1.Comparative study of UE and CDFI in distinguishing triple-negative breast cancer and fibroadenoma
Qiufeng LI ; Yeping FENG ; Huili LI ; Xiangyu LI ; Zhenxiu HUANG
China Medical Equipment 2024;21(1):88-92
Objective:To investigate the values of ultrasound elasticity(UE)imaging and color Doppler flow energy(CDFI)in differential diagnosis for triple negative breast cancer(TNBC)and fibroadenoma.Methods:A total of 50 TNBC patients who admitted to People's Hospital of Wanning from January 2021 to January 2022 and were confirmed by surgical pathology were selected,and they were divided into TNBC group.On the other hand,a total of 50 patients with fibroadenoma who were confirmed by surgical pathology during the same period were selected and they were divided into fibroadenoma group.All patients did not undergo any clinical intervention before ultrasound examination.UE and CDFI were used respectively to evaluate the degrees of softness and hardness of the tissues,the color blood flow and elasticity scores of lesions.The pathological result was used as the gold standard to analyze respectively the diagnostic efficacies of UE and CDFI for TNBC and fibroadenoma.Results:According to the characteristics of ultrasound imaging,the TNBC group mostly showed burr sign on lesion edge,the attenuation and hyperechoic halo of posterior echo,and existing axillary lymph node metastasis.The fibroadenoma group mostly showed clear boundaries of lesion area,regular lesion morphology,non-microcalcification.The diagnostic sensitivity,specificity and accuracy of UE detection were respectively 90.91%,82.14%and 86.00%,while these indicators of CDFI were respectively 73.08%,75.00%and 74.00%.In addition,the sensitivity,specificity and accuracy of the combined detection of them were respectively 94.23%,95.83%and 96.00%.The detection efficiency of the combined detection was higher than that of each single detection.Conclusion:UE has higher sensitivity in the differential diagnosis of TNBC and fibroadenoma,but it's specificity is not high.The combined detection of UE and CDFI can improve the specificity and accuracy of differential diagnosis.
2.Development and validation of a novel criterion of histologic healing in ulcerative colitis defined by inflammatory cell enumeration in lamina propria mucosa: A multicenter retrospective cohort in China
Han GAO ; Kangsheng PENG ; Yadi SHI ; Shenshen ZHU ; Ruicong SUN ; Chunjin XU ; Ping LIU ; Zhi PANG ; Lanxiang ZHU ; Weichang CHEN ; Baisui FENG ; Huili WU ; Guangxi ZHOU ; Mingsong LI ; Junxiang LI ; Baijing DING ; Zhanju LIU
Chinese Medical Journal 2024;137(11):1316-1323
Background::Histological healing is closely associated with improved long-term clinical outcomes and lowered relapses in patients with ulcerative colitis (UC). Here, we developed a novel diagnostic criterion for assessing histological healing in UC patients.Methods::We conducted a retrospective cohort study in UC patients, whose treatment was iteratively optimized to achieve mucosal healing at Shanghai Tenth People’s Hospital of Tongji University from January 2017 to May 2022. We identified an inflammatory cell enumeration index (ICEI) for assessing histological healing based on the proportions of eosinophils, CD177 + neutrophils, and CD40L + T cells in the colonic lamina propria under high power field (HPF), and the outcomes (risks of symptomatic relapses) of achieving histological remission vs. persistent histological inflammation using Kaplan-Meier curves. Intrareader reliability and inter-reader reliability were evaluated by each reader. The relationships to the changes in the Nancy index and the Geboes score were also assessed for responsiveness. The ICEI was further validated in a new cohort of UC patients from other nine university hospitals. Results::We developed an ICEI for clinical diagnosis of histological healing, i.e., Y = 1.701X 1 + 0.758X 2 + 1.347X 3 - 7.745 (X 1, X 2, and X 3 represent the proportions of CD177 + neutrophils, eosinophils, and CD40L + T cells, respectively, in the colonic lamina propria under HPF). The receiver operating characteristics curve (ROC) analysis revealed that Y <-0.391 was the cutoff value for the diagnosis of histological healing and that an area under the curve (AUC) was 0.942 (95% confidence interval [CI]: 0.905-0.979) with a sensitivity of 92.5% and a specificity of 83.6% ( P <0.001). The intraclass correlation coefficient (ICC) for the intrareader reliability was 0.855 (95% CI: 0.781-0.909), and ICEI had good inter-reader reliability of 0.832 (95% CI: 0.748-0.894). During an 18-month follow-up, patients with histological healing had a substantially better outcome compared with those with unachieved histological healing ( P <0.001) using ICEI. During a 12-month follow-up from other nine hospitals, patients with histological healing also had a lower risk of relapse than patients with unachieved histological healing. Conclusions::ICEI can be used to predict histological healing and identify patients with a risk of relapse 12 months and 18 months after clinical therapy. Therefore, ICEI provides a promising, simplified approach to monitor histological healing and to predict the prognosis of UC.Registration::Chinese Clinical Trial Registry, No. ChiCTR2300077792.
3.Down-regulation of microRNA-382-5p reduces neuropathic pain by targeting regulation of dual specificity phosphatase-1
Anjie XU ; Huili SHEN ; Shasha MEI ; Zhongwei WANG ; Qiuyi XIE ; Huaqing CUI ; Yunchao CHU ; Baihe FENG
The Korean Journal of Pain 2024;37(4):320-331
Background:
MicroRNA (miRNA) plays a crucial role in neuropathic pain (NP) by targeting mRNAs. This study aims to analyze the regulatory function and mechanism of miR-382-5p/dual specificity phosphatase-1 (DUSP1) axis in NP.
Methods:
We utilized rats with chronic constriction injury (CCI) of the sciatic nerve as the NP model. The levels of miR-382-5p and DUSP1 were reduced by intrathecal injection of lentiviral interference vectors targeting miR-382-5p and DUSP1. The mRNA levels of miR-382-5p and DUSP1 in the dorsal root ganglions (DRGs) were measured by RT-qPCR assay. The pain behavior was evaluated by mechanical nociceptive sensitivity and thermal nociceptive sensitivity. The expression levels of interleukin-6 (IL)-6, IL-1β, and tumor necrosis factor-α in the DRGs were analyzed by ELISA assay. The targeting relationship between miR-382-5p and DUSP1 was verified by DLR assay and RIP assay.
Results:
Compared to the Sham group, the CCI rats exhibited higher levels of miR-382-5p and lower levels of DUSP1. Overexpression of miR-382-5p significantly decreased DUSP1 levels. Reducing miR-382-5p levels can lower the mechanical nociceptive sensitivity and thermal nociceptive sensitivity of CCI rats and inhibit the over-activation of pro-inflammatory factors. Reduced miR-382-5p levels decreased NP in CCI rats. DUSP1 is the target of miR-382-5p, and down-regulation of DUSP1 reverses the inhibitory effect of reduced miR-382-5p levels on NP.
Conclusions
Down-regulation of miR-382-5p inhibits the over-activation of pro-inflammatory factors by targeting and regulating the expression of DUPS1, thereby alleviating NP.
4.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.
5.Down-regulation of microRNA-382-5p reduces neuropathic pain by targeting regulation of dual specificity phosphatase-1
Anjie XU ; Huili SHEN ; Shasha MEI ; Zhongwei WANG ; Qiuyi XIE ; Huaqing CUI ; Yunchao CHU ; Baihe FENG
The Korean Journal of Pain 2024;37(4):320-331
Background:
MicroRNA (miRNA) plays a crucial role in neuropathic pain (NP) by targeting mRNAs. This study aims to analyze the regulatory function and mechanism of miR-382-5p/dual specificity phosphatase-1 (DUSP1) axis in NP.
Methods:
We utilized rats with chronic constriction injury (CCI) of the sciatic nerve as the NP model. The levels of miR-382-5p and DUSP1 were reduced by intrathecal injection of lentiviral interference vectors targeting miR-382-5p and DUSP1. The mRNA levels of miR-382-5p and DUSP1 in the dorsal root ganglions (DRGs) were measured by RT-qPCR assay. The pain behavior was evaluated by mechanical nociceptive sensitivity and thermal nociceptive sensitivity. The expression levels of interleukin-6 (IL)-6, IL-1β, and tumor necrosis factor-α in the DRGs were analyzed by ELISA assay. The targeting relationship between miR-382-5p and DUSP1 was verified by DLR assay and RIP assay.
Results:
Compared to the Sham group, the CCI rats exhibited higher levels of miR-382-5p and lower levels of DUSP1. Overexpression of miR-382-5p significantly decreased DUSP1 levels. Reducing miR-382-5p levels can lower the mechanical nociceptive sensitivity and thermal nociceptive sensitivity of CCI rats and inhibit the over-activation of pro-inflammatory factors. Reduced miR-382-5p levels decreased NP in CCI rats. DUSP1 is the target of miR-382-5p, and down-regulation of DUSP1 reverses the inhibitory effect of reduced miR-382-5p levels on NP.
Conclusions
Down-regulation of miR-382-5p inhibits the over-activation of pro-inflammatory factors by targeting and regulating the expression of DUPS1, thereby alleviating NP.
6.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.
7.Down-regulation of microRNA-382-5p reduces neuropathic pain by targeting regulation of dual specificity phosphatase-1
Anjie XU ; Huili SHEN ; Shasha MEI ; Zhongwei WANG ; Qiuyi XIE ; Huaqing CUI ; Yunchao CHU ; Baihe FENG
The Korean Journal of Pain 2024;37(4):320-331
Background:
MicroRNA (miRNA) plays a crucial role in neuropathic pain (NP) by targeting mRNAs. This study aims to analyze the regulatory function and mechanism of miR-382-5p/dual specificity phosphatase-1 (DUSP1) axis in NP.
Methods:
We utilized rats with chronic constriction injury (CCI) of the sciatic nerve as the NP model. The levels of miR-382-5p and DUSP1 were reduced by intrathecal injection of lentiviral interference vectors targeting miR-382-5p and DUSP1. The mRNA levels of miR-382-5p and DUSP1 in the dorsal root ganglions (DRGs) were measured by RT-qPCR assay. The pain behavior was evaluated by mechanical nociceptive sensitivity and thermal nociceptive sensitivity. The expression levels of interleukin-6 (IL)-6, IL-1β, and tumor necrosis factor-α in the DRGs were analyzed by ELISA assay. The targeting relationship between miR-382-5p and DUSP1 was verified by DLR assay and RIP assay.
Results:
Compared to the Sham group, the CCI rats exhibited higher levels of miR-382-5p and lower levels of DUSP1. Overexpression of miR-382-5p significantly decreased DUSP1 levels. Reducing miR-382-5p levels can lower the mechanical nociceptive sensitivity and thermal nociceptive sensitivity of CCI rats and inhibit the over-activation of pro-inflammatory factors. Reduced miR-382-5p levels decreased NP in CCI rats. DUSP1 is the target of miR-382-5p, and down-regulation of DUSP1 reverses the inhibitory effect of reduced miR-382-5p levels on NP.
Conclusions
Down-regulation of miR-382-5p inhibits the over-activation of pro-inflammatory factors by targeting and regulating the expression of DUPS1, thereby alleviating NP.
8.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.
9.Down-regulation of microRNA-382-5p reduces neuropathic pain by targeting regulation of dual specificity phosphatase-1
Anjie XU ; Huili SHEN ; Shasha MEI ; Zhongwei WANG ; Qiuyi XIE ; Huaqing CUI ; Yunchao CHU ; Baihe FENG
The Korean Journal of Pain 2024;37(4):320-331
Background:
MicroRNA (miRNA) plays a crucial role in neuropathic pain (NP) by targeting mRNAs. This study aims to analyze the regulatory function and mechanism of miR-382-5p/dual specificity phosphatase-1 (DUSP1) axis in NP.
Methods:
We utilized rats with chronic constriction injury (CCI) of the sciatic nerve as the NP model. The levels of miR-382-5p and DUSP1 were reduced by intrathecal injection of lentiviral interference vectors targeting miR-382-5p and DUSP1. The mRNA levels of miR-382-5p and DUSP1 in the dorsal root ganglions (DRGs) were measured by RT-qPCR assay. The pain behavior was evaluated by mechanical nociceptive sensitivity and thermal nociceptive sensitivity. The expression levels of interleukin-6 (IL)-6, IL-1β, and tumor necrosis factor-α in the DRGs were analyzed by ELISA assay. The targeting relationship between miR-382-5p and DUSP1 was verified by DLR assay and RIP assay.
Results:
Compared to the Sham group, the CCI rats exhibited higher levels of miR-382-5p and lower levels of DUSP1. Overexpression of miR-382-5p significantly decreased DUSP1 levels. Reducing miR-382-5p levels can lower the mechanical nociceptive sensitivity and thermal nociceptive sensitivity of CCI rats and inhibit the over-activation of pro-inflammatory factors. Reduced miR-382-5p levels decreased NP in CCI rats. DUSP1 is the target of miR-382-5p, and down-regulation of DUSP1 reverses the inhibitory effect of reduced miR-382-5p levels on NP.
Conclusions
Down-regulation of miR-382-5p inhibits the over-activation of pro-inflammatory factors by targeting and regulating the expression of DUPS1, thereby alleviating NP.
10.Application of O-RADS US combined with MV-Flow to diagnose ovarian-adnexal tumors
Linlin RUAN ; Hui LIU ; Hong XIANG ; Yongkang NI ; Yuling FENG ; Huili ZHOU ; Mengtong QI
Ultrasonography 2024;43(1):15-24
Purpose:
This study aimed to explore the application of Ovarian-Adnexal Reporting and Data System Ultrasound (O-RADS US) combined with MV-Flow (Samsung Medison Co., Ltd.) to diagnose ovarian-adnexal masses.
Methods:
A total of 112 ovarian-adnexal masses (81 benign and 31 malignant) from 105 consecutive patients were analyzed. The O-RADS US and vascular index from MV-Flow (VIMV) were measured and compared with the reference standard. O-RADS US and MV-Flow were tested for consistency.
Results:
Receiver operating characteristic curves were drawn for O-RADS US, MV-Flow, and their combination. The combined methods had the largest area under the curve (0.955), followed by O-RADS US (0.929) and MV-Flow (0.923). A mass was considered malignant when the O-RADS US classification was 5 and VIMV was ≥7.15. With this definition, MV-Flow had the highest sensitivity (87.10%), with consistent findings for the combined diagnostic methods and O-RADS US (83.87%). The specificity of the combined diagnostic methods (93.83%) was higher than that of MV-Flow (91.36%). O-RADS US had the lowest specificity (90.12%). The combined diagnostic methods had the highest coincidence rate (91.07%), and MV-Flow (90.18%) had a significantly higher coincidence rate than O-RADS US (88.39%). Both O-RADS US and MV-Flow showed good consistency among different physicians (former kappa, 0.974; latter intraclass correlation coefficient [ICC], 0.986). MV-Flow had a high consistency for the same physician (ICC, 1).
Conclusion
O-RADS US and MV-Flow exhibited good diagnostic efficacy, and their combined diagnostic efficacy was higher than that of each individually. O-RADS US and MV-Flow can improve the diagnosis of benign and malignant ovarian-adnexal masses.

Result Analysis
Print
Save
E-mail