1.Consensus on low-altitude transport and delivery services for emergency medicines via drones (2025 edition)
Qinshui WU ; Yanfang CHEN ; Tao LIU ; Xiaoyan LI ; Yumin LIANG ; Xin LI ; Zhong LI ; Rong LI ; Xiaoman WANG ; Shuyao ZHANG ; Huishu TIAN
China Pharmacy 2025;36(18):2221-2225
OBJECTIVE To promote the application of drones in emergency rescue and related fields, expand “low-altitude+ medical” rescue services, and advance the standardization of “low-altitude+medical” distribution services. METHODS The Consensus on Low-altitude Transport and Delivery Services for Emergency Medicines via Drones (2025 Edition) (hereinafter referred to as the Consensus) was jointly initiated by the Division of Therapeutic Drug Monitoring, Chinese Pharmacological Society and the Expert Committee on Precision Medication of the Guangdong Pharmaceutical Association. Guangzhou Red Cross Hospital served as the leading unit, organizing 53 multidisciplinary experts nationwide to participate in drafting and reviewing. A nominal group technique was employed to discuss and finalize the consensus outline, resulting in a preliminary draft. Delphi method was employed, and 11 external review experts were invited to conduct the evaluation. After the experts’ opinions were analyzed and integrated, the Consensus was finalized. RESULTS & CONCLUSIONS The finalized Consensus includes its purpose, principles, and applicable scenarios, basic requirements, and operational procedures for low-altitude transport and delivery of emergency medications; distribution requirements and precautions for controlled substances, fragile medications, and temperature-sensitive medications; and recommendations for emergency medications supplies suitable for the low-altitude transportation and distribution. The release of this Consensus is expected to provide guidance and support for the standardization of “low-altitude+medical” distribution services and the application of low-altitude economy in the healthcare sector.
2.A survey report on the status of emergency radiology in China
Jing WANG ; Zheng MIAO ; Qi YANG ; Lei ZHANG ; Hao WANG ; Huishu YUAN ; Haoran SUN ; Wei JIANG ; Yuan TIAN ; Mingyang LI ; Yaning WANG ; Zhaoyi MA ; Huimao ZHANG
Chinese Journal of Radiology 2024;58(6):661-666
Objective:To investigate the application status of emergency radiology in China, and to provide data support for the standardized development, scientific management and big data research of emergency radiology.Methods:From August 12th to October 19th, 2022, a questionnaire survey was conducted through WeChat"Questionnaire Star"to send targeted questionnaires to investigate the relevant data of the current status of emergency radiology in China, mainly including digital radiography (DR) and computed tomography (CT). This study was initiated by the Chinese Emergency Radiology Database Collaboration Group, and comprehensively investigated emergency imaging personnel, equipment, workload, critical value reporting process, and artificial intelligence (AI) application status.Results:There were 123 hospitals in the study. The survey showed that emergency DR/CT reports were mainly completed by residents and above (69.1%). There were 21 DR brands, 10 CT brands and 8 MR brands used for emergency imaging examinations. The median number of DR examinations in tertiary hospitals and secondary hospitals investigated from January to June 2022 was 4 642 and 2 015 cases respectively, and the median number of CT examinations was 16 512 and 3 762 cases respectively. The average single-shift workload of DR in the emergency radiology department during the day and night shift in tertiary hospitals was mainly ≤20 copies and 21-50 copies, and the average single-shift workload of CT in the emergency radiology department during the day and night shift was mainly 21-50 copies and 51-100 copies, while the average single-shift workload of DR/CT in the emergency radiology department during the day/night shift in secondary hospitals was mainly ≤20 copies. In terms of critical value reporting process, 74.8% of emergency imaging doctors and 84.6% of emergency imaging technicians took the way of phone/text message to notify the clinical doctor or the patients′ family. The overall deployment rate of AI in emergency imaging was about 60.2%. 75% of the respondents believed that in the future, AI can improve emergency radiology work from aspects such as emergency screening, aided diagnosis and process optimization.Conclusions:The emergency medical imaging mainly based on DR and CT has the current situations such as generally low seniority of doctors, diverse brands of imaging equipments, large volume of examinations and intense workload per doctor, especially in tertiary hospitals, and dependence on traditional means for critical value reporting. At present, AI is emerging in the field of emergency imaging, and there is still a long way to go to play the huge potential of AI in the intelligent whole process of emergency imaging in the future.
3.Efficacy and dosimetry of computed tomography image-guided 125 I radioactive seed implantation for locally recurrent rectal cancer
Hao WANG ; Junjie WANG ; Huishu YUAN ; Yuliang JIANG ; Suqing TIAN ; Chen LIU ; Jinna LI ; Ruijie YANG ; Haitao SUN
Chinese Journal of Radiation Oncology 2016;25(10):1096-1099
Objective To evaluate the efficacy of computed tomography ( CT ) image?guided 125 I radioactive seed implantation for locally recurrent rectal cancer ( LRRC ) , and to analyze the relationship between the dosimetry and prognosis. Methods A retrospective analysis was performed on the clinical data of 36 patients with LRRC who received CT image?guided 125 I seed implantation in our hospital from 2003 to 2011. Dosimetric verification was performed using CT scan immediately after 125 I seed implantation. The D90 , D100 , V100 , and V150 values were evaluated. In all the patients, the median activity of seeds was 0?7 mCi (0?4?0?8 mCi) and the median number of implanted seeds was 74(33?137). The local control (LC) and overall survival ( OS ) rates were calculated using the Kaplan?Meier method. The log?rank test and Cox regression model were used for the univariate and multivariate analyses, respectively. Results The median OS time was 16?2 months ( 95% CI= 13?5?18?9 months ) . The median LC time was 10?0 months (95% CI=6?2?13?8 months). The D90 and V100 values were (118.6±25?1) Gy and (90.0±0?3)%, respectively. The univariate analysis suggested that D90 was correlated with the LC time ( P=0?048) and V100 was correlated with the OS time ( P=0?035) . The multivariate analysis showed that a V100 value higher than 90% was a prognostic factor of OS (P=0?044). Conclusions In the treatment of LRRC using CT image?guided 125 I radioactive seed implantation, a D90 value larger than 140 Gy and a V100 value higher than 90% in the postoperative verification plan help improve the LC and OS rates. The D90 and V100 values in the postoperative verification plan may predict treatment outcomes in patients.
4.The neuro image study on the brain cortex in schizophrenic patients and their unaffected parents
Lanlan ZHANG ; Hao YAN ; Lin TIAN ; Wei SUN ; Fengmei FAN ; Xinian ZUO ; Qiang ZHAO ; Huishu YUAN ; Dai ZHANG
Chinese Journal of Nervous and Mental Diseases 2014;(3):157-161
Objective To investigate the morphological abnormalities of the brain cortex in schizophrenic patients and their parents. Methods We recruited 33 schizophrenic patients, 63 their unaffected biological parents. Thirty well matched healthy controls served as control group 1 (for patients), and 28 well matched healthy controls as control group 2 (for parents). The high-resolution magnetic resonance imaging (MRI) and Freesurfer software were used to measure the gray matter volume, cortical thickness, cortical surface area, curvature and volume of subcortical regions on all the sub-jects. Results The patients demonstrated significant reduction of cortical thickness in the left middle-anterior cingulate, middle occipital gyrus, inferior circular sulcus of the insula, lateral occipito-temporal sulcus, the right lateral occipito-temporal gyrus, middle temporal gyrus, superior circular sulcus of the insula, inferior temporal sulcus, the bilateral poste-rior-dorsalcingulated gyrus and superior temporal sulcus (P<6.0×10-4,corrected by Bonferroni method). Compared with control group 2, the unaffected parents exhibited slight reduction of cortical in the left subcentral, triangular part of the in-ferior frontal gyrus, middle frontal gyrus, superior circular sulcus of the insula, occipital pole, inferior frontal sulcus, mid-dle occipital sulcus and lunatus sulcus, lateral orbital sulcus, the right middle occipital gyrus, lingual gyrus, posterior lat- eral sulcus and inferior precentral sulcus, but the reduction was not significant after correction for multiple comparisons. Conclusions Our results indicate that cortical thickness can specifically reflect the brain morphological abnormalities of schizophrenia and the reduction of cortical thicknes may be a heritable phenotype of schizophrenia.
5.CT-guided 125I radioactive seed implantation for locally recurrent rectal cancer
Fumei YI ; Hao WANG ; Huishu YUAN ; Jinna LI ; Yuliang JIANG ; Suqing TIAN ; Junjie WANG
Chinese Journal of Radiological Medicine and Protection 2014;34(1):30-33
Objective To evaluate the efficacy and adverse reactions of CT-guided 125I radioactive seed implantation in treatment of locally recurrent rectal cancer (LRRC).Methods Thirty patients with LRRC who refused operation or were unable to endure pelvic radiotherapy received 125I seed implantation under CT guidance.Three-dimensional treatment planning system was used to calculate the number,activity,and dose of the seeds needed.The activity of seeds ranged from 14.8 to 29.6 MBq with a median of 25.9 MBq,the seed numbers ranged from 33 to 137 with a median of 74.5,the prescription doses ranged from120-160 Gy,and the actual verification dose D90 ranged from 75.91 to 159.32 Gy with a median of 119.77 Gy.Dosimetric verification by CT scanning was conducted immediately after the treatment.Follow-up was conducted for 15.2 months(4.2-35.0 months).Results The follow-up rate was 93.3%.The pain relief rate was 95.2%.The overall response rate was 50.0%,including a complete response rate of 13.3% and a partial response rate of 36.7%.The 1-and 2-year local control rates were 30.0% and 8.0% respectively.The median local control survival time was 7.8 month.The 1-and 2-year survival rates were 66.5% and 32.9% respectively.The median overall survival time was 21.5 months.Complications,mainly adverse effects of skin and urinary system (frequent urination,urgent urination,and dysuria) occurred in 6 patients with a rate of 20.0%.Conclusions Minimally invasive and with satisfying efficacy and tolerable complications,CT-guided 125I radioactive seed implantation is a favorable option for treatment of LRRC,especially for the patients who have undergone previous pelvic radiation.
6.The optimal combination of mechanical ventilatory parameters under general anesthesia in obese patients undergoing laparoscopic surgery
Zhanfang LI ; Zhijun MIN ; Qinghua LI ; Zhongyi TIAN ; Cheng LU ; Bo JIANG ; Weiqing TANG ; Ping ZHOU ; Huishu WANG
Fudan University Journal of Medical Sciences 2010;37(1):11-15
Objective Pulmonary dysfunction is common in the obese patients after laparoscopic surgery. To reduce or avoid this complication caused by improper combination of mechanical ventilatory parameters,we conducted the following trial of 3 factors with 3 levels of mechanical ventilation in order to explore the optimal combination with low airway pressure. Methods Patients were randomly allocated into 9 groups (k=3,n=27) according to the "30≤BMI<40" obesity index (ASAⅠ-Ⅱ). Anesthesia machine parameters were set as follows: respiratory frequency (f), tidal volume (VT), respiratory ratio (I:E) as the three factors of A, B, C, with 3 levels of f=15, 12, 9 (bpm), VT=8, 10, 12 (mL/kg), I:E=1:2.5, 1:2.0, 1:1.5. By using L9(3~4)K=3 repeat orthogonal experimental design and analysis table, the variable factors that affect the respiratory index such as the end tidal carbon dioxide pressure (P_(ET)CO_2), peak airway pressure (PIP), mean airway pressure (P_(mean)), and the end of endogenous airway pressure (PEEPi) were analyzed. Results In this study, 27 cases undergoing laparoscopic surgery under general anesthesia were allocated into 9 experimental groups. The hemodynamics of these patients was stable, SPO_2 was kept at 100 percent during the operation. The results of different combinations were described as follows: ①P_(ET)CO_2: f and VT with different level had great impact on P_(ET)CO_2 (P<0.01), I:E had no significant difference in three levels (P>0.05);② PIP: f had great effect on PIP (P<0.05);VT and I:E in three levels also had significant effect on PIP(P<0.01);③ P_(mean): all the ventilation parameters with different combination had significant effect on P_(mean)(P<0.01). Conclusions The best combination of respiratory parameters is A3B1C2, i.e., f=9 bpm, VT=8 mL/kg, and I:E=1:2.0, which indicates that neither small tidal volume and faster frequency, nor slow frequency large tidal volume is a good choice. In order to let obese patients under general anesthesia obtain the best lung protective effect by low airway pressure with good ventilation, it is worth noting that: ①I:E has a great effect on airway pressure (PIP, P_(mean)), which is important for lung protection;②I:E has the opposite effect on PIP and P_(mean).

Result Analysis
Print
Save