1.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
2.Comprehensive Review on Rhodiola crenulata: Ethnopharmacology, Phytochemistry, Pharmacological Properties and Clinical Applications.
Rui ZHU ; Cui-Fen FANG ; Shu-Jing ZHANG ; Zhu HAN ; Ge-Hui ZHU ; Shang-Zuo CAI ; Cheng ZHENG ; Yu TANG ; Yi WANG
Chinese journal of integrative medicine 2025;31(8):752-759
3.Environmental sustainability in healthcare: impacts of climate change, challenges and opportunities.
Ethan Yi-Peng KOH ; Wan Fen CHAN ; Hoon Chin Steven LIM ; Benita Kiat Tee TAN ; Cherlyn Tze-Mae ONG ; Prit Anand SINGH ; Michelle Bee Hua TAN ; Marcus Jin Hui SIM ; Li Wen ONG ; Helena TAN ; Seow Yen TAN ; Wesley Chik Han HUONG ; Jonathan SEAH ; Tiing Leong ANG ; Jo-Anne YEO
Singapore medical journal 2025;66(Suppl 1):S47-S56
Environmental damage affects many aspects of healthcare, from extreme weather events to evolving population disease. Singapore's healthcare sector has the world's second highest healthcare emissions per capita, hampering the nation's pledge to reduce emissions by 2030 and achieve net zero emissions by 2050. In this review, we provide an overview of the impact environmental damage has on healthcare, including facilities, supply chain and human health, and examine measures to address healthcare's impact on the environment. Utilising the 'R's of sustainability - rethinking, reducing/refusing, reusing/repurposing/reprocessing, repairing, recycling and research - we have summarised the opportunities and challenges across medical disciplines. Awareness and advocacy to adopt strategies at institutional and individual levels is needed to revolutionise our environmental footprint and improve healthcare sustainability. By leveraging evidence from ongoing trials and integrating sustainable practices, our healthcare system can remain resilient against environment-driven challenges and evolving healthcare demands while minimising further impacts of environmental destruction.
Humans
;
Climate Change
;
Delivery of Health Care
;
Singapore
;
Conservation of Natural Resources
;
Sustainable Development
;
Environment
4.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
5.Application analysis of laparoscope in operating room
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(2):87-91
Objective To analyze the application of in-use laparoscopes in clincal departments to enhance the laparoscope's effectiveness.Methods The effective utilization data of 29 laparoscopes from January 2024 to June 2024 were acquired with an hospital intelligent medical device management platform.Comparisons were carried out in terms of average daily workload,average daily hours of use and average daily efficiency between the laparoscopes from different departments and brands with non-parametric Kruskal-Wallis test and between the conventional and 3D laparoscopes with non-parametric Mann-Whitney U test.Pearson's correlation coefficient was used to analyze the correlation between the number of years of laparoscope use and the average daily workload,the average daily hours of use,and the average daily efficiency and the chi-square test was applied to investigating the relationship between the surgery grade and the type of equipment selected.Results Thoracic sugery department had the highest average daily workload(3.82 person-time),while the general medical department had the highest average daily hours of use(443.76 min)and the highest daily efficiency(92.45%).There were significant differences between the laparoscopes from different departments in average daily workload,average daily hours of use and average daily efficiency(P<0.05).Brand D laparoscope behaved the best among brands of laparoscopes with the highest average daily workload(3.72 person-time),average daily hours of use(394.41 min)and average daily efficiency(82.17%).There were sig-nificant differences between the brands of laparoscopesin average daily workload,average daily hours of use and average daily efficiency(P<0.05).3D laparoscopes obviously gained advantages over the conventional ones in average daily workload,average daily hours of use and average daily efficiency(P<0.05).The number of years of use correlated negatively with average daily workload,average daily hours of use and average daily efficiency,with Pearson correlation coefficients being-0.095,-0.039 and-0.039 respectively.Grade Three and Four surgeries had significant differences in types of selected equipment(P<0.001),and 3D laparoscopes were preferred for Grade Four surgery.Conclusion Utilization analysis of laparoscopes provides data support for optimized application and setup of laparoscopes.[Chinese Medical Equipment Journal,2025,46(2):87-91]
6.Practical management study of anesthesia ventilators based on quality control testing data
Ming-yin JIANG ; Ya-fen GU ; Ya-bing HU ; Dun-hui LIU ; Dao-xiong WANG ; Bao-jiang HAN
Chinese Medical Equipment Journal 2025;46(9):75-80
Objective To carry out quality control testing of anesthesia ventilators to ensure the reliability and safety during their clinical use.Methods Totally 88 anesthesia ventilators used in some hospital underwent quality control testing in terms of tidal volume,peak airway pressure and positive end-expiratory pressure by using a gas flow analyzer according to JJF(E)61-2020 Calibration Specification of Anesthetic Machines,which included 31 ones,36 ones,12 ones and 9 ones respectively from brand A,B,C and D.The Kruskal-Wallis test was used to analyze the variability of the measured values and errors of the performance indicators between different brands of anesthesia ventilators,the chi-square test was applied to discussing the variability of the accuracy class of the performance indicators between different brands of anesthesia ventilators,and the Pearson correlation coefficient was adopted to investigate the correlation between the years of use and the absolute values of the relative errors of the performance indicators.Results The 88 anesthesia ventilators had the overall pass rate for quality control testing being 42.05%,of which,brand B had the highest pass rate(52.78%)and brand C had the lowest pass rate(8.33%).Brand B gained advantages in tidal volume when compared with brand A,C and D,with the differences being significant(P<0.05);brand A behaved the best in peak airway pressure and positive end-expiratory pressure when compared with brand B,C and D,with the differences being significant(P<0.05).Brand A had the highest proportion(63.08%)of distinction and credit in terms of the three performance indicators.The absolute value of the relative error in tidal volume was positively correlated with the years of use at the 3 measurement points for setting values of 400,600,and 800 mL respectively(P<0.05),and there was a significant correlation between the absolute value of the relative error and the years of use at a peak airway pressure setting of 10 cmH2O(1 cmH2O=98.07 Pa)(P<0.05).Conclusion Quality control testing of anesthesia ventilators contributes to finding the risks during their application,which can be an effective tool to ensure the safety of anesthesia ventilators used in medical institutions.[Chinese Medical Equipment Journal,2025,46(9):75-80]
7.Autosomal recessive polycystic kidney disease in a girl
Xin-Yu XU ; Qing-Mei ZHOU ; Yun-Fen TIAN ; Qiong ZHAO ; Han PAN ; Qian-Ting CHEN ; Yu-Mei LUO ; Zheng-Zheng GUO ; Tian-He LI ; Jing-Hui YANG
Chinese Journal of Contemporary Pediatrics 2024;26(9):954-960
A 5-year-old girl was admitted due to one episode of melena and one episode of hematemesis.Upon admission,gastroscopy revealed esophageal and gastric varices.Abdominal CT scan,MRI,and color Doppler ultrasound suggested cirrhosis,intrahepatic bile duct dilation,and bilateral kidney enlargement.Genetic testing identified compound heterozygous mutations in the PKHD1 gene:c.2264C>T(p.Pro755Leu)and c.1886T>C(p.Val629Ala).The c.2264C>T(p.Pro755Leu)mutation is a known pathogenic variant with previous reports,while c.1886T>C(p.Val629Ala)is a novel mutation predicted to have pathogenic potential according to Mutation Taster and PolyPhen2.The child was diagnosed with autosomal recessive polycystic kidney disease.In children presenting with gastrointestinal bleeding without obvious causes,particularly those with liver or kidney disease,consideration should be given to the possibility of autosomal recessive polycystic kidney disease,and genetic testing should be conducted for definitive diagnosis when necessary.
8.The antitussive and expectorant mechanisms of deapio-platycodin D as determined by metabolomics
Yuan-han ZHONG ; Ling-long WANG ; Zi-chao QIU ; Shao-hui ZHONG ; Xin-hong WANG ; Jin-xiang ZENG ; Xin-yu ZHANG ; Fang-yuan LIU ; Yu-jie WANG ; Gen-lin SUN ; Li-fen ZHOU ; Guo-bing WEI ; Guo-yue ZHONG
Acta Pharmaceutica Sinica 2022;57(10):3186-3194
The UHPLC-LTQ-orbitrap-MS metabolomics technique was used to determine the effect of deapio-platycodin D (DPD) on endogenous metabolites in lung tissues of mice with ammonia-induced cough, and to identify the metabolic regulatory pathways of DPD in its antitussive and expectorant activities. This work was approved by the Animal Ethics Committee of Jiangxi University of Chinese Medicine (Approval No. JZLLSC-20190235). Metabolites were identified by UHPLC-LTQ-orbitrap-MS method and the metabolic pathways related to differentially-expressed metabolites were analyzed by the MetaboAnalyst platform. DPD significantly prolonged (
9.Outcomes at discharge of preterm infants born <34 weeks' gestation.
Ning Xin LUO ; Si Yuan JIANG ; Yun CAO ; Shu Jun LI ; Jun Yan HAN ; Qi ZHOU ; Meng Meng LI ; Jin Zhen GUO ; Hong Yan LIU ; Zu Ming YANG ; Yong JI ; Bao Quan ZHANG ; Zhi Feng HUANG ; Jing YUAN ; Dan Dan PAN ; Jing Yun SHI ; Xue Feng HU ; Su LIN ; Qian ZHAO ; Chang Hong YAN ; Le WANG ; Qiu Fen WEI ; Qing KAN ; Jin Zhi GAO ; Cui Qing LIU ; Shan Yu JIANG ; Xiang Hong LIU ; Hui Qing SUN ; Juan DU ; Li HE
Chinese Journal of Pediatrics 2022;60(8):774-780
Objective: To investigate the incidence and trend of short-term outcomes among preterm infants born <34 weeks' gestation. Methods: A secondary analysis of data from the standardized database established by a multicenter cluster-randomized controlled study "reduction of infection in neonatal intensive care units (NICU) using the evidence-based practice for improving quality (REIN-EPIQ) study". This study was conducted in 25 tertiary NICU. A total of 27 192 infants with gestational age <34 weeks at birth and admitted to NICU within the first 7 days of life from May 2015 to April 2018 were enrolled. Infants with severe congenital malformation were excluded. Descriptive analyses were used to describe the mortality and major morbidities of preterm infants by gestational age groups and different admission year groups. Cochran-Armitage test and Jonckheere-Terpstra test were used to analyze the trend of incidences of mortality and morbidities in 3 study-years. Multiple Logistic regression model was constructed to analyze the differences of outcomes in 3 study-years adjusting for confounders. Results: A total of 27 192 preterm infants were enrolled with gestational age of (31.3±2.0) weeks at birth and weight of (1 617±415) g at birth. Overall, 9.5% (2 594/27 192) of infants were discharged against medical advice, and the overall mortality rate was 10.7% (2 907/27 192). Mortality for infants who received complete care was 4.7% (1 147/24 598), and mortality or any major morbidity was 26.2% (6 452/24 598). The incidences of moderate to severe bronchopulmonary dysplasia, sepsis, severe intraventricular hemorrhage or periventricular leukomalacia, proven necrotizing enterocolitis, and severe retinopathy of prematurity were 16.0% (4 342/27 192), 11.9% (3 225/27 192), 6.8% (1 641/24 206), 3.6% (939/25 762) and 1.5% (214/13 868), respectively. There was a decreasing of the overall mortality (P<0.001) during the 3 years. Also, the incidences for sepsis and severe retinopathy of prematurity both decreased (both P<0.001). However, there were no significant differences in the major morbidity in preterm infants who received complete care during the 3-year study period (P=0.230). After adjusting for confounders, infants admitted during the third study year showed significantly lower risk of overall mortality (adjust OR=0.62, 95%CI 0.55-0.69, P<0.001), mortality or major morbidity, moderate to severe bronchopulmonary dysplasia, sepsis and severe retinopathy of prematurity, compared to those admitted in the first study year (all P<0.05). Conclusions: From 2015 to 2018, the mortality and major morbidities among preterm infants in Chinese NICU decreased, but there is still space for further efforts. Further targeted quality improvement is needed to improve the overall outcome of preterm infants.
Bronchopulmonary Dysplasia/epidemiology*
;
Gestational Age
;
Humans
;
Infant
;
Infant Mortality/trends*
;
Infant, Newborn
;
Infant, Premature
;
Infant, Premature, Diseases/epidemiology*
;
Patient Discharge
;
Retinopathy of Prematurity/epidemiology*
;
Sepsis/epidemiology*
10.Prediction and verification of biological basis and mechanism for traditional Chinese drugs of reinforcing kidney for supplementing essence in treating diseases related to deficiency of kidney essence
Chao WU ; Jia-hui WEI ; Han CHEN ; Tao-ren RUAN ; Zhuo-heng LI ; Ji-fen ZHANG ; Xiao-yu XU
Acta Pharmaceutica Sinica 2020;55(3):463-472
"Kidney essence" is a profound concept in the theory of traditional Chinese medicine. But its biological basis is unknown until now, resulting in the therapeutic effects of traditional Chinese drugs on reinforcing kidney for supplementing essence hard to be evaluated. This study aimed, to explore the potential biological basis and mechanism of traditional Chinese drugs of reinforcing kidney for supplementing essence on diseases related to deficiency of kidney essence through network pharmacology analysis on the intersection of targets of drugs and diseases. The targets for ingredients in

Result Analysis
Print
Save
E-mail