1.Subchronic exposure to benzoapyrene results in lung tissue cell damage caused by ferroptosis in mice
Chaoli ZHOU ; Shihan DING ; Hui HE ; Zhirui MA ; Jie CHEN ; Xingdi GUO ; Yi LYU ; Jinping ZHENG
Journal of Environmental and Occupational Medicine 2025;42(8):971-977
Background Exposure to benzo[a]pyrene (BaP) may impair lung function through various mechanisms; however, it remains uncertain whether BaP induces ferroptosis in lung tissue cells, resulting in lung function impairment. Objective To investigate the ferroptosis of lung tissue cells triggered by subchronic BaP exposure in mice and its correlation with lung injury, and to explore the function of ferroptosis in BaP-induced lung tissue damage. Method Seventy-two healthy 3-weeks-old male C57BL/6J mice were acclimatized for 1 week and then randomly divided into six groups: control group (corn oil 10 mL·kg−1), low-dose BaP group (2.5 mg·kg−1), medium-dose BaP group (5 mg·kg−1), high-dose BaP group (10 mg·kg−1), BaP+ferrostatin-1 (Fer-1) group (10 mg·kg−1+1 mg·kg−1), and Fer-1 group (1 mg·kg−1), with 12 mice each group. Corn oil and BaP were administered via gavage every other day, followed by an intraperitoneal injection of Fer-1 the subsequent day, throughout a period of 90 d. Whole-body plethysmography was applied to detect lung function; hematoxylin-eosin staining (HE) and Masson staining were used to observe lung tissue injury and fibrosis; microscopy of alveolar epithelial cells was conducted to reveal mitochondrial morphology; biochemical assays were used to measure the content of tissue iron, malondialdehyde (MDA), and glutathione (GSH), as well as the activity of glutathione peroxidase (GSH-Px); Western blotting and real-time quantitative PCR (RT-qPCR) analyses were performed to reveal the protein and mRNA expression of ferroptosis markers. Results Compared to the control group, the high-dose BaP group showed a significant increase in expiration time (Te) (P<0.01), and a significant decrease in ratio rate of achieving peak expiratory flow (Rpef), tidal volume (TVb), peak inspiratory flow (PIF), minute volume (MVb), and peak expiratory flow (PEF) (P<0.05 or 0.01). Based on the results of HE and Masson staining, partial destruction of alveolar structures, thickening of alveolar walls, infiltration of inflammatory cells, significant thickening of tracheal walls and a large deposition of collagen fibers in lung tissue were observed in the medium- and high-dose BaP groups. By microscopy, the alveolar epithelial cells exposed to low-dose BaP showed condensed chromatin, and the mitochondria exposed to medium and high-dose BaP showed wrinkles, increased mitochondrial membrane density, and diminished mitochondrial cristae. Compared to the control group, in the medium- and high-dose BaP groups, the lung tissue iron content and the expression levels of ACSL4 protein and mRNA significantly elevated (P<0.01 or 0.05), while the mRNA expression level of SLC7A11 significantly decreased (P<0.05); in the high-dose BaP group, the MDA content, COX2 protein, and PTGS2 mRNA expression levels significantly increased (P<0.05 or 0.01), GSH content and GSH-Px activity, GPX4 protein and mRNA expression levels, and the expression level of SLC7A11 protein significantly decreased (P<0.01 or 0.05). The ferroptosis inhibitor Fer-1 markedly reversed respiratory function, morphology, mitochondrial alterations, and the aforementioned ferroptosis-related biochemical indicators. Conclusion Subchronic exposure to BaP can induce ferroptosis in mice lung tissue cells, resulting in compromised lung function.
2.Genetic diversity analysis and DNA fingerprinting of Artemisia argyi germplasm resources based on EST-SSR molecular markers.
Yu-Yang MA ; Chang-Jie CHEN ; Ming-Xing WANG ; Yan FANG ; Yu-Huan MIAO ; Da-Hui LIU
China Journal of Chinese Materia Medica 2025;50(9):2356-2364
This study investigates the genetic diversity and evolutionary relationships of different Artemisia argyi germplasm resources to provide a basis for germplasm identification, variety selection, and resource protection. A total of 192 germplasm resources of A. argyi were studied, and EST-based simple sequence repeat(EST-SSR) primers were designed based on transcriptomic data of A. argyi. Polymerase chain reaction(PCR) amplification was performed on these resources, followed by fluorescence capillary electrophoresis to detect genetic diversity and construct DNA fingerprints. From 197 pairs of primers designed, 28 pairs with polymorphic and clear bands were selected. A total of 278 alleles were detected, with an average of 9.900 0 alleles per primer pair and an average effective number of alleles of 1.407 2. The Shannon's diversity index(I) for the A. argyi germplasm resources ranged from 0.148 1 to 0.418 0, with an average of 0.255 7. The polymorphism information content(PIC) ranged from 0.454 5 to 0.878 0, with an average of 0.766 9, showing high polymorphism. Cluster analysis divided the A. argyi germplasm resources into three major groups: Group Ⅰ contained 136 germplasm samples, Group Ⅱ contained 45, and Group Ⅲ contained 11. Principal component analysis also divided the resources into three groups, which was generally consistent with the clustering results. Mantel test results showed that the genetic variation in A. argyi populations was to some extent influenced by geographic distance, but the effect was minimal. Structure analysis showed that 190 germplasm materials had Q≥ 0.6, indicating that these germplasm materials had a relatively homogeneous genetic origin. Furthermore, 8 core primer pairs were selected from the 28 designed primers, which could distinguish various germplasm types. Using these 8 core primers, DNA fingerprints for the 192 A. argyi germplasm resources were successfully constructed. EST-SSR molecular markers can be used to study the genetic diversity and phylogenetic relationships of A. argyi, providing theoretical support for the identification and molecular-assisted breeding of A. argyi germplasm resources.
Artemisia/classification*
;
Microsatellite Repeats
;
Genetic Variation
;
Expressed Sequence Tags
;
DNA Fingerprinting
;
Phylogeny
;
Polymorphism, Genetic
;
DNA, Plant/genetics*
;
Genetic Markers
3.Protocol for development of Guideline for Interventions on Cervical Spine Health.
Jing LI ; Guang-Qi LU ; Ming-Hui ZHUANG ; Xin-Yue SUN ; Ya-Kun LIU ; Ming-Ming MA ; Li-Guo ZHU ; Zhong-Shi LI ; Wei CHEN ; Ji-Ge DONG ; Le-Wei ZHANG ; Jie YU
China Journal of Orthopaedics and Traumatology 2025;38(10):1083-1088
Cervical spine health issues not only seriously affect patients' quality of life but also impose a heavy burden on the social healthcare system. Existing guidelines lack sufficient clinical guidance on lifestyle and work habits, such as exercise, posture, daily routine, and diet, making it difficult to meet practical needs. To address this, relying on the China Association of Chinese Medicine, Wangjing Hospital of China Academy of Chinese Medical Sciences took the lead and joined hands with more than ten institutions to form a multidisciplinary guideline development group. For the first time, the group developed the Guidelines for Cervical Spine Health Intervention based on evidence-based medicine methods, strictly following the standardized procedures outlined in the World Health Organization Handbook for Guideline Development and the Guiding Principles for the Formulation/Revision of Clinical Practice Guidelines in China (2022 Edition). This proposal systematically explains the methods and steps for developing the guideline, aiming to make the guideline development process scientific, standardized, and transparent.
Humans
;
Practice Guidelines as Topic/standards*
;
Cervical Vertebrae
;
China
4.Association between Organochlorine Exposures and Lung Functions Modified by Thyroid Hormones and Mediated by Inflammatory Factors among Healthy Older Adults.
Xiao Jie GUO ; Hui Min REN ; Ji Ran ZHANG ; Xiao MA ; Shi Lu TONG ; Song TANG ; Chen MAO ; Xiao Ming SHI
Biomedical and Environmental Sciences 2025;38(2):144-153
OBJECTIVE:
To examine the mechanistic of organochlorine-associated changes in lung function.
METHODS:
This study investigated 76 healthy older adults in Jinan, Shandong Province, over a five-month period. Personal exposure to organochlorines was quantified using wearable passive samplers, while inflammatory factors and thyroid hormones were analyzed from blood samples. Participants' lung function was evaluated. After stratifying participants according to their thyroid hormone levels, we analyzed the differential effects of organochlorine exposure on lung function and inflammatory factors across the low and high thyroid hormone groups. Mediation analysis was further conducted to elucidate the relationships among organochlorine exposures, inflammatory factors, and lung function.
RESULTS:
Bis (2-chloro-1-methylethyl) ether (BCIE), was negatively associated with forced vital capacity (FVC, -2.05%, 95% CI: -3.11% to -0.97%), and associated with changes in inflammatory factors such as interleukin (IL)-2, IL-7, IL-8, and IL-13 in the low thyroid hormone group. The mediation analysis indicated a mediating effect of IL-2 (15.63%, 95% CI: 0.91% to 44.64%) and IL-13 (13.94%, 95% CI: 0.52% to 41.07%) in the association between BCIE exposure and FVC.
CONCLUSION
Lung function and inflammatory factors exhibited an increased sensitivity to organochlorine exposure at lower thyroid hormone levels, with inflammatory factors potentially mediating the adverse effects of organochlorines on lung function.
Environmental Exposure
;
Hydrocarbons, Chlorinated/metabolism*
;
China
;
Ethyl Ethers/metabolism*
;
Environmental Monitoring
;
Thyroid Hormones/blood*
;
Lung/physiology*
;
Inhalation Exposure/statistics & numerical data*
;
Air Pollution/statistics & numerical data*
;
Air Pollutants/metabolism*
;
Humans
;
Male
;
Female
;
Middle Aged
;
Aged
5.Cloning and interacted protein identification of AP1 homologous gene from Lonicera macranthoides
Ya-xin YU ; Li-jun LONG ; Chang-zhu LI ; Hui-jie ZENG ; Zhong-quan QIAO ; Si-si LIU ; Ying-zi MA
Acta Pharmaceutica Sinica 2024;59(10):2880-2888
The
6.The taste correction process of ibuprofen oral solution based on the combination of electronic tongue technology and artificial taste comprehensive evaluation
Rui YUAN ; Yun-ping QU ; Yan WANG ; Ya-xuan ZHANG ; Wan-ling ZHONG ; Xiao-yu FAN ; Hui-juan SHEN ; Yun-nan MA ; Jin-hong YE ; Jie BAI ; Shou-ying DU
Acta Pharmaceutica Sinica 2024;59(8):2404-2411
This experiment aims to study the taste-masking effects of different kinds of corrigent used individually and in combination on ibuprofen oral solution, in order to optimize the taste-masking formulation. Firstly, a wide range of corrigent and the mass fractions were extensively screened using electronic tongue technology. Subsequently, a combination of sensory evaluation, analytic hierarchy process (AHP)-fuzzy mathematics evaluation, and Box-Behnken experimental design were employed to comprehensively assess the taste-masking effects of different combinations of corrigent on ibuprofen oral solution, optimize the taste-masking formulation, and validate the results. The study received ethical approval from the Review Committee of the Beijing University of Chinese Medicine (ethical code: 2024BZYLL0102). The results showed that corrigent fractions and types were screened separately through single-factor experiments. Subsequently, a Box-Behnken response surface design combined with AHP and fuzzy mathematics evaluation was used to fit a functional model:
7.Cloning and interacted protein identification of AGL12 gene from Lonicera macranthoides
Li-jun LONG ; Hui-jie ZENG ; Zhong-quan QIAO ; Xiao-ming WANG ; Chang-zhu LI ; Si-si LIU ; Ying-zi MA
Acta Pharmaceutica Sinica 2024;59(5):1458-1466
MADS-box protein family are important transcriptional regulatory factors in plant growth and development. The
8.Pharmacokinetics of JS026 and JS026-JS016 for single intravenous administration in healthy volunteers
Yan TIAN ; Hui-Jing YE ; Jing-Jing WANG ; Nan-Yang LI ; Juan MA ; Xi TAN ; Fan WU ; Jie WANG ; Shu-Yan YU ; Xiao-Jie WU ; Jin-Jie HE ; Jing ZHANG ; Wen-Hong ZHANG
The Chinese Journal of Clinical Pharmacology 2024;40(15):2251-2255
Objective To evaluate tolerability,safety and pharmacokinetics of JS026 and JS026-JS016 single dose intravenous infusion in healthy adults.Methods This phase 1,randomized,double-blind,placebo-controlled,dose-escalation study totally included 48 participants:32 healthy subjects were enrolled in JS026 single intravenous infusion groups and 16 healthy subjects were enrolled in JS026-JS016 groups.JS026 was sequentially administered from low dose to high dose(30-1 000 mg),with intravenous infusion of JS026 or placebo in JS026 single-dose groups,and intravenous infusion of JS026-JS016 or placebo in the combination drug groups.Blood was collected according to the time point designed for trial.Serum concentrations of JS026 and JS016 were determined by enzyme linked immunosorbnent assay(ELISA),and pharmacokinetics parameters were calculated by WinNonlin 8.2.The power model method was used to evaluate the linear analysis of dose and drug exposure.Results 47 subjects completed trial and 1 subject lost to follow-up.After a single intravenous injection of JS026 of 30 mg,100 mg,300 mg,600 mg,and 1 000 mg,mean Cmax were(9.47±1.53),(33.20±4.95),(96.10±13.70),(177.00±22.20)and(353.00±56.70)μg·mL-1,respectively;mean AUC0-∞ were(4 225.00±607.00),(1.78 × 104±3 268.00),(5.83 × 104±1 038.00),(1.07 × 105±152.00),(1.66 × 105±327.00)μg·h·mL-1,respectively;mean t1/2 of JS026 were 563-709 h.The Cmax and AUC0-∞ of JS026 were basically similar alone or in combination with JS016.The results of Power model showed that Cmax and AUC0-∞ increased approximately linearly with the increasing dose of JS026.Treatment emergent adverse event was not increasing when dose increased and most of adverse event associated with drugs were abnormal on laboratory tests and haematuria,thus JS026 and JS016 was well tolerated in all groups.Conclusion The single intravenous infusion of JS026 can almost be thought to be a linear relationship between the doses and drug serum exposure.JS016 had no significant effect on serum concentration of JS026 and JS026 was well tolerated and safe in healthy subjects within 30-1 000 mg.
9.Hypericin inhibits the expression of NLRP3 in microglia of Parkinson's disease mice and alleviates the damage of DA-ergic neurons
Li-Shan FAN ; Jia ZHANG ; Si-Xiang NIU ; Qi XIAO ; Hui-Jie FAN ; Lei XU ; Li-Xia YANG ; Lu JIA ; Shao-Chen QIN ; Bao-Guo XIAO ; Cun-Gen MA ; Zhi CHAI
The Chinese Journal of Clinical Pharmacology 2024;40(17):2523-2527
Objective To observe the intervention effect of hypericin(HYP)on 1-methyl-4-phenyl-1,2,3,6-tetrahydropyridine(MPTP)-induced Parkinson's disease(PD)mice model and its mechanism.Methods Thirty C57BL/6 mice were randomly divided into normal,model and experimental groups with 10 mice per group.PD mouse model was established after 7 days of intraperitoneal injection of MPTP,and drug intervention was carried out from the first day of modeling.Normal group and model group were intraperitoneally injected with 500 μL·kg·d-1 0.9%NaCl.The experimental group was intraperitoneally injected with 25 mg·kg·d-1 HYP.The three groups of rats were given the drug once each time for 14 days.The expression levels of tyrosine hydroxylase(TH),Nod-like receptor thermal protein domain protein 3(NLRP3)and ionized calcium binding adapter molecule 1(Iba1)in the striatum of nigra were detected by Western blot.Results The climbing time of normal,model and experimental groups was(5.35±0.43),(9.71±1.19)and(8.07±0.34)s;suspension scores were(2.92±0.15),(1.38±0.28)and(1.96±0.28)points;the relative expression levels of TH protein were 1.04±0.06,0.51±0.09 and 0.75±0.07;the relative expression levels of NLRP3 protein were 0.51±0.03,1.00±0.04 and 0.77±0.06;the relative expression levels of Iba1 protein were 0.68±0.10,1.30±0.28 and 0.89±0.05,respectively.The above indexes in the model group were statistically significant compared with the experimental group and the normal group(all P<0.01).Conclusion HYP plays a therapeutic role in PD by inhibiting the expression of NLRP3 inflammasome in PD mice.
10.Expert consensus on digital intraoral scanning technology
Jie YOU ; Wenjuan YAN ; Liting LIN ; Wen-Zhen GU ; Yarong HOU ; Wei XIAO ; Hui YAO ; Yaner LI ; Lihui MA ; Ruini ZHAO ; Junqi QIU ; Jianzhang LIU ; Yi ZHOU
Journal of Prevention and Treatment for Stomatological Diseases 2024;32(8):569-577
Digital intraoral scanning is a hot topic in the field of oral digital technology.In recent years,digital intra-oral scanning has gradually become the mainstream technology in orthodontics,prosthodontics,and implant dentistry.The precision of digital intraoral scanning and the accuracy and stitching of data collection are the keys to the success of the impression.However,the operators are less familiar with the intraoral scanning characteristics,imaging process-ing,operator scanning method,oral tissue specificity of the scanned object,and restoration design.Thus far,no unified standard and consensus on digital intraoral scanning technology has been achieved at home or abroad.To deal with the problems encountered in oral scanning and improve the quality of digital scanning,we collected common expert opin-ions and sought to expound the causes of scanning errors and countermeasures by summarizing the existing evidence.We also describe the scanning strategies under different oral impression requirements.The expert consensus is that due to various factors affecting the accuracy of digital intraoral scanning and the reproducibility of scanned images,adopting the correct scanning trajectory can shorten clinical operation time and improve scanning accuracy.The scanning trajec-tories mainly include the E-shaped,segmented,and S-shaped methods.When performing fixed denture restoration,it is recommended to first scan the abutment and adjacent teeth.When performing fixed denture restoration,it is recommend-ed to scan the abutment and adjacent teeth first.Then the cavity in the abutment area is excavated.Lastly,the cavity gap was scanned after completing the abutment preparation.This method not only meets clinical needs but also achieves the most reliable accuracy.When performing full denture restoration in edentulous jaws,setting markers on the mucosal tissue at the bottom of the alveolar ridge,simultaneously capturing images of the vestibular area,using different types of scanning paths such as Z-shaped,S-shaped,buccal-palatal and palatal-buccal pathways,segmented scanning of dental arches,and other strategies can reduce scanning errors and improve image stitching and overlap.For implant restora-tion,when a single crown restoration is supported by implants and a small span upper structure restoration,it is recom-mended to first pre-scan the required dental arch.Then the cavity in the abutment area is excavated.Lastly,scanning the cavity gap after installing the implant scanning rod.When repairing a bone level implant crown,an improved indi-rect scanning method can be used.The scanning process includes three steps:First,the temporary restoration,adjacent teeth,and gingival tissue in the mouth are scanned;second,the entire dental arch is scanned after installing a standard scanning rod on the implant;and third,the temporary restoration outside the mouth is scanned to obtain the three-di-mensional shape of the gingival contour of the implant neck,thereby increasing the stability of soft tissue scanning around the implant and improving scanning restoration.For dental implant fixed bridge repair with missing teeth,the mobility of the mucosa increases the difficulty of scanning,making it difficult for scanners to distinguish scanning rods of the same shape and size,which can easily cause image stacking errors.Higher accuracy of digital implant impres-sions can be achieved by changing the geometric shape of the scanning rods to change the optical curvature radius.The consensus confirms that as the range of scanned dental arches and the number of data concatenations increases,the scanning accuracy decreases accordingly,especially when performing full mouth implant restoration impressions.The difficulty of image stitching processing can easily be increased by the presence of unstable and uneven mucosal mor-phology inside the mouth and the lack of relatively obvious and fixed reference objects,which results in insufficient ac-curacy.When designing restorations of this type,it is advisable to carefully choose digital intraoral scanning methods to obtain model data.It is not recommended to use digital impressions when there are more than five missing teeth.


Result Analysis
Print
Save
E-mail