1.Effectiveness of low-dose mepolizumab in refractory eosinophilic granulomatosis with polyangiitis: systemic steroid use and remission
Mi-Ae KIM ; Ji-Hyun LEE ; Eun-Kyung KIM ; Jung-Hyun KIM ; Jisoo PARK ; Se Hee LEE ; Tae-Bum KIM
The Korean Journal of Internal Medicine 2026;41(1):163-174
Background/Aims:
This study investigated the clinical efficacy of low-dose mepolizumab (100 mg) in controlling severe eosinophilic asthma, aiming to induce eosinophilic granulomatosis with polyangiitis (EGPA) remission and reduce systemic steroid usage. Additionally, we constructed a basic frame for our longitudinal EGPA cohort by collecting serial blood samples before, during, and after mepolizumab treatment in EGPA patients.
Methods:
We conducted a 2-year prospective observational cohort study in patients with uncontrolled severe eosinophilic asthma and refractory EGPA who used systemic steroids (≥ 7.5 mg/day of prednisolone) or other immunosuppressant drugs for at least 6 months. All patients were treated with 100 mg of mepolizumab every 4 weeks for 1 year to control severe eosinophilic asthma and then were followed for an additional 1 year to monitor their disease course. We analyzed total systemic steroid use and EGPA remission/relapse during the study period.
Results:
Three EGPA patients were included in this study and completed 16 study visits over a 2-year period. After 1 year of treatment with mepolizumab (100 mg monthly), all 3 patients were able to reduce their maintenance dose of systemic steroids, with 2 patients completely discontinuing use. These 2 patients achieved EGPA remission during mepolizumab treatment, and their remission status remained stable for 1 year after they stopped receiving the medication.
Conclusions
Low-dose mepolizumab treatment demonstrated clinical efficacy in reducing the maintenance dose of systemic steroids required for severe refractory EGPA. While not all patients achieved EGPA remission with low-dose mepolizumab, some did, and their remission persisted even after treatment discontinuation.
2.Enhanced prediction of left ventricular ejection fraction using electrocardiography with the addition of clinical metadata
Hyun Woong PARK ; Taeseen KANG ; Young-Hoon SEO ; Jae-Hyeong PARK
The Korean Journal of Internal Medicine 2026;41(1):118-130
Background/Aims:
Left ventricular ejection fraction (LVEF) is a key echocardiographic parameter for assessing LV systolic function, guiding the management of many cardiovascular diseases, including heart failure (HF). While traditional electrocardiography (ECG) has been widely used in clinical practice, it has limitations in predicting LVEF. This study investigated the impact of integrating ECG data with metadata, such as age, N-terminal pro B-type natriuretic peptide (NT-proBNP), and sodium levels, to enhance the accuracy of LVEF prediction, especially in HF with reduced ejection fraction (HFrEF, LVEF ≤ 40%).
Methods:
This retrospective study analyzed ECG and metadata from two tertiary teaching hospitals in Korea. A deep neural network (EfficientNet B3) was trained to predict LVEF, incorporating clinical metadata alongside ECG inputs. Model performance was assessed using the area under the curve (AUC) and the coefficient of determination (R2).
Results:
The artificial intelligence (AI) model achieved an AUC of 0.95 when ECG data were combined with age, NT-proBNP, and sodium levels, outperforming models relying on ECG alone (AUC = 0.90). The integration of metadata significantly improved the prediction accuracy, particularly for HFrEF cases. The specificity of the model remained high (96.9%), but sensitivity was relatively low (54.8%), indicating its potential as a screening tool for HFrEF.
Conclusions
The combination of ECG and metadata results using AI enhances the predictive accuracy of HFrEF detection. This approach offers a scalable and noninvasive method for HF screening and risk stratification, particularly in resource-limited settings. Further validation in diverse populations is needed to confirm its clinical utility.
3.Early Diagnostic Changes in Autism Spectrum Disorder: A Retrospective Study
Jung Sook YEOM ; Young-Soo KIM ; Ji Sook PARK ; Eun Sil PARK ; Ji-Hyun SEO ; Jae-Young LIM ; Hyang-Ok WOO
Annals of Child Neurology 2026;34(2):136-143
Purpose:
Autism spectrum disorder (ASD) exhibits heterogeneous developmental trajectories; however, longitudinal studies using the Korean Childhood Autism Rating Scale (K-CARS) are scarce. This study examined diagnostic changes and related developmental characteristics through repeated K-CARS assessments.
Methods:
We retrospectively reviewed the medical records of children who underwent repeated K-CARS assessments between May 2021 and December 2024 at Gyeongsang National University Hospital. Based on diagnostic status at the initial (T1) and follow-up (T2) evaluations, participants were classified as having persistent ASD (ASD at T1 and T2), emerging ASD (non-ASD at T1 but ASD at T2), or desisting ASD (ASD at T1 but non-ASD at T2). Developmental profiles were evaluated using the social quotient (SQ), visual-motor integration (VMI), and language quotients.
Results:
Forty-three children (32 boys; median age, 2.9 years at T1 and 4.3 years at T2) were included. Twenty-two met ASD criteria at T1, and 15 (68%) retained the diagnosis at T2. Across the cohort, 15 (35%) had persistent ASD, 21 (49%) had emerging ASD, and seven (16%) had desisting ASD. The desisting group showed higher baseline VMI and better outcomes at follow-up. The emerging group initially had higher SQ and VMI than the persistent group, but these differences disappeared over time. Higher baseline VMI was associated with desisting status and higher baseline SQ with emerging ASD (odds ratios, 3.14 and 2.59 per standard deviation increase, respectively; P=0.06 and P=0.07).
Conclusion
Early ASD diagnoses were generally stable yet variable, supporting repeated assessment. Baseline VMI and SQ may relate to later diagnostic changes.
4.Peak and Trough Concentration Ranges of Factor Xa Inhibitors for Preventing Thromboembolic Stroke in Korean Patients with Non-valvular Atrial Fibrillation
Jong-Sung PARK ; Kyung Hee LIM ; Dae-Hyun KIM ; Kwang-Min LEE ; Kwang-Sook WOO ; Jin-Yeong HAN
Annals of Laboratory Medicine 2026;46(1):32-40
Background:
Current guidelines recommend factor IIa- or Xa-specific inhibitors over warfarin analogs for preventing thromboembolic stroke in patients with atrial fibrillation (AF).However, their plasma concentrations in Korean patients are not well understood.
Methods:
We conducted a single-center laboratory study to determine the distribution ranges of peak and trough concentrations of three factor Xa inhibitors (apixaban, edoxaban, and rivaroxaban) prescribed for preventing strokes in patients with AF. Patients receiving one of these drugs and undergoing blood specimen collection for laboratory tests were screened. Blood specimens were obtained from patients who had adhered to the prescribed drug regimen consistently for at least 1 week. Drug plasma concentrations were measured using heparin liquid-reagent technology-based anti-Xa chromogenic assays.
Results:
We selected 459 patients who were taking standard or on-label-reduced doses of apixaban (N = 252), edoxaban (N = 182), or rivaroxaban (N = 25). The 5th–95th percentile ranges of the peak concentrations were 84–414 ng/mL (apixaban), 72–424 ng/mL (edoxaban), and 97–517 ng/mL (rivaroxaban). The respective 5th–95th percentile ranges of the trough concentrations were 44–237 ng/mL, 23–93 ng/mL, and 13–219 ng/mL. Approximately 19.6% (apixaban), 33.3% (edoxaban), and 64.0% (rivaroxaban) of patients in each group had peak concentrations out of the predicted distribution ranges based on pharmacokinetic data. Approximately 7.3%, 52.8%, and 8.3% of patients had trough concentrations out of the predicted distribution ranges.
Conclusions
A considerable proportion of Korean patients with AF taking factor Xa inhibitors may require population-specific reference ranges to guide therapeutic monitoring.
5.Development and Validation of a Lectin-independent Liquid Chromatography–Tandem Mass Spectrometry Method for Serum Glycosylated Alpha-fetoprotein Analysis and Comparison with a Liquid-phase Binding Assay
Hyojin KIM ; Juri PARK ; Hanseul SUH ; Saeyoung LEE ; Yoonha PARK ; Won Suk YANG ; Dohsik MINN ; Soon Sun KIM ; Jae Youn CHEONG ; Je-Hyun BAEK
Annals of Laboratory Medicine 2026;46(1):62-71
Background:
Alpha-fetoprotein (AFP) and its isoform AFP-L3 are well-established serum biomarkers for hepatocellular carcinoma (HCC), a common malignancy and a leading cause of cancer-related mortality worldwide. Current methods for measuring these biomarkers are primarily lectin-based assays including the liquid-phase binding assay (LiBA) and liquid chromatography–tandem mass spectrometry (LC-MS/MS), both of which have limitations in diagnostic sensitivity and clinical utility for samples with low AFP concentrations. We aimed to develop a lectin-independent LC-MS/MS method for quantifying fucosylated AFP proteins (AFP-Fuc%).
Methods:
We conducted analytical validation, including method comparisons, over 2 months. The analytical sensitivity and diagnostic performance of this method were evaluated using 525 human serum samples—235 from HCC patients and 290 from non-HCC individuals—and compared with those of LiBA, which measured AFP-L3 levels.
Results:
The LC-MS/MS method demonstrated acceptable within-laboratory imprecision (CVs < 17.1%) without detectable bias, carryover, or matrix effects. Our method exhibited a broader linear dynamic range (spanning five orders of magnitude) and 10-fold higher analytical sensitivity than LiBA. The diagnostic performance of our method was significantly superior to that of LiBA, particularly in patients with low AFP concentrations ( < 7 ng/mL, P < 0.001), with improved accuracy, sensitivity, and precision at a specificity of 96.2%.
Conclusions
The validated LC-MS/MS method demonstrated robust analytical performance and superior diagnostic accuracy over LiBA for HCC diagnosis while avoiding the inherent limitations of lectin-based assays. Our LC-MS/MS assay shows promise for early HCC detection and may contribute to enhanced patient care.
7.Molecular Epidemiology of Extended-spectrum β-Lactamase-producing Escherichia coli in South Korea: A Korean Global Antimicrobial Resistance Surveillance System Report
Dokyun KIM ; SungYoung LEE ; Jun Sung HONG ; Min Hyuk CHOI ; Hyun Soo KIM ; Young Ree KIM ; Young Ah KIM ; Young UH ; Kyeong Seob SHIN ; Jeong Hwan SHIN ; Jeong Su PARK ; Kyoung Un PARK ; Soo Hyun KIM ; Jong Hee SHIN ; Jungsik YU ; Seok Hoon JEONG
Annals of Laboratory Medicine 2026;46(1):72-82
Background:
Extended-spectrum β-lactamase (ESBL)-producing Escherichia coli is among the most important multidrug-resistant pathogens causing bloodstream infections (BSIs).Cefotaximase (CTX-M) enzymes are the most common and highly diverse ESBL family in E.coli. CTX-M-15 in group CTX-M-1 and CTX-M-14 in group CTX-M-9 are the most extensively disseminated enzymes. Multidrug-resistant E. coli strains complicate empirical therapy and increase healthcare burden globally and in Korea. We investigated the molecular epidemiology, sequence types (STs), and ESBL genotypes of E. coli bloodstream isolates in Korea and identified clinical risk factors for cefotaxime resistance.
Methods:
We collected all non-duplicated isolates of E. coli and related clinical information from patients with BSIs at eight sentinel hospitals in the Korean Global Antimicrobial Resistance Surveillance System (Kor-GLASS) collection network during 2017–2021. Duplicate isolates were removed to ensure representativeness of the data. Antimicrobial susceptibility was tested using disk diffusion tests, and multilocus sequence typing and betalactamase genotyping were performed.
Results:
Among 9,232 E. coli blood isolates, resistance rates to cefotaxime and ceftazidime were 36.4% and 11.4%, respectively. Among the clinical factors, age > 65 yrs (adjusted odds ratio [aOR], 1.36), hospital-origin infection (aOR, 2.55), and admission type (intensive care unit [ICU] vs. general ward; aOR, 1.34) were significant cefotaxime resistance risk factors. ST131 was the most prevalent among cefotaxime-resistant E. coli (64.8%, 2,180/3,363), followed by ST1193 (5.3%, N = 177), and ST69 (5.1%, N = 170).ST131, ST648, ST405, and ST410 cefotaxime-resistant E. coli isolates frequently harbored blaCTX-M-15, whereas ST1193 and ST68 showed a high proportion of blaCTX-M-27 carriers, and most ST457 and ST5150 isolates carried blaCTX-M-55.
Conclusions
Continuous monitoring of ESBL-producing E. coli is required to prevent further dissemination, guide empirical therapy, inform infection control policies, and ensure early detection of multidrug-resistant clones with the potential for widespread transmission.
8.Applying National Whole-genome Sequencing Findings for Rare Diseases in Clinical Practice: The Imperative of a Multidisciplinary Approach
Kyung Sun PARK ; Sunghwan SHIN ; Jong-Ho PARK ; Young-Eun KIM ; Won Kyung KWON ; Min-Kyung SO ; Changhee HA ; Ja-Hyun JANG ; Taeheon LEE ; Chang-Seok KI ; Yoonjung KIM ; Kyung-A LEE ; Inho PARK ; Sejoon LEE ; Hong-Hee WON ; ; Jong-Won KIM
Annals of Laboratory Medicine 2026;46(1):94-103
Background:
As nationwide government-led whole-genome sequencing (WGS) projects progress, optimizing the clinical integration of large-scale WGS results is crucial. We explored how the initial analysis from Korea’s First WGS Pilot Study for Rare Diseases was applied in clinical practice, and then we reanalyzed the data comprehensively at Samsung Medical Center (SMC) Seoul, Korea.
Methods:
A prospective cohort study designed to collect WGS data under a Korean national initiative was conducted from August 2020 to December 2021. We focused on patients with rare diseases recruited from 16 university hospitals. The participants included 5,000 individuals (2,200 probands and 2,800 family members). The initial WGS data and diagnostic reference reports (from 682 probands and 484 family members), generated based on the First Korean WGS Pilot Study for Rare Diseases, were subsequently reanalyzed by SMC.
Results:
The initial analysis of the First Korean WGS Pilot Study data revealed a diagnostic rate of 17%. Upon receiving these results, the SMC conducted two rounds of reanalysis, increasing the diagnostic rate from 15% in the first analysis, to 18% in the second, and finally to 24% in the third (P = 1.6 × 10 −5 ). Key factors in improving the genetic diagnosis included increased detection of novel (likely) pathogenic variants (P = 1.0 × 10 −4 ), improved diagnostic rates with larger family recruitment (P = 0.004), and refined clinical information for more precise genotype–phenotype correlation analysis (40%).
Conclusions
Although national WGS projects lay a foundation for rare disease diagnosis, hospital-level reanalysis and multidisciplinary collaborations are crucial for optimizing diagnostic outcomes.
9.Performance Evaluation of the 2020 European Society of Cardiology 0-hour/1-hour Algorithm Using High-sensitivity Cardiac Troponin I for Non-ST-segment Elevation Acute Coronary Syndrome and Mortality Assessment Based on 1-year Real-world Data
Changhee HA ; Yeon Jae LEE ; Jong Do SEO ; Hanah KIM ; Hee-Won MOON ; Mina HUR ; Young Hwan LEE ; Sang O PARK ; Kyeong Ryong LEE ; Hyun-Joong KIM ; Yeo-Min YUN
Annals of Laboratory Medicine 2026;46(1):52-61
Background:
The 2020 European Society of Cardiology (ESC) 0-hr/1-hr algorithm using high-sensitivity cardiac troponin I (hs-cTnI) for non-ST-segment elevation acute coronary syndrome (NSTE-ACS) aims at early diagnosis and shorter emergency department (ED) stays. While this algorithm has been well-established in controlled studies, real-world implementation remains challenging. We evaluated the algorithm’s clinical performance and risk stratification capability in patients with chest pain or discomfort.
Methods:
We measured hs-cTnI in 4,678 patients suspected of NSTE-ACS between August 2022 and July 2023, using an Atellica IM Analyzer (Siemens Healthineers, Erlangen, Germany). We categorized patients into rule-in, observe, or rule-out groups according to the algorithm and assessed its diagnostic performance for NSTE-ACS. The final diagnosis of NSTE-ACS was adjudicated by two independent physicians. Additionally, we evaluated 30-day all-cause mortality, hazard risk, and ED length of stay across the three groups.
Results:
The algorithm categorized 3,408 (72.9%), 573 (12.2%), and 697 (14.9%) patients into the rule-out, observe, and rule-in groups, respectively. Among 90 patients diagnosed as having NSTE-ACS, none were falsely categorized into the rule-out group. Survival analysis revealed significant differences (P < 0.001), with Cox hazard ratios of 2.38 (95% confidence interval: 1.20–4.71) and 6.39 (3.45–11.86) in the observe and rule-in groups, respectively. ED stays shortened in the order of rule-out, observe, and rule-in groups (P < 0.001).
Conclusions
The 2020 ESC 0-hr/1-hr algorithm demonstrates excellent diagnostic accuracy without false rule-outs and effective risk stratification, and contributes to efficient ED throughput, supporting its clinical utility in real-world emergency settings.
10.Considerations of Flow Cytometric Lymphocyte Subset Analysis in Korea Based on a Survey of Current Clinical Laboratory Practice
Mikyoung PARK ; Hyun-Woo CHOI ; Jihyang LIM ; Kyung-Hwa SHIN ; Eun-Jee OH ; Jaewoo SONG ; Kyeong-Hee KIM ; In Hwa JEONG ; Joo-Heon PARK ; Sang-Hyun HWANG ; Eun-Suk KANG
Annals of Laboratory Medicine 2026;46(2):220-225
Flow cytometric lymphocyte subset analysis (FCLSA) is essential for assessing immune status across various diseases and clinical settings. We surveyed current clinical laboratory practices related to FCLSA to establish a baseline reference for future standardization in Korea. Nine university hospitals actively performing FCLSA responded to the 22-question survey, which covered seven categories of laboratory practice. These hospitals used commercial reagent antibody kits from either Beckton Dickinson Biosciences (N = 4) or Beckman Coulter Diagnostics (N = 5). Most hospitals performed daily instrument setup and scheduled maintenance every 2–6 months. Two levels of commercial quality control materials were routinely used each day. Sample and reagent antibody volumes varied across hospitals, even when the same reagent kit was used. Acquired cell counts ranged from 5 × 10 3 to 5 × 10 4 cells, with two hospitals adjusting counts based on the cell type analyzed. Most laboratories reported percentages and general opinions; some additionally reported white blood cell and lymphocyte counts, along with lymphocyte percentages. This is the first comprehensive survey on the clinical laboratory practice of FCLSA in Korea.Standardization of FCLSA should be accelerated to ensure reliable and reproducible results.

Result Analysis
Print
Save
E-mail