1.One-stage mandibular reconstruction combining iliac flap with immediate implant-based denture.
Yifan KANG ; Yanjun GE ; Xiaoming LV ; Shang XIE ; Xiaofeng SHAN ; Zhigang CAI
Journal of Peking University(Health Sciences) 2025;57(1):78-84
OBJECTIVE:
To evaluate the clinical outcomes and define the indications for a one-stage mandibular reconstruction technique that combines iliac bone flaps with immediate implant-based dentures, and to assess both the accuracy of surgical planning and the long-term success of the procedure.
METHODS:
A total of ten patients underwent the procedure at Peking University Hospital of Stomatology between June 2020 and August 2023. The preoperative biopsy pathology of all the patients confirmed a benign tumor. In this technique, iliac bone flaps were used for mandibular reconstruction, and immediate implant-based dentures were placed during the same surgical session. Various outcome measures were evaluated, including the accuracy of the surgical reconstruction, implant placement deviations (entry point, apical point, depth, and angle), and long-term outcomes, such as cervical bone resorption, implant survival, and the cumulative survival rate.
RESULTS:
Thirty-eight implants were successfully inserted into the iliac flaps of the ten patients. The median follow-up duration was 23.5 months, and no significant complications occurred during the follow-up period, such as infections, titanium plate exposure, implant loosening, or damage to the implants and dentures. The accuracy of preoperative virtual surgical planning (VSP) was highly reliable. The repeatability of the VSP model compared to the postoperative reconstructed mandible was as follows: 67.82% ±10.16% within 1 mm, 82.14% ±6.58% within 2 mm, and 90.61% ±4.62% within 3 mm. The average maximum deviation from the plan was (6.10±0.89) mm, with an average overall deviation of (1.14±0.31) mm. For the implants, deviations in critical parameters were as follows: entry point deviation was (2.02±0.58) mm, apical point deviation was (2.25± 0.66) mm, depth deviation was (1.26±0.51) mm, and angular deviation was 1.84°±1.10°. The implant survival rate remained 100% during the follow-up, with a cumulative survival rate of 97.37% from 1 to 4 years. Average cervical bone resorption was 0.94 mm.
CONCLUSION
The combination of iliac bone flaps with immediate implant-based dentures for one-stage mandibular reconstruction demonstrated pro-mising clinical outcomes, including high implant survival and minimal complications. This technique proved to be safe and reliable for mandibular reconstruction. However, further studies with larger sample sizes and longer follow-up periods are necessary to confirm the long-term efficacy and optimal indications for this procedure.
Humans
;
Mandibular Reconstruction/methods*
;
Male
;
Ilium/surgery*
;
Female
;
Middle Aged
;
Surgical Flaps
;
Adult
;
Mandible/surgery*
;
Aged
;
Dental Implantation, Endosseous/methods*
;
Immediate Dental Implant Loading/methods*
;
Bone Transplantation/methods*
;
Dental Implants
2.Accuracy of dynamic navigation system for immediate dental implant placement.
Hong LI ; Feifei MA ; Jinlong WENG ; Yang DU ; Binzhang WU ; Feng SUN
Journal of Peking University(Health Sciences) 2025;57(1):85-90
OBJECTIVE:
Dynamic navigation approaches are widely employed in the context of implant placement surgery. Implant surgery can be divided into immediate and delayed surgery according to the time of implantation. This retrospective study was developed to compare the accuracy of dynamic navigation system for immediate and delayed implantations.
METHODS:
In the study, medical records from all patients that had undergone implant surgery between August 2019 and June 2021 in the First Clinical Division of the Peking University School and Hospital of Stomatology were retrospectively reviewed. There were 97 patients [53 males and 44 females, average age (47.14±11.99) years] and 97 implants (delayed group: 51; immediate group: 46) that met with study inclusion criteria and were included. Implant placement accuracy was measured by the superposition of the planned implant position in the preoperative cone beam computed tomography (CBCT) image and the actual implant position in the postoperative CBCT image. The 3-dimensional (3D) entry deviation (3D deviation in the coronal aspect of the alveolar ridge), 3D apex deviation (3D deviation in the apical area of the implant) and angular deviation were analyzed as the main observation index when comparing these two groups. The 2-dimensional (2D) horizontal deviation of the entry point and apex point, and the deviation of entry point depth and apex point depth were the secondary observation index.
RESULTS:
The overall implant restoration survival rate was 100%, and no mechanical or biological complications were reported. The implantation success rate was 100%. The 3D entry deviation, 3D apex deviation and angular deviation of all analyzed implants were (1.146±0.458) mm, (1.276±0.526) mm, 3.022°±1.566°, respectively; while in the delayed group these respective values were (1.157±0.478) mm, (1.285±0.481) mm and 2.936°±1.470° as compared with (1.134±0.440) mm, (1.265±0.780) mm, 3.117°±1.677° in the immediate group. No significant differences (P=0.809, P=0.850, P=0.575) in accuracy were observed when comparing these two groups.
CONCLUSION
Dynamic computer-assisted implant surgery system promotes accurate implantation, and both the immediate and delayed implantations exhibit similar levels of accuracy under dynamic navigation system that meets the clinical demands. Dynamic navigation system is feasible for immediate implantation.
Humans
;
Male
;
Female
;
Retrospective Studies
;
Middle Aged
;
Cone-Beam Computed Tomography
;
Dental Implantation, Endosseous/methods*
;
Surgery, Computer-Assisted/methods*
;
Dental Implants
;
Adult
;
Surgical Navigation Systems
;
Immediate Dental Implant Loading/methods*
;
Imaging, Three-Dimensional
3.Clinical efficacy of demineralized dentin matrix particles in immediate implantation for bone defects in posterior region: a 1 to 5-year follow-up study.
Hao WU ; Ning CAO ; Liangwei CAO ; Fei YU ; Xu ZHANG ; Shibo WEI ; Hongwu WEI ; Shuigen GUO
West China Journal of Stomatology 2025;43(4):570-583
OBJECTIVES:
This study aims to evaluate the short- to medium-term clinical efficacy of demineralized dentin matrix (DDM) particles applied during the immediate implantation of alveolar bone defects in the posterior region.
METHODS:
A total of 76 patients with 110 simple taper retentive implants were included in the conducted study and divided into Groups A and B in accordance with the bone grafting materials. Cone beam computed tomography and panoramic radiographs were taken immediately after implant surgery, immediate crown repair, and final follow-up time. The average follow-up time for Groups A and B was recorded. The primary observed clinical indicators were overall survival rate of the implant, bone resorption of the mesial and distal margins of the implant, buccal bone width resorption at the platform level and 1 mm below the platform, and bone height of the implant. Implant complication was a secondary observed clinical indicator.
RESULTS:
During the 1-to-5-year follow-up observation period, the mean follow-up of Group A was 38.2 months while that of Group B was 39.9 months. In Group A, two implants failed, one of which fractured, and implant overall survival rate was 96.4%. Four implants failed in Group B due to peri-implantitis, and implant overall survival rate was 92.6%. No statistically significant difference in implant overall survival rate was found between the two groups (P>0.05). In Group A, the average bone resorption in the mesial and distal margins of the implants was (1.011±2.047) mm and (0.841±2.183) mm, respectively. In Group B, the average bone resorption of the mesial and distal margins of the implants was (1.546±1.778) mm and (1.431±1.909) mm, respectively. No statistically significant difference was noted between the two groups (P>0.05). In Group A, buccal bone width resorption at the platform level and 1 mm below the platform of the implant was (0.782±2.084) mm and (0.681±2.307) mm, respectively. In Group B, buccal bone width resorption at the platform level and 1 mm below the platform of implant was (1.071±1.474) mm and (0.949±1.909) mm, respectively. No statistically significant difference was found between the two groups (P>0.05). In Group A, the buccal bone height of resorption of the implant was (1.044±2.214) mm. In Group B, the buccal bone height of resorption of the implant was (1.075±1.456) mm. No statistically significant difference in bone height was observed between the two groups (P>0.05).
CONCLUSIONS
During the 1-to-5-year follow-up observation period, DDM particles can effectively increase the height and width of alveolar bone, and they can achieve the same effect of maintaining alveolar bone contour and bone augmentation compared with deproteinized inorganic calf bone. DDM particles can be used as a potential new bone grafting material for the treatment of bone defects in clinical practice.
Humans
;
Follow-Up Studies
;
Dentin
;
Cone-Beam Computed Tomography
;
Dental Implants
;
Male
;
Female
;
Adult
;
Alveolar Bone Loss/surgery*
;
Middle Aged
;
Bone Transplantation
;
Radiography, Panoramic
;
Dental Implantation, Endosseous/methods*
;
Immediate Dental Implant Loading
4.Feasibility analysis of immediate implant placement in the maxillary molar region.
Wen Hui YU ; Lu LIU ; Jian Jun YANG ; Hui ZHAO ; Xi Tao LI
Chinese Journal of Stomatology 2022;57(3):251-257
Objective: To study the clinical outcomes and feasibility of immediate implantation after flap surgery and minimally invasive extraction in the maxillary molar area and to provide a reference for it. Methods: Forty-one patients (41 molars in total) with maxillary molars that could not be preserved, treated from June 2018 to June 2020 at the Department of Oral and Maxillofacial Surgery at the Affiliated Hospital of Qingdao University, were selected. There are 24 males and 17 females with the age of (49.7±1.8) years (range 18-66 years). Pre-operative cone-beam CT (CBCT) was taken for measurement and analysis. After flap surgery and minimally invasive tooth extraction, the inflammatory granulation tissues attached to the soft and hard tissues were completely scraped and clipped, followed by the preparation of the implants in the correct three-dimensional position. Torque value and implant stability quotient (ISQ) were recorded after implant placement and with non-submerged healing. CBCT examination was taken 6 months after surgery and ISQ value was checked before crown restoration. CBCT examination was also taken 1 year after the permanent restoration. The survival rate of 6 months after surgery, the success rate of 1 year after permanent restoration, and the size of jump gaps immediately after surgery, 6 months after surgery, 1 year after permanent restoration respectively, were performed. The ISQ values were compared immediately and 6 months after surgery. Results: A total of 41 implants were placed in 41 patients. Six months after surgery, the survival rate was 100% (41/41). Twelve months after permanent restoration, the success rate of the implant restoration was 100% (41/41). The torque value after implant implantation was (42.77±0.79) N·cm. The buccal and palatal jump gaps were (3.15±0.16) mm and (2.86±0.18) mm immediately after surgery, respectively. The mesial and distal jump gaps were (2.94±0.19) mm and (3.77±0.21) mm, respectively. CBCT showed that no jump gap around the implants at 6 months after surgery and 1 year after permanent restoration. The ISQ values at immediately and 6 months after surgery were (74.78±0.59) and (80.20±0.49) respectively, and the difference was statistically significant (t=-9.03, P<0.001). Conclusions: Immediate dental implantation in the correct three-dimensional position could achieve good osseointegration by means of flap surgery, minimally invasive extraction and thorough removal of inflammatory tissue on the surface of soft and hard tissues. The clinical outcomes were satisfactory.
Adolescent
;
Adult
;
Aged
;
Dental Implantation, Endosseous/methods*
;
Dental Implants
;
Feasibility Studies
;
Female
;
Humans
;
Immediate Dental Implant Loading
;
Male
;
Middle Aged
;
Molar/surgery*
;
Young Adult
5.Immediate implantation following tooth extraction in fresh maxillary molar socket with poor bone quality.
Journal of Southern Medical University 2019;39(1):100-105
OBJECTIVE:
To explore the feasibility of immediate implantation after tooth extraction in the maxillary molar socket with poor bone quality beneath the sinus.
METHODS:
We collected the data from the patients undergoing extraction of maxillary molars with poor bone quality between the sockets and sinuses. Sinus lifting and immediate implant following the extraction were performed simultaneously in these cases, and the primary stability of the implants, wound healing, and changes of the sinus were observed. At 6 months after the operations, the crowns were installed on the implants. The masticatory function was observed, and the growth of the alveolar bones and their changes after the operations were examined using microcomputed tomography (MCT).
RESULTS:
We analyzed 32 extraction cases with immediate implantation in the maxillary molar sockets with poor bone quality beneath the sinus. The average age of the patients was 59.8 years, and the length and diameter of the implant ranged from 8.5 to 10 mm and from 4.5 to 5.5 mm, respectively. The torque force of the implants varied from the minimum (in which cases the implants remained fixed after insertion with fingers) to the maximum of 30 N·cm. The postoperative recovery was uneventful in all the cases and no failed or movable implants were found. At 6 months after the operation, none of the patients showed abnormalities in the sinus, and in all the cases the crowns were successfully installed on the implants with good recovery of the masticatory functions. Follow-up of the patients for 12 to 96 months after the operation showed successful immediate implantation in all the cases. After the operation, the changes of the mean alveolar ridge heights on the buccal, palatal, mesial, and distal sides of the patients were 0.8069±0.6253 mm (=1.2904, >0.1), 0.5272± 0.3331 mm (=1.5836, >0.05), 0.5416±0.4048 mm (=1.3379, >0.05), and 0.5172±0.3874 mm (=1.3351, >0.05), respectively; the change of the alveolar ridge width was 0.5522±0.4381 mm (=1.2604, >0.1) mm. The dimension of the alveolar bone underwent no significant changes after the operation in these patients.
CONCLUSIONS
Immediate implantation in the maxillary extraction socket with a poor bone quality can avoid damages to the sinus and achieve good outcomes with such advantages of less trauma, full use of the innate gingiva and alveolar ridge, and well preserved morphology of the alveolar ridge as compared with delayed implantation.
Dental Implantation
;
methods
;
Dental Implants, Single-Tooth
;
Feasibility Studies
;
Humans
;
Immediate Dental Implant Loading
;
methods
;
Maxilla
;
Middle Aged
;
Molar
;
surgery
;
Tooth Extraction
;
Tooth Socket
;
Treatment Outcome
;
X-Ray Microtomography
6.A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period.
Hyun Joo KIM ; Yeun Kang KIM ; Ji Young JOO ; Ju Youn LEE
Journal of Periodontal & Implant Science 2017;47(2):106-115
PURPOSE: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. METHODS: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. RESULTS: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. CONCLUSIONS: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.
Clinical Study*
;
Dental Implants
;
Dentistry
;
Female
;
Humans
;
Immediate Dental Implant Loading
;
Male
;
Methods
;
Osseointegration
;
Prospective Studies*
;
Prostheses and Implants
;
Torque
7.Severe periodontitis teeth after extraction of the alveolar ridge preservation and comprehensive treatment.
Bo PENG ; Sheng-qi ZANG ; Fang CHEN
Chinese Journal of Stomatology 2012;47(5):314-317
Alveolar Bone Loss
;
prevention & control
;
Alveolar Process
;
surgery
;
Bone Regeneration
;
Dental Implantation, Endosseous
;
Dental Prosthesis, Implant-Supported
;
Guided Tissue Regeneration, Periodontal
;
methods
;
Humans
;
Immediate Dental Implant Loading
;
Male
;
Middle Aged
;
Periodontitis
;
surgery
;
Tooth Extraction
;
adverse effects
;
Wound Healing
8.Clinical study of computer-guided implant surgery and immediate fixed restoration in complete edentulous cases.
Shu-jie CHEN ; Xiu-lian HU ; Ping DI
Chinese Journal of Stomatology 2012;47(4):250-252
Aged
;
Female
;
Humans
;
Immediate Dental Implant Loading
;
methods
;
Jaw, Edentulous
;
diagnostic imaging
;
rehabilitation
;
surgery
;
Male
;
Mandible
;
diagnostic imaging
;
surgery
;
Maxilla
;
diagnostic imaging
;
surgery
;
Middle Aged
;
Radiography, Panoramic
;
Surgery, Computer-Assisted
;
methods
9.Design of clinical rehabilitation of immediately loaded implants.
Chinese Journal of Stomatology 2010;45(4):252-255
Animals
;
Dental Implantation, Endosseous
;
Dental Implants
;
Dental Implants, Single-Tooth
;
Denture, Complete, Immediate
;
Denture, Partial, Immediate
;
Humans
;
Immediate Dental Implant Loading
;
methods
;
Jaw, Edentulous
;
rehabilitation
;
Jaw, Edentulous, Partially
;
rehabilitation
;
Mandible
;
Maxilla

Result Analysis
Print
Save
E-mail