1.Current status of quality control of kV X-ray radiotherapy equipment
Zechen FENG ; Zihan WANG ; Yongzhong MA ; Hui XU ; Qiao MA ; Hailiang LI
Chinese Journal of Radiological Health 2024;33(4):466-471
kV X-ray radiotherapy was the primary mode of radiotherapy widely used to treat many types of cancer, including deep tumors, before the invention of the Co-60 therapy machine and the electron linear accelerator, which gradually replaced kV X-ray radiotherapy. kV X-ray radiotherapy equipment requires less space and shielding, and still has application value in the treatment of skin lesions and superficial tumors. Especially in recent years, kV X-ray has been used in the treatment of keloid, and electronic brachytherapy equipment has been used in intracavitary, intraoperative, and superficial radiotherapy. Therefore, kV X-ray radiotherapy has seen renewed application. The quality control of kV X-ray radiotherapy equipment is the key to ensure the treatment effect and safety of patients. This paper reviews the current status of quality control of kV X-ray radiotherapy equipment and provides a reference for the formulation of quality control assessment standards for kV X-ray radiotherapy equipment.
2.Effectiveness of recombinant Mycobacterium tuberculosis fusion protein skin test in screening for latent tuberculosis infection among HIV/AIDS patients
WANG Hui ; LI Jincheng ; LU Xing ; WANG Jinfu ; ZHU Limei ; LIU Qiao
Journal of Preventive Medicine 2024;36(7):639-643
Objective:
To evaluate the effectiveness of recombinant Mycobacterium tuberculosis fusion protein skin test (EC-ST) in screening for latent tuberculosis infection (LTBI) among HIV/AIDS patients, so as to provide insights into the applicability of EC-ST in LTBI screening among HIV/AIDS patients.
Methods:
From April to June 2023, HIV/AIDS patients under management and treatment in Yangzhou City, Jiangsu Province, were selected as study subjects. Basic information was collected through questionnaire surveys. LTBI was screened by EC-ST and interferon-gamma release assay (IGRA). Taking IGRA results as the diagnostic standard, the positive rate, sensitivity, specificity and consistency rate of EC-ST, and the impact of CD4+T lymphocyte (CD4) counts on the screening effect of EC-ST were analyzed.
Results:
A total of 523 HIV/AIDS patients were screened, including 458 males (87.57%) and 65 females (12.43%). The median age was 48.00 (interquartile range, 21.00) years. The positive rate of EC-ST was 7.27% and the positive rate of IGRA was 7.46%, with no statistically significant difference (P>0.05). The consistency rate of the two methods was 94.84%, and the Kappa value of 0.621 (95%CI: 0.489-0.752, P<0.05). The sensitivity of EC-ST was 64.10% and the specificity was 97.31%. Comparing the groups with CD4 counts <500 and ≥500 cells/μL, the consistency rates of the two methods were 95.32% and 94.44%, and the Kappa values were 0.568 and 0.650, respectively (both P<0.05). There were no statistically significant differences in the positive rates, sensitivity, and specificity of EC-ST (all P>0.05). Comparing the groups with CD4 counts <200 and ≥200 cells/μL, the consistency rates of the two methods were 96.55% and 94.62%, and the Kappa values were 0.648 and 0.619, respectively (both P<0.05). There were no statistically significant differences in the positive rates, sensitivity, and specificity of EC-ST (all P>0.05).
Conclusion
The effectiveness of EC-ST in screening for LTBI among HIV/AIDS patients is consistent with that of IGRA and is not affected by CD4 counts.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Urine metabolomics study of Psoralea corylifolia in improving learning and memory ability in APP/PS1 mice
Yue QIAO ; Ao XUE ; Yue ZHANG ; Hong-dan XU ; Guang LI ; Ji-hui ZHAO ; Jing HU ; Ning ZHANG
Acta Pharmaceutica Sinica 2024;59(4):1010-1016
Urine nontargeted metabolomics technology was developed for investigating the effect and mechanism of improving learning and memory ability in APP/PS1 mice of
8.Cloning and interacted protein identification of AP1 homologous gene from Lonicera macranthoides
Ya-xin YU ; Li-jun LONG ; Chang-zhu LI ; Hui-jie ZENG ; Zhong-quan QIAO ; Si-si LIU ; Ying-zi MA
Acta Pharmaceutica Sinica 2024;59(10):2880-2888
The
9.Cloning and interacted protein identification of AGL12 gene from Lonicera macranthoides
Li-jun LONG ; Hui-jie ZENG ; Zhong-quan QIAO ; Xiao-ming WANG ; Chang-zhu LI ; Si-si LIU ; Ying-zi MA
Acta Pharmaceutica Sinica 2024;59(5):1458-1466
MADS-box protein family are important transcriptional regulatory factors in plant growth and development. The
10.microRNA-26a inhibits extracellular matrix synthesis in high glucose-induced renal tubular epithelial cells by regulating ferroptosis
Xingyue LI ; Yunyang QIAO ; Hui ZHENG ; Jialing JI ; Aiqing ZHANG
Acta Universitatis Medicinalis Anhui 2024;59(2):254-259
Objective To investigate the effect and possible mechanism of microRNA-26a(miR-26a)on the syn-thesis of extracellular matrix(ECM)induced by high glucose(HG)in renal tubular epithelial cells(RTECs).Methods A model of diabetic kidney disease(DKD)was constructed by inducing RTECs with HG.MiR-26a was overexpressed in HG-induced RTECs,and RT-qPCR and Western blot were used to assess the effects of miR-26a on ECM synthesis and ferroptosis-related markers in HG-treated RTECs.Ferrostatin(Fer-1)was used to inhibit ferroptosis in the DKD model,and its impact on ECM synthesis was evaluated.RT-qPCR and Western blot were performed to measure ferroptosis-related markers,and fluorescence microscopy was used to observe the intensity of reactive oxygen species(ROS).Results Compared with the control group,the expression of miR-26a decreased in HG-treated cells,while the expression levels of ECM synthesis-related indexes fibronectin and collagen Ⅰ in-creased.After overexpressing miR-26a,the HG+miR-26a group showed a significant increase in miR-26a expres-sion and a decrease in fibronectin and collagen Ⅰ expression compared to the HG group.In terms of ferroptosis,the protein and mRNA expression of SLC7A11 and GPX4 significantly decreased,the expression of TFR-1 and AC-SL4 significantly increased,and the fluorescence intensity of ROS was significantly enhanced in the HG group com-pared with the control group.Inhibition of ferroptosis in the HG+Fer-1 group resulted in significant changes in fer-roptosis and ECM synthesis-related indicators expression levels compared to the HG group.Furthermore,re-expres-sion of miR-26a in the HG+miR-26a led to significant changes in ferroptosis-related indicators expression levels and decreased ROS fluorescence intensity compared to the HG group.Conclusions In HG-induced RTECs,miR-26a inhibits the occurrence of ferroptosis,thus reducing ECM synthesis.


Result Analysis
Print
Save
E-mail