1.Short-term results of transcatheter aortic valve replacement using Venus A-Plus valve delivery system in patients with severe aortic stenosis: A retrospective cohort study
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2026;33(03):438-443
Objective To evaluate the short-term efficacy of transcatheter aortic valve replacement (TAVR) using Venus A-Plus valve delivery system in patients with severe aortic stenosis. Methods The clinical data of patients undergoing TAVR in our hospital from August 2018 to March 2022 were collected and they were divided into a Venus A-Plus and a Venus A group according to the type of valve delivery system used. The perioperative data of the two groups were compared. Results A total of 121 patients were included, including 70 patients in the Venus A-Plus group [45 males and 25 females with a mean age of (67.81±6.62) years], and 51 patients in the Venus A group [33 males and 18 females with a mean age of (68.25±7.01) years]. All patients underwent TAVR, and the postoperative hemodynamic features (left ventricular ejection fraction, mean cross-valve pressure difference, peak flow rate) were significantly improved (P<0.05). There was no statistical difference in surgical success rate, all-cause mortality, conversion to thorax opening, valve-in-valve placement, moderate or above perivalvular regurgitation, new left bundle branch block or new right bundle branch block between the two groups (P>0.05). Conclusion TAVR with Venus A-Plus valve delivery system in patients with severe aortic stenosis shows comparable efficacy to the first-generation Venus A system and is satisfactory, safe and reliable.
2.Quantitative analysis of 10 components in Compound Dihuang oral solution by UPLC-MS/MS
Hongxia LIU ; Yanwen SUN ; Fei HAN ; Yan ZHOU ; Huajun SUN ; Liqin DING
Journal of Pharmaceutical Practice and Service 2025;43(8):390-394
Objective To develop an ultra-high performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method to simultaneously determine 10 main components, including berberine, phellodendrine, specnuezhenide, mangiferin, loganin, paeoniflorin, geniposide, baicalin, and acteoside in Compound Dihuang oral solution. Methods An UPLC-MS/MS method was established with an ACQUITY UPLC BEH-C18 (2.1 mm×100 mm, 1.7 μm)column and mobile phase of 0.1% formic water(A)-methanol solution(B) in a gradient elution manner. The flow rate of mobile phase was 0.2 ml/min.The temperature of column was 30℃. The injection volume was 2 μl. The MS detection was in MRM mode. Results 10 components in Compound Dihuang oral solution had a good linear relationship within their concentration range,and the precision, repeatability, stability and recovery met the requirements. The contents of berberine, phellodendrine, specnuezhenide, mangiferin, loganin, paeoniflorin, geniposide, baicalin, and acteoside in 7 batches of samples were (89.7-95.6) μg/ml, (164.0-177.7) μg/ml, (540.0-610.0) μg/ml, (408.7-429.0) μg/ml, (726.0-825.0) μg/ml, (503.7-572.0) μg/ml, (
3.New-onset conduction block after transcatheter aortic valve replacement: A retrospective analysis in a single center
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2025;32(03):372-376
Objective To investigate the new-onset conduction block after transcatheter aortic valve replacement (TAVR) and summarize the relevant experience. Methods The perioperative data of TAVR patients in the Second Hospital of Hebei Medical University from January 2016 to February 2023 were collected, and the new-onset incidence of conduction block after TAVR was analyzed retrospectively. Results Finally 352 patients were included, including 225 males and 127 females, with an average age of (67.2±5.1) years, among whom 256 patients were treated with Venus-A valves, 69 patients with Vita-Flow valves, and 27 patients with J-Valve valves. There were 38 (10.8%) patients of new-onset postoperative block. There were 6 (1.7%) patients of new-onset postoperative grade Ⅲ atrioventricular block, including 5 (2.0%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conduction function was restored in 2 patients within 14 days after surgery, and failed to be restored in 4 patients, who then received permanent pacemaker implantation in the Department of Cardiology. There were 27 (7.7%) patients of new left bundle branch block after surgery, including 22 (8.6%) patients of Venus-A, 4 (5.8%) patients of Vita-Flow and 1 (3.7%) patient of J-Valve; and conduction function was restored within 7 days after surgery in 23 patients, and 5 (1.4%) patients developed new right bundle branch blocks after surgery including 4 (1.5%) patients of Venus-A and 1 (1.4%) patient of Vita-Flow. Conclusion New-onset conduction block is a common complication after TAVR, and the new-onset rate of left bundle branch block is the highest, followed by the grade Ⅲ atrioventricular block. Mastering reasonable methods and applying appropriate strategies can effectively reduce the new-onset rate of postoperative conduction block and improve the overall success rate of TAVR surgery.
4.Application of 3D printing technology in transcatheter aortic valve replacement for bicuspid aortic stenosis
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Journal of China Medical University 2025;54(10):942-945,957
Objective To explore the value of 3D printing technology in transcatheter aortic valve replacement(TAVR)for bicuspid aortic stenosis.Methods We retrospectively analyzed the clinical data of patients who underwent TAVR for bicuspid aortic stenosis at the Department of Cardiac Surgery of the Second Hospital of Hebei Medical University between January 2020 and January 2023.Seven-ty patients were divided into 3D printing and non-3D printing groups of 35 each,based on whether or not 3D printing technology was applied,and the perioperative clinical data of the two groups were compared.Results The patients' postoperative symptoms signifi-cantly improved compared with those before the operation,and the left ventricular ejection fraction increased to varying degrees.Compared with the non-3D printing group,the operation time,X-ray irradiation time.and transvalvular time in the 3D printing group were signifi-cantly shortened,and the probabilities of the occurrence of postoperative"flap-to-flap"implantation and conduction block were signifi-cantly reduced,with statistically significant differences(P<0.05).There was no statistically significant difference(P>0.05)in the inci-dence of moderate and above perivalvular leakage,valve displacement,or conversion to thoracotomy between the two groups after surgery.Conclusion 3D printing technology can effectively guide the TAVR treatment of bicuspid aortic stenosis.While significantly shortening the operation time,it can effectively increase the success rate of TAVR and reduce the risk of adverse events,providing a new approach for the transcatheter treatment of bicuspid aortic stenosis.
5.Transcatheter edge-to-edge repair strategies for mitral commissural prolapse: a single-center experience
Xinping LIN ; Wangxing HU ; Qifeng ZHU ; Huajun LI ; Jie LIANG ; Huixiang YAN ; Lihan WANG ; Po HU ; Jubo JIANG ; Kaida REN ; Jiaqi FAN ; Yuxin HE ; Xianbao LIU ; Jian'an WANG
Chinese Journal of Cardiology 2025;53(4):356-362
Objective:To investigate the feasibility of transcatheter edge-to-edge repair (TEER) using a short-clip strategy for patients with moderate-to-severe or greater degenerative mitral regurgitation caused by commissural prolapse.Methods:This retrospective study included patients with severe mitral regurgitation secondary to commissural prolapse who underwent TEER at the Second Affiliated Hospital of Zhejiang University School of Medicine between September 2022 and July 2024. Preoperative clinical and imaging data, intraoperative details, procedural outcomes, and 1-month postoperative follow-up results were collected.Results:A total of 19 patients were enrolled, aged (74.1±6.1) years, including 12 males. Among them, 10 patients had external commissural prolapse, and 9 patients had internal commissural prolapse. Preoperatively, all patients exhibited severe mitral regurgitation (4+), with an effective regurgitant orifice area of (0.55±0.17) cm2, left atrial volume of (104.77±36.57) ml, left ventricular end-diastolic volume of (102.29±32.47) ml, left ventricular end-diastolic dimension of (5.34±0.59) mm, and prolapse width of (1.18±0.34) cm. All procedures utilized short clips (NTR or NTW clips) to target the prolapsed commissural region and were completed successfully without intraoperative complications. At 1-month follow-up, no mortality, stroke, single-leaflet device attachment, myocardial infarction, or unplanned mitral reintervention occurred. Mitral regurgitation severity improved to ≤2+ in all patients, with left atrial volume of (74.49±33.83) ml, left ventricular end-diastolic volume of (85.90±18.05) ml, and left ventricular end-diastolic dimension of (4.93±0.37) mm (all P<0.05). Conclusion:The short-clip strategy, focusing on precise clip placement at the commissural interface, is feasible and effective for TEER in patients with severe mitral regurgitation due to commissural prolapse.
6.Transcatheter edge-to-edge repair strategies for mitral commissural prolapse: a single-center experience
Xinping LIN ; Wangxing HU ; Qifeng ZHU ; Huajun LI ; Jie LIANG ; Huixiang YAN ; Lihan WANG ; Po HU ; Jubo JIANG ; Kaida REN ; Jiaqi FAN ; Yuxin HE ; Xianbao LIU ; Jian'an WANG
Chinese Journal of Cardiology 2025;53(4):356-362
Objective:To investigate the feasibility of transcatheter edge-to-edge repair (TEER) using a short-clip strategy for patients with moderate-to-severe or greater degenerative mitral regurgitation caused by commissural prolapse.Methods:This retrospective study included patients with severe mitral regurgitation secondary to commissural prolapse who underwent TEER at the Second Affiliated Hospital of Zhejiang University School of Medicine between September 2022 and July 2024. Preoperative clinical and imaging data, intraoperative details, procedural outcomes, and 1-month postoperative follow-up results were collected.Results:A total of 19 patients were enrolled, aged (74.1±6.1) years, including 12 males. Among them, 10 patients had external commissural prolapse, and 9 patients had internal commissural prolapse. Preoperatively, all patients exhibited severe mitral regurgitation (4+), with an effective regurgitant orifice area of (0.55±0.17) cm2, left atrial volume of (104.77±36.57) ml, left ventricular end-diastolic volume of (102.29±32.47) ml, left ventricular end-diastolic dimension of (5.34±0.59) mm, and prolapse width of (1.18±0.34) cm. All procedures utilized short clips (NTR or NTW clips) to target the prolapsed commissural region and were completed successfully without intraoperative complications. At 1-month follow-up, no mortality, stroke, single-leaflet device attachment, myocardial infarction, or unplanned mitral reintervention occurred. Mitral regurgitation severity improved to ≤2+ in all patients, with left atrial volume of (74.49±33.83) ml, left ventricular end-diastolic volume of (85.90±18.05) ml, and left ventricular end-diastolic dimension of (4.93±0.37) mm (all P<0.05). Conclusion:The short-clip strategy, focusing on precise clip placement at the commissural interface, is feasible and effective for TEER in patients with severe mitral regurgitation due to commissural prolapse.
7.Application of 3D printing technology in transcatheter aortic valve replacement for bicuspid aortic stenosis
Hang ZHANG ; Huajun WANG ; Fengwu SHI ; Su LIU ; Qianli MA ; Jinghui AN
Journal of China Medical University 2025;54(10):942-945,957
Objective To explore the value of 3D printing technology in transcatheter aortic valve replacement(TAVR)for bicuspid aortic stenosis.Methods We retrospectively analyzed the clinical data of patients who underwent TAVR for bicuspid aortic stenosis at the Department of Cardiac Surgery of the Second Hospital of Hebei Medical University between January 2020 and January 2023.Seven-ty patients were divided into 3D printing and non-3D printing groups of 35 each,based on whether or not 3D printing technology was applied,and the perioperative clinical data of the two groups were compared.Results The patients' postoperative symptoms signifi-cantly improved compared with those before the operation,and the left ventricular ejection fraction increased to varying degrees.Compared with the non-3D printing group,the operation time,X-ray irradiation time.and transvalvular time in the 3D printing group were signifi-cantly shortened,and the probabilities of the occurrence of postoperative"flap-to-flap"implantation and conduction block were signifi-cantly reduced,with statistically significant differences(P<0.05).There was no statistically significant difference(P>0.05)in the inci-dence of moderate and above perivalvular leakage,valve displacement,or conversion to thoracotomy between the two groups after surgery.Conclusion 3D printing technology can effectively guide the TAVR treatment of bicuspid aortic stenosis.While significantly shortening the operation time,it can effectively increase the success rate of TAVR and reduce the risk of adverse events,providing a new approach for the transcatheter treatment of bicuspid aortic stenosis.
8.Comparative Study on Flexible Ureteroscope Guided Peritoneal Dialysis Catheter Placement
Xiaozhou HAN ; Cheng ZHAO ; Jin QIU ; Jianxin LIU ; Shan LIN ; Yong ZHANG ; Changhai TIAN ; Wang LIU ; Huajun HU
Chinese Journal of Minimally Invasive Surgery 2024;24(1):29-33
Objective To explore the feasibility of peritoneal dialysis catheter placement assisted by flexible ureteroscope.Methods A retrospective analysis was conducted on clinical data of 54 cases of end-stage renal disease receiving peritoneal dialysis catheter placement from May 2019 to March 2023.The placement method was chosen by the patient.In the conventional group,23 cases were guided by a metal guide wire for insertion of the peritoneal dialysis catheter,while in the flexible ureteroscope group,31 cases were guided by flexible ureteroscope instead of guide wire for insertion of the peritoneal dialysis catheter.The success rate of catheterization,surgical time,use of postoperative analgesic,complications related to peritoneal dialysis catheter,and postoperative creatinine decrease were compared between the two groups.Results The catheter placement was successfully performed in both groups.The total incidence of complications related to peritoneal dialysis catheter in the flexible ureteroscope group was lower than that in the conventional group[6.5%(2/31)vs.30.4%(7/23),χ2 =3.878,P =0.049].Between the conventional group and the flexible ureteroscope group,there were no statistically significant differences in the surgical time,postoperative analgesic usage,and the decrease of creatinine at 2 weeks after surgery(P>0.05).The median postoperative follow-up period was10 months(range,3-24 months)in the two groups,and there were no complications such as peritoneal leakage,intestinal perforation,or intraperitoneal bleeding.Conclusion The placement of peritoneal dialysis catheter guided by the flexible ureteroscope instead of metal guide wire is a safe,visible,and accurate method,which can reduce complications related to peritoneal dialysis catheter,and detect and manage comorbidities in the abdominal cavity.
9.Efficacy of Wuling capsules combined with low-dose quetiapine in the treatment of oldest-old patients with insomnia accompanied by anxiety and depression
Chuanyun CAI ; Xin HU ; Huajun ZHU ; Wenzhu LIU ; Zixing WU ; Wei JIANG
China Pharmacy 2024;35(12):1517-1521
OBJECTIVE To investigate the efficacy and safety of Wuling capsules combined with low-dose quetiapine in the treatment of oldest-old patients with insomnia accompanied by anxiety and depression. METHODS The clinical data of 96 oldest- old patients (aged≥80 years) with insomnia accompanied by anxiety and depression who were attending outpatient clinics or hospitalized in our hospital from June 2020 to December 2022 were retrospectively analyzed. According to the different drug treatments, the patients were divided into Wuling capsules group (0.99 g, tid, 34 cases), quetiapine group (25-50 mg, qn, 30 cases) and combination group (using Wuling capsules and quetiapine simultaneously, same as the single drug groups, 32 cases). Before and after 8 weeks of treatment, the patients of three groups were compared in terms of photoplethysmography sleep monitoring indexes (total sleep duration, sleep efficiency, sleep latency, and the number of awakening), Pittsburgh sleep quality index (PSQI) score, 14-item Hamilton anxiety scale (HAMA-14) score, 17-item Hamilton depression scale (HAMD-17) score, mini-mental state examination (MMSE) score, and serum levels of interleukin-1β (IL-1β) and tumor necrosis factor-α (TNF-α); the therapeutic effects and adverse drug reactions of the three groups were observed and compared. RESULTS Compared with before treatment, the total sleep time, sleep efficiency and MMSE scores of the three groups were significantly longer or higher after treatment (P<0.05), while the sleep latency, number of awakening, PSQI score, HAMA-14 score, HAMD-17 score, serum IL-1β and TNF-α levels were significantly shorter or lower after treatment (P<0.05). Sleep latency, number of awakening, HAMA-14 score, HAMD-17 score and serum TNF-α level in quetiapine group were significantly shorter or lower than Wuling capsules group after treatment (P<0.05). Moreover, the above indexes in the combination group were significantly better than quetiapine group and Wuling capsules group (P<0.05). The total effective rate of treatment in the combination 1731786794@qq.com group was significantly higher than the other two groups (P<0.05). There was no significant difference in the incidence of mail:2408797210@qq.com adverse drug reactions among the three groups (P>0.05). CONCLUSIONS The therapeutic effect of Wuling capsules combined with low-dose quetiapine is better than that of individual drugs for oldest-old patients with insomnia accompanied with anxiety and depression, not increasing the risk of adverse reactions.
10.Short-term clinical efficacy of one-stop TAVR+PCI in the treatment of patients with aortic valve disease and coronary heart disease
Huajun WANG ; Hang ZHANG ; Tong SU ; Hongjuan LIAO ; Ziying CHEN ; Fengwu SHI ; Qianli MA ; Su LIU ; Jinghui AN
Chinese Journal of Clinical Thoracic and Cardiovascular Surgery 2024;31(06):848-852
Objective To analyze the short-term clinical efficacy and prognosis of one-stop transcatheter aortic valve replacement (TAVR)+percutaneous coronary intervention (PCI) in the treatment of aortic valve disease with coronary heart disease. Methods The clinical data of patients with aortic valve disease complicated with coronary heart disease who underwent one-stop TAVR+PCI treatment at the Department of Cardiovascular Surgery, the Second Hospital of Hebei Medical University from January 2018 to June 2023 were retrospective analyzed. The preoperative and postoperative clinical data were compared, and 1-month follow-up results were recorded. Results A total of 37 patients were enrolled, including 22 males and 15 females, with an average age of 69.14±6.47 years. Thirty-six patients recovered and were discharged after the surgery, and 1 (2.7%) patient died during the surgery. Self-expanding TAVR valves were implanted through the femoral artery in all patients. One coronary artery was opened by PCI in 35 (94.6%) patients, and two coronary arteries were opened by PCI in 2 (5.4%) patients. All PCI opened arteries had a stenosis>70%. During the postoperative hospitalization, the complications included pulmonary infection in 11 (30.6%) patients, severe pneumonia in 10 (27.8%) patients, liver function injury in 14 (38.9%) patients, renal function injury in 5 (13.9%) patients, cerebral infarction in 1 (2.8%) patient, atrial fibrillation in 1 (2.8%) patient, ventricular premature beats in 2 (5.6%) patients, atrioventricular block in 2 (5.6%) patients, and complete left bundle branch block in 5 (13.9%) patients. The median postoperative ventilation assistance time was 12.0 (0.0, 17.0) h, the ICU monitoring time was 1.0 (0.0, 2.0) d, and the postoperative hospitalization time was 5.0 (4.0, 7.0) d. There was a significant improvement in the New York Heart Association cardiac function grading after surgery (P<0.001). After surgery, there were 21 (58.3%) patients had minor perivalve leakage, 6 (16.7%) patients had minor to moderate perivalve leakage, and no moderate or above degree of perivalve leakage. After one month of postoperative follow-up, 36 patients showed significant improvement in heart function. There were no patients with recurrent acute coronary syndrome, re-PCI, or cardiovascular system disease related re-hospitalization. Conclusion The one-stop TAVR+PCI treatment for patients with aortic valve disease and coronary heart disease can obtain satisfactory short-term clinical efficacy, which is worth further trying and studying.

Result Analysis
Print
Save
E-mail