1.Optimization of Natural Killer Cell Expansion with K562-mbIL-18/-21 Feeder Cells and Assurance of Feeder Cell-Free Products
Hantae JO ; Yujung JO ; Seung Kwon KOH ; Mijeong LEE ; Jinho KIM ; SoonHo KWEON ; Jeehun PARK ; Hyun‑Young KIM ; Duck CHO
Annals of Laboratory Medicine 2026;46(2):180-189
Background:
Cancer cell line-derived feeder cells enhance natural killer (NK) cell expansion; however, concerns regarding viable residual feeder cells in the final product limit their use. Evidence supporting the safety of NK-sensitive K562-based feeders, even when irradiated, is scarce. We optimized an NK cell expansion protocol using genetically engineered K562-mbIL-18/-21 (GE-K562) feeder cells and clinical-grade media and confirmed the absence of residual feeder cells.
Methods:
NK cell expansion efficiency was compared between feeder-free and feederbased systems using CTS NK-Xpander Medium. To achieve optimal NK expansion, various peripheral blood mononuclear cell (PBMC)-to-feeder ratios and re-stimulation frequencies were tested over 21 days. Flow cytometry and BCR::ABL1 quantitative reverse transcription PCR (RT-qPCR) were used to confirm the absence of feeder cells in the final NK cell product.
Results:
Feeder-based systems showed superior NK cell fold expansion compared with that of feeder-free systems. Among feeder-based conditions, NK cells expanded 5,224-fold at a 2:1 PBMC-to-feeder ratio after 3 weeks, relative to 1,450-fold at a 6:1 ratio (P < 0.05).Re-stimulation on days 7 and 14 further increased expansion up to 261,457-fold. Irradiated feeder cells showed no proliferation and were eliminated within 3–6 days. On day 21, flow cytometry and BCR::ABL1 RT-qPCR results confirmed the absence of residual feeder cells.
Conclusions
Our optimized NK cell expansion protocol using irradiated GE-K562 feeder cells and clinical-grade media offers a safe and scalable approach to generating large numbers of NK cells, supporting its potential use in clinical immunotherapy applications.
2.Natural Killer Cell Assays: Clinical Applications and Future Directions
Minjeong NAM ; Wooseok PARK ; Hyun-Young KIM ; Duck CHO
Annals of Laboratory Medicine 2026;46(3):244-256
Natural killer (NK) cells play critical roles in immune surveillance and homeostasis maintenance through cytotoxicity and cytokine release. The ability of NK cells to eliminate target cells without the need for prior antigen recognition or antibody involvement has drawn considerable attention for translational and clinical applications. As clinical applications continue to broaden, interest in NK cell assays has been growing markedly. This review provides an in-depth discussion of current clinical applications of NK cell assays, including NK cell phenotype, frequency, and functional activity assessments. This review further highlights the diagnostic potential of these assays in terms of hemophagocytic lymphohistiocytosis and potential NK cell biomarker candidates in diverse pathological contexts, such as cancer, infection, autoimmune diseases, and other diseases. By integrating clinical insights with technological advancements, NK cell assays can serve as valuable tools for disease diagnosis, prognosis, and therapeutic monitoring.
3.Annual Report of the Korean External Quality Assessment Service on General Transfusion Medicine and General Transfusion Antibody Tests (2024)
Han Joo KIM ; Hyungsuk KIM ; Duck CHO ; Dae-Hyun KO
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):1-5
This report provides a summary of the 2024 survey results on the external quality assessment (EQA) scheme for the general transfusion medicine test and the general transfusion antibody test programs in Korea. Proficiency testing materials were prepared at the Asan Medical Center for bi-annual distribution to participating laboratories. The accuracy rates and number of participating laboratories for the bi-annual EQAs were: ABO typing, 99.6%–99.9% (n=944, n=945); RhD typing, 99.9%–100.0% (n=929, n=930);crossmatching, 95.0%–99.2% (n=825, n=825); unexpected antibody scre ening, 99.5%–100.0% (n=363, n=367); direct antiglobulin test (DAT) using a polyspecific reagent, 99.3%–100.0% (n=296, n=299); DAT using an antiimmunoglobulin G monospecific reagent, 100.0% (n=74, n=72); and DAT using an anti-C3d monospecific reagent, 98.6%–100.0% (n=72, n=71). The 2024 EQA scheme for the transfusion medicine program has improved and maintained the standards of the participating laboratories.
4.Annual Report of the Korean External Quality Assessment Service on General Transfusion Medicine and General Transfusion Antibody Tests (2024)
Han Joo KIM ; Hyungsuk KIM ; Duck CHO ; Dae-Hyun KO
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):1-5
This report provides a summary of the 2024 survey results on the external quality assessment (EQA) scheme for the general transfusion medicine test and the general transfusion antibody test programs in Korea. Proficiency testing materials were prepared at the Asan Medical Center for bi-annual distribution to participating laboratories. The accuracy rates and number of participating laboratories for the bi-annual EQAs were: ABO typing, 99.6%–99.9% (n=944, n=945); RhD typing, 99.9%–100.0% (n=929, n=930);crossmatching, 95.0%–99.2% (n=825, n=825); unexpected antibody scre ening, 99.5%–100.0% (n=363, n=367); direct antiglobulin test (DAT) using a polyspecific reagent, 99.3%–100.0% (n=296, n=299); DAT using an antiimmunoglobulin G monospecific reagent, 100.0% (n=74, n=72); and DAT using an anti-C3d monospecific reagent, 98.6%–100.0% (n=72, n=71). The 2024 EQA scheme for the transfusion medicine program has improved and maintained the standards of the participating laboratories.
5.Annual Report of the Korean External Quality Assessment Service on General Transfusion Medicine and General Transfusion Antibody Tests (2024)
Han Joo KIM ; Hyungsuk KIM ; Duck CHO ; Dae-Hyun KO
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):1-5
This report provides a summary of the 2024 survey results on the external quality assessment (EQA) scheme for the general transfusion medicine test and the general transfusion antibody test programs in Korea. Proficiency testing materials were prepared at the Asan Medical Center for bi-annual distribution to participating laboratories. The accuracy rates and number of participating laboratories for the bi-annual EQAs were: ABO typing, 99.6%–99.9% (n=944, n=945); RhD typing, 99.9%–100.0% (n=929, n=930);crossmatching, 95.0%–99.2% (n=825, n=825); unexpected antibody scre ening, 99.5%–100.0% (n=363, n=367); direct antiglobulin test (DAT) using a polyspecific reagent, 99.3%–100.0% (n=296, n=299); DAT using an antiimmunoglobulin G monospecific reagent, 100.0% (n=74, n=72); and DAT using an anti-C3d monospecific reagent, 98.6%–100.0% (n=72, n=71). The 2024 EQA scheme for the transfusion medicine program has improved and maintained the standards of the participating laboratories.
6.Annual Report of the Korean External Quality Assessment Service on General Transfusion Medicine and General Transfusion Antibody Tests (2024)
Han Joo KIM ; Hyungsuk KIM ; Duck CHO ; Dae-Hyun KO
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):1-5
This report provides a summary of the 2024 survey results on the external quality assessment (EQA) scheme for the general transfusion medicine test and the general transfusion antibody test programs in Korea. Proficiency testing materials were prepared at the Asan Medical Center for bi-annual distribution to participating laboratories. The accuracy rates and number of participating laboratories for the bi-annual EQAs were: ABO typing, 99.6%–99.9% (n=944, n=945); RhD typing, 99.9%–100.0% (n=929, n=930);crossmatching, 95.0%–99.2% (n=825, n=825); unexpected antibody scre ening, 99.5%–100.0% (n=363, n=367); direct antiglobulin test (DAT) using a polyspecific reagent, 99.3%–100.0% (n=296, n=299); DAT using an antiimmunoglobulin G monospecific reagent, 100.0% (n=74, n=72); and DAT using an anti-C3d monospecific reagent, 98.6%–100.0% (n=72, n=71). The 2024 EQA scheme for the transfusion medicine program has improved and maintained the standards of the participating laboratories.
7.Annual Report of the Korean External Quality Assessment Service on General Transfusion Medicine and General Transfusion Antibody Tests (2024)
Han Joo KIM ; Hyungsuk KIM ; Duck CHO ; Dae-Hyun KO
Journal of Laboratory Medicine and Quality Assurance 2025;47(1):1-5
This report provides a summary of the 2024 survey results on the external quality assessment (EQA) scheme for the general transfusion medicine test and the general transfusion antibody test programs in Korea. Proficiency testing materials were prepared at the Asan Medical Center for bi-annual distribution to participating laboratories. The accuracy rates and number of participating laboratories for the bi-annual EQAs were: ABO typing, 99.6%–99.9% (n=944, n=945); RhD typing, 99.9%–100.0% (n=929, n=930);crossmatching, 95.0%–99.2% (n=825, n=825); unexpected antibody scre ening, 99.5%–100.0% (n=363, n=367); direct antiglobulin test (DAT) using a polyspecific reagent, 99.3%–100.0% (n=296, n=299); DAT using an antiimmunoglobulin G monospecific reagent, 100.0% (n=74, n=72); and DAT using an anti-C3d monospecific reagent, 98.6%–100.0% (n=72, n=71). The 2024 EQA scheme for the transfusion medicine program has improved and maintained the standards of the participating laboratories.
8.Changes in Ocular Surface Status after 25-gauge Pars Plana Vitrectomy
Su Bong CHAE ; Dong Geun KIM ; Hyun Duck KWAK
Journal of the Korean Ophthalmological Society 2024;65(6):369-377
Purpose:
We used a noninvasive ocular surface analyzer to explore changes in the ocular surface parameters of patients who underwent 25-gauge pars plana vitrectomy (PPV).
Methods:
The medical records of 82 patients (163 eyes) who underwent PPV were retrospectively reviewed. The non-invasive tear film break-up time (NIBUT), the lipid layer thickness, meibomian gland loss status, and the tear meniscus height were measured before, and 1 and 3 months after treatment. Consecutive changes in the ocular surface indices of operative and non-operative fellow eyes were statistically compared. Also, factors that reduced the NIBUT at 1 month after surgery were analyzed.
Results:
One month after surgery, the NIBUT was significantly decreased in the operative group compared to before surgery (p = 0.006). Compared to non-operative eyes, the NIBUT of operative eyes decreased significantly 1 month after surgery (p = 0.003). Older age and lower preoperative NIBUT (p = 0.029, p = 0.002) were significantly associated with lower NIBUT 1 month after surgery.
Conclusions
Twenty-five gauge PPV significantly reduces the NIBUT 1 month after surgery.
9.A Case of Ocular Sarcoidosis with an Atypical Presentation of Subretinal Mass
Journal of the Korean Ophthalmological Society 2024;65(6):407-411
Purpose:
To describe a case of ocular sarcoidosis manifesting as an atypical subretinal mass.Case summary: A 59-year-old woman reported reduced visual acuity in her left eye lasting for 1 month. Her best corrected visual acuity in the left eye had diminished to 0.3. A fundus examination revealed a whitish elevated lesion, approximately one disc diameter in size, in the perimacular area of the left eye. Optical coherence tomography identified a hyporeflective oval-shaped mass in the choriocapillaris region accompanied by subretinal fluid. Initial assessment suggested choroidal osteoma with choroidal neovascularization. Consequently, the patient underwent two intravitreal bevacizumab injections, which did not lead to improvement. To rule out systemic diseases, including syphilis, tuberculosis, and sarcoidosis, further radiologic and laboratory tests were conducted. A chest computed tomography highlighted mediastinal lymph node enlargement and pervasive nodules in both lung parenchymata, and serum angiotensin-converting enzyme levels were elevated to 77 U/L. Based on these findings, a diagnosis of sarcoidosis was confirmed, and the patient commenced treatment with oral prednisolone. Eight weeks after treatment, the subretinal lesion and fluid had resolved, and the best corrected visual acuity in the patient’s left eye had improved to 0.9.
Conclusions
Ocular sarcoidosis can manifest as a subretinal mass. This presentation should be differentiated from other subretinal lesions.
10.Clinical Outcomes of Endonasal Dacryocystorhinostomy with Canalicular Trephination in Canalicular Obstruction
Su Yeon HAN ; Jae Hyun OH ; Sang Duck KIM
Journal of the Korean Ophthalmological Society 2024;65(10):651-657
Purpose:
To investigate the surgical outcomes of endonasal dacryocystorhinostomy with canalicular trephination in patients with canalicular obstruction.
Methods:
We retrospectively analyzed the medical records of 37 eyes from 32 patients who were diagnosed with canalicular obstruction between May 2010 and July 2022 and underwent endonasal dacryocystorhinostomy with canalicular trephination to evaluate the success rate and complications.
Results:
In the total patient group, 81.1% achieved complete success in which epiphora completely disappeared, 13.5% had partial success in which epiphora remained but improved, and 5.4% experienced failure in which tearing persisted or worsened. Complications included one case of dacryocystorhinostomy bony opening granuloma and one case of dacryocystorhinostomy bony opening inflammation.
Conclusions
Endonasal dacryocystorhinosomy with canalicular trephination is an effective method for treating canalicular obstruction, offering a high success rate and few complications. It can be considered before resorting to conjunctivodacryocystorhinostomy, which is a more conventional treatment.

Result Analysis
Print
Save
E-mail