1.Inhibition of HDAC3 Promotes Psoriasis Development in Mice Through Regulating Th17
Fan XU ; Xin-Rui ZHANG ; Yang-Chen XIA ; Wen-Ting LI ; Hao CHEN ; An-Qi QIN ; Ai-Hong ZHANG ; Yi-Ran ZHU ; Feng TIAN ; Quan-Hui ZHENG
Progress in Biochemistry and Biophysics 2025;52(4):1008-1017
ObjectiveTo investigate the influence of histone deacetylase 3 (HDAC3) on the occurrence, development of psoriasis-like inflammation in mice, and the relative immune mechanisms. MethodsHealthy C57BL/6 mice aged 6-8 weeks were selected and randomly divided into 3 groups: control group (Control), psoriasis model group (IMQ), and HDAC3 inhibitor RGFP966-treated psoriasis model group (IMQ+RGFP966). One day prior to the experiment, the back hair of the mice was shaved. After a one-day stabilization period, the mice in Control group was treated with an equal amount of vaseline, while the mice in IMQ group was treated with imiquimod (62.5 mg/d) applied topically on the back to establish a psoriasis-like inflammation model. The mice in IMQ+RGFP966 group received intervention with a high dose of the HDAC3-selective inhibitor RGFP966 (30 mg/kg) based on the psoriasis-like model. All groups were treated continuously for 5 d, during which psoriasis-like inflammation symptoms (scaling, erythema, skin thickness), body weight, and mental status were observed and recorded, with photographs taken for documentation. After euthanasia, hematoxylin-eosin (HE) staining was used to assess the effect of RGFP966 on the skin tissue structure of the mice, and skin thickness was measured. The mRNA and protein expression levels of HDAC3 in skin tissues were detected using reverse transcription real-time quantitative polymerase chain reaction (RT-qPCR) and Western blot (WB), respectively. Flow cytometry was employed to analyze neutrophils in peripheral blood and lymph nodes, CD4+ T lymphocytes, CD8+ T lymphocytes in peripheral blood, and IL-17A secretion by peripheral blood CD4+ T lymphocytes. Additionally, spleen CD4+ T lymphocyte expression of HDAC3, CCR6, CCR8, and IL-17A secretion levels were analyzed. Immunohistochemistry was used to detect the localization and expression levels of HDAC3, IL-17A, and IL-10 in skin tissues. ResultsCompared with the Control group, the IMQ group exhibited significant psoriasis-like inflammation, characterized by erythema, scaling, and skin wrinkling. Compared with the IMQ group, RGFP966 exacerbated psoriasis-like inflammatory symptoms, leading to increased hyperkeratosis. The psoriasis area and severity index (PASI) skin symptom scores were higher in the IMQ group than those in the Control group, and the scores were further elevated in the IMQ+RGFP966 group compared to the IMQ group. Skin thickness measurements showed a trend of IMQ+RGFP966>IMQ>Control. The numbers of neutrophils in the blood and lymph nodes increased sequentially in the Control, IMQ, and IMQ+RGFP966 groups, with a similar trend observed for CD4+ and CD8+ T lymphocytes in the blood. In skin tissues, compared with the Control group, the mRNA and protein levels of HDAC3 decreased in the IMQ group, but RGFP966 did not further reduce these expressions. HDAC3 was primarily located in the nucleus. Compared with the Control group, the nuclear HDAC3 content decreased in the skin tissues of the IMQ group, and RGFP966 further reduced nuclear HDAC3. Compared with the Control and IMQ groups, RGFP966 treatment decreased HDAC3 expression in splenic CD4+ and CD8+ T cells. RGFP966 treatment increased the expression of CCR6 and CCR8 in splenic CD4+ T cells and enhanced IL-17A secretion by peripheral blood and splenic CD4+ T lymphocytes. Additionally, compared with the IMQ group, RGFP966 reduced IL-10 protein levels and upregulated IL-17A expression in skin tissues. ConclusionRGFP966 exacerbates psoriatic-like inflammatory responses by inhibiting HDAC3, increasing the secretion of the cytokine IL-17A, and upregulating the expression of chemokines CCR8 and CCR6.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.0.05% Cyclosporine A combined with Olopatadine eye drops for the treatment of allergic conjunctivitis-related dry eye disease
Jinfen LI ; Yue LI ; Hui HUANG ; Qianqian LAN ; Zhou ZHOU ; Wenjing HE ; Yuanjun QIN ; Li JIANG ; Fan XU
International Eye Science 2025;25(7):1152-1159
AIM: To explore the efficacy of 0.05% cyclosporine A combined with olopatadine eye drops in treating allergic conjunctivitis-related dry eye disease.METHODS: A total of 63 patients(63 eyes)with allergic conjunctivitis-related dry eye disease in the People's Hospital of Guangxi Zhuang Autonomous Region from August 2022 to April 2023 were enrolled and randomly divided into control group(n=33)and observation group(n=30). The patients of the control group were administrated with 0.1% olopatadine eye drops and 0.3% sodium hyaluronate eye drops, while the observation group was administrated with 0.1% olopatadine eye drops and 0.05% cyclosporine A eye drops. The ocular surface disease index(OSDI), total ocular symptom score(TOSS), conjunctival congestion score, conjunctival papillae and follicle score, Schirmer I test(SⅠt), tear meniscus height(TMH), meibomian gland secretion ability and property score, meibomian gland loss area score, corneal fluorescein staining(CFS), tear film break-up time(BUT), noninvasive first tear film break-up time(NIBUTf), noninvasive average tear film break-up time(NIBUTav)before and after treatment and the drug safety during the treatment period of both groups of patients were evaluated.RESULTS: After treatment, OSDI, TOSS, conjunctival congestion score, conjunctival papillae and follicle score, SⅠt, TMH, meibomian gland secretion ability score and property score, CFS, BUT, NIBUTf, and NIBUTav of the observation group showed improvements compared with those before treatment(all P<0.017). Among these, OSDI, TOSS, conjunctival congestion score, conjunctival papillae and follicle score, BUT, NIBUTf, and NIBUTav demonstrated significant improvement compared with the control group(all P<0.05). There was no statistically significant difference in meibomian gland loss area score between the two groups before and after treatment(P>0.05). During the treatment period, there were no local or systemic adverse reactions.CONCLUSION: The combined use of 0.05% cyclosporine A and olopatadine eye drops can significantly improve ocular discomfort symptoms of patients with dry eye disease associated with allergic conjunctivitis, such as red eyes, itchy eyes and foreign body sensation, promote tear film stability and have high safety.
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Detection and trends of HIVAIDS cases in medical institutions in China from 2017 to 2023
LIANG Fuxin ; WANG Shaorong ; QIN Qianqian ; LI Hui ; HAN Jing ; XU Jie
China Tropical Medicine 2025;25(3):358-
Objective To analyse the crude detection rate and trends of newly detected HIV/AIDS cases in medical institutions in China from 2017 to 2023, and to provide a reference for optimizing HIV testing strategies in medical institutions. Methods Data on HIV testing and newly reported HIV/AIDS cases were analysed using data from the Comprehensive AIDS Prevention and Control Information System of the China Information System for Disease Control and Prevention for the period from 2017 to 2023. HIV testing in medical institutions includes patients tested preoperatively, those tested before transfusion, those tested in sexually transmitted disease (STD) clinics, prenatal care clinics, and other types of patients. Descriptive statistical analysis and χ2 test were performed using SAS 9.4 software. Joinpoint regression was performed using Joinpoint 4.9.0 software to analyse trends of the crude detection rates over time. Results From 2017 to 2023, the person-times of HIV tests in medical institutions increased from 143 million to 255 million, with an increase of 78.07%. The number of newly detected HIV/AIDS cases increased from 74 000 to 88 000 and then declined to 69 000. The crude detection rate of new HIV/AIDS cases declined from 5.18/10 000 to 2.71/10 000, showed a declining trend, the mean annual percentage change was -9.99%(P<0.001). The crude detection rate of new HIV/AIDS cases in STD clinics was the highest among all types of clinic visits (12.79/10 000-24.47/10 000), and the crude detection rate of new cases among all types of clinic visits showed a decreasing trend(P<0.05). Among different medical institutions, general hospitals were the most important source of the number of tests and the number of newly detected HIV/AIDS cases, accounting for more than 62.93% and 62.68%, respectively. Specialised medical institutions had the highest crude detection rate of new cases, which was maintained at more than 5.13/10 000. The crude detection rate of new cases for all four types of medical institutions, except for primary medical institutions, showed a decreasing trend (P<0.05). Conclusions The detection rate of new cases in medical institutions showed a decreasing trend in 2017-2023, and the efficiency of STD clinics testing and detection was higher among all types of attendees. General hospitals are the main source of new cases detection, and testing in specialised medical institutions is more efficient. Testing should be strengthened in key groups of patients and in key medical institutions.
9.Pharmacokinetics and bioequivalence study of teriflunomide tablets in healthy Chinese subjects
Li-Li LIN ; Yan JIANG ; Qin ZHANG ; Hui-Ling QIN ; Qian ZHANG ; Yang XU ; Wei LIANG ; Lin-Ying MENG ; Zhao-Xing CHU ; Wei HU
The Chinese Journal of Clinical Pharmacology 2024;40(3):425-429
Objective To compare the pharmacokinetic profiles of the two teriflunomide tablets in healthy Chinese subjects under fasting and fed conditions and to evaluate their bioequivalence and safety.Methods A randomized,open,single-dose,parallel trial design was used to enroll 31 and 32 healthy Chinese male subjects in the fasting and fed groups,who were randomized to a single oral dose of 14 mg of either reference or test preparation of teriflunomide tablets.The plasma concentrations of teriflunomide were determined using liquid chromatography-tandem mass spectrometry method,and Phoenix WinNonlin 8.1 software was used to calculate pharmacokinetic parameters and perform bioequivalence analysis.Results Subjects received a single oral dose of the reference and test formulations of teriflunomide.The main pharmacokinetic parameters of teriflunomide in the fasting group were as follows:Cmax were(2.14±0.27)and(2.27±0.33)μg·mL-1,AUC0-72h were(105.70±11.20)and(107.72±11.77)μg·mL-1·h,tmax was 1.49 and 0.99 h;the main pharmacokinetic parameters of teriflunomide in the fed group were as follows:Cmaxwere(1.83±0.17)and(1.75±0.22)μg·mL-1,AUC0-72h were(102.66±9.18)and(101.57±13.01)μg·mL-1·h,tmax was 4.01 and 4.99 h.The 90%confidence intervals for the geometric means of Cmax and AUC0-72h for reference and test preparations in the fasting and fed groups were in the range of 80%to 125%.Conclusion The pharmacokinetic characteristics of the 2 formulations were similar under fasting and fed administration conditions,with good bioequivalence and safety;Postprandial administration may delay the time to peak of the drug.
10.Effects of Anchusa italica Retz.on cough variant asthma and the level of TLR4/NF-κB signaling pathway
Liang CHEN ; Xiao-Qin XU ; Wen-Hui GUO ; HAJIAKBER·Aisa ; Di-Na MAI
The Chinese Journal of Clinical Pharmacology 2024;40(5):698-702
Objective To investigate the effect of Anchusa italica Retz.extract on cough variant asthma(CVA)and its mechanism of action.Methods Forty-eight SD rats of each eight were randomly divided into blank group(equal amount of saline),model group(equal amount of saline),control group(250 mg·kg-1 prednisone acetate)and experimental-A1,-A5,-A7 groups(61.1 mg·kg-1 Anchusa italica Retz.extract A1,48.8 mg·kg-1 Anchusa italica Retz.extract A5,201.8 mg·kg-1 Anchusa italica Retz.extract A7),continuous gavage for 28 d;except for the blank group,the other groups were made with ovalbumin-complete Freund's adjuvant.The number of cough times of each rat was observed.The changes in the expression of Toll-like receptor 4(TLR4),myeloid differentiation factor(MyD88)and nuclear factor κB(NF-κB)proteins were observed in the lung tissue.Results The cough times in the blank group,model group,control group and experimental-A1,-A5,-A7 groups were 1.10±0.22,8.33±1.24,3.08±0.65,3.31±0.99,3.08±1.02 and 3.06±0.68;the relative expression levels of TLR4 protein were 0.61±0.01,0.84±0.04,0.66±0.02,0.64±0.04,0.64±0.03 and 0.69±0.02;the relative expression levels of MyD88 protein were 0.54±0.08,0.86±0.06,0.71±0.06,0.65±0.05,0.64±0.08 and 0.70±0.06;the relative expression levels of p-NF-κB protein were 0.48±0.11,0.94±0.06,0.80±0.08,0.68±0.04,0.68±0.06 and 0.78±0.09.Compared with the experimental-A1,-A5,-A7 groups,control group,normal group,the differences were statistically significant in the model group(all P<0.05).Conclusion The extract of Anchusa Italica Retz.can inhibit the symptoms of CVA rats,and the mechanism may be related to the inhibition of TLR4/MyD88/NF-κB signaling pathway.

Result Analysis
Print
Save
E-mail