1.Full Endoscopic Total Resection of Superior Articular Process for Lumbar Foraminal Decompression
Pius KIM ; Jong Hun SEO ; Hyeun Sung KIM
Journal of Minimally Invasive Spine Surgery and Technique 2026;11(Suppl 1):S53-S62
Objective:
Partial resection of the superior articular process (SAP) is commonly performed during transforaminal endoscopic lumbar foraminotomy (TELF) for the treatment of lumbar foraminal stenosis (LFS). The present study evaluated the efficacy and feasibility of total SAP resection using the selective superior articular process resection (SSAPR) technique, in comparison with conventional TELF.
Methods:
This retrospective cohort study included 79 patients with symptomatic LFS who were treated using TELF (52 segments) or SSAPR (34 segments) between March 2018 and September 2022. Clinical outcomes were evaluated using the visual analogue scale (VAS), Oswestry Disability Index (ODI), and MacNab criteria. Vertebral slippage was measured to assess segmental stability, and postoperative complications were systematically analyzed.
Results:
The study cohort consisted of 79 patients (39 men and 40 women; mean age, 61.9±14.2 years) who were followed for a mean duration of 14.5±2.2 months. At the final follow-up, no significant differences were identified between the TELF and SSAPR groups in VAS or ODI scores (p=0.603 and p=0.776, respectively). Vertebral slippage increased significantly in the TELF group, from 5.49±3.64 mm to 8.75±6.78 mm (p=0.019), whereas only minimal changes were observed in the SSAPR group, from 3.67±3.57 mm to 3.86±3.17 mm (p=0.858). Grade 2 dysesthesia occurred in 12.8% of TELF cases but was not observed in the SSAPR group (p=0.07).
Conclusion
The SSAPR technique provides effective foraminal decompression with improved surgical efficiency and a lower risk of postoperative nerve irritation, while maintaining segmental stability. These findings support the clinical utility of total SAP resection as a safe and viable alternative to conventional partial SAP resection for the treatment of LFS.
3.Effect of Subepithelial Pterygium Pedicle Length on Anterior Corneal Keratometry and Wavefront Aberrations
Eunkyung JANG ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2026;40(2):176-184
Purpose:
To introduce subepithelial pterygium pedicle (SPP) and to investigate the effect of SPP length on the anterior corneal curvature including keratometry and aberrations.
Methods:
In this single-center retrospective cohort, 72 eyes of 72 patients with primary nasal pterygium were analyzed using anterior segment (AS) swept-source optical coherence tomography (SS-OCT; Anterion). We evaluated SPP length, horizontal invasion length (HIL), and corneal profiles including keratometry, root mean square values for lower- and higher-order aberrations, and first- to fourth-order wavefront aberrations. Correlations between SPP length and these parameters were assessed after adjusting for HIL. The SPP cutoff for significant anterior horizontal tilt deterioration was determined using receiver operating characteristic (ROC) analysis and validated by analysis of covariance controlling for HIL.
Results:
SPP was detected in 57 of 72 eyes (79.2%), with a mean length of 842.3 ± 408.1 μm. A significant positive correlation was found between SPP length and HIL (r = 0.376, p = 0.001). After adjusting for HIL, SPP length remained significantly associated with anterior corneal horizontal tilt (p = 0.026), whereas no significant correlations were observed with other refractive or aberration parameters. ROC curve analysis identified an SPP length of approximately 850 μm as the threshold for predicting anterior horizontal tilt ≥3.65 μm. Consequently, this cutoff significantly differentiated subgroups after adjusting for HIL, showing a marked increase in horizontal tilt in eyes with SPP ≥850 μm (p = 0.016), indicating mechanical distortion.
Conclusions
SPP length, a subepithelial microstructural parameter visualized by AS SS-OCT, independently correlates with anterior horizontal tilt after adjustment for HIL. This finding suggests that SPP length serves as a microstructural indicator of horizontal mechanical corneal distortion in eyes with pterygium.
4.Identification of a Horizontal Invasion Length Threshold Predicting Posterior Corneal Flattening after Pterygium Excision
Junga OH ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2026;40(2):169-175
Purpose:
To characterize perioperative changes in posterior corneal curvature (PCC) following pterygium excision using anterior segment (AS) swept-source optical coherence tomography (SS-OCT), and to identify the critical threshold of horizontal invasion length (HIL) predicting significant PCC alterations.
Methods:
This retrospective cohort study included 85 eyes of 77 patients with primary nasal pterygium. PCC parameters, including posterior keratometry (K) average, posterior steep K, posterior flat K and posterior corneal astigmatism, were measured preoperatively and postoperatively using AS SS-OCT (Anterion). Perioperative PCC changes were analyzed in relation to HIL and postoperative duration. Subgroup analyses were performed to identify the HIL cutoff value associated with statistically significant changes in posterior K average.
Results:
Significant postoperative flattening was observed in both posterior K average (from –6.27 ± 0.24 to –6.23 ± 0.23 diopters [D], p < 0.001) and posterior flat K (from –6.14 ± 0.23 to –6.09 ± 0.23 D, p < 0.001), accompanied by a significant increase in posterior corneal astigmatism (from –0.25 ± 0.12 to –0.29 ± 0.17 D, p = 0.003). The magnitude of posterior flattening showed a significant positive correlation with HIL (r = 0.384, p < 0.001) but was not correlated with postoperative duration (p = 0.428). In subgroup analysis, eyes with HIL ≥3.5 mm exhibited a significant change in posterior K average (p < 0.001), whereas those with HIL <3.0 mm and HIL <3.5 mm showed no significant change (p = 0.065 and p = 0.443, respectively).
Conclusions
Pterygium excision leads to significant posterior corneal flattening proportional to HIL, with 3.5 mm identified as a clinically relevant cutoff. Although the refractive impact may be subtle, surgeons should be aware of these posterior corneal changes as a consistent morphological response, especially in eyes with HIL ≥3.5 mm.
5.Optimal Time for Stabilization of Anterior Corneal Keratometry after Primary Pterygium Excision Adjusted for Horizontal Invasion Length
Seunghwan KIM ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2026;40(2):133-140
Purpose:
To determine the corneal stabilization timeline after pterygium excision adjusted for horizontal invasion length (HIL).
Methods:
In this single-center retrospective cohort study, we analyzed 88 eyes of 80 patients with nasal or temporal primary pterygium who underwent excision and perioperative evaluation with anterior segment (AS) swept-source optical coherence tomography (SS-OCT; Anterion). Anterior simulated mean keratometry (SimKmean; 3-mm ring) and HIL were measured on AS SS-OCT. Keratometric stabilization was assessed at postoperative cutoffs of 8, 12, 16, 20, and 24 weeks using analysis of covariance (ANCOVA) with HIL as a covariate. Subgroup analysis was performed after stratifying by the median HIL (3.82 mm).
Results:
Mean anterior SimKmean increased from 42.95 ± 1.79 diopters (D) preoperatively to 43.73 ± 1.53 D postoperatively (p < 0.001). Preoperative HIL correlated positively with the perioperative SimKmean change (r = 0.728, p < 0.001). While postoperative duration showed no significant unadjusted correlation with keratometric change (r = −0.133, p = 0.218), partial correlation controlling for HIL was negative (r = −0.248, p = 0.021), indicating diminishing change over time after severity adjustment. ANCOVA demonstrated significant stabilization at 16 weeks (p = 0.036). In the HIL ≥3.82 mm subgroup, SimKmean change was greater before 20 weeks than after 20 weeks (1.73 ± 1.59 D vs. 0.59 ± 0.74 D, p = 0.030), whereas no significant time-point differences were found for HIL <3.82 mm.
Conclusions
Corneal keratometric stabilization after pterygium excision depends on preoperative HIL. A minimum of 16 weeks is recommended before cataract surgery planning, with at least 20 weeks for eyes with HIL ≥3.82 mm.
6.Association between Fibrovascular Translucency of Pterygium and Corneal Curvature and Aberrations after Adjustment for Horizontal Invasion Length
Dong Hee HA ; Seung Hyeun LEE ; Kyoung Woo KIM
Korean Journal of Ophthalmology 2026;40(1):45-52
Purpose:
This study aims to determine whether the translucency-based clinical grade of pterygium shows independent relationships with anterior and posterior corneal curvature and anterior wavefront aberrations, with adjustment for horizontal invasion length (HIL) measured by anterior segment (AS) swept-source optical coherence tomography (SS-OCT).
Methods:
This study involved 53 eyes from 51 patients diagnosed with primary nasal pterygium. The clinical grade of the pterygium was evaluated using T grade based on the fibrovascular translucency. AS SS-OCT (Anterion, Heidelberg Engineering) provided HIL (in millimeters), thickness (in micrometers), anterior/posterior keratometry at the 3.0-mm ring, and anterior corneal wavefront metrics within a 6.0-mm zone. The device was also used to evaluate the magnitudes for the individual first-to fourth-order aberrations of the anterior corneal fields. Also, the fourth- to seventh-order root mean square (RMS), RMS lower-order aberration (LoA), and RMS higher-order aberration (HoA) values were collected. For statistical analysis, Spearman rank correlation test and Pearson correlation test were performed, along with partial correlation test adjusted for HIL.
Results:
The mean age of subjects was 59.3 ± 11.4 years, and 51.0% were female. T grade correlated positively with HIL. HIL showed strong associations with anterior simulated keratometry (Sim K) average, anterior Sim K steep, anterior Sim K flat, and anterior corneal astigmatism—but not with posterior corneal parameters. HIL also showed significant correlations with multiple anterior corneal wavefront parameters. After adjustment for HIL, T grade remained independently correlated with anterior Sim K flat, RMS LoA, and defocus; no significant relationships were observed with other Zernike terms or posterior metrics. Additionally, T grade was positively correlated with pterygium thickness.
Conclusions
T grade adds independent, complementary information (associations with flat keratometry, LoA RMS, and defocus) even after controlling for HIL. Incorporating T grade into preoperative assessment may improve estimation of optical burden and surgical prognosis.
7.Cage design-centric glider approach to full-endoscopic lumbar fusion: optimizing nerve root protection in facet-sparing and facet-resecting techniques
Yu-Chia HSU ; Hao-Chun CHUANG ; Yuan-Fu LIU ; Chao-Jui CHANG ; Yu-Meng HSIAO ; Yi-Hung HUANG ; Keng-Chang LIU ; Chien-Min CHEN ; Hyeun-Sung KIM ; Cheng-Li LIN
Asian Spine Journal 2026;20(2):343-353
Endoscopic transforaminal lumbar interbody fusion (TLIF) offers substantial advantages in the management of degenerative spinal diseases, including accelerated postoperative recovery. However, its technical complexity and steep learning curve pose risks for nerve root injury. Optimizing nerve root protection in full-endoscopic facet-sparing TLIF (FE fs-TLIF) and full-endoscopic facet-resecting TLIF (FE fr-TLIF) is essential for enhancing surgical safety. This study aimed to improve the nerve root protection in FE fs-TLIF and FE fr-TLIF by optimizing cage glider selection and insertion techniques based on the specific cage shape—banana-shaped or bullet-shaped. The goal was to ensure safe cage positioning and mitigate nerve root injury during discectomy, endplate preparation, and cage insertion. These strategies were validated through cadaveric simulations and clinical implementation. In FE fr-TLIF utilizing bullet-shaped (straight) cages, one-tip and two-tip cage gliders effectively protected the traversing nerve root by facilitating medial cage entry, thereby minimizing irritation of the exiting nerve root. Conversely, in FE fr-TLIF with banana-shaped cages, the lateral tilt of the cage holder during implantation required the use of a two-tip cage glider to protect the traversing and exiting nerve roots, thereby mitigating the potential risk of nerve irritation. In FE fs-TLIF, a one-tip cage glider is preferred for safeguarding the exiting nerve root, while the traversing root is inherently protected by the medial wall of the facet joint. The use of a two-tip cage glider in FE fs-TLIF can cause injury to the nerve root during glider insertion. In addition to the selection of cage gliders, improper cage insertion steps can also contribute to postoperative neurapraxia. The appropriate selection of cage gliders with corresponding insertion techniques is critical for nerve root protection in endoscopic TLIF. Tailoring these choices to the specific approach (FE fs-TLIF or FE fr-TLIF) and cage type (banana or bullet) enhances surgical safety and clinical outcomes.
8.Exosomes from Human Embryonic Stem Cell-Derived Mesenchymal Stem Cells Protect Lung Epithelium and Attenuate Fibrosis
Sangryul CHA ; Jooyeon LEE ; Jimin JANG ; Yeongcheol KIM ; Dahee HAN ; Seok-Ho HONG ; Seung-Jin KIM ; Dae-Hee LEE ; Chung Hyeun MA ; Han Pil LEE ; Se-Ran YANG
International Journal of Stem Cells 2026;19(1):66-82
Idiopathic pulmonary fibrosis (IPF) is characterized by maladaptive epithelial–mesenchymal crosstalk and progressive extracellular matrix accumulation, whereas currently available antifibrotic agents merely decelerate functional decline.This study investigated whether exosomes derived from human mesenchymal stem cells derived from embryonic stem cells (ESC-MSCs) restore epithelial stress responses and attenuate fibrotic remodeling. Human IPF lung transcriptomes were integrated with a bleomycin-induced murine model analyzed by RNA sequencing and protein signaling, together with cigarette smoke extract-induced injury in A549 epithelial cells. ESC-MSCs-derived exosomes exhibited typical morphology and size distribution, enrichment of tetraspanins, and absence of endoplasmic reticulum contamination, consistent with high-purity preparations. Across human IPF and bleomycin-injured lungs, transcriptomic profiling revealed prominent enrichment of extracellular matrix and cytoskeletal gene programs, whereas mitogen-activated protein kinase (MAPK) and Smad families displayed only modest alterations at the mRNA level. In vivo administration of exosomes during the fibrotic remodeling phase, via either intravenous or intratracheal delivery, resulted in improved body weight, reduced lung weight-to-body weight ratios, and decreased collagen deposition and Ashcroft scores. These structural and functional improvements were accompanied by suppression of profibrotic and mesenchymal markers and selective attenuation of activator protein-1 (AP-1) activity. In epithelial injury models, ESC-MSCs-derived exosomes enhanced cell viability, restored redox homeostasis, and constrained stress-induced mesenchymal gene expression and MAPK phosphorylation in both co-treatment and post-treatment settings. Collectively, these data support an epithelial-centered mechanism in which ESC-MSCs-derived exosomes re-establish oxidative balance and selectively restrict AP-1-driven stress signaling, thereby secondarily limiting extracellular matrix accumulation and fibrotic remodeling.
9.Comparison of reference management software with new artificial intelligence-based tools
Jae Gyeong JIN ; Seung Gyu LEE ; Jea Hyeun PARK ; Jang Won HAN ; Jae Young KIM ; Jungirl SEOK ; Jeong-Ju YOO
Journal of Educational Evaluation for Health Professions 2026;23(1):2-
Reference management software (RMS) represents a cornerstone of modern academic writing and publishing. For decades, programs such as EndNote, Zotero, and Mendeley have played central roles in facilitating citation organization, bibliography formatting, and collaborative scholarship. Although each platform has introduced unique innovations, persistent limitations remain, particularly with respect to usability, accessibility, and accuracy. In parallel, the rise of generative artificial intelligence has introduced an unprecedented challenge: the inadvertent inclusion of fabricated or incorrect references mistakenly incorporated into manuscripts. This phenomenon has exposed a critical limitation of traditional RMS platforms, namely their inability to verify reference authenticity. Against this backdrop, new solutions have emerged. One such example is CiteWell (https://citewell.org/), an artificial intelligence (AI)-era RMS that introduces several notable innovations, including PubMed-integrated verification, an intuitive interface for new users, customizable journal-specific styles, and multilingual accessibility. This review provides a comprehensive historical overview of RMS, evaluates the strengths and weaknesses of major platforms, and positions emerging AI-based tools as a new paradigm that combines traditional reference management with essential safeguards for contemporary academic challenges.
10.ERRATUM: Imaging follow-up strategy after endovascular treatment of intracranial aneurysms: A literature review and guideline recommendations
Yong-Hwan CHO ; Jaehyung CHOI ; Chae-Wook HUH ; Chang Hyeun KIM ; Chul Hoon CHANG ; Soon Chan KWON ; Young Woo KIM ; Seung Hun SHEEN ; Sukh Que PARK ; Jun Kyeung KO ; Sung-kon HA ; Hae Woong JEONG ; Hyen Seung KANG ;
Journal of Cerebrovascular and Endovascular Neurosurgery 2025;27(1):80-80

Result Analysis
Print
Save
E-mail