1.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
2.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
3.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
4.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
5.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
6.Current trends in intraoperative neurophysiological monitoring among Asia–Pacific countries: an Asia–Pacific Spine Society survey
Hideki SHIGEMATSU ; Akimasa YASUDA ; Ronald TANGENTE ; Chris Yin Wei CHAN ; Ajoy Prasad SHETTY ; Jason Pui Yin CHEUNG ; Yong HAI ; Daisuke SAKAI ; Kyu-Jung CHO ; Chih-Wei CHEN ; Gabriel LIU ; I Gusti Lanang Ngurah Agung Artha WIGUNA ; Brian HSU ; Mun Keong KWAN
Asian Spine Journal 2024;18(6):813-821
Methods:
Spine surgeons of the Asia–Pacific Spine Society were asked to respond to a web-based survey on IONM. The questionnaire covered various aspects of IONM, including its common modality, Tc-MEP details, necessities for consistent use, and recommended modalities in major spine surgeries and representative surgical procedures.
Results:
Responses were received from 193 of 626 spine surgeons. Among these respondents, 177 used IONM routinely. Among these 177 respondents, 17 mainly used SEP, whereas the majority favored Tc-MEPs. Although a >50% decrease is the commonly used alarm point in Tc-MEP, half of the Tc-MEP users had no protocols planned for such scenarios. Moreover, half of the Tc-MEP users experienced complications, with bite injuries being the most common. Most respondents strongly recommended IONM in deformity surgery for pediatric and adult populations and tumor resection surgery for intramedullary spinal cord tumors. Conversely, IONM was the least recommended in lumbar spinal canal stenosis surgery.
Conclusions
Spine surgeons in Asia–Pacific countries favored IONM use, indicating widespread routine utilization. Tc-MEP was the predominant modality for IONM, followed by SEPs.
7.Subjective Visual Floaters after Intravitreal Injection and Effect of the Inverse Tapping Technique
Junho MUN ; Yong-Kyu KIM ; Sung Pyo PARK ; Kyoung Lae KIM
Journal of the Korean Ophthalmological Society 2024;65(2):125-131
Purpose:
To analyze the incidence of vitreous floaters after intravitreal antivascular endothelial growth factor injection and the effectiveness of the inverse tapping technique, which involves tapping the syringe with the needle downwards to prevent the entry of air bubbles during injection.
Methods:
The study enrolled patients undergoing their first intravitreal injection for exudative age-related macular degeneration or diabetic macular edema. The patients were divided into two groups: those who received an injection after inverse tapping (IT group) and controls who received the injection without tapping. Patients who consented to the study were randomly assigned to the IT group and the control group through block randomization. One week after injection, a questionnaire was used to assess the presence of vitreous floaters; those who reported them were examined via optical coherence tomography and wide fundus photography.
Results:
Of the 39 patients in the IT group, two (5.1%) reported floaters 1 week after injection. By contrast, eight (20.5%) of the 39 controls reported them, with a significant difference (p = 0.042). Patients with floaters were significantly younger. Posterior vitreous detachment, as evaluated by pre-injection optical coherence tomography, was observed in 10.0% of those with floaters and 76.5% of those without them.
Conclusions
The occurrence of vitreous floaters after intravitreal injection is related to age and the presence of posterior vitreous detachment. The use of the inverse tapping technique may help reduce these after intravitreal injection.
8.Impact of emergency room occupancy on the timing of antibiotic administration in patients with septic shock who visited the emergency room
Taek Kyu NAM ; Ji Ho RYU ; Mun ki MIN ; Daesup LEE ; Mose CHUN ; Seung Woo SON ; Yang Wook TAE ; Minjee LEE
Journal of the Korean Society of Emergency Medicine 2024;35(3):212-222
Objective:
The emergency department (ED) serves as the initial point of contact for many sepsis patients, but crowding can affect the timely delivery of essential interventions, such as antibiotics. This paper explores the relationship between antibiotics administration and ED crowding in the context of sepsis management.
Methods:
This single-center study at a tertiary care hospital included adult patients aged 18 and above who visited the emergency department from January 2018 to December 2022. Patients showing signs of septic shock upon arrival were selected as the study population. This study examined factors such as emergency department occupancy, antibiotic administration time, and their correlation with timely antibiotic treatment.
Results:
This study of 839 adult patients with septic shock found a weak correlation (P=0.107) between the time to antibiotic administration and department occupancy. Delayed antibiotic administration was observed when the occupancy exceeded 100%. On the other hand, there was no significant correlation between antibiotic administration within one hour and department occupancy.
Conclusion
Various factors, such as ED bed occupancy, medical staffing, resource allocation, and patient acuity, must be considered when comprehensively evaluating the impact of ED overcrowding on treating septic shock and other conditions.
9.Current trends in intraoperative neurophysiological monitoring among Asia–Pacific countries: an Asia–Pacific Spine Society survey
Hideki SHIGEMATSU ; Akimasa YASUDA ; Ronald TANGENTE ; Chris Yin Wei CHAN ; Ajoy Prasad SHETTY ; Jason Pui Yin CHEUNG ; Yong HAI ; Daisuke SAKAI ; Kyu-Jung CHO ; Chih-Wei CHEN ; Gabriel LIU ; I Gusti Lanang Ngurah Agung Artha WIGUNA ; Brian HSU ; Mun Keong KWAN
Asian Spine Journal 2024;18(6):813-821
Methods:
Spine surgeons of the Asia–Pacific Spine Society were asked to respond to a web-based survey on IONM. The questionnaire covered various aspects of IONM, including its common modality, Tc-MEP details, necessities for consistent use, and recommended modalities in major spine surgeries and representative surgical procedures.
Results:
Responses were received from 193 of 626 spine surgeons. Among these respondents, 177 used IONM routinely. Among these 177 respondents, 17 mainly used SEP, whereas the majority favored Tc-MEPs. Although a >50% decrease is the commonly used alarm point in Tc-MEP, half of the Tc-MEP users had no protocols planned for such scenarios. Moreover, half of the Tc-MEP users experienced complications, with bite injuries being the most common. Most respondents strongly recommended IONM in deformity surgery for pediatric and adult populations and tumor resection surgery for intramedullary spinal cord tumors. Conversely, IONM was the least recommended in lumbar spinal canal stenosis surgery.
Conclusions
Spine surgeons in Asia–Pacific countries favored IONM use, indicating widespread routine utilization. Tc-MEP was the predominant modality for IONM, followed by SEPs.
10.Association between Age-Related Macular Degeneration and Arthritis: Data from the Korean National Health and Nutrition Examination Survey for 2017 and 2018
Jun Sung NAH ; Junho MUN ; Kyoung Lae KIM ; Yong-Kyu KIM ; Youn Joo CHOI ; Sung Pyo PARK ; Kyeong Ik NA
Annals of Optometry and Contact Lens 2024;23(4):171-177
Purpose:
We examined the association between age-related macular degeneration (AMD) and arthritis.
Methods:
Using data from the Korea National Health and Nutrition Examination Survey for 2017 and 2018, we conducted a complex sample analysis of 6,993 individuals with recorded information on AMD, as well as the diagnosis and treatment of osteoarthritis (OA) and rheumatoid arthritis (RA). We compared the diagnosis and treatment of arthritis between the AMD and control groups using logistic regression analysis, with a specific focus on the treatment among patients with arthritis.
Results:
In the AMD group (n = 1,118) and the control group (n = 5,875), univariate logistic regression analysis showed substantial differences in the diagnosis and treatment of OA and RA. However, after adjusting for age, alcohol consumption, diabetes mellitus, and hypertension in multivariate logistic regression analysis, these differences were no longer substantial. Among patients with OA (n = 246 in the AMD group and n = 821 in the control group), there was a significant association between AMD and OA treatments (odds ratio 1.511, 95% confidence interval 1.051-2.172).
Conclusions
Patients diagnosed with and treated for OA had a higher likelihood of concurrent AMD than those who did not receive treatment. Therefore, ophthalmic examinations and closer monitoring are recommended for these patients.

Result Analysis
Print
Save
E-mail