1.Reporting Status of Clinical Practice Guideline Protocols: A Systematic Analysis
Huayu ZHANG ; Xufei LUO ; Hui LIU ; Qi ZHOU ; Yishan QIN ; Ye WANG ; Yuanyuan YAO ; Haodong LI ; Xiaohui WANG ; Yaolong CHEN
Medical Journal of Peking Union Medical College Hospital 2026;17(1):255-262
To systematically analyzed the reporting status of core elements in publicly available clinical practice guideline(hereafter referred to as "guideline") protocols published domestically and internationally over the past decade, identified existing problems, and provided evidence to inform the standardized writing and publication of future guideline protocols. A systematic search was conducted in Chinese and English databases for clinical practice guideline protocols published during the past ten years. The basic characteristics and reporting of core elements—including registration information, conflict of interest management, evidence grading, development process and timeline planning, as well as dissemination and implementation—were extracted and analyzed. Chi-square tests were performed to explore associations between protocol characteristics and the reporting of core elements. A total of 94 guideline protocols were included, of which 67 were in Chinese(71.28%) and 27 were in English(28.72%). Overall, 82.98% of the guideline protocols were registered, 92.55% reported management of conflicts of interest, 97.87% reported evidence searching, 88.30% reported evidence grading, and 89.36% described dissemination and implementation strategies. However, only 55.32% reported the guideline development process, and merely 23.40% reported timeline planning. Further analysis indicated that the reporting of registration, evidence searching, development process, and timeline planning was associated with year of publication. Differences were observed between domestic and international guidelines in reporting registration, conflict of interest management, development process, time planning, and dissemination and implementation. Guidelines intended for development exhibited higher reporting rates for registration, development process, and dissemination and implementation compared to those planned for updating or adaptation. Although current guideline protocols demonstrate relatively adequate reporting of methodological elements, deficiencies remain in development process and timeline planning. Future efforts should focus on promoting the publication and standardized reporting of guideline protocols, enhancing the international recognition of registration platforms, and strengthening the development process and timeline planning to advance the scientific rigor and transparency of guideline development.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Mechanism of vanillic acid against cardiac fibrosis induced by isoproterenol in mice based on Drp1/HK1/NLRP3 and mitochondrial apoptosis signaling pathways.
Hai-Bo HE ; Mian WU ; Jie XU ; Qian-Qian XU ; Fang-Zhu WAN ; Hua-Qiao ZHONG ; Ji-Hong ZHANG ; Gang ZHOU ; Hui-Lin QIN ; Hao-Ran LI ; Hai-Ming TANG
China Journal of Chinese Materia Medica 2025;50(8):2193-2208
This study investigated the effects and underlying mechanisms of vanillic acid(VA) against cardiac fibrosis(CF) induced by isoproterenol(ISO) in mice. Male C57BL/6J mice were randomly divided into control group, VA group(100 mg·kg~(-1), ig), ISO group(10 mg·kg~(-1), sc), ISO + VA group(10 mg·kg~(-1), sc + 100 mg·kg~(-1), ig), ISO + dynamin-related protein 1(Drp1) inhibitor(Mdivi-1) group(10 mg·kg~(-1), sc + 50 mg·kg~(-1), ip), and ISO + VA + Mdivi-1 group(10 mg·kg~(-1), sc + 100 mg·kg~(-1), ig + 50 mg·kg~(-1), ip). The treatment groups received the corresponding medications once daily for 14 consecutive days. On the day after the last administration, cardiac functions were evaluated, and serum and cardiac tissue samples were collected. These samples were analyzed for serum aspartate aminotransferase(AST), lactate dehydrogenase(LDH), creatine kinase-MB(CK-MB), cardiac troponin I(cTnI), reactive oxygen species(ROS), interleukin(IL)-1β, IL-4, IL-6, IL-10, IL-18, and tumor necrosis factor-α(TNF-α) levels, as well as cardiac tissue catalase(CAT), glutathione(GSH), malondialdehyde(MDA), myeloperoxidase(MPO), superoxide dismutase(SOD), total antioxidant capacity(T-AOC) activities, and cytochrome C levels in mitochondria and cytoplasm. Hematoxylin-eosin, Masson, uranium acetate and lead citrate staining were used to observe morphological and mitochondrial ultrastructural changes in the cardiac tissues, and myocardial injury area and collagen volume fraction were calculated. Flow cytometry was applied to detect the relative content and M1/M2 polarization of cardiac macrophages. The mRNA expression levels of macrophage polarization markers [CD86, CD206, arginase 1(Arg-1), inducible nitric oxide synthase(iNOS)], CF markers [type Ⅰ collagen(Coll Ⅰ), Coll Ⅲ, α-smooth muscle actin(α-SMA)], and cytokines(IL-1β, IL-4, IL-6, IL-10, IL-18, TNF-α) in cardiac tissues were determined by quantitative real-time PCR. Western blot was used to detect the protein expression levels of Coll Ⅰ, Coll Ⅲ, α-SMA, Drp1, p-Drp1, voltage-dependent anion channel(VDAC), hexokinase 1(HK1), NOD-like receptor protein 3(NLRP3), apoptosis-associated speck-like protein(ASC), caspase-1, cleaved-caspase-1, gasdermin D(GSDMD), cleaved N-terminal gasdermin D(GSDMD-N), IL-1β, IL-18, B-cell lymphoma-2(Bcl-2), B-cell lymphoma-xl(Bcl-xl), Bcl-2-associated death promoter(Bad), Bcl-2-associated X protein(Bax), apoptotic protease activating factor-1(Apaf-1), pro-caspase-3, cleaved-caspase-3, pro-caspase-9, cleaved-caspase-9, poly(ADP-ribose) polymerase-1(PARP-1), and cleaved-PARP-1 in cardiac tissues. The results showed that VA significantly improved cardiac function in mice with CF, reduced myocardial injury area and cardiac index, and decreased serum levels of AST, CK-MB, cTnI, LDH, ROS, IL-1β, IL-6, IL-18, and TNF-α. VA also lowered MDA and MPO levels, mRNA expressions of IL-1β, IL-6, IL-18, and TNF-α, and mRNA and protein expressions of Coll Ⅰ, Coll Ⅲ, and α-SMA in cardiac tissues, and increased serum levels of IL-4 and IL-10, cardiac tissue levels of CAT, GSH, SOD, and T-AOC, and mRNA expressions of IL-4 and IL-10. Additionally, VA ameliorated cardiac pathological damage, inhibited myocardial cell apoptosis, inflammatory infiltration, and collagen fiber deposition, reduced collagen volume fraction, and alleviated mitochondrial damage. VA decreased the ratio of F4/80~+CD86~+ M1 cells and the mRNA expressions of CD86 and iNOS in cardiac tissue, and increased the ratio of F4/80~+CD206~+ M2 cells and the mRNA expressions of CD206 and Arg-1. VA also reduced protein expressions of p-Drp1, VDAC, NLRP3, ASC, caspase-1, cleaved-caspase-1, GSDMD, GSDMD-N, IL-1β, IL-18, Bad, Bax, Apaf-1, cleaved-caspase-3, cleaved-caspase-9, cleaved-PARP-1, and cytoplasmic cytochrome C, and increased the expressions of HK1, Bcl-2, Bcl-xl, pro-caspase-3, pro-caspase-9 proteins, as well as the Bcl-2/Bax and Bcl-xl/Bad ratios and mitochondrial cytochrome C content. These results indicate that VA has a significant ameliorative effect on ISO-induced CF in mice, alleviates ISO-induced oxidative damage and inflammatory response, and its mechanism may be closely related to the inhibition of Drp1/HK1/NLRP3 and mitochondrial apoptosis signaling pathways, suppression of myocardial cell inflammatory infiltration and collagen fiber deposition, reduction of collagen volume fraction and CollⅠ, Coll Ⅲ, and α-SMA expressions, thus mitigating CF.
Animals
;
Isoproterenol/adverse effects*
;
Male
;
Mice
;
Signal Transduction/drug effects*
;
Vanillic Acid/administration & dosage*
;
Dynamins/genetics*
;
Mice, Inbred C57BL
;
Fibrosis/genetics*
;
Apoptosis/drug effects*
;
Mitochondria/metabolism*
;
NLR Family, Pyrin Domain-Containing 3 Protein/genetics*
;
Myocardium/metabolism*
;
Humans
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.0.05% Cyclosporine A combined with Olopatadine eye drops for the treatment of allergic conjunctivitis-related dry eye disease
Jinfen LI ; Yue LI ; Hui HUANG ; Qianqian LAN ; Zhou ZHOU ; Wenjing HE ; Yuanjun QIN ; Li JIANG ; Fan XU
International Eye Science 2025;25(7):1152-1159
AIM: To explore the efficacy of 0.05% cyclosporine A combined with olopatadine eye drops in treating allergic conjunctivitis-related dry eye disease.METHODS: A total of 63 patients(63 eyes)with allergic conjunctivitis-related dry eye disease in the People's Hospital of Guangxi Zhuang Autonomous Region from August 2022 to April 2023 were enrolled and randomly divided into control group(n=33)and observation group(n=30). The patients of the control group were administrated with 0.1% olopatadine eye drops and 0.3% sodium hyaluronate eye drops, while the observation group was administrated with 0.1% olopatadine eye drops and 0.05% cyclosporine A eye drops. The ocular surface disease index(OSDI), total ocular symptom score(TOSS), conjunctival congestion score, conjunctival papillae and follicle score, Schirmer I test(SⅠt), tear meniscus height(TMH), meibomian gland secretion ability and property score, meibomian gland loss area score, corneal fluorescein staining(CFS), tear film break-up time(BUT), noninvasive first tear film break-up time(NIBUTf), noninvasive average tear film break-up time(NIBUTav)before and after treatment and the drug safety during the treatment period of both groups of patients were evaluated.RESULTS: After treatment, OSDI, TOSS, conjunctival congestion score, conjunctival papillae and follicle score, SⅠt, TMH, meibomian gland secretion ability score and property score, CFS, BUT, NIBUTf, and NIBUTav of the observation group showed improvements compared with those before treatment(all P<0.017). Among these, OSDI, TOSS, conjunctival congestion score, conjunctival papillae and follicle score, BUT, NIBUTf, and NIBUTav demonstrated significant improvement compared with the control group(all P<0.05). There was no statistically significant difference in meibomian gland loss area score between the two groups before and after treatment(P>0.05). During the treatment period, there were no local or systemic adverse reactions.CONCLUSION: The combined use of 0.05% cyclosporine A and olopatadine eye drops can significantly improve ocular discomfort symptoms of patients with dry eye disease associated with allergic conjunctivitis, such as red eyes, itchy eyes and foreign body sensation, promote tear film stability and have high safety.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Identification of Mycobacterium abscessus subsp.abscessus and subsp.massiliense based on MALDI-TOF MS and analysis for their characteristics
Xueya QIN ; Yong LIN ; Cong ZHOU ; Hui ZHANG ; Maosuo XU
Chinese Journal of Clinical Laboratory Science 2025;43(2):81-87
Objective To perform the identification at the subspecies-level of Mycobacterium abscessus(M.abscessus)and analyze its characteristics based on matrix-assisted laser desorption ionization time-of-flight mass spectrometry(MALDI-TOF MS).Methods Bi-otyper software was used to construct the predicted peak spectrum of M.abscessus subsp.abscessus and M.abscessus subsp.massiliense.The predicted peak spectrum was constructed with expected maximum peak value number of 70 and peak frequency of 100%in the ex-perimental group and control group,respectively.A blind test was performed on 31 strains of M.abscessus that were not used to con-struct predictive peak spectra to evaluate the identification efficiency of predictive peak spectra.FlexAnalysis software was used to sum-marize and analyze the list of mass spectral peak value of M.abscessus,and screen the specific peaks in mass spectra of different sub-species of M.abscessus.The principal component analysis(PCA)algorithm was used to perform the cluster analysis for the data from mass spectrometry of M.abscessus,and explore the feasibility of PCA clustering in distinguishing the subspecies of M.abscessus.Results In the experimental group,96.8%(30/31)of the strains were correctly identified,and one strain of M.abscessus subsp.massiliense with rough colony form was mistakenly identified as M.abscessus subsp.abscessus.In control group,77.4%(24/31)of the strains were correctly identified,but 7 strains of M.abscessus subsp.massiliense were incorrectly identified or unable to be identified.The identification efficiency in the experimental group was significantly better than that in the control group with statistical difference(X2=5.167,P=0.026).M.abscessus subsp.abscessus exhibited three specific peaks(m/z 4 001.67,4 386.81 and 4 963.17),and M.abscessus subsp.massiliense also exhibited three specific peaks(m/z 4 950.48,4 381.78 and 5 214.90).In the PCA 3D scatter plot,the data points of M.abscessus subsp.abscessus and M.abscessus subsp.massiliense were relatively dispersed without obvious clus-tering.The PC A dendrograph could be divided into six branches in which only four branches were composed of a single subspecies.The minimum level value of distance between M.abscessus subsp.abscessus and M.abscessus subsp.massiliense was about 0.1.Conclusion The predicted peak spectrum based on MALDI-TOF MS with the expected maximum peak number of 70 could accurately identify M.abscessus at the subspecies level.The specific peak of mass spectrometry method in this study should be feasible to distinguish the subspecies of M.abscessus subsp.abscessus and the subspecies of M.abscessus subsp.Massiliense,but PCA cluster analysis cannot be used as a means to distinguish M.abscessus subsp.abscessus from M.abscessus subsp.massiliense.
10.Screening and preliminary evaluation of nanobodies targeting granulocyte-macrophage colony-stimulating factor
Jiao LIU ; Lei CHEN ; Hui QIN ; Qinlin KANG ; Gege LI ; Zhixin YANG ; Peng DU ; Chunyang ZHOU
Chinese Journal of Pharmacology and Toxicology 2025;39(8):591-599
OBJECTIVE To screen and obtain nanobodies with neutralizing activity against granulo-cyte-macrophage colony stimulating factor(GM-CSF)to contribute to investigations into the mecha-nism of inflammation interventions and the development new drugs.METHODS Recombinant human GM-CSF was subcutaneously injected to immunize camels.Peripheral blood was collected after five immunizations,and mononuclear cells were isolated.Total mRNA was extracted,and the variable domains of the heavy chain of heavy-chain antibody(VHH,also called nanobody)genes were obtained by PCR amplification after reverse transcription.The genes were cloned into the pADSCFV-S phage display vector and electrotransformed into TG1 competent cells to construct a nanobody immune library that was screened with recombinant human GM-CSF immobilized on a solid phase.The VHH genes specifi-cally binding to human GM-CSF were cloned into the pABG eukaryotic expression vector before VHH-Fc samples were prepared by using the human embryonic kidney 293 fibroblast expression system.The binding activity of candidate VHH-Fc molecules to GM-CSF was investigated through ELISA response curves,and binding colorimetric values with different antigens were detected to determine their specificity.The binding affinity between VHH-Fc candidates and GM-CSF was measured using biolayer interferom-etry(BLI).The inhibition rate curve of VHH-Fc candidates on GM-CSF was detected through cell prolif-eration assays to determine its neutralization activity.The Uncle system was used to investigate its thermal stability.100 μg of VHH-Fc was injected into mice via the tail vein,and the serum concentration of VHH-Fc was quantitatively detected by ELISA to examine its pharmacokinetic curve in mice.RESULTS The camel serum titer of anti-human GM-CSF antibodies was higher than 1:800 000 after the fifth immuni-zation,and the capacity of the constructed nanobody library was about 5.55×107.Following the screening process,five candidate VHH-Fc molecules specifically binding to human GM-CSF were obtained.Among these,22N10 effectively neutralized the cell proliferation-promoting activity of GM-CSF(the IC50 value was 17.23 nmol·L-1).Subsequent studies revealed that 22N10 interacted with human GM-CSF with an affinity of 1.97×10-8 mol·L-1,blocked the binding of GM-CSF to its receptor CSF2Rα,exhibited good thermal stability(Tm1=59.2℃),and showed favorable metabolic characteristics in mice.CONCLU-SION A new candidate nanobody molecule 22N10 targeting human GM-CSF is obtained which is expected to facilitate the drug development and mechanism investigations.

Result Analysis
Print
Save
E-mail