1.Bioequivalence study of buspirone hydrochloride tablets in Chinese healthy subjects
Ping LU ; Rui WANG ; Hui-Hui WU ; Hai-Yan LIU ; Ge-Fei HE ; Shun-Zhi ZHANG ; Wei WU
The Chinese Journal of Clinical Pharmacology 2024;40(5):723-727
Objective To study the pharmacokinetic characteristics of buspirone hydrochloride tablets in healthy adult populations under conditions of fasting and postprandial administration.Methods A single-center,randomized,three-cycle partially repeated crossover trial design was adopted,and 36 subjects were enrolled on fasting/postprandial,one tablet of the test preparation was taken in one cycle,one tablet of reference preparation(5 mg of buspirone tablets)was taken once in each of 2 cycles,the drug concentration of buspirone in plasma was determined by liquid chromatography-tandem mass spectrometry,and the pharmacokinetic parameters were calculated by WinNonlin software.Results Main pharmacokinetics of buspirone after oral administration of test and reference preparations in fasting group,the Cmax was(285.72±286.08)and(308.94±341.03)pg·mL-1;AUC0-t were(577.09±491.10)and(618.62±642.56)pg·mL-1·h;AUC0-∞ were(586.85±510.04)and(655.92±687.95)pg·mL-1·h;tmax was 0.75(0.33-4.00)and 0.75(0.33-1.75)h.Main pharmacokinetics of buspirone after oral administration of test and reference preparations in the postprandial group,the Cmax were(676.36±603.64)and(760.33±610.27)pg·mL-1;AUC0-t were(1 755.58±1 001.69)and(1 743.00±1 073.33)pg·h·mL-1;AUC0-∞ were(1 839.97±1 044.60)and(1 818.00±1 106.95)pg·mL-1·h;tmax was 1.25(0.25-4.50)and 1.00(0.25-3.50)h.The 90%confidence intervals of the AUC0-t and AUC0-∞ geometric mean ratios of the test preparation and the reference preparation in the fasting test and the postprandial test all fell between 80.00%and 125.00%,and the 95%upper confidence limit of of Cmax was ≤0 and geometric mean ratios point estimates fall between 80.00%and 125.00%.Conclusion Two kinds of buspirone hydrochloride are bioequivalent in Chinese healthy adult subject.
2.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
3.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
4.Clinicopathologic features of stomach oxyntic gland neo-plasms on 49 patients
Lu-Lu ZHANG ; Hui LI ; Bing-Xin GUAN ; Yu-Ping ZHENG ; Xiao-Lin WU ; Cheng-Jun ZHOU
Chinese Journal of Current Advances in General Surgery 2024;27(1):30-35
Objective:To analyze the clinicopathological features of gastric oxyntic gland neo-plasms.Methods:Forty-nine cases of stomach oxyntic gland neoplasms including oxyntic gland adenoma(OGA)and gastric adenocarcinoma of the fundic gland type(GA-FG)diagnosed in the Sec-ond Hospital of Shandong University from January 2016 to December 2020 were selected.The clini cal information,endoscopic appearance,histological features and immunophenotype were analyzed retrospectively,and followed up.Results:Age of the gastric oxyntic gland neoplasm patients ranged from 19 to 83 years old,with an average age of(57.3±2.4)years old.The male-to-female ratio was 24:25.Most of the lesions were located in the gastric body(27/49)and fundus(15/49).There were four endoscopic phenotypes:flat bulging,polypoid,flat and depression.In some lesions,there were dilated dendritic vessels.48 cases were single onset.The mean maximum diameter of lesions was(3.9±0.5)mm(1.0~7.0 mm).Seven cases showed submucosal invasion,and the inva-sion depth was less than 500 μm.The tumor consists of the dense glandular and the glandular con-nects to form a strip shape,which is irregularly branched and labyrinthlike under the microscope.These tumor cells were well differentiated and the morphology was similar to oxyntic gland cells.The chief cells were the predominant cells.The nucleus was mildly enlarged with slight pleomorphism and the mitosis was uncommon.The oxyntic gland neoplasms of the stomach were diffusely posi-tive for Mucin-6(MUC6)(100%)and Pepsinogen Ⅰ(83%),focally positive for H+/K+-ATPase(58%).Conclusions:The stomach oxyntic gland neoplasm is a new histology type with unique clinico-pathological features.The incidence of this neoplasm is low and the prognosis is good but it still needs long-term follow-up.
5.Research progress on the antitumor efficacy improvement for nanomedicine by combinatorial modification with multiligand
Xiao-yu ZHANG ; Song-gu WU ; Hui XU ; Jun-bo GONG ; Jin-feng XING ; Zhen-ping WEI
Acta Pharmaceutica Sinica 2024;59(7):1942-1951
After entering the body from the drug delivery site, antitumor nanomedicines need to cross a series of physiopathological barriers to reach the target site of action to effectively exert antitumor therapeutic effects. The ligand modification strategy is a classic method to enhance the efficiency of nanomedicine delivery
6.TSHR Variant Screening and Phenotype Analysis in 367 Chinese Patients With Congenital Hypothyroidism
Hai-Yang ZHANG ; Feng-Yao WU ; Xue-Song LI ; Ping-Hui TU ; Cao-Xu ZHANG ; Rui-Meng YANG ; Ren-Jie CUI ; Chen-Yang WU ; Ya FANG ; Liu YANG ; Huai-Dong SONG ; Shuang-Xia ZHAO
Annals of Laboratory Medicine 2024;44(4):343-353
Background:
Genetic defects in the human thyroid-stimulating hormone (TSH) receptor (TSHR) gene can cause congenital hypothyroidism (CH). However, the biological functions and comprehensive genotype–phenotype relationships for most TSHR variants associated with CH remain unexplored. We aimed to identify TSHR variants in Chinese patients with CH, analyze the functions of the variants, and explore the relationships between TSHR genotypes and clinical phenotypes.
Methods:
In total, 367 patients with CH were recruited for TSHR variant screening using whole-exome sequencing. The effects of the variants were evaluated by in-silico programs such as SIFT and polyphen2. Furthermore, these variants were transfected into 293T cells to detect their Gs/cyclic AMP and Gq/11 signaling activity.
Results:
Among the 367 patients with CH, 17 TSHR variants, including three novel variants, were identified in 45 patients, and 18 patients carried biallelic TSHR variants. In vitro experiments showed that 10 variants were associated with Gs/cyclic AMP and Gq/11 signaling pathway impairment to varying degrees. Patients with TSHR biallelic variants had lower serum TSH levels and higher free triiodothyronine and thyroxine levels at diagnosis than those with DUOX2 biallelic variants.
Conclusions
We found a high frequency of TSHR variants in Chinese patients with CH (12.3%), and 4.9% of cases were caused by TSHR biallelic variants. Ten variants were identified as loss-of-function variants. The data suggest that the clinical phenotype of CH patients caused by TSHR biallelic variants is relatively mild. Our study expands the TSHR variant spectrum and provides further evidence for the elucidation of the genetic etiology of CH.
7.Implementation of surveillance,prevention and control of healthcare-asso-ciated infection in maternal and child healthcare institutions:A nation-wide investigation report
Shuo LI ; Xi YAO ; Hui-Xue JIA ; Wei-Guang LI ; Xun HUANG ; Shu-Mei SUN ; Xi CHENG ; Qing-Lan MENG ; Xiang ZHANG ; Jing-Ping ZHANG ; Ya-Wei XING ; Qing-Qing JIANG ; Lian-Xuan WU ; Bing-Li ZHANG ; Xiao-Jing LIU ; Liu-Yi LI
Chinese Journal of Infection Control 2024;23(3):323-329
Objective To investigate the implementation of surveillance,prevention and control measures for healthcare-associated infection(HAI)in maternal and child healthcare(MCH)institutions,and provide policy evi-dence for optimizing HAI prevention and control in MCH institutions.Methods Stratified sampling was conducted among the MCH institutions at provincial,municipal and county levels in 8 provinces/autonomous regions.A uni-fied questionnaire was designed and the online survey was conducted through"Questionnaire Star".Results The data from 123 MCH institutions were included in the analysis.90.24%of the MCH institutions carried out compre-hensive surveillance on HAI.The ratios of MCH institutions which implemented targeted surveillance on HAI in neonatal intensive care unit(NICU),surgical site infection,multidrug-resistant organisms(MDROs)and HAI in intensive care units(non-NICU excluded)were 89.66%,85.96%,80.77%,and 74.19%,respectively.51.22%MCH institutions adopted information surveillance system on HAI cases.94.31%MCH institutions carried out surveillance on hand hygiene compliance.Over 90%MCH institutions carried out surveillance on environment hy-giene in high-risk departments.71.54%MCH institutions conducted centralized cleaning,disinfection,sterilization and supply for reusable medical instruments in the central sterile supply department(CSSD).Over 90%MCH insti-tutions established three-level pre-examination triage systems.86.18%set up transitional wards.MCH institutions generally adopted a management model with established effective communication,full appointment visits,and sepa-rate visits for special medical groups,such as registered pregnant women,high-risk newborns,healthcare groups,and long-term rehabilitation patients.However,the ratio of institutions conducting on-line follow-up visits was less than 50%.Conclusion MCH institutions have generally carried out comprehensive and targeted surveillance on HAI.Information surveillance need to be facilitated.Hand hygiene and environmental hygiene surveillance has been popularized to a certain extent at all levels of MCH institutions.The cleaning,disinfection,sterilization,and supply processes of reusable medical devices in a few MCH institutions are not standardized.Special medical populations get effective management.On-line healthcare is to be further promoted.
8.Effect of circDCUN1D4 on proliferation,apoptosis and immune escape of lung cancer cells by regulating the miR-18a-5p/FBP1 axis
Chun-Hui SHI ; Jian-Ping LIN ; Chao WU
Journal of Regional Anatomy and Operative Surgery 2024;33(1):19-24
Objective To investigate the influences of circular RNA(circRNA)DCUN1D4 on the proliferation,apoptosis and immune escape of lung cancer cells by regulating the microRNA(miR)-18a-5p/fructose-1,6-bisphosphatase 1(FBP1)axis.Methods The human lung cancer cell lines H1975,H1650,A549 and SPCA-1 and human normal lung epidermal cells HPL-1 were selected,qRT-PCR was used to detect the expression levels of circDCUN1D4,miR-18a-5p and FBP1 mRNA in various cells.A549 cells in logarithmic growth phase were selected and divided into the blank group,circDCUN1D4 overexpression plasmid(circDCUN1D4)group,overexpression plasmid negative control(NC)group,circDCUN1D4+miR-18a-5p mimics negative control(circDCUN1D4+mimics NC)group,and circDCUN1D4+miR-18a-5p mimics group.The cell viability of each group was detected by CCK-8 method,the cell apoptosis was detected by flow cytometry,the expression levels of circDCUN1D4,miR-18a-5p and FBP1 mRNA of cells in each group were detected by qRT-PCR,the expression levels of FBP1,caspase-3,Ki67,proliferating cell nuclear antigen(PCNA)and programmed death ligand-1(PD-L1)were detected by Western blot,the targeting relationships of miR-18a-5p with circDCUN1D4 and FBP1 were verified by dual luciferase assay.Results Compared with HPL-1 cells,the mRNA expressions of circDCUN1D4 and FBP1 were significantly decreased(P<0.05),and the expression of miR-18a-5p was significantly increased(P<0.05).miR-18a-5p had targeting relationships with circDCUN1D4 and FBP1,respectively.Compared with the blank group and NC group,the OD values at 24 hours and 48 hours,and the expressions of Ki67,PCNA,miR-18a-5p and PD-L1 of cells in the circDCUN1D4 group were significantly decreased(P<0.05),and the apoptosis rate,and the expressions of circDCUN1D4,FBP1 and caspase-3 were significantly increased(P<0.05).Overexpression of miR-18a-5p reversed the inhibitory effect of circDCUN1D4 on the malignant behavior of lung cancer cells(P<0.05).Conclusion Overexpression of circDCUN1D4 can promote lung cancer cell apoptosis,inhibit lung cancer cell proliferation and immune escape,and its mechanism may be related to the regulation of miR-18a-5p/FBP1 axis.
9.Research status of chemical constituents,pharmacological effects and predictive analysis of quality markers of Hedyotis diffusa
Ying-Jie WANG ; Hui-Quan HU ; Qian WU ; Jia-Mei ZOU ; Yu-Hui PING
The Chinese Journal of Clinical Pharmacology 2024;40(15):2296-2300
Hedyotis diffusa has unique therapeutic effects on snake and insect bites,edema,cancer and other diseases,and is widely used clinically.However,the《Chinese Pharmacopoeia》has no record of the name of the plant,and there is no fundamental basis for its elaboration of the relationship between"composition-potency-quality marker(Q-Marker)".This article reviews the chemical constituents and pharmacological effects of Hedyotis diffusa,and combined with the concept of Q-Marker.Q-Marker predictions were made in terms of traditional efficacy,traditional medicinal properties and the measurability of chemical components,in order to provide a reference for the clinical applications,quality evaluation further studies of Hedyotis diffusa in the future.
10.Relationship between Phenotypic Changes of Dendritic Cell Subsets and the Onset of Plateau Phase during Intermittent Interferon Therapy in Patients with CHB
Liu YANG ; Yu Shi WANG ; Ting Ting JIANG ; Wen DENG ; Min CHANG ; Ling Shu WU ; Hua Wei CAO ; Yao LU ; Ge SHEN ; Yu Ru LIU ; Jiao Yuan GAO ; Jiao Meng XU ; Ping Lei HU ; Lu ZHANG ; Yao XIE ; Hui Ming LI
Biomedical and Environmental Sciences 2024;37(3):303-314
Objective This study aimed to evaluate whether the onset of the plateau phase of slow hepatitis B surface antigen decline in patients with chronic hepatitis B treated with intermittent interferon therapy is related to the frequency of dendritic cell subsets and expression of the costimulatory molecules CD40,CD80,CD83,and CD86. Method This was a cross-sectional study in which patients were divided into a natural history group(namely NH group),a long-term oral nucleoside analogs treatment group(namely NA group),and a plateau-arriving group(namely P group).The percentage of plasmacytoid dendritic cell and myeloid dendritic cell subsets in peripheral blood lymphocytes and monocytes and the mean fluorescence intensity of their surface costimulatory molecules were detected using a flow cytometer. Results In total,143 patients were enrolled(NH group,n = 49;NA group,n = 47;P group,n = 47).The results demonstrated that CD141/CD1c double negative myeloid dendritic cell(DNmDC)/lymphocytes and monocytes(%)in P group(0.041[0.024,0.069])was significantly lower than that in NH group(0.270[0.135,0.407])and NA group(0.273[0.150,0.443]),and CD86 mean fluorescence intensity of DNmDCs in P group(1832.0[1484.0,2793.0])was significantly lower than that in NH group(4316.0[2958.0,5169.0])and NA group(3299.0[2534.0,4371.0]),Adjusted P all<0.001. Conclusion Reduced DNmDCs and impaired maturation may be associated with the onset of the plateau phase during intermittent interferon therapy in patients with chronic hepatitis B.

Result Analysis
Print
Save
E-mail