1.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
2.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
3.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
4.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.
5.Pericapsular Nerve Group Block with Periarticular Injection for Pain Management after Total Hip Arthroplasty: A Randomized Controlled Trial
Hun Sik CHO ; Bo Ra LEE ; Hyuck Min KWON ; Jun Young PARK ; Hyeong Won HAM ; Woo-Suk LEE ; Kwan Kyu PARK ; Tae Sung LEE ; Yong Seon CHOI
Yonsei Medical Journal 2025;66(4):233-239
Purpose:
The purpose of this study was to compare the effectiveness of pericapsular nerve group (PENG) block with periarticular multimodal drug injection (PMDI) on postoperative pain management and surgical outcomes in patients who underwent total hip arthroplasty (THA). We hypothesized that PENG block with PMDI would exhibit superior effects on postoperative pain control after THA compared to PMDI alone.
Materials and Methods:
From April 2022 to February 2023, 58 patients who underwent THA were randomly assigned into two groups: PENG block with PMDI group (n=29) and PMDI-only group (n=29). Primary outcomes were postoperative numeric rating scale (NRS) at rest and during activity at 6, 24, and 48 hours postoperatively. Secondary outcomes were postoperative complications (nausea and vomiting), Richards-Campbell Sleep Questionnaire (RCSQ) score, length of hospital stay, Western Ontario and McMaster Universities Osteoarthritis (WOMAC) index, Harris Hip Score (HHS), and total morphine usage after surgery.
Results:
There was no significant difference in postoperative pain for either resting NRS or active NRS. Postoperative nausea and vomiting, RCSQ score, length of hospital stay, WOMAC index, HHS, and total morphine usage exhibited no significant differences between the two groups.
Conclusion
Both groups showed no significant differences in postoperative pain and clinical outcomes, indicating that the addition of PENG block to PMDI does not improve pain management after applying the posterolateral approach of THA. PMDI alone during THA would be an efficient, fast, and safe method for managing postoperative pain. This article was registered with ClinicalTrials.gov (Gov ID: NCT05320913).
6.Influence of Patellar Implant Shape on Patellofemoral Contact Pressure Using Finite Element Analysis
Hun Sik CHO ; Hyoung-Taek HONG ; Hyuck Min KWON ; Yong-Gon KOH ; Seong-Mun HWANG ; Kwan Kyu PARK ; Kyoung-Tak KANG
Yonsei Medical Journal 2025;66(6):383-389
Purpose:
This study focused on analyzing the contact pressure and area on different patellar component designs in total knee arthroplasty (TKA) to evaluate biomechanics related to the patellofemoral (PF) joint.
Materials and Methods:
The patellar components studied included the dome design, modified dome design, and anatomical design implants. Using finite element analysis and mechanical testing, the pressure and area were evaluated. The first loading condition was simulated at flexion angles of 0°, 15°, 45°, 90°, 120°, and 150°. The second loading condition was simulated for a clinically relevant scenario, involving a 2-mm medial shift at a flexion angle of 45°.
Results:
For both the modified dome and anatomical designs, the contact area and pressure increased with the flexion angle. The dome design reached its maximum contact area at a flexion angle of 120°. Among the designs, the anatomical design had the largest contact area and a lower contact pressure compared to the dome and modified dome designs. However, when a medial shift of 2 mm was simulated at a 45° flexion angle, which can occur clinically, the anatomical design showed edge contact, leading to higher contact pressure and reduced contact area. In contrast, the modified dome design demonstrated the lowest contact pressure and the greatest contact area under the same shifted conditions.
Conclusion
These findings suggest that the design of the patellar component significantly affects patellar biomechanics and stability. Specifically, the modified dome design showed improved biomechanical effects in clinically relevant scenarios. Therefore, patellar components with a modified dome design are expected to better manage PF joint pain and reduce complications in TKA.
7.Erratum: Korean Gastric Cancer Association-Led Nationwide Survey on Surgically Treated Gastric Cancers in 2023
Dong Jin KIM ; Jeong Ho SONG ; Ji-Hyeon PARK ; Sojung KIM ; Sin Hye PARK ; Cheol Min SHIN ; Yoonjin KWAK ; Kyunghye BANG ; Chung-sik GONG ; Sung Eun OH ; Yoo Min KIM ; Young Suk PARK ; Jeesun KIM ; Ji Eun JUNG ; Mi Ran JUNG ; Bang Wool EOM ; Ki Bum PARK ; Jae Hun CHUNG ; Sang-Il LEE ; Young-Gil SON ; Dae Hoon KIM ; Sang Hyuk SEO ; Sejin LEE ; Won Jun SEO ; Dong Jin PARK ; Yoonhong KIM ; Jin-Jo KIM ; Ki Bum PARK ; In CHO ; Hye Seong AHN ; Sung Jin OH ; Ju-Hee LEE ; Hayemin LEE ; Seong Chan GONG ; Changin CHOI ; Ji-Ho PARK ; Eun Young KIM ; Chang Min LEE ; Jong Hyuk YUN ; Seung Jong OH ; Eunju LEE ; Seong-A JEONG ; Jung-Min BAE ; Jae-Seok MIN ; Hyun-dong CHAE ; Sung Gon KIM ; Daegeun PARK ; Dong Baek KANG ; Hogoon KIM ; Seung Soo LEE ; Sung Il CHOI ; Seong Ho HWANG ; Su-Mi KIM ; Moon Soo LEE ; Sang Hyun KIM ; Sang-Ho JEONG ; Yusung YANG ; Yonghae BAIK ; Sang Soo EOM ; Inho JEONG ; Yoon Ju JUNG ; Jong-Min PARK ; Jin Won LEE ; Jungjai PARK ; Ki Han KIM ; Kyung-Goo LEE ; Jeongyeon LEE ; Seongil OH ; Ji Hun PARK ; Jong Won KIM ;
Journal of Gastric Cancer 2025;25(2):400-402
8.Korean Gastric Cancer AssociationLed Nationwide Survey on Surgically Treated Gastric Cancers in 2023
Dong Jin KIM ; Jeong Ho SONG ; Ji-Hyeon PARK ; Sojung KIM ; Sin Hye PARK ; Cheol Min SHIN ; Yoonjin KWAK ; Kyunghye BANG ; Chung-sik GONG ; Sung Eun OH ; Yoo Min KIM ; Young Suk PARK ; Jeesun KIM ; Ji Eun JUNG ; Mi Ran JUNG ; Bang Wool EOM ; Ki Bum PARK ; Jae Hun CHUNG ; Sang-Il LEE ; Young-Gil SON ; Dae Hoon KIM ; Sang Hyuk SEO ; Sejin LEE ; Won Jun SEO ; Dong Jin PARK ; Yoonhong KIM ; Jin-Jo KIM ; Ki Bum PARK ; In CHO ; Hye Seong AHN ; Sung Jin OH ; Ju-Hee LEE ; Hayemin LEE ; Seong Chan GONG ; Changin CHOI ; Ji-Ho PARK ; Eun Young KIM ; Chang Min LEE ; Jong Hyuk YUN ; Seung Jong OH ; Eunju LEE ; Seong-A JEONG ; Jung-Min BAE ; Jae-Seok MIN ; Hyun-dong CHAE ; Sung Gon KIM ; Daegeun PARK ; Dong Baek KANG ; Hogoon KIM ; Seung Soo LEE ; Sung Il CHOI ; Seong Ho HWANG ; Su-Mi KIM ; Moon Soo LEE ; Sang Hyun KIM ; Sang-Ho JEONG ; Yusung YANG ; Yonghae BAIK ; Sang Soo EOM ; Inho JEONG ; Yoon Ju JUNG ; Jong-Min PARK ; Jin Won LEE ; Jungjai PARK ; Ki Han KIM ; Kyung-Goo LEE ; Jeongyeon LEE ; Seongil OH ; Ji Hun PARK ; Jong Won KIM ; The Information Committee of the Korean Gastric Cancer Association
Journal of Gastric Cancer 2025;25(1):115-132
Purpose:
Since 1995, the Korean Gastric Cancer Association (KGCA) has been periodically conducting nationwide surveys on patients with surgically treated gastric cancer. This study details the results of the survey conducted in 2023.
Materials and Methods:
The survey was conducted from March to December 2024 using a standardized case report form. Data were collected on 86 items, including patient demographics, tumor characteristics, surgical procedures, and surgical outcomes. The results of the 2023 survey were compared with those of previous surveys.
Results:
Data from 12,751 cases were collected from 66 institutions. The mean patient age was 64.6 years, and the proportion of patients aged ≥71 years increased from 9.1% in 1995 to 31.7% in 2023. The proportion of upper-third tumors slightly decreased to 16.8% compared to 20.9% in 2019. Early gastric cancer accounted for 63.1% of cases in 2023.Regarding operative procedures, a totally laparoscopic approach was most frequently applied (63.2%) in 2023, while robotic gastrectomy steadily increased to 9.5% from 2.1% in 2014.The most common anastomotic method was the Billroth II procedure (48.8%) after distal gastrectomy and double-tract reconstruction (51.9%) after proximal gastrectomy in 2023.However, the proportion of esophago-gastrostomy with anti-reflux procedures increased to 30.9%. The rates of post-operative mortality and overall complications were 1.0% and 15.3%, respectively.
Conclusions
The results of the 2023 nationwide survey demonstrate the current status of gastric cancer treatment in Korea. This information will provide a basis for future gastric cancer research.
9.Prevalence and characteristics of impacted teeth in Korean orthodontic patients at ten university dental hospitals
Youn-Kyung CHOI ; Sung-Hun KIM ; Yong-Il KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Dong-Soon CHOI ; Ho-Jin KIM ; Kyung-A KIM ; Mo-Hyeon LEE ; Sung-Hwan CHOI ; Sung-Kwon CHOI ; Kyungmin Clara LEE ; Young-Mi JEON ; Sewoong OH ; Seorin JEONG
The Korean Journal of Orthodontics 2025;55(3):234-241
Objective:
This study aimed to investigate the prevalence and characteristics of impacted teeth (ITs) in orthodontic patients at university dental hospitals in Korea.
Methods:
This study included 14,774 patients who visited the Department of Orthodontics at 10 university dental hospitals in Korea between 2020 and 2022 and underwent orthodontic diagnosis. The prevalence and characteristics of ITs were investigated using orthodontic diagnostic records, radiographs, and diagnostic casts.
Results:
The prevalence of ITs, excluding third molar impaction, in Korean orthodontic patients was 13.6% (n = 2,014).The prevalence of ITs in pediatric orthodontic patients was 24.5% (n = 1,614).Of these patients, 68.2% had one IT, 27.5% had two ITs, 24.3% had bilateral IT, and 75.7% had unilateral IT. The most frequent IT was the maxillary canine (50.1%), followed by the mandibular second molar (11.7%), and maxillary second premolar (9.6%). An abnormal eruption path (46.5%) was the most frequent etiology. Orthodontic traction after surgical exposure (70.6%) was the most frequent treatment option. Among the patients with ITs, 29.8% had other dental anomalies, such as tooth agenesis (8.7%), microdontia (8.0%), and supernumerary teeth (5.1%). Furthermore, 50.8% had complications such as cystic lesions (18.3%), transposition (17.7%), and root resorption (14.8%).Among the patients with maxillary canine impaction, 62.2% had labial maxillary canine impaction and 21.1% had palatal maxillary canine impaction.
Conclusions
The prevalence of ITs in Korean orthodontic patients at university dental hospitals was high, particularly in pediatric orthodontic patients.
10.Force and moment analysis of clear aligners: Impact of material properties and design on premolar rotation
Dong-Woo KIM ; Hyun-Jun LEE ; Ki Beom KIM ; Sung-Hun KIM ; Seong-Sik KIM ; Soo-Byung PARK ; Youn-Kyung CHOI ; Yong-Il KIM
The Korean Journal of Orthodontics 2025;55(3):212-223
Objective:
To quantitatively analyze and compare the forces and moments generated by thermoformed polyethylene terephthalate glycol (PETG) and direct-printed TC-85 clear aligners (CAs), with various margin designs, during premolar rotation.
Methods:
In total, 132 CAs were fabricated and divided into four groups (n = 33 per group). Group C consisted of thermoformed PETG aligners with a 2 mm gingival margin. Group E comprised direct-printed TC-85 aligners with equi-gingival margin, whereas Group G utilized direct-printed TC-85 aligners with 2 mm gingival margins.Finally, Group T featured direct-printed TC-85 aligners with an additional 1 mm thickness at the mesial embrasure. The forces and moments were measured using a 6-axis force/moment transducer at 2°, 3°, and 4° of rotation. All measurements were conducted at 37°C to simulate intraoral conditions. Forces were measured in the buccolingual, anteroposterior, and vertical directions, while moments were measured in the mesiodistal, buccolingual, and rotational planes.
Results:
The PETG aligners (Group C) showed significantly increased buccal and posterior force across the rotation angles (P < 0.05), whereas the intrusive force remained consistent. In contrast, the TC-85 aligners maintained consistent forces across all rotation angles.Direct-printed aligners demonstrated significantly lower intrusive forces than PETG aligners (P < 0.001). Group T exhibited reduced unwanted forces while maintaining effective rotational moments. Furthermore, all direct-printed aligners showed more predictable force delivery patterns than thermoformed aligners.
Conclusions
Direct-printed TC-85 aligners demonstrated superior force consistency and reduced unwanted side effects compared with traditional PETG aligners. Although marginal design modifications did not significantly improve rotational efficiency, they effectively reduced unwanted intrusive forces.

Result Analysis
Print
Save
E-mail