1.Characteristic Analysis of Effective Components and Compounds of TCM for Prevention and Treatment of Breast Cancer Based on Wnt/β-catenin Signaling Pathway Targeting
Haoyang WANG ; Lin GUO ; Hui ZHAO ; Lihua CAO ; Na LI ; Mingsan MIAO
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(5):282-290
Breast cancer is a kind of malignant tumor with a complex mechanism, and its morbidity and mortality are increasing year by year, which seriously threatens women's health. At present, the main clinical treatments are surgical resection, radiotherapy, chemotherapy, and drug therapy, but they are often accompanied by side effects and adverse reactions, which affect the therapeutic effect. Traditional Chinese medicine (TCM) has the advantages of multi-component and multi-target treatment in the fight against breast cancer. The wnt/β-catenin signaling pathway is one of the classic pathways in cancer research. Abnormally activated Wnt/β-catenin signaling pathway inhibits β-catenin degradation by blocking the formation of Axin/glycogen synthase kinase 3β/adenomatous polyposis coli complex, thus promoting β-catenin nuclear metastasis, and it binds to T cell transcription factor/lymphoenhancer factor-1 to initiate downstream target genes and further interfere with the proliferation, migration, and invasion of tumor cells to affect the tumor process. Previous studies have shown that TCM monomers and compounds can mediate the Wnt/β-catenin signaling pathway to inhibit the malignant phenotype of breast cancer cells, thus playing an anti-breast cancer role, and the biochemical process involved in the regulation of therapeutic drugs has not been systematically combed. By analyzing and collating Chinese and foreign literature at the present stage, this paper discussed the association mechanism between Wnt/β-catenin signaling pathway and breast cancer and analyzed the internal mechanism of TCM monomers and compounds in mediating Wnt/β-catenin signaling pathway to exert anti-breast cancer effect. The statistical results showed that the flavonoids, alkaloids, and terpenoids in TCM monomers could target the Wnt/β-catenin signaling pathway and block the further development of malignant phenotype of breast cancer cells. TCM compounds with functions of clearing heat and detoxifying, promoting blood circulation and removing blood stasis, and tonifying kidney and liver were commonly used to intervene in the Wnt/β-catenin signaling pathway to prevent breast cancer. Compared with the current inhibitors of Wnt/β-catenin signaling pathway, the application of TCM monomers and compounds is expected to bring low-toxicity and high-efficiency breast cancer treatment drugs to the clinical practice, and the existing results provide a reference for the subsequent screening, research, and development of TCM small-molecule compounds and TCM compounds against breast cancer.
2.Pharmacokinetics and bioequivalence study of teriflunomide tablets in healthy Chinese subjects
Li-Li LIN ; Yan JIANG ; Qin ZHANG ; Hui-Ling QIN ; Qian ZHANG ; Yang XU ; Wei LIANG ; Lin-Ying MENG ; Zhao-Xing CHU ; Wei HU
The Chinese Journal of Clinical Pharmacology 2024;40(3):425-429
Objective To compare the pharmacokinetic profiles of the two teriflunomide tablets in healthy Chinese subjects under fasting and fed conditions and to evaluate their bioequivalence and safety.Methods A randomized,open,single-dose,parallel trial design was used to enroll 31 and 32 healthy Chinese male subjects in the fasting and fed groups,who were randomized to a single oral dose of 14 mg of either reference or test preparation of teriflunomide tablets.The plasma concentrations of teriflunomide were determined using liquid chromatography-tandem mass spectrometry method,and Phoenix WinNonlin 8.1 software was used to calculate pharmacokinetic parameters and perform bioequivalence analysis.Results Subjects received a single oral dose of the reference and test formulations of teriflunomide.The main pharmacokinetic parameters of teriflunomide in the fasting group were as follows:Cmax were(2.14±0.27)and(2.27±0.33)μg·mL-1,AUC0-72h were(105.70±11.20)and(107.72±11.77)μg·mL-1·h,tmax was 1.49 and 0.99 h;the main pharmacokinetic parameters of teriflunomide in the fed group were as follows:Cmaxwere(1.83±0.17)and(1.75±0.22)μg·mL-1,AUC0-72h were(102.66±9.18)and(101.57±13.01)μg·mL-1·h,tmax was 4.01 and 4.99 h.The 90%confidence intervals for the geometric means of Cmax and AUC0-72h for reference and test preparations in the fasting and fed groups were in the range of 80%to 125%.Conclusion The pharmacokinetic characteristics of the 2 formulations were similar under fasting and fed administration conditions,with good bioequivalence and safety;Postprandial administration may delay the time to peak of the drug.
3.Clinical trial of rivaroxaban in the treatment of anticoagulation in patients with pulmonary embolism during maintenance period
Hui QIAN ; Kui LIU ; Ya-Lin JIANG ; Xia ZHAO
The Chinese Journal of Clinical Pharmacology 2024;40(7):959-962
Objective To compare the application effect of different doses of rivaroxaban on anticoagulation therapy in patients with pulmonary thromboembolism(PTE)during maintenance period,and to evaluate its benefit-risk.Methods The patients with PTE were divided into conventional-dose group and low-dose group according to the cohort method.Conventional-dose group were given of rivaroxaban 15 mg,twice a day and changed to 20 mg once a day after 3 weeks;low-dose group were given rivaroxaban 10 mg twice a day and changed to 15 mg once a day after 3 weeks,and the anticoagulation treatment time in both groups was ≥ 3 months.The clinical efficacy in the two groups was recorded.Serum indicators[D-dimer(D-D),N-terminal pro-brain natriuretic peptide(NT-proBNP),cardiac troponin Ⅰ(cTn Ⅰ)]and liver-kidney function[glutamic-pyruvic transaminase(GPT),glutamic-oxaloacetic transaminase(GOT),blood urea nitrogen(BUN),creatinine(Cr)]were compared before treatment and after 3 months of treatment.The patients were followed up for 3 months after treatment,and the endpoint events such as PTE recurrence and death and the bleeding events were recorded in the two groups.Results There were 42 cases in conventional-dose group,44 cases in low-dose group.After 3 months of treatment,the total effective rates in low-dose group and conventional-dose group were both 100.00%,with no significant difference(P>0.05).After 3 months of treatment,serum D-D levels in low-dose group and conventional-dose group were(0.31±0.08)and(0.29±0.07)mg·L-1,NT-proBNP levels were(125.49±24.16)and(121.39±22.08)ng·L-1,cTn Ⅰ levels were(0.02±0.00)and(0.02±0.00)μg·L-1,all with significant differences(all P>0.05).There were no significant changes in GPT,GOT,BUN and Cr in the two groups before and after treatment(all P>0.05),and there were no statistically significant differences between the two groups(all P>0.05).The total incidences of bleeding events during follow-up was 6.82%in low-dose group and was 23.81%in conventional-dose group(P<0.05).Conclusion Compared with conventional-dose rivaroxaban,low-dose rivaroxaban has similar anticoagulant effect,but the latter one can better reduce the risk of bleeding events in patients with PTE.
4.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
5.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
6.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
7.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
8.Applications and advancements of instrumental variable approach in causal inference in environmental epidemiology
Hui SHI ; Guzhengyue ZHENG ; Xing ZHAO ; Shourui HUANG ; Baozhuo AI ; Jialong WU ; Hualiang LIN
Journal of Environmental and Occupational Medicine 2024;41(2):219-225
In environmental epidemiological research, extensive non-random environmental exposures and complex confounding biases pose significant challenges when attempting causal inference. In recent years, the introduction of causal inference methods into observational studies has provided a broader range of statistical tools for causal inference research in environmental epidemiology. The instrumental variable (IV) approach, as a causal inference technique for effectively controlling unmeasured confounding factors, has gradually found application in the field of environmental epidemiological research. This article reviewed the basic principles of IV and summarized the current research progress and limitations of applying IV for causal inference in environmental epidemiology. IV application in the field of environmental epidemiology is still in the initial stage. Rational use of IV and effective integration with other causal inference methods will become the focus of the development of causal inference in environmental epidemiology. The aim of this paper is to provide a methodological reference and basis for future studies involving causal inference to target population health effects of environmental exposures in China.
9.Research Progress on Efficacy-related Biomarkers of Immunotherapy in Non-small Cell Lung Cancer
Jianhong ZHENG ; Lin TIAN ; Peiyan ZHAO ; Hui LI ; Ying CHENG
Cancer Research on Prevention and Treatment 2024;51(2):127-133
Lung cancer is one of the most common cancers worldwide, and its mortality rate remains high. In addition to conventional surgery, radiotherapy, and chemotherapy, immunotherapy methods have been developed and used in recent years for the treatment of non-small cell lung cancer (NSCLC). However, only a small number of patients with NSCLC can benefit from immunotherapy strategies, and some patients even have hyperprogression after receiving immunotherapy. Therefore, precision immunotherapy requires effective biomarkers to guide it. In this paper, tissue samples, blood samples, intestinal microbiota, and other biomarkers are reviewed according to different sample sources. Blood samples, including TCR immune repertoire, Tregs cells, cytokines, lactate dehydrogenase, and other markers, are summarized and analyzed to provide reference for clinicians' diagnosis and treatment decisions.
10.Immunotherapy for Colorectal Cancer
Hao-Ran XU ; Xiao-Yi ZHAO ; He NIE ; Hui WANG ; Qing-Lin ZHANG ; Qiang ZHAN
Progress in Biochemistry and Biophysics 2024;51(10):2570-2586
Improving the prognosis of patients with colorectal cancer (CRC) holds important clinical and social significance. Immunotherapy is an emerging therapy approach for cancers, which mainly include immune checkpoint inhibitors (ICI), immune vaccine and adoptive cell therapy. ICI have achieved good clinical translation in treatment of metastatic CRC with deficient DNA mismatch repair/high microsatellite instability (dMMR/MSI-H) status. The application of some ICI, such as PD-1 inhibitors pembrolizumab and nivolumab, in this type patients have been approved by the FDA. In addition,numerous positive results are acquired in clinical trials of neoadjuvant therapy for resectable dMMR/MSI-H CRC. These results greatly bolstered the exploration enthusiasm of CRC immunotherapy. However, the proficient DNA mismatch repair/microsatellite stability (pMMR/MSS) CRC, which accounting for the vast majority in related patients, hardly benefit from ICI therapy. Various combination strategies, mainly including ICI combined with traditional chemotherapy, radiotherapy, or targeted therapy, have been attempted to alter the “cold tumors” microenvironment characteristics of pMMR/MSS CRC in clinical trials, whereas no breakthrough results were reached. Theoretically, tumor vaccines are ideal choice to break down the barrier of insufficient immune infiltration in solid tumors. However, the outcomes of related clinical trials in CRC patents are not satisfactory, and partially due to the weak specificity of the applied tumor-associated antigens. Clinical studies of adoptive cell therapy in CRC are also actively underway. The favorable efficacy of tumor-infiltrating lymphocyte, cytokine-induced killer (CIK) and dendritic cell-CIK in CRC have been confirmed, while the CAR-T and TCR-T therapies need more exploration based on screening more suitable antigens and optimizing engineering design. In this review, we made a summary based on the mainline of clinical studies related to diverse immunotherapies, so as to clarify the progress of CRC immunotherapy and provide bases for exploration of better treatment options.

Result Analysis
Print
Save
E-mail