1.Analysis of the current situation of occupational protection knowledge-attitude-practice of noise-exposed workers at an airport apron
Huimin YU ; Mei WANG ; Xuefei LIU ; Wanjun LI ; Li ZHANG ; Jun LIU ; Baoli LU
China Occupational Medicine 2025;52(1):56-60
Objective To analyze the current situation of the knowledge-attitude-practice among noise-exposed workers at an airport apron. Methods A total of 494 noise-exposed workers from an airport apron were selected as the study subjects using the judgmental sampling method. A self-designed "Occupational Protection Knowledge, Attitudes, and Practices Questionnaire" was used to assess the current situation of knowledge-attitude-practice on occupational protection. Results Regarding the awareness of noise hazards among the study subjects, the awareness rates of noise-induced impairment on digestive function and reproductive system were the lowest (44.9% and 37.7%, respectively). The awareness rate of noise-induced negative emotions increased with length of service (P<0.01). Regarding the occupational protection knowledge for noise, the awareness rate of occupational noise-induced deafness was “incurable” was the lowest (39.1%). The support rate for five kinds of occupational protection attitudes for noise was generally >85.0%, while only 58.3% of the study subjects consistently or frequently wearing earplugs during work. The most common source of noise hazard and protection knowledge was pre-employment training (76.9%), followed by occupational disease prevention and control campaigns (76.1%). Conclusion Noise-exposed workers in this airport apron have incomplete awareness of non-auditory system hazards caused by noise, and the awareness of knowledge of some occupational protection is relatively low. Although their attitudes toward occupational protection are positive, many workers still fail to consistently wear personal protective equipment at work.
2.Correlation between CD4+T lymphocytes and viral load in newly identified human immunodeficiency virus infected individuals in Huangpu District,Shanghai,2023
Shuang ZHU ; Jieqiong ZHAN ; Lili SONG ; Yu WANG ; Wei CHU ; Weihua CHEN ; Huimin XU
Shanghai Journal of Preventive Medicine 2025;37(2):125-128
ObjectiveTo analyze the detected results of CD4+T lymphocytes and viral load in newly identified human immunodeficiency virus (HIV) infected patients in Huangpu District of Shanghai in 2023, to explore the correlation between them, so as to provide a scientific basis for the development of targeted prevention and control measures and antiviral treatment programs. MethodsThe data of CD4 cell count, viral load and demographic characteristics of the newly infected patients living with HIV in Huangpu District, Shanghai in 2023 were collected and analyzed by using descriptive epidemiological method. ResultsThe mean CD4 cell count of the 67 newly identified HIV infected patients in Huangpu District was (301.22±235.19) cells·µL-1, with a mean viral load of (5.15±1.28) ×105 copies·mL-1.There were statistically significant differences in CD4 cell count and viral load among different age groups (P<0.05), but there were no statistically significant differences by gender and marital status (both P>0.05). The CD4 cell count and CD4/CD8 ratio both were negatively correlated with the lg value of viral load (r=-0.290, -0.378; P=0.027, 0.002). ConclusionThe CD4 cell counts of the newly identified HIV infected patients in Huangpu District in 2023 were generally low, the proportion of patients with high viral load was high, but the risk for elderly infected with HIV was high. The elderly have gradually become the key population for AIDS prevention and control in Huangpu District. It is recommended to expand HIV screening in the elderly to reduce the risk of HIV transmission and increase the rate of early detection and treatment.
3.Chlorhexidine and Fondaparinux-Induced Kounis Syndrome: a Case Report
Fangzheng YU ; Yajing WANG ; Hang LIN ; Lifeng ZHANG ; Yuhui ZHU ; Xiaomeng SHI ; Huimin ZHOU ; Nan LIN ; Xiang GAO
JOURNAL OF RARE DISEASES 2025;4(3):334-340
Kounis syndrome is an acute coronary syndrome triggered by an allergic reaction, which is clinically rare and frequently subject to misdiagnosis or missed diagnosis. This article presents a case report of a 70-year-old male patient who developed a rash, pruritus, and chest pain following colon polyp resection. Coronary angiography revealed occlusion of the left anterior descending artery, and blood flow was restored after stent implantation. However, the patient experienced recurrent symptoms accompanied by loss of consciousness. Drug skin tests confirmed positive reactions to chlorhexidine and fondaparinux sodium, leading to a diagnosis of type Ⅱ Kounis syndrome. By avoiding allergenic drugs and combining antihistamines with symptomatic treatment to correct myocardial ischemia, the patient′s clinical symptoms significantly improved, and he eventually recovered and was discharged from the hospital. This case underscores the importance of maintaining vigilance for this syndrome in patients with allergies accompanied by chest pain and promptly identifying and avoiding allergens.
4.Analysis of fungal infections of external auditory canal and its risk factors in patients with chronic otitis media.
Jilei ZHANG ; Youqi LU ; Qi LIU ; Yuanyuan JING ; Lisheng YU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(1):57-60
Objective:The objective of this study is to analyze the detection rate, the pathogenic fungus distribution, risk factors and drug sensitivity of fungal infection of external auditory canal in patients diagnosed with chronic otitis media. Methods:The data of a total of 419 patients with chronic suppurative otitis media or middle ear cholesteatoma who were admitted from January 2019 to February 2023 were retrospectively analyzed. Results:A total of 419 patients were included, and 71 patients(16.9%) were positive for fungal culture. The disease mostly occurred in subjects aged 51-60 years old, and patients over 60 years old(47 cases, 66.2%). From the fungal culture of external auditory canal secretions, 48 cases(11.4%) of Aspergillus and 14 cases(3.3%) of Candida were identified. The prevalence of fungal cultures in patients with chronic suppurative otitis media(20.8%) was significantly higher than that in patients with middle ear cholectestoma(4.9%). The detection rate of Fungal was significantly increased after topical treatment with antibiotic ear drops(47.0% vs 13.6%). Most of the isolated fungal strains are wild-type, and they are the sensitivity to voriconazole and fluconazole was the highest(97.2%). For patients with positive fungal culture, iodoform gauze with triamcinolone acetonide and econazole cream was used to fill the external auditory canal during surgery. There was no significant difference in the tympanic membrane healing rate between patients with positive fungal culture and patients with negative fungal culture at 3 weeks after surgery(98.6% vs 97.7%). Conclusion:Fungal infections of external auditory canal in patients with chronic otitis media tend to occur in older patients, which is more common in patients with chronic suppurative otitis media. Long-term topical treatment with antibiotic ear drops is an independent risk factor for fungal infection of external auditory canal in patients with chronic otitis media. The isolated fungal strains were highly sensitive to antifungal drugs. Therefore, it is advisable to refrain from employing topical antibiotic treatment for elderly patients with chronic suppurative otitis media/middle ear cholesteatoma, abuse of local antibiotic therapy should be avoided, and Fungal-related pathogenic examinations should be actively performed and anti-fungal drugs should be added if necessary.
Humans
;
Middle Aged
;
Female
;
Male
;
Risk Factors
;
Retrospective Studies
;
Chronic Disease
;
Otitis Media, Suppurative/microbiology*
;
Ear Canal/microbiology*
;
Antifungal Agents/therapeutic use*
;
Adult
;
Mycoses/epidemiology*
;
Aspergillus/isolation & purification*
;
Candida/isolation & purification*
;
Otitis Media/complications*
;
Aged
;
Cholesteatoma, Middle Ear/microbiology*
5.High expression of miR-124 improves cognitive function of sleep-deprived rats by modulating the PI3K/AKT signaling pathway.
Yuejiao PEI ; Huimin LIU ; Yu XIN ; Bo LIU
Journal of Southern Medical University 2025;45(2):340-346
OBJECTIVES:
To explore the molecular mechanism by which miR-124 affects cognitive function of sleep-deprived rats.
METHODS:
Fifty-four adult male SD rats were randomized into 6 groups (n=9), including a normal control group, a sleep deprivation (SD) model group, and 4 intracerebral microinjection groups in which the rats were subjected to stereotactic injection of miR-124 agomir, miR-124 agomir NC, miR-124 antagomir, or miR-124 antagomir into the lateral ventricle 7 days before SD modeling. The cognitive functions of the rats were evaluated with Morris water maze test, and pathological changes in the hippocampus were observed using HE staining. The expression level of miR-124 in hippocampal tissues of the rats was detected with qRT-PCR, and the expression level of apoptosis-related proteins and signaling pathway proteins were determined using Western blotting.
RESULTS:
In Morris water maze test, the SD rat models treated with miR-124 agomir showed a significantly shorter escape latency and fewer platform crossings with increased percentage of time and swimming distance in the fourth quadrant as compared with those in SD model group, while the rats treated with miR-124 antagomir exhibited worsened performance in the test. In the SD rat models, treatment with miR-124 agomir obviously lessened pathological changes in the hippocampus, while treatment with miR-124 antagomir significantly worsened the pathological changes. Compared with those in SD model group, the miR-124 agomir-treated rats showed an increased hippocampal expression of miR-124 with upregulated protein expressions of PI3K, p-AKT/AKT, and Bcl-2 and downregulated expressions of Bax and caspase-3 proteins, while rats treated with miR-124 antagomir showed significantly decreased hippocampal expression of miR-124 with lowered expressions of PI3K, p-AKT/AKT and Bcl-2 proteins and increased Bax and caspase-3 protein expressions.
CONCLUSIONS
High expression of miR-124 alleviates SD-induced cognitive decline and neuronal apoptosis in rats by activating the PI3K/AKT signaling pathway.
Animals
;
MicroRNAs/metabolism*
;
Signal Transduction
;
Proto-Oncogene Proteins c-akt/metabolism*
;
Male
;
Rats, Sprague-Dawley
;
Hippocampus/metabolism*
;
Phosphatidylinositol 3-Kinases/metabolism*
;
Cognition
;
Rats
;
Sleep Deprivation/metabolism*
;
Apoptosis
;
Maze Learning
6.Tianxiangdan (TXD) alleviates myocardial ischemia reperfusion-induced ferroptosis through the activation of estrogen receptor alpha (ERα).
Yuanjia YUE ; Yu LI ; Xing RONG ; Zhao JI ; Huimin WANG ; Liang CHEN ; Lin JIANG
Chinese Journal of Natural Medicines (English Ed.) 2025;23(1):102-110
Tianxiangdan (TXD), a traditional Chinese herbal remedy, demonstrates efficacy in mitigating myocardial ischemia-reperfusion (I/R)-induced damage. This study employed network pharmacology to evaluate the therapeutic targets and mechanisms of TXD in treating I/R. High-performance liquid chromatography-mass spectrometry (HPLC-MS) identified 86 compounds in TXD. Network pharmacological analysis predicted potential target genes and their modes of action. Cardiac function, ischaemic ST changes, lactate dehydrogenase (LDH), malondialdehyde (MDA), superoxide dismutase (SOD) activity, myocardial fiber, and infarct size were assessed using in vivo and in vitro I/R injury models. Estrogen receptor alpha (ERα) protein expression and estradiol (E2) levels were measured to confirm TXD's impact on estrogen levels and ERα expression. To examine if TXD reduces I/R injury through ERα, an AZD group (300 nmol·L-1 AZD9496 and 15% TXD serum) was compared to a TXD group (15% TXD serum). The study hypothesized that TXD upregulates the ERα-mediated iron metamorphosis pathway. I/R injury-induced ferroptosis was identified using a Fer-1 group (1.0 μmol·L-1 Fer-1 and 15% TXD serum) to elucidate the potential association between ferroptosis and ERα proteins. A DCFH-DA probe detected reactive oxygen species (ROS) and Fe2+, while Western blotting assessed target protein expression. Both in vitro and in vivo experiments demonstrated that TXD attenuated I/R injury by reducing elevated ST-segment levels, improving cardiac injury biomarkers (LDH, MDA, and SOD), alleviating pathological features, and preventing I/R-induced loss of cell viability in vitro. The effects and mechanisms of TXD on I/R injury-associated ferroptosis were investigated using I/R-induced H9c2 cells. The TXD group showed significantly decreased ROS and Fe2+ levels, while the AZ group (treated with AZD9496) exhibited increased levels. The TXD group demonstrated enhanced expression of ERα and glutathione peroxidase 4 (GPX4), with reduced levels of P53 protein and ferritin-heavy polypeptide 1 (FTH1). The AZ group exhibited contrasting effects on these expression levels. The literature indicated a novel connection between ERα and ferroptosis. TXD activates the ERα signaling pathway, promoting protection against I/R-induced myocardial cell ferroptosis. This study provides evidence supporting TXD use for myocardial ischemia treatment, particularly in older female patients who may benefit from its therapeutic outcomes.
Animals
;
Ferroptosis/drug effects*
;
Estrogen Receptor alpha/genetics*
;
Myocardial Reperfusion Injury/genetics*
;
Drugs, Chinese Herbal/pharmacology*
;
Male
;
Mice
;
Humans
;
Mice, Inbred C57BL
;
Estradiol/metabolism*
7.The effect of different particle activities and tumor shrinkage speed on the dosimetric parameters of the target area after 125I particle implantation
Huimin YU ; Jinxin ZHAO ; Jiantao DONG ; Xuemin DI ; Zhen GAO ; Juan WANG ; Hongtao ZHANG
Journal of Interventional Radiology 2025;34(3):272-277
Objective To discuss the effect of different particle activities and tumor shrinkage speed on the dosimetric parameters of the target area at the same prescription dose after 125I particle implantation.Methods A 6cm-sized cube tumor model was outlined by using a computerized three-dimensional treatment planning system(3D-TPS)with a prescription dose(PD)of 100 Gy,and 125I particle activities of 0.4 mCi and 0.8 mCi were selected.Assuming that the tumor shrinks centripetally after seed implantation and that the 125I particles were uniformly and centripetally concentrated without shedding or wandering,the tumor volume shrank at different rates every month after implantation(0,5%,10%,15%,20%,25%,30%,35%,40%,45%and 50%),according to the different activities of 125I particles,the experiments were divided into A1-K1 group(0.4 mCi)and A2-K2 group(0.8 mCi).Based on the 125I particle decay law,the validation program(using TPS simulation of the A1-K1 group and A2-K2 group at postoperative 1,2,3,4,5 and 6 months)obtained the dose received by 90%of the target volume(D90)in the two groups with different 125I particle activities at different postoperative time points,the percentages of the target volume covered by the 100%,150%and 90%prescription dose(V100,V150,V90),and the mean dose(Dmean).By comparing the differences in D90,V100,V150,V90 and Dmean after tumor implantation of 125I particles with different activities,the dosimetric impact of the tumor target area shrinking at a rate of 0~50%after implantation of 125I particles with different activities into tumor tissues was analyzed.Results When the monthly shrinkage rate of the tumor target area was≤30%,there was no obvious difference in D90 between the 0.4 mCi group and 0.8 mCi group in 1~6 months after surgery.When the monthly shrinkage rate of the tumor target area was>30%,the D90 of 0.8 mCi group was higher than that of 0.4 mCi group;when the monthly shrinkage rate of the tumor target area was<25%,the V90 of 0.4 mCi group was higher than that of 0.8 mCi group,and the changes of V90 of the two groups tended to be the same in the 5th~6th month after surgery.When the monthly shrinkage rate of the tumor target area was ≥30%,the V90 of 0.8 mCi group was higher than that of 0.4 mCi group,and with the increasing of shrinkage rate,the difference between the two groups become more and more significant,the results of V100 were consistent with those of V90.When the monthly shrinkage rate of tumor target area<35%,V150 of 0.4 mCi group was higher than that of 0.8 mCi group,when the monthly shrinkage rate of tumor target area ≥35%,V150 of 0.8 mCi group was higher than that of 0.4 mCi group,and with the increasing of shrinkage rate,the difference between the two groups become more and more prominent.When the monthly shrinkage rate of tumor target area<25%,Dmean of 0.4 mCi group was higher than that of 0.8 mCi group,when the monthly shrinkage rate of tumor target area ≥25%,Dmean of 0.8 mCi group was higher than that of 0.4 mCi group,and with the increasing of shrinkage rate,the difference between the two groups become more and more obvious.Conclusion With the same prescription dose,when the tumor target area shrinks at a rate of<30%per month,the activity of 125I particles has little effect on D90,and all V90,V100,V150 and Dmean in the low activity group are higher than those in the high activity group,meanwhile the homogeneity of the target area is relatively good;when the monthly shrinkage rate of tumor target area ≥35%,all D90,V90,V100,V150 and Dmean in the high activity group are higher than those in the low activity group,and the duration of the presence of high-dose area is long.This difference becomes more obvious with the increasing of the monthly shrinkage rate of the target area.
8.The impact of 125I seeds strand length on different reference points dose
Ke XU ; Dingxin WANG ; Guozhang XING ; Huimin YU ; Jinxin ZHAO ; Zezhou LIU ; Zeyang WANG ; Hongtao ZHANG ; Juan WANG
Journal of Interventional Radiology 2025;34(6):609-613
Objective To investigate the effect of different strand lengths of 125I seeds with the same activity on the dose of different reference points around the seeds.Methods The scanned images were transferred to the three-dimensional treatment planning system(3D-TPS)according to DICOM format.The target volume was delineated at 5 mm and 10 mm above and below the center of the phantom,and a 0.8 mCi seeds strand was simulated.The 1-20 seeds were arranged with an equal spacing of 5 mm(5 mm-100 mm).The 5 mm points above and below the center of the seeds strand were defined as point A and point A',and the 10 mm points above and below the center were defined as point B and point B'.5 mm above and below the edge of the seeds strand on the left side were defined as AL points and AL'points,and 5 mm above and below the edge of the seeds strand on the right side were defined as AR points and AR'points.Similarly,points 10 mm above the above mentioned positions were defined as BL points,BL'points,BR points,BR'points.The average dose symmetry points were measured at AL,AL',AR,and 5 mm,10 mm,15 mm and 20 mm inside AR' of the 45 mm-100 mm seeds strand.The dose at the center was compared with the dose at the end points.The dose at the center point A was compared with the average dose at the symmetry points of 5 mm,10 mm,15 mm and 20 mm inside of the end points AL,AL',AR and AR',and the dose at each point was curve fitting.The correlation between each point and seeds strands of different lengths was analyzed.Results There was a positive correlation between the dose and the length of each point.There was no statistically significant difference between the center point and the end point.There was a statistically significant difference in dosage at points 5 mm and 10 mm inside from point A,while there was no statistically significant difference in dosage at points 15 mm and 20 mm inside from point A.The dose of A,A',B and B' point increased steadily with the increase of seed chain length,and the fitting curves were obtained respectively:y=e(-0.620/x+5.28)(R2=0.992),y=e(-0.640/x+5.34)(R2=0.987),y=e(-0.82/x+4.80)(R2=0.984),y=e(-0.82/x+4.83)(R2=0.9g1).Conclusion The doses at points A,A',B,and B'are positively correlated with seeds strand length and have a high degree of stability.Point A can be used as a reference point for the target area dose of the seeds strand,and point B can be used as a reference point for the dose to critical organs.The dose at other positions is more variable and thus has a certain degree of uncertainty as a reference point for the seeds strand dose.
9.The impact of 125I seeds strand radian on the dose of different reference points
Jinxin ZHAO ; Dingxin WANG ; Guozhang XING ; Ke XU ; Zezhou LIU ; Huimin YU ; Zeyang WANG ; Juan WANG ; Hongtao ZHANG
Journal of Interventional Radiology 2025;34(12):1333-1337
Objective To investigate the impact of different 125I seeds strand radian on the dose of different reference points around the seeds.Methods CT scan of self-developed radioactive particle radiation dose measurement phantom was performed,the scanned images were transferred to the three-dimensional treatment planning system(TPS).The target area at the middle level of the model was drawn.The target volume was delineated at 5 mm and 10 mm above and below the center of the phantom.125I seeds strand plans were designed with different radians,with a total length of 8 cm,seed spacing of 0 cm,activity of 0.8 mCi,and a total of 16 particles,with radians ranging from 30°to 170°,increasing by 10° increment.The point 5 mm vertically away from the center of the seeds strand towards the center was named A',and the point away from the center was named A.The point 10 mm vertically away from the center of the seeds strand towards the center was named B',and the point away from the center was named B.The doses at different radians were recorded,and the actual absorbed dose at 1-2 months after operation was calculated based on the particle activity decay formula.Results The doses at points A'and A were(218.3±23.1)and(201.5±16.0)Gy respectively(P=0.001).The actual absorbed doses at 1 month after operation were(65.5±6.9)and(60.5±4.8)Gy respectively(P=0.001),and the actual absorbed doses at 2 months after operation were(109.2±11.5)Gy and(100±7.9)Gy respectively(P=0.001).The doses at points B'and B were(95.9±11.0)Gy and(81.7±4.9)Gy respectively(P<0.001),and the actual absorbed doses at 1 month after operation were(28.8±3.3)Gy and(24.5±1.5)Gy respectively(P<0.001).The actual absorbed doses at 2 month after operation were(48.0±5.5)Gy and(41.0±2.4)Gy respectively(P<0.001).The doses at points A'and A gradually decreased with the increase of the radians,reaching the minimum value at 100 degrees,and then increased gradually,showing a cubic function change.The actual absorbed dose showed the same trend.The doses at points B'and B increased gradually with the increase of the radians,showing a cubic function change.Conclusion At different radians,the point doses and absorbed doses on the centrifugal side of the seeds strand are both less than those on the centripetal side.There is a cubic function relationship between the dose at the reference points and the radian of the seeds strand.
10.Predictive Value of KIAA1199 and Linc00673 Genes on Chemotherapy Efficacy in Non-small Cell Lung Cancer
Huimin YU ; Xin XIN ; Zhiwei LIANG
Journal of Kunming Medical University 2025;46(1):111-116
Objective To explore the expression changes of KIAA1199 and Linc00673 genes in non-small cell lung cancer patients before and after chemotherapy,and to further evaluate the potential value of these two genes as molecular markers in predicting chemotherapy efficacy.Methods A total of 58 patients with stage Ⅲ-ⅣNSCLC admitted to the Third Hospital of Shijiazhuang and Fengfeng General Hospital of North China Medical Health Group from August 2019 to August 2021 were selected.Peripheral blood PBMCs were collected from patients 2 days before treatment and after two cycles of treatment to detect the expression levels of KIAA1199 and Linc00673 genes.The chemotherapy efficacy of patients was statistically analyzed,and the value of KIAA1199 and Linc00673 genes as molecular markers in predicting chemotherapy efficacy was assessed using ROC curve analysis.Results After 2 cycles of chemotherapy,20 out of 58 patients showed disease progression,accounting for 34.48%.qPCR results showed no statistically significant difference in the expression levels of KIAA1199 and Linc00673 genes between progressed and non-progressed patients before treatment(P>0.05).After treatment,the expression levels of KIAA1199 and Linc00673 genes were significantly lower in non-progressed patients compared to progressed patients(P<0.01).ROC curve analysis showed that the AUC of combined detection was significantly higher than that of KIAA1199 gene and Linc00673 gene alone(Z=3.054,5.178,P<0.05).Conclusion In NSCLC patients undergoing chemotherapy,the expression of KIAA1199 and Linc00673 genes shows significant differences based on therapeutic efficacy,with KIAA1199 being more suitable as a biomarker for predicting chemotherapy efficacy.

Result Analysis
Print
Save
E-mail