1.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
2.Effect of a novel cryoprotectant in tissues and cells
Qingfang WANG ; Fen ZHANG ; Guangping CHANG ; Zihan LI ; Lan XING ; Hao PENG ; Xiuping ZENG ; Guiqiang ZHONG ; Hui CHEN ; Bo LIU ; Zhenyu LIU ; Xiao LIANG
Chinese Journal of Tissue Engineering Research 2025;29(36):7816-7826
BACKGROUND:The cryopreservation technology enables tissues/cells to be stored for a long time in a low-temperature environment while maintaining the integrity of their activity and function,which is of great significance for the construction of cell therapy,tissue engineering and biological sample banks.Cryoprotective agents often contain dimethyl sulfoxide and serum.To avoid the toxic side effects of dimethyl sulfoxide,the complexity of serum components and immune responses,although some finished cryoprotective agents have been marketed,they are faced with many difficulties such as high cost and limited application.Therefore,there is an urgent need to develop a cryoprotective agent with clear components and the ability to solve the above problems.OBJECTIVE:To evaluate the effects of a novel cryoprotectant on cryopreservation efficiency of different tissue and cell sources.METHODS:By applying the novel cryoprotectant as an experimental group with the commercially available and widely used cryoprotectant(control group)to umbilical cord Wharton's jelly tissue,umbilical cord mesenchymal stem cells,umbilical cord blood/peripheral blood mononuclear cells,NK and CIK cells,comparative analyses were conducted in terms of cell morphology,number,viability,surface markers,differentiation potential,and cell-killing toxicity assay before cryopreservation and after resuscitation thawing.We confirmed the cryopreservation effect of the new cryoprotectant and its potential application value.RESULTS AND CONCLUSION:(1)The novel cryoprotectant facilitated the normal growth of cryopreserved Wharton's jelly tissue upon recovery,exhibiting mesenchymal stem cell morphology.No significant differences were observed between the experimental and control groups in terms of cell recovery rate,surface markers,and differentiation potential.(2)There was no significant difference in the number and viability of cells between the experimental group and the control group after cryopreservation of cord blood/peripheral blood mononuclear cells,and the cryo-resuscitated cell numbers and viability of derived NK cells/CIK cells did not show significant difference between the experimental and control groups.(3)For NK cells derived and differentiated from cord blood/peripheral blood mononuclear cells,there was no significant difference in the proportion of CD56+CD16+cell subpopulations between the experimental group and the control group.For CIK cells derived and differentiated from cord blood/peripheral blood mononuclear cells,there was no significant difference in the proportions of CD3+CD8+and CD3+CD56+cell subpopulations between the experimental group and the control group.(4)In terms of cytotoxicity testing,when the effective-target ratio of immune cells and melanoma cell line Mel624 was 20:1,whether it was NK cells/CIK cells derived from cord blood or peripheral blood mononuclear cells,there was no significant difference in the tumoricidal activity of cells between the experimental group and the control group.These findings suggest that the novel cryoprotectant can replace existing commercially available and widely used cryoprotectants,and is applicable to Wharton's jelly tissue,umbilical cord mesenchymal stem cells,umbilical cord blood/peripheral blood mononuclear cells,as well as NK and CIK cells,providing a solid technical foundation for the scaling,standardization,and commercialization of universal cryoprotectants.
3.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
4.The influence of two-way referral model on treatment and prognosis of patients with chronic heart failure
Yijun SUN ; Xinyu ZHANG ; Yue HU ; Zongwei LIN ; Jie XIAO ; Peng LI ; Xin ZHAO ; Huafang ZHANG ; Bo QIN ; Dequan JIA ; Tao ZHANG ; Jian MA ; Hongping CHEN ; Chunju ZHANG ; Xinwei GENG ; Kaiyan ZHANG ; Man ZHENG ; Fenglei ZHANG ; Yan LANG ; Hegong HOU ; Peng LIU ; Haifeng JIA ; Jianjun LU ; Kai ZHAO ; Hui ZHAO ; Jiechang XU ; Mi ZHANG ; Xiuxin LI ; Dongxia ZHANG ; Lin ZHONG ; Hui ZHAO ; Fangfang LIU ; Yan LIU ; Dongxia MIAO ; Chengwei WANG ; Hui ZHANG ; Chen WANG ; Fen WANG ; Xuejuan ZHANG ; Huixia LYU ; Xiaoping JI
Chinese Journal of Cardiology 2025;53(11):1244-1253
Objective:To explore the impact of the two-way referral model on compliance and prognosis in patients with heart failure.Methods:This bidirectional cohort study enrolled chronic heart failure (CHF) patients treated at Qilu Hospital of Shandong University or designated primary hospitals between March 2018 and March 2022. Patients were categorized into two groups based on referral status: two-way referral group (participating in the referral model with≥1 follow-up visit at primary hospitals) and the core hospital group (receiving treatment and follow-up exclusively at Qilu Hospital). Baseline clinical characteristics were collected and compared between groups. Patients underwent followed-up, with primary endpoints including follow-up rate, drug (β-blockers, angiotension converting enzyme inhibitor (ACEI)/angiotensin Ⅱ receptor blockers (ARB)/angiotensin receptor-neprilysin inhibitor (ARNI), sodium-glucose cotransporter 2 inhibitors and mineralocorticoid receptor antagonists) utilization rate and target dose achievement rate. Secondary endpoints encompassed changes from baseline in left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDd), and N-terminal pro-brain natriuretic peptide (NT-proBNP), plus cardiovascular mortality and heart failure rehospitalization. Generalized linear mixed models analyzed longitudinal trends in LVEF, LVEDd, and NT-proBNP levels. Kaplan-Meier curves and Cox regression evaluated LVEF recovery rates, supplemented by subgroup analyses. Multivariate logistic regression was used to identify factors influencing target dose achievement rate for β-blockers and ACEI/ARB/ARNI therapies in CHF patients.Results:A total of 357 patients were enrolled, aged 53 (41, 63) years, including 256 males (71.7%). 157 patients were in the two-way referral group and 200 patients in the core hospital-treated group. Compared with the core hospital-treated group, the two-way referral group had lower baseline LVEF (28 (22, 34)% vs. 31 (23, 36)%, P=0.021) and systolic blood pressure (116 (104, 125) mmHg vs. 121 (109, 134) mmHg (1 mmHg=0.133 kPa), P=0.010). The 12-month follow-up rate of the two-way referral group was higher than the core hospital-treated group (73.8% vs. 56.0%, P=0.004). No significant between-group differences were observed in drug utilization rate of β-blockers, ACEI/ARB/ARNI, or sodium-glucose cotransporter 2 inhibitors during follow-up (all P>0.05), while mineralocorticoid receptor antagonists use showed a declining trend in both groups. Although the core hospital-treated group had higher target dose achievement rates for β-blockers (65.4% vs. 49.3%, P=0.042) and ACEI/ARB/ARNI (79.8% vs. 65.8%, P=0.046) than the two-way referral group, multivariate logistic regression indicated that the two-way referral model was not a negative predictor for these outcomes (all P>0.05). Both groups showed improved NT-proBNP, LVEDd, and LVEF from baseline (all P<0.001) with no significant difference in trends between groups (all P>0.05). There was no significant difference in the composite incidence (7.6% vs. 6.5%, P=0.674) and cumulative incidence (log-rank P=0.684) of cardiovascular death and heart failure rehospitalization at 12 months between two groups. Conclusion:The two-way referral model demonstrates advantages in improving medication adherence, drug utilization rates, and targetdoseachievement rates among CHF patients. This model not only promotes cardiac functional recovery but also reduces risks of cardiovascular mortality and heart failure rehospitalization, achieving comparable therapeutic and management outcomes to those observed in core hospital-treated patients.
5.Zhu-Tokita-Takenouchi-Kim syndrome in a neonate.
Wei-Na LIU ; Ya-Lei PI ; Xing-Yu BAI ; Hui-Fen CHEN
Chinese Journal of Contemporary Pediatrics 2025;27(3):373-376
The patient is a male neonate born at term. He was admitted 16 minutes after birth due to stridor and inspiratory respiratory distress. Physical examination revealed a cleft palate, and a grade II systolic ejection murmur was audible at the left sternal border. Whole exome sequencing identified a heterozygous variant in the SON gene, c.5753-5756del (p.Val1918GlufsTer87), which was absent in either parent, indicating a de novo mutation. According to the guidelines of the American College of Medical Genetics and Genomics, this was classified as a "pathogenic variant" leading to a diagnosis of Zhu-Tokita-Takenouchi-Kim (ZTTK) syndrome. Upon admission, symptomatic supportive treatment was provided. Follow-up at the age of 8 months revealed persistent stridor; the infant could only consume small amounts of milk and was unable to sit steadily. This patient represents the youngest reported case to date, and his symptoms expand the clinical spectrum of the disease, providing valuable insights for clinical diagnosis and treatment.
Humans
;
Infant, Newborn
;
Male
;
Minor Histocompatibility Antigens/genetics*
;
DNA-Binding Proteins/genetics*
;
Rare Diseases/genetics*
;
Neurodevelopmental Disorders/genetics*
6.Colon Dialysis with Yishen Decoction Improves Autophagy Disorder in Intestinal Mucosal Epithelial Cells of Chronic Renal Failure by Regulating SIRT1 Pathway.
Yan-Jun FAN ; Jing-Ai FANG ; Su-Fen LI ; Ting LIU ; Wen-Yuan LIU ; Ya-Ling HU ; Rui-Hua WANG ; Hui LI ; Da-Lin SUN ; Guang ZHANG ; Zi-Yuan ZHANG
Chinese journal of integrative medicine 2025;31(10):899-907
OBJECTIVE:
To explore the mechanism of colon dialysis with Yishen Decoction (YS) in improving the autophagy disorder of intestinal epithelial cells in chronic renal failure (CRF) in vivo and in vitro.
METHODS:
Thirty male SD rats were randomly divided into normal, CRF, and colonic dialysis with YS groups by a random number table method (n=10). The CRF model was established by orally gavage of adenine 200 mg/(kg•d) for 4 weeks. CRF rats in the YS group were treated with colonic dialysis using YS 20 g/(kg•d) for 14 consecutive days. The serum creatinine (SCr) and urea nitrogen (BUN) levels were detected by enzyme-linked immunosorbent assay. Pathological changes of kidney and colon tissues were observed by hematoxylin and eosin staining. Autophagosome changes in colonic epithelial cells was observed with electron microscopy. In vitro experiments, human colon cancer epithelial cells (T84) were cultured and divided into normal, urea model (74U), YS colon dialysis, autophagy activator rapamycin (Ra), autophagy inhibitor 3-methyladenine (3-MA), and SIRT1 activator resveratrol (Re) groups. RT-PCR and Western blot were used to detect the mRNA and protein expressions of zonula occludens-1 (ZO-1), Claudin-1, silent information regulator sirtuin 1 (SIRT1), LC3, and Beclin-1 both in vitro and in vivo.
RESULTS:
Colonic dialysis with YS decreased SCr and BUN levels in CRF rats (P<0.05), and alleviated the pathological changes of renal and colon tissues. Expressions of SIRT1, ZO-1, Claudin-1, Beclin-1, and LC3II/I were increased in the YS group compared with the CRF group in vivo (P<0.05). In in vitro study, compared with normal group, the expressions of SIRT1, ZO-1, and Claudin-1 were decreased, and expressions of Beclin-1, and LC3II/I were increased in the 74U group (P<0.05). Compared with the 74U group, expressions of SIRT1, ZO-1, and Claudin-1 were increased, whereas Beclin-1, and LC3II/I were decreased in the YS group (P<0.05). The treatment of 3-MA and rapamycin regulated autophagy and the expression of SIRT1. SIRT1 activator intervention up-regulated autophagy as well as the expressions of ZO-1 and Claudin-1 compared with the 74U group (P<0.05).
CONCLUSION
Colonic dialysis with YS could improve autophagy disorder and repair CRF intestinal mucosal barrier injury by regulating SIRT1 expression in intestinal epithelial cells.
Animals
;
Sirtuin 1/metabolism*
;
Drugs, Chinese Herbal/therapeutic use*
;
Autophagy/drug effects*
;
Male
;
Intestinal Mucosa/drug effects*
;
Rats, Sprague-Dawley
;
Epithelial Cells/metabolism*
;
Colon/drug effects*
;
Humans
;
Kidney Failure, Chronic/drug therapy*
;
Signal Transduction/drug effects*
;
Renal Dialysis
;
Rats
;
Kidney/drug effects*
7.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
8.The influence of two-way referral model on treatment and prognosis of patients with chronic heart failure
Yijun SUN ; Xinyu ZHANG ; Yue HU ; Zongwei LIN ; Jie XIAO ; Peng LI ; Xin ZHAO ; Huafang ZHANG ; Bo QIN ; Dequan JIA ; Tao ZHANG ; Jian MA ; Hongping CHEN ; Chunju ZHANG ; Xinwei GENG ; Kaiyan ZHANG ; Man ZHENG ; Fenglei ZHANG ; Yan LANG ; Hegong HOU ; Peng LIU ; Haifeng JIA ; Jianjun LU ; Kai ZHAO ; Hui ZHAO ; Jiechang XU ; Mi ZHANG ; Xiuxin LI ; Dongxia ZHANG ; Lin ZHONG ; Hui ZHAO ; Fangfang LIU ; Yan LIU ; Dongxia MIAO ; Chengwei WANG ; Hui ZHANG ; Chen WANG ; Fen WANG ; Xuejuan ZHANG ; Huixia LYU ; Xiaoping JI
Chinese Journal of Cardiology 2025;53(11):1244-1253
Objective:To explore the impact of the two-way referral model on compliance and prognosis in patients with heart failure.Methods:This bidirectional cohort study enrolled chronic heart failure (CHF) patients treated at Qilu Hospital of Shandong University or designated primary hospitals between March 2018 and March 2022. Patients were categorized into two groups based on referral status: two-way referral group (participating in the referral model with≥1 follow-up visit at primary hospitals) and the core hospital group (receiving treatment and follow-up exclusively at Qilu Hospital). Baseline clinical characteristics were collected and compared between groups. Patients underwent followed-up, with primary endpoints including follow-up rate, drug (β-blockers, angiotension converting enzyme inhibitor (ACEI)/angiotensin Ⅱ receptor blockers (ARB)/angiotensin receptor-neprilysin inhibitor (ARNI), sodium-glucose cotransporter 2 inhibitors and mineralocorticoid receptor antagonists) utilization rate and target dose achievement rate. Secondary endpoints encompassed changes from baseline in left ventricular ejection fraction (LVEF), left ventricular end-diastolic diameter (LVEDd), and N-terminal pro-brain natriuretic peptide (NT-proBNP), plus cardiovascular mortality and heart failure rehospitalization. Generalized linear mixed models analyzed longitudinal trends in LVEF, LVEDd, and NT-proBNP levels. Kaplan-Meier curves and Cox regression evaluated LVEF recovery rates, supplemented by subgroup analyses. Multivariate logistic regression was used to identify factors influencing target dose achievement rate for β-blockers and ACEI/ARB/ARNI therapies in CHF patients.Results:A total of 357 patients were enrolled, aged 53 (41, 63) years, including 256 males (71.7%). 157 patients were in the two-way referral group and 200 patients in the core hospital-treated group. Compared with the core hospital-treated group, the two-way referral group had lower baseline LVEF (28 (22, 34)% vs. 31 (23, 36)%, P=0.021) and systolic blood pressure (116 (104, 125) mmHg vs. 121 (109, 134) mmHg (1 mmHg=0.133 kPa), P=0.010). The 12-month follow-up rate of the two-way referral group was higher than the core hospital-treated group (73.8% vs. 56.0%, P=0.004). No significant between-group differences were observed in drug utilization rate of β-blockers, ACEI/ARB/ARNI, or sodium-glucose cotransporter 2 inhibitors during follow-up (all P>0.05), while mineralocorticoid receptor antagonists use showed a declining trend in both groups. Although the core hospital-treated group had higher target dose achievement rates for β-blockers (65.4% vs. 49.3%, P=0.042) and ACEI/ARB/ARNI (79.8% vs. 65.8%, P=0.046) than the two-way referral group, multivariate logistic regression indicated that the two-way referral model was not a negative predictor for these outcomes (all P>0.05). Both groups showed improved NT-proBNP, LVEDd, and LVEF from baseline (all P<0.001) with no significant difference in trends between groups (all P>0.05). There was no significant difference in the composite incidence (7.6% vs. 6.5%, P=0.674) and cumulative incidence (log-rank P=0.684) of cardiovascular death and heart failure rehospitalization at 12 months between two groups. Conclusion:The two-way referral model demonstrates advantages in improving medication adherence, drug utilization rates, and targetdoseachievement rates among CHF patients. This model not only promotes cardiac functional recovery but also reduces risks of cardiovascular mortality and heart failure rehospitalization, achieving comparable therapeutic and management outcomes to those observed in core hospital-treated patients.
9.Effect of a novel cryoprotectant in tissues and cells
Qingfang WANG ; Fen ZHANG ; Guangping CHANG ; Zihan LI ; Lan XING ; Hao PENG ; Xiuping ZENG ; Guiqiang ZHONG ; Hui CHEN ; Bo LIU ; Zhenyu LIU ; Xiao LIANG
Chinese Journal of Tissue Engineering Research 2025;29(36):7816-7826
BACKGROUND:The cryopreservation technology enables tissues/cells to be stored for a long time in a low-temperature environment while maintaining the integrity of their activity and function,which is of great significance for the construction of cell therapy,tissue engineering and biological sample banks.Cryoprotective agents often contain dimethyl sulfoxide and serum.To avoid the toxic side effects of dimethyl sulfoxide,the complexity of serum components and immune responses,although some finished cryoprotective agents have been marketed,they are faced with many difficulties such as high cost and limited application.Therefore,there is an urgent need to develop a cryoprotective agent with clear components and the ability to solve the above problems.OBJECTIVE:To evaluate the effects of a novel cryoprotectant on cryopreservation efficiency of different tissue and cell sources.METHODS:By applying the novel cryoprotectant as an experimental group with the commercially available and widely used cryoprotectant(control group)to umbilical cord Wharton's jelly tissue,umbilical cord mesenchymal stem cells,umbilical cord blood/peripheral blood mononuclear cells,NK and CIK cells,comparative analyses were conducted in terms of cell morphology,number,viability,surface markers,differentiation potential,and cell-killing toxicity assay before cryopreservation and after resuscitation thawing.We confirmed the cryopreservation effect of the new cryoprotectant and its potential application value.RESULTS AND CONCLUSION:(1)The novel cryoprotectant facilitated the normal growth of cryopreserved Wharton's jelly tissue upon recovery,exhibiting mesenchymal stem cell morphology.No significant differences were observed between the experimental and control groups in terms of cell recovery rate,surface markers,and differentiation potential.(2)There was no significant difference in the number and viability of cells between the experimental group and the control group after cryopreservation of cord blood/peripheral blood mononuclear cells,and the cryo-resuscitated cell numbers and viability of derived NK cells/CIK cells did not show significant difference between the experimental and control groups.(3)For NK cells derived and differentiated from cord blood/peripheral blood mononuclear cells,there was no significant difference in the proportion of CD56+CD16+cell subpopulations between the experimental group and the control group.For CIK cells derived and differentiated from cord blood/peripheral blood mononuclear cells,there was no significant difference in the proportions of CD3+CD8+and CD3+CD56+cell subpopulations between the experimental group and the control group.(4)In terms of cytotoxicity testing,when the effective-target ratio of immune cells and melanoma cell line Mel624 was 20:1,whether it was NK cells/CIK cells derived from cord blood or peripheral blood mononuclear cells,there was no significant difference in the tumoricidal activity of cells between the experimental group and the control group.These findings suggest that the novel cryoprotectant can replace existing commercially available and widely used cryoprotectants,and is applicable to Wharton's jelly tissue,umbilical cord mesenchymal stem cells,umbilical cord blood/peripheral blood mononuclear cells,as well as NK and CIK cells,providing a solid technical foundation for the scaling,standardization,and commercialization of universal cryoprotectants.
10.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]

Result Analysis
Print
Save
E-mail