43.2%. CONCLUSION: The findings suggest that a standard protocol for alarm management should be developed for Korean ICU settings. Based on the protocol, continuous training and education should be provided to nurses for appropriate alarm management.
Clinical Alarms
;
Critical Care
;
Education
;
Humans
;
Infusion Pumps
;
Intensive Care Units
;
Observational Study
;
Renal Replacement Therapy
;
Ventilators, Mechanical

Result Analysis