1.Evaluation of inner ear malformation based on high-resolution CT and MRI.
Liangliang LIU ; Kung ZHANG ; Bing WANG ; Qi YANG ; Lei XU ; Yan HAO ; Hui XU
Journal of Clinical Otorhinolaryngology Head and Neck Surgery 2025;39(1):47-56
Objective:To explore the value of high resolution computed tomography(HRCT) combined with Magnetic Resonance Imaging(MRI) in the diagnosis of inner ear malformation. Methods:HRCT and MRI data of 82 patients with inner ear malformations were analyzed retrospectively. HRCT MPR and CPR reconstruction of the inner ear structure, facial nerve canal and oblique sagittal MRI reconstruction of the internal auditory canal were performed. The inner ear malformations were classified, the conditions of facial nerve canal and cochlear nerve were evaluated. The association between inner ear malformation and cochlear nerve dysplasia were analyzed by Chi-square test with continuity correction. Results:Among the 82 patients with inner ear malformations,there were 49 cases of bilateral symmetry, 11 cases of bilateral asymmetry and 22 cases of unilateral inner ear malformations. Respectively, the most prevalent types were IP-Ⅱ(42.96%), dilatation of atrium aqueduct(18.31%) and malformations of atrium and semicircular canal 19.72%. Out of 50 cases of cochlear malformations,only 3 were isolated cochlear malformations, and the rest were accompanied by other malformations of varying degrees. In the 67 ears examined by MRI, 26(38.81%) had cochlear nerve deficiency(CND), and the incidence of CND varied with different types of inner ear malformations. Out of 142 ears, 28(19.72%) had abnormalities of the facial nerve canal. Conclusion:HRCT combined with MRI can accurately distinguish the types of inner ear malformation and effectively evaluate the facial nerve canal and cochlear nerve, and further provides the important finger and Guide value for the clinician to formulate the reasonable treatment and the operation plan.
Humans
;
Ear, Inner/diagnostic imaging*
;
Magnetic Resonance Imaging/methods*
;
Retrospective Studies
;
Female
;
Male
;
Tomography, X-Ray Computed/methods*
;
Child
;
Adolescent
;
Adult
;
Child, Preschool
;
Cochlear Nerve/diagnostic imaging*
;
Facial Nerve/abnormalities*
;
Cochlea/abnormalities*
;
Infant
;
Young Adult
2.Criteria and prognostic models for patients with hepatocellular carcinoma undergoing liver transplantation
Meng SHA ; Jun WANG ; Jie CAO ; Zhi-Hui ZOU ; Xiao-ye QU ; Zhi-feng XI ; Chuan SHEN ; Ying TONG ; Jian-jun ZHANG ; Seogsong JEONG ; Qiang XIA
Clinical and Molecular Hepatology 2025;31(Suppl):S285-S300
Hepatocellular carcinoma (HCC) is a leading cause of cancer-associated death globally. Liver transplantation (LT) has emerged as a key treatment for patients with HCC, and the Milan criteria have been adopted as the cornerstone of the selection policy. To allow more patients to benefit from LT, a number of expanded criteria have been proposed, many of which use radiologic morphological characteristics with larger and more tumors as surrogates to predict outcomes. Other groups developed indices incorporating biological variables and dynamic markers of response to locoregional treatment. These expanded selection criteria achieved satisfactory results with limited liver supplies. In addition, a number of prognostic models have been developed using clinicopathological characteristics, imaging radiomics features, genetic data, and advanced techniques such as artificial intelligence. These models could improve prognostic estimation, establish surveillance strategies, and bolster long-term outcomes in patients with HCC. In this study, we reviewed the latest findings and achievements regarding the selection criteria and post-transplant prognostic models for LT in patients with HCC.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Association between pubertal timing and depressive symptoms among high school students in Suzhou City
HU Jiale, ZHANG Liye, LING Ruizhe, HAN Di, WANG Xi, HU Jia, SHEN Hui
Chinese Journal of School Health 2025;46(10):1469-1473
Objective:
To investigate the relationship between pubertal timing and depressive symptoms among high school students in Suzhou, so as to provide scientific evidence for promoting adolescents mental health.
Methods:
From October 2023 to January 2024, 3 369 students were selected from 20 high schools in Suzhou using stratified cluster random sampling method. Physical examinations and questionnaire surveys were conducted. The Preece & Baines growth Model 1 was used to calculate the age at take off of height velocity (ATO) and age at peak height velocity (APHV), categorizing students into three groups: early pubertal timing group (< P 15 ), ontime group ( P 15 - P 85 ), and delayed group (> P 85 ). Binary Logistic regression was used to analyze its association with depressive symptoms.
Results:
The ATO for male and female high school students in Suzhou was (9.35±1.23) and ( 8.12 ±1.52) years old, respectively. The mean APHV was (12.35±0.74) years old for boys and (10.91±0.82) years old for girls. The overall prevalence of depressive symptoms was 34.22%, with no statistically significant gender difference ( χ 2=0.42, P =0.52). Significant differences in depressive symptom prevalence were observed across grade levels, breakfast frequency, weekly days of moderate to vigorous physical activity, daily sleep duration, history of school bullying, and the presence of Internet addiction ( χ 2=5.03-69.21, all P < 0.05 ). After adjusting for age, body mass index, region, boarding status, breakfast frequency, weekly moderate to vigorous physical activity days, sleep duration, campus bullying, and presence of Internet addiction, Logistic regression analysis revealed that when ATO was used to evaluate pubertal timing, the risk of depressive symptoms in the delayed group of boys was 1.65 times that of the on time group (95% CI =1.24-2.19); when APHV was used to evaluate pubertal timing, the risks of depressive symptoms in the early pubertal timing group and delayed group of boys were 1.43 times (95% CI =1.07-1.91) and 1.41 times (95% CI =1.05-1.88) of that of the on time group, respectively (all P <0.05). No statistically significant associations were found among females (all P > 0.05 ).
Conclusion
The prevalence of depressive symptoms among high school students in Suzhou is relatively high, and both early and delayed puberty timing in boys are associated with depressive symptoms.
6.Prevalence and related factors of screening myopia among students in special education schools in Tianjin
XI Wei, HAN Hui, XIONG Wenjuan, HAN Yu, WANG Hui, ZHANG Xin
Chinese Journal of School Health 2025;46(3):443-446
Objective:
To understand the current situation and related factors of screening myopia among students in special education schools, so as to provide evidence for promoting the health level of this population.
Methods:
From November 2021 to December 2023, a total of 281 students from 6 special education schools in 5 districts of Tianjin were selected by cluster random sampling method for computer optometry visual acuity examination for non ciliary paralysis and questionnaire survey. Multiple Logistic regression was performed to analyze the influencing factors of screening myopia among special education students.
Results:
The screening myopia detection rate among these special education students in Tianjin was 27.0%, and the screening myopia detection rates of students with autism, developmental delays, and intellectual disabilities were 22.4%, 12.5%, and 33.0%, respectively. The degree of myopia increased with age ( χ 2 trend =22.65, P <0.01). Multivariate Logistic regression analysis showed that age(10-13 years old: OR =5.40, 14-17 years old: OR =8.40, 18-23 years old: OR =6.02), accommodation(non resident: OR =0.29), daily mobile phone usage ≥2 hours ( OR =2.37), and daily computer/tablet usage ≥2 hours ( OR =2.70) were the risk factors for screening myopia among special education students ( P <0.05).
Conclusions
The detection rate and degree of screening myopia increase with age in special education students. Prolonged screen time exposure is a primary risk factor for screening myopia in special education students. Effective myopia prevention and control strategies should be designed according to the characteristics of special education students.
7.Epidemiological distribution characteristics and transmission patterns of Campylobacter in a Shandong broiler slaughterhouse
Shuai MIAO ; Xiu-mei HUANG ; Lin WANG ; Jun-hui LIU ; Jian-mei ZHAO ; Yu-bin GAO ; Shi-ping SONG ; Si-yu ZHANG ; Na LIU ; Ge ZHAO ; Xi-yue ZHANG ; Jun-wei WANG ; Juan WANG ; Zhi-na QU
Chinese Journal of Zoonoses 2025;41(6):583-591
This research investigated the contamination level,distribution of drug-resistant strains,and molecular epidemiologi-cal characteristics of Campylobacter,and further explored transmission pathways and prevention strategies.Cecum,chicken carcass,chicken product,and environmental samples,as well as swabs from workers'hands,were collected from a slaughterhouse in a large broiler group in the Jiaodong area between August 2023 and July 2024.Quantitative contamination assessment of Campylobacter in chicken carcasses and chicken products was performed.After microbial mass spectrometry identification,the representative strains of different links were selected for drug resistance testing and whole genome sequencing(WGS).On the basis of the sequencing results,the resistance genes,virulence genes,multilocus sequence typing(MLST),and phylogenetic characteristics of representative strains were analyzed.Homology comparisons were performed between isolates and strains from patients with diarrhea in the NCBI database.A total of 297 Campylobacter strains were isolated from 806 samples,and the overall detection rate was 36.85%.The detection rate of Campylobacter was highest in the evisceration process(47.33%),followed by the cutting process(35.64%).Overall,the Campylo-bacter detection rate first increased,then decreased,and subsequently increased.Drug sensitivity testing revealed that 90 isolates were resistant to nalidixic acid and ciprofloxacin,and 94.97%of isolates were resistant to tetracycline.WGS showed that both Campylo-bacter jejuni(C.jejuni)and Campylobacter coli(C.coli)carried many drug resistance and virulence genes.ST-14176 of C.jejuni was isolated for the first time herein.The predominant ST-8261 strain of C.jejuni and ST-860,ST-829,and ST-1586 strains of C.coli are known to cause human diarrhea.LOS expression genes associated with Guillain-Barré syndrome(GBS)were detected in both C.jejuni isolates from the slaughter chain and patients with GBS.Some strains exhibited close genetic relatedness to human-derived Campylo-bacter strains from the NCBI database.The detection rate of Campylobacter in the slaughterhouse first increased,then decreased,and subsequently increased,and the quantitative contamination level of each link was similar to the detection rate.Quantitative analysis of chicken carcasses/products revealed that the average bacterial load was highest in eviscerated carcasses(102.80 cfu/g),and the high-est amount of Campylobacter in chicken products reached 451.80 cfu/g.Abundant drug resistance genes and virulence genes were iden-tified,and the drug resistance genes were highly correlated with the drug resistance rate.Therefore,surveillance intensity and control measures for Campylobacter in slaughter processes should be strengthened.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
10.Monte Carlo simulation study of the effect of filter on radiotherapy dosimetry in superficial X-ray therapy apparatus
Li TAO ; Hui ZHANG ; Yikai WU ; Junyi LIU ; Miao QI ; Ning GAO ; Yankui CHANG ; Xi PEI ; Zhi CHEN ; Xie XU
Chinese Journal of Radiological Medicine and Protection 2025;45(3):194-201
Objective:To explore the dosimetry optimization strategy based on filter thickness and shape selection for the bulb superficial X-ray radiotherapy unit.Methods:Monte Carlo code TOPAS was used to model tubular equipment, and the dose distribution from six X-ray energies (50-150 kV) and five conventional aluminum filters (0.5-3.0 mm) with different thickness were simulated in the water model. The percentage depth dose (PDD) curve along the central axis, the center-axis profile dose at different depths, and the lateral dose distribution were analyzed. The dose distribution of three different designs of aluminum filters (conventional cylindrical, conical and oblique cylindrical filters) was compared to evaluate the effect of dosimetric optimization of different filter shapes.Results:Under the same energy, increasing the thickness of the filter can optimize the superficial skin dose, and the optimization effect of depth dose uniformity can be increased by 26% at a depth of 5.5 mm at 70 kV energy. The raised, flat and inclined dose distribution modes can be achieved by using conventional cylindrical, conical and inclined aluminum filters.Conclusions:By selecting the appropriate X-ray energy and filter thickness, an ideal dose distribution matching the tumor depth can be achieved. The application of personalized filters is also of great significance for diverse target areas.


Result Analysis
Print
Save
E-mail