2.Clinical Characteristics and Visual Prognostic Biomarkers in Pericentral Retinitis Pigmentosa: A Study in a South Korean Cohort
Su Ho BAE ; Seung Woo CHOI ; Chang Ki YOON ; Un Chul PARK ; Kyu Hyung PARK ; Eun Kyoung LEE
Korean Journal of Ophthalmology 2025;39(2):157-169
Purpose:
To investigate the clinical characteristics of South Korean patients with pericentral retinitis pigmentosa (RP) and to identify clinical biomarkers associated with rapid visual acuity decline based on baseline factors.
Methods:
This retrospective study included 59 eyes of 31 patients diagnosed with pericentral RP. Comprehensive ophthalmological examinations and genetic sequencing were conducted to assess the baseline characteristics. For biomarker analysis, eyes were categorized into two groups based on the annual rate of change in visual acuity. The clinical findings of the two groups were evaluated to identify the biomarkers associated with rapid loss of visual acuity.
Results:
Patients with pericentral RP in this study exhibited a mean best-corrected visual acuity of 0.17 ± 0.23 in logarithm of the minimum angle of resolution. The visual field test showed annular or semicircular scotoma with relatively preserved periphery and 27 eyes (45.8%) exhibited no macular complications in optical coherence tomography. Genetic analysis identified genes associated with previous typical and pericentral RP studies but also highlighted that many genetic causes of pericentral RP remain unidentified. Of the 55 eyes for which the rate of visual acuity change could be estimated, 18 exhibited an annual decline of ≥10%, whereas 37 showed an annual decline of <10%. Male sex and prolonged b-wave latency on dark-adapted 0.01 electroretinogram correlated with rapid visual acuity decline in the multivariate analysis.
Conclusions
South Korean patients with pericentral RP exhibited a milder phenotype compared to typical RP patients reported in previous studies. Genetic analysis revealed heterogeneity, with mutations in some genes commonly associated with milder forms of RP. Male sex and prolonged b-wave latency on dark-adapted 0.01 electroretinogram were significant biomarkers for predicting rapid visual acuity decline. Monitoring initial b-wave latency is important for predicting visual decline, particularly in male patients with pericentral RP.
4.Clinical Characteristics and Visual Prognostic Biomarkers in Pericentral Retinitis Pigmentosa: A Study in a South Korean Cohort
Su Ho BAE ; Seung Woo CHOI ; Chang Ki YOON ; Un Chul PARK ; Kyu Hyung PARK ; Eun Kyoung LEE
Korean Journal of Ophthalmology 2025;39(2):157-169
Purpose:
To investigate the clinical characteristics of South Korean patients with pericentral retinitis pigmentosa (RP) and to identify clinical biomarkers associated with rapid visual acuity decline based on baseline factors.
Methods:
This retrospective study included 59 eyes of 31 patients diagnosed with pericentral RP. Comprehensive ophthalmological examinations and genetic sequencing were conducted to assess the baseline characteristics. For biomarker analysis, eyes were categorized into two groups based on the annual rate of change in visual acuity. The clinical findings of the two groups were evaluated to identify the biomarkers associated with rapid loss of visual acuity.
Results:
Patients with pericentral RP in this study exhibited a mean best-corrected visual acuity of 0.17 ± 0.23 in logarithm of the minimum angle of resolution. The visual field test showed annular or semicircular scotoma with relatively preserved periphery and 27 eyes (45.8%) exhibited no macular complications in optical coherence tomography. Genetic analysis identified genes associated with previous typical and pericentral RP studies but also highlighted that many genetic causes of pericentral RP remain unidentified. Of the 55 eyes for which the rate of visual acuity change could be estimated, 18 exhibited an annual decline of ≥10%, whereas 37 showed an annual decline of <10%. Male sex and prolonged b-wave latency on dark-adapted 0.01 electroretinogram correlated with rapid visual acuity decline in the multivariate analysis.
Conclusions
South Korean patients with pericentral RP exhibited a milder phenotype compared to typical RP patients reported in previous studies. Genetic analysis revealed heterogeneity, with mutations in some genes commonly associated with milder forms of RP. Male sex and prolonged b-wave latency on dark-adapted 0.01 electroretinogram were significant biomarkers for predicting rapid visual acuity decline. Monitoring initial b-wave latency is important for predicting visual decline, particularly in male patients with pericentral RP.
5.Factors associated with Hypertensive Retinopathy among People with Hypertension: A Systematic Review
Ihn Sook JEONG ; Chan Mi KANG ; Eun Joo LEE ; Seol Bin KIM ; Young Kyung SEO ; Young Shin SON ; Kun Hyung KIM
Journal of Korean Academy of Community Health Nursing 2025;36(1):130-149
Purpose:
The associated factors for hypertensive retinopathy (HTR) are rarely investigated. This study aimed to identify the associated factors for HTR using a systematic review.
Methods:
The review included cross-sectional, case-controlled, and cohort studies on HTR risk factors published in Korean and English with full texts available from PubMed, Embase, CINAHL, Web of Science, and Korean databases. Methodological quality was assessed using the Joanna Briggs Institute (JBI) checklist.
Results:
Eleven studies were finally selected, and three studies including patients with hypertension without diabetes mellitus, older age, male sex, alcohol consumption, the duration of hypertension, hyperglycemia, dyslipidemia, microalbuminuria, high creatinine levels, chronic kidney disease, and cardiovascular changes were identified as factors associated with HTR. Conversely, in the remaining eight studies, younger age, non-smoking status, and renal function indicators (albuminuria, high creatinine levels, chronic kidney disease, and uric acid) were identified as associated factors.
Conclusions
Regardless of the inclusion of patients with diabetes mellitus, impaired kidney functions were determined as significant factors associated with retinopathy in patients with HTR. However, considering a limited number of evidence and lack of evidence to confirm causality, we recommend further research on renal function and HTR.
6.Safety and Efficacy of Pivot-Balloon for Severe Tricuspid Regurgitation:The First-in-Man Experiences
Eun Kyoung KIM ; Min-Ku CHON ; Hyun-Sook KIM ; Yong-Hyun PARK ; Sang-Hyun LEE ; Ki Seok CHOO ; Hyung Gon JE ; Dae-Hee KIM ; Tae Oh KIM ; Yoon Seok KOH ; Jae-Hyeong PARK ; Jae-Hwan LEE ; Young Jin CHOI ; Eun Seok SHIN ; Hyuck-Jun YOON ; Seung-Whan LEE ; Joo-Yong HAHN
Korean Circulation Journal 2025;55(1):20-31
Background and Objectives:
Among various emerging catheter-based treatments for severe tricuspid regurgitation (TR), the spacer device can reduce the regurgitation orifice without manipulating the valve leaflet. However, its clinical application has been hampered by traumatic anchoring to the myocardium and the coaxial alignment of the balloon resulting in insufficient TR reduction. This study aimed to evaluate the early-stage safety, technical feasibility, and preliminary efficacy of the novel atraumatic vertical spacer in patients with isolated severe TR.
Methods:
All procedures were guided by fluoroscopy and transthoracic echocardiography.The maximum device placement time with an inflated balloon was 24 hours. Changes in the amount of TR, right ventricular function, and patient hemodynamics were measured during balloon deployment.
Results:
A total of 7 patients (median age 74), underwent successful device implantation without procedure-related complications. During balloon inflation (median 25 minutes), there were no symptoms or signs indicative of TR intolerance. TR was reduced by 1 grade or greater in all patients, with 2 patients exhibiting a reduction of 3 grades, from torrential TR to a moderate degree. Mild TR after balloon inflation was achieved in 3 patients with baseline severe TR. The TR reduction observed during initial balloon deployment was sustained during the subsequent balloon maintenance period.
Conclusions
The Pivot-balloon procedure was safe, technically feasible, and effective in reducing TR in patients with severe TR. No periprocedural complications or adverse cardiovascular events were reported during device placement with TR reduction observed in all patients. However, longer-term follow-up is needed to confirm safety and treatment effect.
7.Cost-effectiveness of Fractional Flow Reserve Versus Intravascular Ultrasound to Guide Percutaneous Coronary Intervention: Results From the FLAVOUR Study
Doyeon HWANG ; Hea-Lim KIM ; Jane KO ; HyunJin CHOI ; Hanna JEONG ; Sun-ae JANG ; Xinyang HU ; Jeehoon KANG ; Jinlong ZHANG ; Jun JIANG ; Joo-Yong HAHN ; Chang-Wook NAM ; Joon-Hyung DOH ; Bong-Ki LEE ; Weon KIM ; Jinyu HUANG ; Fan JIANG ; Hao ZHOU ; Peng CHEN ; Lijiang TANG ; Wenbing JIANG ; Xiaomin CHEN ; Wenming HE ; Sung Gyun AHN ; Ung KIM ; You-Jeong KI ; Eun-Seok SHIN ; Hyo-Soo KIM ; Seung-Jea TAHK ; JianAn WANG ; Tae-Jin LEE ; Bon-Kwon KOO ;
Korean Circulation Journal 2025;55(1):34-46
Background and Objectives:
The Fractional Flow Reserve and Intravascular UltrasoundGuided Intervention Strategy for Clinical Outcomes in Patients with Intermediate Stenosis (FLAVOUR) trial demonstrated non-inferiority of fractional flow reserve (FFR)-guided percutaneous coronary intervention (PCI) compared with intravascular ultrasound (IVUS)-guided PCI. We sought to investigate the cost-effectiveness of FFR-guided PCI compared to IVUS-guided PCI in Korea.
Methods:
A 2-part cost-effectiveness model, composed of a short-term decision tree model and a long-term Markov model, was developed for patients who underwent PCI to treat intermediate stenosis (40% to 70% stenosis by visual estimation on coronary angiography).The lifetime healthcare costs and quality-adjusted life-years (QALYs) were estimated from the healthcare system perspective. Transition probabilities were mainly referred from the FLAVOUR trial, and healthcare costs were mainly obtained through analysis of Korean National Health Insurance claims data. Health utilities were mainly obtained from the Seattle Angina Questionnaire responses of FLAVOUR trial participants mapped to EQ-5D.
Results:
From the Korean healthcare system perspective, the base-case analysis showed that FFR-guided PCI was 2,451 U.S. dollar lower in lifetime healthcare costs and 0.178 higher in QALYs compared to IVUS-guided PCI. FFR-guided PCI remained more likely to be cost-effective over a wide range of willingness-to-pay thresholds in the probabilistic sensitivity analysis.
Conclusions
Based on the results from the FLAVOUR trial, FFR-guided PCI is projected to decrease lifetime healthcare costs and increase QALYs compared with IVUS-guided PCI in intermediate coronary lesion, and it is a dominant strategy in Korea.
8.Efficacy of Automatic Suction-Type Sonic Toothbrush and Manual Toothbrush in Preschool Children: A Randomized, Controlled Crossover Pilot Study
Su Bin LEE ; Yong Kwon CHAE ; Mi Sun KIM ; Ok Hyung NAM ; Hyo-Seol LEE ; Sung Chul CHOI ; Ko Eun LEE
Journal of Korean Academy of Pediatric Dentistry 2025;52(2):181-192
This study investigated the plaque removal efficacy of a suction-type sonic toothbrush compared to a conventional manual toothbrush in preschool children aged 30 to 59 months. Using a randomized, double-blind, crossover design with a 2-week washout period, 20 pediatric participants were allocated to two study phases, each using either the suction-type sonic toothbrush or the manual toothbrush with caregiver assistance. The plaque removal effectiveness was assessed through the Silness and Löe plaque index and quantitative light-induced fluorescence values, including ΔR30 and ΔR120 indicators of plaque index. The result showed no statistically significant differences in plaque removal efficacy between the two toothbrushes, although both showed similar improvements. Caregiver feedback revealed high acceptability of the suction-type sonic toothbrush due to its convenience and engaging features, such as a light and suction function, which enhanced the tooth brushing experience. Although limited by the short follow-up period and small sample size, the findings suggest that suction-type sonic toothbrushes may offer practical benefits for young children requiring caregiver assistance.
9.Genome Characterization of Streptococcus mitis KHUD 011 Isolated from the Oral Microbiome of a Healthy Korean Individual
Eun-Young JANG ; Doyun KU ; Seok Bin YANG ; Cheul KIM ; Jae-Hyung LEE ; Ji-Hoi MOON
Journal of Korean Dental Science 2025;18(1):20-29
Purpose:
This study aimed to perform a genome characterization of Streptococcus mitis KHUD 011, a strain isolated from the oral microbiome of a healthy Korean individual, and to compare its genomic features with other S. mitis strains.
Materials and Methods:
The strain was identified through 16S rRNA gene sequencing, and its genome was sequenced using the PacBio Sequel II platform. De novo assembly and annotation were performed, followed by comparative genomic analysis with three additional strains (S. mitis NCTC 12261, S022-V3-A4, and B6). Pan-genome and phylogenetic analyses were conducted to identify strain-specific genes and assess inter-strain genomic diversity.
Results:
The genome of S. mitis KHUD 011 consisted of 1,782 protein-coding genes, with a G+C content of 40.24%. Pan-genome analysis identified 1,263 core gene clusters (50.0%), 496 dispensable clusters (19.7%), and 763 strain-specific clusters (30.3%). KHUD 011 displayed 88 strain-specific genes, particularly associated with cell wall/membrane biogenesis, transcriptional regulation, and carbohydrate metabolism. Phylogenetic analysis placed KHUD 011 closely with NCTC 12261, forming a distinct cluster apart from other strains.
Conclusion
The genome characterization of S. mitis KHUD 011 underscores substantial inter-strain genomic diversity influenced by host interactions, ecological niches, and health status. The identified strain-specific genes, particularly those associated with cell wall/ membrane biogenesis, transcriptional regulation, and carbohydrate metabolism, suggest adaptations to the oral microbiome and its interaction with the host. These findings highlight the ecological versatility of S. mitis and the importance of exploring strains from diverse environments to better understand their role within the host and the broader microbiome.
10.Gaps and Similarities in Research Use LOINC Codes Utilized in Korean University Hospitals: Towards Semantic Interoperability for Patient Care
Kuenyoul PARK ; Min-Sun KIM ; YeJin OH ; John Hoon RIM ; Shinae YU ; Hyejin RYU ; Eun-Jung CHO ; Kyunghoon LEE ; Ha Nui KIM ; Inha CHUN ; AeKyung KWON ; Sollip KIM ; Jae-Woo CHUNG ; Hyojin CHAE ; Ji Seon OH ; Hyung-Doo PARK ; Mira KANG ; Yeo-Min YUN ; Jong-Baeck LIM ; Young Kyung LEE ; Sail CHUN
Journal of Korean Medical Science 2025;40(1):e4-
Background:
The accuracy of Logical Observation Identifiers Names and Codes (LOINC) mappings is reportedly low, and the LOINC codes used for research purposes in Korea have not been validated for accuracy or usability. Our study aimed to evaluate the discrepancies and similarities in interoperability using existing LOINC mappings in actual patient care settings.
Methods:
We collected data on local test codes and their corresponding LOINC mappings from seven university hospitals. Our analysis focused on laboratory tests that are frequently requested, excluding clinical microbiology and molecular tests. Codes from nationwide proficiency tests served as intermediary benchmarks for comparison. A research team, comprising clinical pathologists and terminology experts, utilized the LOINC manual to reach a consensus on determining the most suitable LOINC codes.
Results:
A total of 235 LOINC codes were designated as optimal codes for 162 frequent tests.Among these, 51 test items, including 34 urine tests, required multiple optimal LOINC codes, primarily due to unnoted properties such as whether the test was quantitative or qualitative, or differences in measurement units. We analyzed 962 LOINC codes linked to 162 tests across seven institutions, discovering that 792 (82.3%) of these codes were consistent. Inconsistencies were most common in the analyte component (38 inconsistencies, 33.3%), followed by the method (33 inconsistencies, 28.9%), and properties (13 inconsistencies, 11.4%).
Conclusion
This study reveals a significant inconsistency rate of over 15% in LOINC mappings utilized for research purposes in university hospitals, underlining the necessity for expert verification to enhance interoperability in real patient care.

Result Analysis
Print
Save
E-mail