1.Effect of Induced Hypertension Therapy According to the Mechanism of Single Subcortical Infarction
Seung Taek OH ; Jun Young CHANG ; Dong-Wha KANG ; Sun U. KWON ; Sang Hee HA ; Bum Joon KIM
Journal of Clinical Neurology 2026;22(2):153-159
Background:
and Purpose Induced hypertension therapy (IHT) is effective for treating early neurological deterioration (END) in patients with single subcortical infarction (SSI). However, the underlying pathophysiology of SSI is diverse and may affect the efficacy of IHT.
Methods:
We reviewed patients with SSI who experienced END and received IHT were enrolled. END was defined as ≥2-point increase in the National Institutes of Health Stroke Scale (NIHSS) score, ≥1 motor point increase. IHT was performed by using phenylephrine infusion to raise systolic blood pressure by 10%–20% over baseline. SSI was classified into three subtypes: distal (dSSI), proximal (pSSI), and SSI with parental artery disease (SSIPAD; with stenosis at parental artery disease <50%). Responders were defined as patients who showed neurological improvement (decrease of ≥2 points in NIHSS, ≥1 motor point decrease) within one day after IHT initiation. Multivariable analysis identified factors associated with responders.
Results:
Characteristics were compared between responders and non-responders, and factors associated with response to IHT were investigated. Among 96 patients (mean age, 64.7± 12.9 years; 61.5% male), 49 (51.0%) patients were categorized as responders. Multivariable analysis showed that pSSI (adjusted odds ratio [aOR]=18.10, 95% confidence interval [CI] 5.04–80.60, p<0.001) and SSIPAD (aOR=4.56, 95% CI 1.31–19.00, p=0.024) were associated with a positive response to IHT compared to dSSI. Additionally, less white matter changes (Fazekas scale 0–1) were associated with a better response to IHT (aOR=0.15, 95% CI 0.03–0.67,p=0.019).
Conclusions
Response to IHT varied according to SSI subtypes and the severity of small vessel changes.
3.Response to the letter to the editor: Inconsistencies in obesity criteria: implications for systematic reviews on endoscopic spine surgery
Wongthawat LIAWRUNGRUEANG ; Watcharaporn CHOLAMJIAK ; Peem SARASOMBATH ; Yudha Mathan SAKTI ; Pang Hung WU ; Meng-Huang WU ; Yu-Jen LU ; Lo Cho YAU ; Zenya ITO ; Sung Tan CHO ; Dong-Gune CHANG ; Kang Taek LIM
Asian Spine Journal 2026;20(1):211-213
4.Molecular determinants of outcome to gemcitabine, cisplatin, and nab-paclitaxel in patients with advanced biliary tract cancer
Daeseong KIM ; Nam Suk SIM ; Seonjeong WOO ; Min Hwan KIM ; Choong-kun LEE ; Seung Soo HONG ; Sung Hyun KIM ; Ho Kyoung HWANG ; Chang Moo KANG ; Woo Jung LEE ; Jung Hyun JO ; Taek CHUNG ; Sohyun HWANG ; Beodeul KANG ; Jung Sun KIM ; Chang-Il KWON ; Sangwoo KIM ; Hong Jae CHON ; Chang Gon KIM ; Young Nyun PARK ; Hye Jin CHOI
Clinical and Molecular Hepatology 2026;32(2):721-736
Background/Aims:
Biliary tract cancer (BTC) is a rare malignancy with poor prognosis. We investigated genomic determinants of clinical benefit from gemcitabine, cisplatin, and nab-paclitaxel (GAP) versus gemcitabine and cisplatin (GC) in advanced BTC.
Methods:
Clinical and genomic data using TruSight Oncology 500 were analyzed from patients treated with GAP (N=198) or GC (N=89) as first-line therapy.
Results:
With a median follow-up of 33.0 months, GAP modestly improved progression-free survival (PFS) (hazard ratio [HR] 0.764; 95% confidence interval [CI] 0.591–0.989) without significant overall survival (OS) difference compared to GC. Genomic profiling revealed frequent alterations in TP53 (35.2%), KRAS (16.4%), SMAD4 (10.5%), and TNFRSF14 (10.5%), involving RTK/RAS (44.3%), TP53 (41.8%), and PI3K (20.2%) pathways. Single-gene mutations did not predict treatment benefit. However, pathway-level analysis identified PI3K pathway activation as significantly associated with inferior PFS (HR 2.148; 95% CI 1.478–3.124) and OS (HR 2.096; 95% CI 1.413–3.109) in patients receiving GAP, an effect not observed with GC. Importantly, GAP conferred clinical benefit only in patients without PI3K pathway activation, while no survival advantage was seen in those with such alterations (Pinteraction=0.023 for PFS, Pinteraction=0.003 for OS). Similar results were obtained in the independent validation cohort treated with GAP (N=103) or GC (N=64) for BTC.
Conclusions
Genomic profiling using next-generation sequencing identified PI3K pathway activation as key molecular determinant that differentiates patient outcomes between GAP and GC treatments in advanced BTC.
5.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
6.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.
7.Endoscopic spine surgery for obesity-related surgical challenges: a systematic review and meta-analysis of current evidence
Wongthawat LIAWRUNGRUEANG ; Watcharaporn CHOLAMJIAK ; Peem SARASOMBATH ; Yudha Mathan SAKTI ; Pang Hung WU ; Meng-Huang WU ; Yu-Jen LU ; Lo Cho YAU ; Zenya ITO ; Sung Tan CHO ; Dong-Gune CHANG ; Kang Taek LIM
Asian Spine Journal 2025;19(2):292-310
Obesity presents significant challenges in spinal surgery, including higher rates of perioperative complications, prolonged operative times, and delayed recovery. Traditional open spine surgery often exacerbates these risks, particularly in patients with obesity, because of extensive tissue dissection and larger incisions. Endoscopic spine surgery (ESS) has emerged as a promising minimally invasive alternative, offering advantages such as reduced tissue trauma, minimal blood loss, lower infection rates, and faster recovery. This systematic review and meta-analysis aimed to evaluate the safety, efficacy, and outcomes of ESS techniques, including fully endoscopic and biportal endoscopic lumbar discectomy and decompression, in patients with obesity and lumbar spine pathologies. A comprehensive literature search of the PubMed/Medline, Embase, and Scopus databases yielded 2,975 studies published between 2000 and 2024, of which 10 met the inclusion criteria. The meta-analysis revealed significant improvements in pain relief (Visual Analog Scale) and functional outcomes (Oswestry Disability Index), with comparable results between patients with and without obesity. Patients who are obese experienced longer operative times and have a slightly higher risk of symptom recurrence; however, ESS demonstrated lower rates of wound infections, shorter hospital stays, and faster recovery than traditional surgery. These findings position ESS as a viable and effective option for managing lumbar spine conditions in patients with obesity, addressing obesity-related surgical challenges while maintaining favorable clinical outcomes. However, limitations such as study heterogeneity and the lack of randomized controlled trials highlight the need for further high-quality research to refine ESS techniques and optimize patient care in this high-risk population.
8.Endoscopic spine surgery for obesity-related surgical challenges: a systematic review and meta-analysis of current evidence
Wongthawat LIAWRUNGRUEANG ; Watcharaporn CHOLAMJIAK ; Peem SARASOMBATH ; Yudha Mathan SAKTI ; Pang Hung WU ; Meng-Huang WU ; Yu-Jen LU ; Lo Cho YAU ; Zenya ITO ; Sung Tan CHO ; Dong-Gune CHANG ; Kang Taek LIM
Asian Spine Journal 2025;19(2):292-310
Obesity presents significant challenges in spinal surgery, including higher rates of perioperative complications, prolonged operative times, and delayed recovery. Traditional open spine surgery often exacerbates these risks, particularly in patients with obesity, because of extensive tissue dissection and larger incisions. Endoscopic spine surgery (ESS) has emerged as a promising minimally invasive alternative, offering advantages such as reduced tissue trauma, minimal blood loss, lower infection rates, and faster recovery. This systematic review and meta-analysis aimed to evaluate the safety, efficacy, and outcomes of ESS techniques, including fully endoscopic and biportal endoscopic lumbar discectomy and decompression, in patients with obesity and lumbar spine pathologies. A comprehensive literature search of the PubMed/Medline, Embase, and Scopus databases yielded 2,975 studies published between 2000 and 2024, of which 10 met the inclusion criteria. The meta-analysis revealed significant improvements in pain relief (Visual Analog Scale) and functional outcomes (Oswestry Disability Index), with comparable results between patients with and without obesity. Patients who are obese experienced longer operative times and have a slightly higher risk of symptom recurrence; however, ESS demonstrated lower rates of wound infections, shorter hospital stays, and faster recovery than traditional surgery. These findings position ESS as a viable and effective option for managing lumbar spine conditions in patients with obesity, addressing obesity-related surgical challenges while maintaining favorable clinical outcomes. However, limitations such as study heterogeneity and the lack of randomized controlled trials highlight the need for further high-quality research to refine ESS techniques and optimize patient care in this high-risk population.
9.Additional Screw Added to the Femoral Neck System Could Enhance the Stability of Pauwel Type III Femoral Neck Fractures:a Finite Element Analysis
Yonghan CHA ; Sunghoon PARK ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON ; Kyeong Jin HAN
Clinics in Orthopedic Surgery 2025;17(2):204-215
Background:
This study explores effective fixation methods for Pauwel type III femoral neck fractures by evaluating the biomechanical benefits of adding a screw to the Femoral Neck System (FNS).
Methods:
Computed tomography (CT) scans of an 82-year-old female patient with an intertrochanteric fracture were used to establish a finite element femur model with heterogeneous material properties. Finite element models of Pauwel type III fractures were created with and without an additional screw. The central and inferior trajectories of the FNS bolt were examined separately and combined with an additional screw for virtual fixation. Walking and stair-climbing loads were applied.
Results:
With the addition of a screw, both peak maximum and minimum principal strains consistently stayed comparable or decreased in models with both central and inferior bolt trajectories, while the volume of elements with principal strain exceeding 1% decreased by more than half. The peak von Mises stress observed in the implants ranged from 215.7 to 359.3 MPa, remaining below the titanium alloy's yield strength of 800 MPa. For normal walking, the addition of a screw to the central bolt trajectory model decreased the fracture gap by 50.6% and reduced sliding distance by 8.6%. For the inferior bolt trajectory, the gap was reduced by 57.9% and sliding distance by 25.0%.Under stair-climbing conditions, these improvements were also evident; the central trajectory model saw a halved fracture gap and a 7.9% decrease in sliding distance, while the inferior trajectory model experienced a 55.7% gap reduction and a 27.2% decrease in sliding distance. The additional screw increased the area ratio of the fracture site experiencing interfragmentary compression 34%–39%, while the additional screw alleviated peak interfragmentary compression by 12%–18% under both normal walking and stair-climbing conditions.
Conclusions
The addition of a screw reduced the fracture gap, sliding distance, and peak interfragmentary compression, while increasing the area ratio of interfragmentary compression under both walking and stair-climbing loads, regardless of the FNS bolt trajectory, suggesting a better mechanical environment for fracture healing.
10.Powered Tool for the Removal of a Well-Fixed Acetabular Cup: A Comparative Experimental Study
Jun Young CHUNG ; Yonghan CHA ; Chang-Ho JUNG ; Jin-Woo KIM ; Jun-Il YOO ; Jung-Taek KIM ; Yongho JEON
Clinics in Orthopedic Surgery 2025;17(3):372-380
Background:
The removal of a well-fixed acetabular cup is a challenging, labor-intensive, and time-consuming step during revision hip arthroplasty. Although the advent of the manual osteotome, Explant, has simplified the procedure, it is still a stressful process as it dissipates the surgeon’s strength and time and risks an iatrogenic pelvic fracture. Recently, EZX, a powered tool for extraction of well-fixed acetabular cups with semicircular blade was invented. This study aimed to compare Explant and EZX in an experimental condition for their efficacy and safety.
Methods:
Cementless acetabular cups were press-fitted to 20 hemipelvic polyurethane models using foam adhesives. Ten cups were removed with each tool for comparison of the elapsed time, loads on the entire hemipelvis, periacetabular strain and temperature, volume of periacetabular bone removed, and diameter of the remaining acetabular rim. Strains and loads were quantitatively assessed using strain gauges and load cells for precise and reliable measurements.
Results:
The mean duration required to remove a well-fixed cup with EZX was 38.5 seconds (range, 25–55), whereas that with Explant was 543.7 seconds (range, 214–1,051) (p < 0.001). The load on the entire hemipelvis with EZX (mean, 9.1 kgf; range, 6.4–11.3) was 33% lower than that with Explant (mean, 13.6 kgf; range, 9.2–17.1) (p < 0.001). The periacetabular peak strains at the 3 positions with EZX were significantly lower than those with Explant (p < 0.001). The temperature during the removal did not differ significantly between the 2 tools. Although the mean volume of bone loss with Explant was 2.4 mL more than that with EZX (p < 0.001), the mean diameters of the remaining acetabular rim were not significantly different, measuring 54.1 mm with both tools.
Conclusions
The present experiment revealed that a well-fixed cup could be removed using a powered tool with less strength and time and less load on the entire pelvis. Although the powered tool removed a larger volume of bone, the diameters of the remaining acetabular rims were equivalent. This tool may help surgeons remove well-fixed cups in a short time and reduce the deforming load on the bone around the cup without increasing the size of the subsequent reconstruction cup.