1.Reconstruction of a partial maxillectomy defect using a pedicled buccal fat pad flap in an elderly oral squamous cell carcinoma patient
Soon-Young KANG ; Min-Hyung CHOI ; Seong-Gon KIM
Oral Biology Research 2026;50(1):2-
Oral squamous cell carcinoma (OSCC) is the most common malignant tumor of the oral cavity, with rising incidence among patients of advanced age. We present the case of a 90-year-old woman with OSCC of the left posterior maxilla, treated by mass excision followed by immediate reconstruction using a pedicled buccal fat pad (BFP) flap. The flap provided reliable coverage, demonstrated robust vascularity, and achieved complete epithelialization within 6 weeks. Postoperative healing was uneventful, with no evidence of infection, necrosis, or other complications. This case underscores that, even in patients of advanced age, surgical excision combined with BFP reconstruction—when guided by individualized clinical decision-making and consideration of significant geriatric constraints such as frailty and limited anesthetic tolerance—can yield predictable functional outcomes while minimizing operative time and morbidity.
2.Psychosocial Factors Associated With Depressive Symptoms Among University Hospital Nurses
Seung-Gon KIM ; Eun Hyun SEO ; Young Joon AHN ; Hyung-Jun YOON
Journal of the Korean Society of Biological Therapies in Psychiatry 2026;32(1):26-36
Objectives:
This study aimed to investigate the prevalence of depressive symptoms among hospital nurses and their associations with psychosocial and job-related factors.
Methods:
A total of 515 nurses at one university hospital participated in this study. Data on demographics, job-related factors, burnout, social conflict, happiness, and ego-resiliency were collected using self-reported questionnaires. Depressive symptoms were assessed using the depressive subscale of the Hospital Anxiety and Depression Scale, with scores of 8 or higher indicating their presence. Demographics, job-related, and psychosocial factors were compared based on the presence of depressive symptoms. Logistic regression analysis was conducted to identify factors associated with depressive symptoms. In addition, the mediating effect of ego-resiliency on the relationship between burnout and depressive symptoms was examined.
Results:
A total of 226 participants (43.9%) were identified as having depressive symptoms. Happiness was associated with a lower risk of depressive symptoms, whereas burnout and social conflict were associated with a higher risk. Furthermore, ego-resiliency showed a significant mediating effect on the relationship between burnout and depressive symptoms. Being a basic or charge nurse; experiencing job dissatisfaction; being exposed to higher levels of burnout and social conflict; and having lower levels of happiness and ego-resiliency were significantly correlated with depressive symptoms.
Conclusions
Our findings suggest that intervention strategies aimed at enhancing happiness and ego-resiliency while reducing burnout and social conflict may help prevent and manage depressive symptoms among hospital nurses.
3.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
4.Accuracy evaluation of preoperative indocyanine green tattooing and intraoperative colonoscopy in determining surgical resection margins for left-sided colorectal cancer: a retrospective study in Korea
Byung-Soo PARK ; Sung Hwan CHO ; Gyung Mo SON ; Hyun Sung KIM ; Jin Ook JANG ; Dae Gon RYU ; Su Jin KIM ; Su Bum PARK ; Hyung Wook KIM
Journal of Minimally Invasive Surgery 2025;28(1):19-24
Purpose:
We aimed to evaluate the precision of preoperative colonoscopic tattooing and intraoperative colonoscopic tumor localization in determining distal surgical margins for leftsided colorectal cancer surgery.
Methods:
This retrospective study included 30 patients who underwent laparoscopic colorectal surgery, preoperative colonoscopic tattooing, and intraoperative colonoscopic localization for colorectal cancer at our center between July 2020 and March 2024. Clinical data were collected, and the precision of these methods was assessed by measuring the differences between the target resection margin and the actual pathological resection margin.
Results:
In four patient cases, the indocyanine green tattoo was not visible in the laparoscopic surgical field. The average stained length of the tattoo was 2.89 cm, with a mean distance of 1.18 cm between the low margin of the tattoo and the cancer. The difference between the target distal resection margin by intraoperative colonoscopic localization and the actual pathological resection margin was 0.88 cm. No complications related to the intraoperative colonoscopy were observed.
Conclusion
Preoperative tattooing showed limitations, such as spreading and occasional invisibility. Intraoperative colonoscopic localization proved to be an effective method for achieving more precise distal surgical margins in left-sided colorectal cancer surgery.
5.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
6.Accuracy evaluation of preoperative indocyanine green tattooing and intraoperative colonoscopy in determining surgical resection margins for left-sided colorectal cancer: a retrospective study in Korea
Byung-Soo PARK ; Sung Hwan CHO ; Gyung Mo SON ; Hyun Sung KIM ; Jin Ook JANG ; Dae Gon RYU ; Su Jin KIM ; Su Bum PARK ; Hyung Wook KIM
Journal of Minimally Invasive Surgery 2025;28(1):19-24
Purpose:
We aimed to evaluate the precision of preoperative colonoscopic tattooing and intraoperative colonoscopic tumor localization in determining distal surgical margins for leftsided colorectal cancer surgery.
Methods:
This retrospective study included 30 patients who underwent laparoscopic colorectal surgery, preoperative colonoscopic tattooing, and intraoperative colonoscopic localization for colorectal cancer at our center between July 2020 and March 2024. Clinical data were collected, and the precision of these methods was assessed by measuring the differences between the target resection margin and the actual pathological resection margin.
Results:
In four patient cases, the indocyanine green tattoo was not visible in the laparoscopic surgical field. The average stained length of the tattoo was 2.89 cm, with a mean distance of 1.18 cm between the low margin of the tattoo and the cancer. The difference between the target distal resection margin by intraoperative colonoscopic localization and the actual pathological resection margin was 0.88 cm. No complications related to the intraoperative colonoscopy were observed.
Conclusion
Preoperative tattooing showed limitations, such as spreading and occasional invisibility. Intraoperative colonoscopic localization proved to be an effective method for achieving more precise distal surgical margins in left-sided colorectal cancer surgery.
7.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
8.Accuracy evaluation of preoperative indocyanine green tattooing and intraoperative colonoscopy in determining surgical resection margins for left-sided colorectal cancer: a retrospective study in Korea
Byung-Soo PARK ; Sung Hwan CHO ; Gyung Mo SON ; Hyun Sung KIM ; Jin Ook JANG ; Dae Gon RYU ; Su Jin KIM ; Su Bum PARK ; Hyung Wook KIM
Journal of Minimally Invasive Surgery 2025;28(1):19-24
Purpose:
We aimed to evaluate the precision of preoperative colonoscopic tattooing and intraoperative colonoscopic tumor localization in determining distal surgical margins for leftsided colorectal cancer surgery.
Methods:
This retrospective study included 30 patients who underwent laparoscopic colorectal surgery, preoperative colonoscopic tattooing, and intraoperative colonoscopic localization for colorectal cancer at our center between July 2020 and March 2024. Clinical data were collected, and the precision of these methods was assessed by measuring the differences between the target resection margin and the actual pathological resection margin.
Results:
In four patient cases, the indocyanine green tattoo was not visible in the laparoscopic surgical field. The average stained length of the tattoo was 2.89 cm, with a mean distance of 1.18 cm between the low margin of the tattoo and the cancer. The difference between the target distal resection margin by intraoperative colonoscopic localization and the actual pathological resection margin was 0.88 cm. No complications related to the intraoperative colonoscopy were observed.
Conclusion
Preoperative tattooing showed limitations, such as spreading and occasional invisibility. Intraoperative colonoscopic localization proved to be an effective method for achieving more precise distal surgical margins in left-sided colorectal cancer surgery.
9.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
10.Conventional machine learning-based prediction models did not outperform the International IgA Nephropathy Prediction Tool
Sehoon PARK ; Yisak KIM ; Chung Hee BAEK ; Hyunjeong CHO ; Ji In PARK ; Eun Sil KOH ; Jung Pyo LEE ; Sun-Hee PARK ; Hyung Woo KIM ; Seung Hyeok HAN ; Ho Jun CHIN ; Dong Ki KIM ; Kyung Chul MOON ; Young-Gon KIM ; Hajeong LEE
Kidney Research and Clinical Practice 2025;44(5):802-813
Immunoglobulin A nephropathy (IgAN) is a major cause of end-stage kidney disease (ESKD). The International IgA Nephropathy Prediction Tool (IIgAN-PT) predicts IgAN prognosis, but improvement in the prediction performance using machine learning (ML)-based methods is needed. Methods: We analyzed 4,425 biopsy-confirmed patients with IgAN and ≥6 months of follow-up from nine tertiary university hospitals in Korea. The study population was divided into development and validation cohorts. Using the collected 87 clinicodemographic and pathological variables, ML-based prediction models for ESKD or estimated glomerular filtration rate decline (50% reduction or <15 mL/min/1.73 m2 ) were constructed: 1) the conventional CatBoost model, 2) the optimized CatBoost model with Cox proportional hazards, 3) the deep Cox proportional hazards model, and 4) the deep Cox mixture model. The area under the curve (AUC) and calibration plots were used to investigate the discriminative and calibration performance of the models, which were then compared with those of the IIgAN-PT full model. Results: The full model showed excellent performance (AUC [95% confidence interval] for 5-year outcome, 0.896 [0.853–0.940]), with acceptable calibration results. The ML-based models showed good performance in predicting adverse kidney outcomes and revealed acceptable discrimination performance in the external validation (AUC [95% confidence interval] for the 5-year outcome: 1) 0.829 [0.791–0.866]; 2) 0.847 [0.804–0.890]; 3) 0.823 [0.784–0.862]; and 4) 0.832 [0.794–0.870]), although the models showed underestimation in calibration analysis of the external validation cohort. With the validation data, the overall performance of the IIgAN-PT was non-inferior to that of the ML-based model. Conclusions: Our ML-based models showed good performance in predicting adverse kidney outcomes in patients with IgAN but they did not outperform the IIgAN-PT.

Result Analysis
Print
Save
E-mail