1.Evaluating the Accuracy and Diagnostic Reasoning of Multimodal Large Language Models in Interpreting Neuroradiology Cases From RadioGraphics
Pae Sun SUH ; Ji Su KO ; Woo Hyun SHIM ; Hwon HEO ; Chang-Yun WOO ; Hyungjun PARK ; Chong Hyun SUH
Korean Journal of Radiology 2026;27(3):214-226
Objective:
To evaluate the accuracy and reasoning capabilities of large multimodal language models compared with those of neuroradiology subspecialty-trained radiologists in neuroradiology case interpretation.
Materials and Methods:
This experimental study used custom-made 401 radiologic quizzes derived from articles published in RadioGraphics covering neuroradiology and head and neck topics (October 2020 to February 2024). We prompted the GPT-4 Turbo with Vision (GPT-4V), GPT-4 Omni, Gemini Flash, and Claude models to provide the top three differential diagnoses with a rationale and describe examination characteristics such as imaging modality, sequence, use of contrast, image plane, and body part. The temperature was adjusted to 0 and 1 (T1). Two neuroradiologists answered the same questions.The accuracies of the large language models (LLMs) and the neuroradiologists were compared using generalized estimating equations. Three neuroradiologists assessed the rationale provided by the LLMs for their differential diagnoses using four-point scales, separately for specific lesion locations and imaging findings, and evaluated the presence of hallucinations and the overall acceptability of the responses.
Results:
Top-3 accuracy (i.e., correct answers present among top-3 differential diagnoses) of LLMs ranged from 29.9% (120 of 401) to 49.4% (198 of 401, obtained with GPT-4V in the T1 setting), while radiologists achieved 80.3% (322 of 401) and 68.3% (274 of 401), respectively (P < 0.001). Regarding the rationale for differential diagnoses, GPT-4V (T1) accurately identified both the specific lesion location and imaging findings in 30.7% (123 of 401) and 12.9% (16 of 124) of cases without textual clinical history. Hallucinations occurred in 4.5% (18 of 401), and only 29.4% (118 of 401) of the LLM-generated analyses were deemed acceptable. GPT-4V (T1) demonstrated high accuracy in identifying the imaging modality (97.4% [800 of 821]) and scanned body parts (92.2% [756 of 820]).
Conclusion
LLMs remarkably underperformed compared with neuroradiologists and showed unsatisfactory reasoning for their differential diagnoses, with performance declining further in cases without textual input of clinical history. These findings highlight the limitations of current multimodal LLMs in neuroradiological interpretation and their reliance on text input.
3.Adherence of Studies on Large Language Models for Medical Applications Published in Leading Medical Journals According to the MI-CLEAR-LLM Checklist
Ji Su KO ; Hwon HEO ; Chong Hyun SUH ; Jeho YI ; Woo Hyun SHIM
Korean Journal of Radiology 2025;26(4):304-312
Objective:
To evaluate the adherence of large language model (LLM)-based healthcare research to the Minimum Reporting Items for Clear Evaluation of Accuracy Reports of Large Language Models in Healthcare (MI-CLEAR-LLM) checklist, a framework designed to enhance the transparency and reproducibility of studies on the accuracy of LLMs for medical applications.
Materials and Methods:
A systematic PubMed search was conducted to identify articles on LLM performance published in high-ranking clinical medicine journals (the top 10% in each of the 59 specialties according to the 2023 Journal Impact Factor) from November 30, 2022, through June 25, 2024. Data on the six MI-CLEAR-LLM checklist items: 1) identification and specification of the LLM used, 2) stochasticity handling, 3) prompt wording and syntax, 4) prompt structuring, 5) prompt testing and optimization, and 6) independence of the test data—were independently extracted by two reviewers, and adherence was calculated for each item.
Results:
Of 159 studies, 100% (159/159) reported the name of the LLM, 96.9% (154/159) reported the version, and 91.8% (146/159) reported the manufacturer. However, only 54.1% (86/159) reported the training data cutoff date, 6.3% (10/159) documented access to web-based information, and 50.9% (81/159) provided the date of the query attempts. Clear documentation regarding stochasticity management was provided in 15.1% (24/159) of the studies. Regarding prompt details, 49.1% (78/159) provided exact prompt wording and syntax but only 34.0% (54/159) documented prompt-structuring practices. While 46.5% (74/159) of the studies detailed prompt testing, only 15.7% (25/159) explained the rationale for specific word choices. Test data independence was reported for only 13.2% (21/159) of the studies, and 56.6% (43/76) provided URLs for internet-sourced test data.
Conclusion
Although basic LLM identification details were relatively well reported, other key aspects, including stochasticity, prompts, and test data, were frequently underreported. Enhancing adherence to the MI-CLEAR-LLM checklist will allow LLM research to achieve greater transparency and will foster more credible and reliable future studies.
4.Adherence of Studies on Large Language Models for Medical Applications Published in Leading Medical Journals According to the MI-CLEAR-LLM Checklist
Ji Su KO ; Hwon HEO ; Chong Hyun SUH ; Jeho YI ; Woo Hyun SHIM
Korean Journal of Radiology 2025;26(4):304-312
Objective:
To evaluate the adherence of large language model (LLM)-based healthcare research to the Minimum Reporting Items for Clear Evaluation of Accuracy Reports of Large Language Models in Healthcare (MI-CLEAR-LLM) checklist, a framework designed to enhance the transparency and reproducibility of studies on the accuracy of LLMs for medical applications.
Materials and Methods:
A systematic PubMed search was conducted to identify articles on LLM performance published in high-ranking clinical medicine journals (the top 10% in each of the 59 specialties according to the 2023 Journal Impact Factor) from November 30, 2022, through June 25, 2024. Data on the six MI-CLEAR-LLM checklist items: 1) identification and specification of the LLM used, 2) stochasticity handling, 3) prompt wording and syntax, 4) prompt structuring, 5) prompt testing and optimization, and 6) independence of the test data—were independently extracted by two reviewers, and adherence was calculated for each item.
Results:
Of 159 studies, 100% (159/159) reported the name of the LLM, 96.9% (154/159) reported the version, and 91.8% (146/159) reported the manufacturer. However, only 54.1% (86/159) reported the training data cutoff date, 6.3% (10/159) documented access to web-based information, and 50.9% (81/159) provided the date of the query attempts. Clear documentation regarding stochasticity management was provided in 15.1% (24/159) of the studies. Regarding prompt details, 49.1% (78/159) provided exact prompt wording and syntax but only 34.0% (54/159) documented prompt-structuring practices. While 46.5% (74/159) of the studies detailed prompt testing, only 15.7% (25/159) explained the rationale for specific word choices. Test data independence was reported for only 13.2% (21/159) of the studies, and 56.6% (43/76) provided URLs for internet-sourced test data.
Conclusion
Although basic LLM identification details were relatively well reported, other key aspects, including stochasticity, prompts, and test data, were frequently underreported. Enhancing adherence to the MI-CLEAR-LLM checklist will allow LLM research to achieve greater transparency and will foster more credible and reliable future studies.
5.Adherence of Studies on Large Language Models for Medical Applications Published in Leading Medical Journals According to the MI-CLEAR-LLM Checklist
Ji Su KO ; Hwon HEO ; Chong Hyun SUH ; Jeho YI ; Woo Hyun SHIM
Korean Journal of Radiology 2025;26(4):304-312
Objective:
To evaluate the adherence of large language model (LLM)-based healthcare research to the Minimum Reporting Items for Clear Evaluation of Accuracy Reports of Large Language Models in Healthcare (MI-CLEAR-LLM) checklist, a framework designed to enhance the transparency and reproducibility of studies on the accuracy of LLMs for medical applications.
Materials and Methods:
A systematic PubMed search was conducted to identify articles on LLM performance published in high-ranking clinical medicine journals (the top 10% in each of the 59 specialties according to the 2023 Journal Impact Factor) from November 30, 2022, through June 25, 2024. Data on the six MI-CLEAR-LLM checklist items: 1) identification and specification of the LLM used, 2) stochasticity handling, 3) prompt wording and syntax, 4) prompt structuring, 5) prompt testing and optimization, and 6) independence of the test data—were independently extracted by two reviewers, and adherence was calculated for each item.
Results:
Of 159 studies, 100% (159/159) reported the name of the LLM, 96.9% (154/159) reported the version, and 91.8% (146/159) reported the manufacturer. However, only 54.1% (86/159) reported the training data cutoff date, 6.3% (10/159) documented access to web-based information, and 50.9% (81/159) provided the date of the query attempts. Clear documentation regarding stochasticity management was provided in 15.1% (24/159) of the studies. Regarding prompt details, 49.1% (78/159) provided exact prompt wording and syntax but only 34.0% (54/159) documented prompt-structuring practices. While 46.5% (74/159) of the studies detailed prompt testing, only 15.7% (25/159) explained the rationale for specific word choices. Test data independence was reported for only 13.2% (21/159) of the studies, and 56.6% (43/76) provided URLs for internet-sourced test data.
Conclusion
Although basic LLM identification details were relatively well reported, other key aspects, including stochasticity, prompts, and test data, were frequently underreported. Enhancing adherence to the MI-CLEAR-LLM checklist will allow LLM research to achieve greater transparency and will foster more credible and reliable future studies.
6.Adherence of Studies on Large Language Models for Medical Applications Published in Leading Medical Journals According to the MI-CLEAR-LLM Checklist
Ji Su KO ; Hwon HEO ; Chong Hyun SUH ; Jeho YI ; Woo Hyun SHIM
Korean Journal of Radiology 2025;26(4):304-312
Objective:
To evaluate the adherence of large language model (LLM)-based healthcare research to the Minimum Reporting Items for Clear Evaluation of Accuracy Reports of Large Language Models in Healthcare (MI-CLEAR-LLM) checklist, a framework designed to enhance the transparency and reproducibility of studies on the accuracy of LLMs for medical applications.
Materials and Methods:
A systematic PubMed search was conducted to identify articles on LLM performance published in high-ranking clinical medicine journals (the top 10% in each of the 59 specialties according to the 2023 Journal Impact Factor) from November 30, 2022, through June 25, 2024. Data on the six MI-CLEAR-LLM checklist items: 1) identification and specification of the LLM used, 2) stochasticity handling, 3) prompt wording and syntax, 4) prompt structuring, 5) prompt testing and optimization, and 6) independence of the test data—were independently extracted by two reviewers, and adherence was calculated for each item.
Results:
Of 159 studies, 100% (159/159) reported the name of the LLM, 96.9% (154/159) reported the version, and 91.8% (146/159) reported the manufacturer. However, only 54.1% (86/159) reported the training data cutoff date, 6.3% (10/159) documented access to web-based information, and 50.9% (81/159) provided the date of the query attempts. Clear documentation regarding stochasticity management was provided in 15.1% (24/159) of the studies. Regarding prompt details, 49.1% (78/159) provided exact prompt wording and syntax but only 34.0% (54/159) documented prompt-structuring practices. While 46.5% (74/159) of the studies detailed prompt testing, only 15.7% (25/159) explained the rationale for specific word choices. Test data independence was reported for only 13.2% (21/159) of the studies, and 56.6% (43/76) provided URLs for internet-sourced test data.
Conclusion
Although basic LLM identification details were relatively well reported, other key aspects, including stochasticity, prompts, and test data, were frequently underreported. Enhancing adherence to the MI-CLEAR-LLM checklist will allow LLM research to achieve greater transparency and will foster more credible and reliable future studies.
7.Adherence of Studies on Large Language Models for Medical Applications Published in Leading Medical Journals According to the MI-CLEAR-LLM Checklist
Ji Su KO ; Hwon HEO ; Chong Hyun SUH ; Jeho YI ; Woo Hyun SHIM
Korean Journal of Radiology 2025;26(4):304-312
Objective:
To evaluate the adherence of large language model (LLM)-based healthcare research to the Minimum Reporting Items for Clear Evaluation of Accuracy Reports of Large Language Models in Healthcare (MI-CLEAR-LLM) checklist, a framework designed to enhance the transparency and reproducibility of studies on the accuracy of LLMs for medical applications.
Materials and Methods:
A systematic PubMed search was conducted to identify articles on LLM performance published in high-ranking clinical medicine journals (the top 10% in each of the 59 specialties according to the 2023 Journal Impact Factor) from November 30, 2022, through June 25, 2024. Data on the six MI-CLEAR-LLM checklist items: 1) identification and specification of the LLM used, 2) stochasticity handling, 3) prompt wording and syntax, 4) prompt structuring, 5) prompt testing and optimization, and 6) independence of the test data—were independently extracted by two reviewers, and adherence was calculated for each item.
Results:
Of 159 studies, 100% (159/159) reported the name of the LLM, 96.9% (154/159) reported the version, and 91.8% (146/159) reported the manufacturer. However, only 54.1% (86/159) reported the training data cutoff date, 6.3% (10/159) documented access to web-based information, and 50.9% (81/159) provided the date of the query attempts. Clear documentation regarding stochasticity management was provided in 15.1% (24/159) of the studies. Regarding prompt details, 49.1% (78/159) provided exact prompt wording and syntax but only 34.0% (54/159) documented prompt-structuring practices. While 46.5% (74/159) of the studies detailed prompt testing, only 15.7% (25/159) explained the rationale for specific word choices. Test data independence was reported for only 13.2% (21/159) of the studies, and 56.6% (43/76) provided URLs for internet-sourced test data.
Conclusion
Although basic LLM identification details were relatively well reported, other key aspects, including stochasticity, prompts, and test data, were frequently underreported. Enhancing adherence to the MI-CLEAR-LLM checklist will allow LLM research to achieve greater transparency and will foster more credible and reliable future studies.
8.Comparative Performance of Susceptibility Map-Weighted MRI According to the Acquisition Planes in the Diagnosis of Neurodegenerative Parkinsonism
Suiji LEE ; Chong Hyun SUH ; Sungyang JO ; Sun Ju CHUNG ; Hwon HEO ; Woo Hyun SHIM ; Jongho LEE ; Ho Sung KIM ; Sang Joon KIM ; Eung Yeop KIM
Korean Journal of Radiology 2024;25(3):267-276
Objective:
To evaluate the diagnostic performance of susceptibility map-weighted imaging (SMwI) taken in different acquisition planes for discriminating patients with neurodegenerative parkinsonism from those without.
Materials and Methods:
This retrospective, observational, single-institution study enrolled consecutive patients who visited movement disorder clinics and underwent brain MRI and 18F-FP-CIT PET between September 2021 and December 2021. SMwI images were acquired in both the oblique (perpendicular to the midbrain) and the anterior commissure-posterior commissure (AC-PC) planes. Hyperintensity in the substantia nigra was determined by two neuroradiologists. 18F-FP-CIT PET was used as the reference standard. Inter-rater agreement was assessed using Cohen’s kappa coefficient. The diagnostic performance of SMwI in the two planes was analyzed separately for the right and left substantia nigra. Multivariable logistic regression analysis with generalized estimating equations was applied to compare the diagnostic performance of the two planes.
Results:
In total, 194 patients were included, of whom 105 and 103 had positive results on 18F-FP-CIT PET in the left and right substantia nigra, respectively. Good inter-rater agreement in the oblique (κ = 0.772/0.658 for left/right) and AC-PC planes (0.730/0.741 for left/right) was confirmed. The pooled sensitivities for two readers were 86.4% (178/206, left) and 83.3% (175/210, right) in the oblique plane and 87.4% (180/206, left) and 87.6% (184/210, right) in the AC-PC plane. The pooled specificities for two readers were 83.5% (152/182, left) and 82.0% (146/178, right) in the oblique plane, and 83.5% (152/182, left) and 86.0% (153/178, right) in the AC-PC plane. There were no significant differences in the diagnostic performance between the two planes (P > 0.05).
Conclusion
There are no significant difference in the diagnostic performance of SMwI performed in the oblique and AC-PC plane in discriminating patients with parkinsonism from those without. This finding affirms that each institution may choose the imaging plane for SMwI according to their clinical settings.

Result Analysis
Print
Save