1.Society of Critical Care Medicine 2024 Guidelines on Adult ICU Design: An Interpretation
Hui ZHANG ; Jianhua SUN ; Wanchen ZHAO ; Lingli XIE ; Cong MA ; Yifan FANG ; Jing CAI ; Na GUO
Medical Journal of Peking Union Medical College Hospital 2026;17(2):421-428
This article provides a systematic interpretation and review of the
2.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
3.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
4.Application Value of Vertebral CT Values in Fresh and Old Fractures Vertebral Bodies of Patients with Osteoporotic Vertebral Compression Fractures
Feng WANG ; Wei-sheng PENG ; Gui-liu CHEN ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(19):3179-3185
Objective:To explore the value of using computed tomography(CT)values to distinguish fresh and old fractures vertebral bodies in osteoporotic vertebral compression fractures(OVCF).Methods:Retrospective analysis of clinical data of 101 OVCF patients in our hospital from September 2022 to September 2023.Kappa test for consistency between magnetic resonance imaging(MRI)and vertebral CT values in distinguished fresh or old OVCF.The difference of CT values between fresh,old fractures and adjacent normal vertebral bodies were compared.The diagnostic efficiency was analyed by receiver operating characteristic(ROC)curve.Results:There was a high consistency between vertebral CT values and MRI in the diagnosis of OVCF in fresh and old fractures(Kappa value=0.934).There was a difference in difference of CT values between adjacent normal vertebral bodies and fresh fractures vertebral bodies(P<0.05).There was a difference in difference of CT values of fresh fractures vertebral bodies and old fractures vertebral bodies(P<0.05).The ROC curve analysis results showed that,the combined measurement of CT values of fresh and old fractured vertebral bodies has an area under the curve(AUC)of 0.723,which was higher than alone measurement of the CT values of fresh fractured vertebral bodies and old fractured vertebral bodies of 0.536 and 0.610(Z=2.548,2.605,2.841,P<0.05).Conclusion:CT values of vertebral bodies show high consistency in distinguish fresh and old fractures of OVCF compared to MRI findings,and the diagnostic efficiency of combine detection is relatively high.
5.Diagnostic Value of Conventional CT Combined with Enhanced CT Scan in Bone Metastases
Feng WANG ; Gui-liu CHEN ; Wei-sheng PENG ; Na DENG ; Xiao-bing HAN ; Hui-liang CAI ; Qiu-xiang CHEN
Progress in Modern Biomedicine 2025;25(20):3337-3344
Objective:To explore the diagnostic value of conventional computed tomography(CT)combined with enhanced CT scan in bone metastases.Methods:This study was a retrospective observational study,84 suspected bone metastases patients admitted to our hospital from January 2022 to August 2024 were selected,All patients underwent conventional CT and enhanced CT scan and pathological examination,Using pathological examination results as the"gold standard"for diagnosis.The imaging manifestations of bone metastases using conventional CT combined with enhanced CT scan examination were observed;The detection rate and bone metastases types of conventional CT and enhanced CT scan were analyzed;The bone metastases location in different types of malignant tumors were analyzed;The detection results of bone metastases between conventional CT and enhanced CT scan were compared;the diagnostic efficacy of conventional CT and enhanced CT scan alone and in combination for bone metastases were analyzed by Receiver operating characteristic(ROC)curve.Results:The detection rate of osteogenic,osteolytic,cystic and mixed bone metastases by conventional CT combined with enhanced CT scan was supered to that of conventional CT and enhanced CT scan alone(P<0.05).Bone metastases from lung cancer,breast cancer and other tumors mainly occur in the spine,limbs and ribs,while esophageal cancer,gastric cancer,liver cancer,prostate cancer,thyroid cancer,renal cancer,and nasopharyngeal cancer had relatively fewer bone metastases.The positive detection cases of bone metastases used conventional CT combined with enhanced CT scan were supered to those used conventional CT and enhanced CT scan alone.The sensitivity,specificity and accuracy of conventional CT combined with enhanced CT scan for the diagnosis of bone metastases were 94.00%,94.11%and 94.04%,respectively,and the positive/negative predictive values were 95.91%and 91.42%,respectively.The sensitivity,specificity and accuracy of conventional CT scan were 84.00%,78.78%and 80.95%,respectively,and the positive/negative predictive values were 85.71%and 74.28%,respectively.The sensitivity,specificity and accuracy of enhanced CT were 89.79%,85.71%and 88.09%,respectively.and the positive and negative predictive values were 89.79%and 85.71%,respectively.The diagnostic efficacy of conventional CT combined with enhanced CT scan for bone metastases was significantly better than that of conventional CT and enhanced CT scan alone.Conclusions:Conventional CT combined with enhanced CT scan can significantly improve the diagnostic efficiency of bone metastases,and provide an important basis for clinical treatment.
6.Effects of Hot Night Exposure on Human Semen Quality: A Multicenter Population-Based Study.
Ting Ting DAI ; Ting XU ; Qi Ling WANG ; Hao Bo NI ; Chun Ying SONG ; Yu Shan LI ; Fu Ping LI ; Tian Qing MENG ; Hui Qiang SHENG ; Ling Xi WANG ; Xiao Yan CAI ; Li Na XIAO ; Xiao Lin YU ; Qing Hui ZENG ; Pi GUO ; Xin Zong ZHANG
Biomedical and Environmental Sciences 2025;38(2):178-193
OBJECTIVE:
To explore and quantify the association of hot night exposure during the sperm development period (0-90 lag days) with semen quality.
METHODS:
A total of 6,640 male sperm donors from 6 human sperm banks in China during 2014-2020 were recruited in this multicenter study. Two indices (i.e., hot night excess [HNE] and hot night duration [HND]) were used to estimate the heat intensity and duration during nighttime. Linear mixed models were used to examine the association between hot nights and semen quality parameters.
RESULTS:
The exposure-response relationship revealed that HNE and HND during 0-90 days before semen collection had a significantly inverse association with sperm motility. Specifically, a 1 °C increase in HNE was associated with decreased sperm progressive motility of 0.0090 (95% confidence interval [ CI]: -0.0147, -0.0033) and decreased total motility of 0.0094 (95% CI: -0.0160, -0.0029). HND was significantly associated with reduced sperm progressive motility and total motility of 0.0021 (95% CI: -0.0040, -0.0003) and 0.0023 (95% CI: -0.0043, -0.0002), respectively. Consistent results were observed at different temperature thresholds on hot nights.
CONCLUSION
Our findings highlight the need to mitigate nocturnal heat exposure during spermatogenesis to maintain optimal semen quality.
Humans
;
Male
;
Semen Analysis
;
Adult
;
Sperm Motility
;
Hot Temperature/adverse effects*
;
China
;
Middle Aged
;
Spermatozoa/physiology*
;
Young Adult
8.GPR40 novel agonist SZZ15-11 regulates glucolipid metabolic disorders in spontaneous type 2 diabetic KKAy mice
Lei LEI ; Jia-yu ZHAI ; Tian ZHOU ; Quan LIU ; Shuai-nan LIU ; Cai-na LI ; Hui CAO ; Cun-yu FENG ; Min WU ; Lei-lei CHEN ; Li-ran LEI ; Xuan PAN ; Zhan-zhu LIU ; Yi HUAN ; Zhu-fang SHEN
Acta Pharmaceutica Sinica 2024;59(10):2782-2790
G protein-coupled receptor (GPR) 40, as one of GPRs family, plays a potential role in regulating glucose and lipid metabolism. To study the effect of GPR40 novel agonist SZZ15-11 on hyperglycemia and hyperlipidemia and its potential mechanism, spontaneous type 2 diabetic KKAy mice, human hepatocellular carcinoma HepG2 cells and murine mature adipocyte 3T3-L1 cells were used. KKAy mice were divided into four groups, vehicle group, TAK group, SZZ (50 mg·kg-1) group and SZZ (100 mg·kg-1) group, with oral gavage of 0.5% sodium carboxymethylcellulose (CMC), 50 mg·kg-1 TAK875, 50 and 100 mg·kg-1 SZZ15-11 respectively for 45 days. Fasting blood glucose, blood triglyceride (TG) and total cholesterol (TC), non-fasting blood glucose were tested. Oral glucose tolerance test and insulin tolerance test were executed. Blood insulin and glucagon were measured
9.Surveillance of antifungal resistance in clinical isolates of Candida spp.in East China Invasive Fungal Infection Group from 2018 to 2022
Dongjiang WANG ; Wenjuan WU ; Jian GUO ; Min ZHANG ; Huiping LIN ; Feifei WAN ; Xiaobo MA ; Yueting LI ; Jia LI ; Huiqiong JIA ; Lingbing ZENG ; Xiuhai LU ; Yan JIN ; Jinfeng CAI ; Wei LI ; Zhimin BAI ; Yongqin WU ; Hui DING ; Zhongxian LIAO ; Gen LI ; Hui ZHANG ; Hongwei MENG ; Changzi DENG ; Feng CHEN ; Na JIANG ; Jie QIN ; Guoping DONG ; Jinghua ZHANG ; Wei XI ; Haomin ZHANG ; Rong TANG ; Li LI ; Suzhen WANG ; Fen PAN ; Jing GAO ; Lu JIANG ; Hua FANG ; Zhilan LI ; Yiqun YUAN ; Guoqing WANG ; Yuanxia WANG ; Liping WANG
Chinese Journal of Infection and Chemotherapy 2024;24(4):402-409
Objective To monitor the antifungal resistance of clinical isolates of Candida spp.in the East China region.Methods MALDI-TOF MS or molecular methods were used to re-identify the strains collected from January 2018 to December 2022.Antifungal susceptibility testing was performed using the broth microdilution method.The susceptibility test results were interpreted according to the breakpoints of 2022 Clinical and Laboratory Standards Institute(CLSI)documents M27 M44s-Ed3 and M57s-Ed4.Results A total of 3 026 strains of Candida were collected,65.33%of which were isolated from sterile body sites,mainly from blood(38.86%)and pleural effusion/ascites(10.21%).The predominant species of Candida were Candida albicans(44.51%),followed by Candida parapsilosis complex(19.46%),Candida tropicalis(13.98%),Candida glabrata(10.34%),and other Candida species(0.79%).Candida albicans showed overall high susceptibility rates to the 10 antifungal drugs tested(the lowest rate being 93.62%).Only 2.97%of the strains showed dose-dependent susceptibility(SDD)to fluconazole.Candida parapsilosis complex had a SDD rate of 2.61%and a resistance rate of 9.42%to fluconazole,and susceptibility rates above 90%to other drugs.Candida glabrata had a SDD rate of 92.01%and a resistance rate of 7.99%to fluconazole,resistance rates of 32.27%and 48.24%to posaconazole and voriconazole non-wild-type strains(NWT),respectively,and susceptibility rates above 90%to other drugs.Candida tropicalis had resistance rates of 29.55%and 26.24%to fluconazole and voriconazole,respectively,resistance rates of 76.60%and 21.99%to posaconazole and echinocandins non-wild-type strains(NWT),and a resistance rate of 2.36%to echinocandins.Conclusions The prevalence and species distribution of Candida spp.in the East China region are consistent with previous domestic and international reports.Candida glabrata exhibits certain degree of resistance to fluconazole,while Candida tropicalis demonstrates higher resistance to triazole drugs.Additionally,echinocandins resistance has emerged in Candida albicans,Candida glabrata,Candida tropicalis,and Candida parapsilosis.
10.Effect of Chlorambucil Combined with Ibrutinib on Mantle Cell Lymphoma Cell Line Jeko-1 and Its Related Mechanism
Ni-Na CAI ; Wan-Yi LIU ; Zhi-Qiang LIU ; Jia-Hui GONG ; Yi-Ling LIN ; Ze-Chuan WANG ; Yue-Qin HUANG ; Jian-Xin GUO
Journal of Experimental Hematology 2024;32(1):132-137
Objective:To investigate the toxic effect of chlorambucil combined with ibrutinib on mantle cell lymphoma(MCL)cell line Jeko-1 and its related mechanism.Methods:The MCL cell line Jeko-1 was incubated with different concentrations of chlorambucil or ibrutinib or the combination of the two drugs,respectively.CCK-8 assay was used to detect the proliferation of the cells,and Western blot was used to measure the protein expression levels of BCL-2,caspase-3,PI3K,AKT and P-AKT.Results:After Jeko-1 cells were treated with chlorambucil(3.125,6.25,12.5,25,50 μmol/L)and ibrutinib(3.125,6.25,12.5,25,50 μmol/L)alone for 24,48,72h respectively,the cell proliferation was inhibited in a time-and dose-dependent manner.Moreover,the two drugs were applied in combination at low doses(single drug inhibition rate<50%),and the results showed that the combination of two drugs had a more significant inhibitory effect(all P<0.05).Compared with the control group,the apoptosis rate of the single drug group of chlorambucil(3.125,6.25,12.5,25,50 μmol/L)and ibutinib(3.125,6.25,12.5,25,50 μmol/L)was increased in a dose-dependent manner.The combination of the two drugs at low concentrations(3.125,6.25,12.5 μmol/L)could significantly increase the apoptosis rate compared with the corresponding concentration of single drug groups(all P<0.05).Compared with control group,the protein expression levels of caspase-3 in Jeko-l cells were upregulated,while the protein expression levels of BCL-2,PI3K,and p-AKT/AKT were downregulated after treatment with chlorambucil or ibrutinib alone.The combination of the two drugs could produce a synergistic effect on the expressions of the above-mentioned proteins,and the differences between the combination group and the single drug groups were statistically significant(all P<0.05).Conclusion:Chlorambucil and ibrutinib can promote the apoptosis of MCL cell line Jeko-1,and combined application of the two drugs shows a synergistic effect,the mechanism may be associated with the AKT-related signaling pathways.

Result Analysis
Print
Save
E-mail