1.Optimization of simmering technology of Rheum palmatum from Menghe Medical School and the changes of chemical components after processing
Jianglin XUE ; Yuxin LIU ; Pei ZHONG ; Chanming LIU ; Tulin LU ; Lin LI ; Xiaojing YAN ; Yueqin ZHU ; Feng HUA ; Wei HUANG
China Pharmacy 2025;36(1):44-50
OBJECTIVE To optimize the simmering technology of Rheum palmatum from Menghe Medical School and compare the difference of chemical components before and after processing. METHODS Using appearance score, the contents of gallic acid, 5-hydroxymethylfurfural (5-HMF), sennoside A+sennoside B, combined anthraquinone and free anthraquinone as indexes, analytic hierarchy process (AHP)-entropy weight method was used to calculate the comprehensive score of evaluation indicators; the orthogonal experiment was designed to optimize the processing technology of simmering R. palmatum with fire temperature, simmering time, paper layer number and paper wrapping time as factors; validation test was conducted. The changes in the contents of five anthraquinones (aloe-emodin, rhein, emodin, chrysophanol, physcion), five anthraquinone glycosides (barbaloin, rheinoside, rhubarb glycoside, emodin glycoside, and emodin methyl ether glycoside), two sennosides (sennoside A, sennoside B), gallic acid and 5-HMF were compared between simmered R. palmatum prepared by optimized technology and R. palmatum. RESULTS The optimal processing conditions of R. palmatum was as follows: each 80 g R. palmatum was wrapped with a layer of wet paper for 0.5 h, simmered on high heat for 20 min and then simmered at 140 ℃, the total simmering time was 2.5 h. The average comprehensive score of 3 validation tests was 94.10 (RSD<1.0%). After simmering, the contents of five anthraquinones and two sennosides were decreased significantly, while those of 5 free anthraquinones and gallic acid were increased to different extents; a new component 5-HMF was formed. CONCLUSIONS This study successfully optimizes the simmering technology of R. palmatum. There is a significant difference in the chemical components before and after processing, which can explain that simmering technology slows down the relase of R. palmatum and beneficiate it.
2.Effects of protopanaxadiol on the proliferation and apoptosis of human ovarian cancer cells HO-8910 through regulation
Rui-Hua NIE ; Wei ZHU ; Jin-Yan LUO
The Chinese Journal of Clinical Pharmacology 2024;40(12):1769-1773
Objective To investigate the effect of propanaxanediol on proliferation and apoptosis of human ovarian cancer cell HO-8910 and analyze the mechanism.Methods Human ovarian cancer cell HO-8910 were randomly divided into blank group(0.9%NaCl)and experimental-L,-M,-H groups(25,50,100 mg·kg-1 propanaxanadiol treated cells,respectively).Cell counting kit-8(CCK-8)was used to detect the proliferation inhibition;the apoptosis was detected by flow cytometry;the migration was detected by cell scratch test;the invasion was detected by Transwell assay;the expression levels of phosphatidylinositol 3 kinase(PI3K),phosphorylated protein kinase B(p-AKT),proliferating cell nuclear antigen(PCNA),B cell lymphoma-2(Bcl-2)and Bcl-2 associated X protein(Bax)were detected by Western blot.Results The proliferation inhibition rates of blank group and experimental-L,-M,-H groups were(16.89±4.15)%,(28.43±3.66)%,(37.96±4.98)%and(50.11±5.24)%;the apoptosis rates were(4.23±1.07)%,(12.36±2.79)%,(24.32±2.93)%and(42.40±3.28)%;the expression levels of PCNA protein were 0.85±0.08,0.69±0.06,0.43±0.06 and 0.25±0.03;the expression levels of Bax protein were 0.18±0.03,0.33±0.04,0.50±0.05 and 0.69±0.05;the expression levels of Bcl-2 protein were 0.82±0.07,0.63±0.04,0.47±0.05 and 0.30±0.03;the mobility were(52.33±4.25)%,(40.16±4.03)%,(29.63±3.25)%and(20.15±2.12)%;the invasion rates were(60.26±5.88)%,(49.33±4.28)%,(30.15±3.68)%and(22.15±1.96)%;the expression levels of PI3K protein were 0.48±0.04,0.34±0.04,0.26±0.03 and 0.15±0.01;the expression levels of p-AKT protein were 0.45±0.03,0.35±0.02,0.23±0.03 and 0.13±0.02,respectively.There were statistically significant differences in the above indexes between the experimental-L,-M,-H groups and the blank group(all P<0.05).Conclusion Protopanaxadiol may inhibit the proliferation,migration and invasion of human ovarian cancer cell HO-8910 by blocking the activation of PI3K/AKT signaling pathway,regulating the expression of PCNA,Bax and Bcl-2 proteins and promoting their apoptosis,thus achieving anti-ovarian cancer effects.
3.Construction of blood quality monitoring indicator system in blood banks of Shandong
Qun LIU ; Xuemei LI ; Yuqing WU ; Zhiquan RONG ; Zhongsi YANG ; Zhe SONG ; Shuhong ZHAO ; Lin ZHU ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xiaojuan FAN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):249-257
【Objective】 To establish a blood quality monitoring indicator system, in order to continuously improve blood quality and standardized management. 【Methods】 Based on the research of literature and standards, and guided by the key control points of blood collection and supply process, the blood quality monitoring indicator system was developed. Through two rounds of Delphi expert consultation, the indicator content was further revised and improved according to expert opinions after six months of trial implementation. The indicator weight was calculated by questionnaire and analytic hierarchy process. 【Results】 A blood quality monitoring indicator system covering the whole process of blood collection and supply was constructed, including five primary indicators, namely blood donation service, blood component preparation, blood testing, blood supply and quality control, as well as 72 secondary indicators, including definitions, calculation formulas, etc. Two rounds of expert consultation and two rounds of feasibility study meeting were held to revise 17 items and the weight of each indicator was obtained through the analytic hierarchy process. After partial adjustments, a blood quality monitoring indicator system was formed. 【Conclusion】 A blood quality monitoring indicator system covering the whole process of blood collection and supply has been established for the first time, which can effectively evaluate the quality management level of blood banks and coordinate blood quality control activities of blood banks in Shandong like pieces in a chess game, thus improving the standardized management level
4.Application of quality monitoring indicators of blood testing in blood banks of Shandong province
Xuemei LI ; Weiwei ZHAI ; Zhongsi YANG ; Shuhong ZHAO ; Yuqing WU ; Qun LIU ; Zhe SONG ; Zhiquan RONG ; Shuli SUN ; Xiaojuan FAN ; Wei ZHANG ; Jinyu HAN ; Lin ZHU ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):258-266
【Objective】 To objectively evaluate the quality control level of blood testing process in blood banks through quantitative monitoring and trend analysis, and to promote the homogenization level and standardized management of blood testing laboratories in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation service, blood component preparation, blood testing, blood supply and quality control was established. The questionnaire Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong province. Quality monitoring indicators of each blood bank from January to December 2022 were collected, and 31 indicators in terms of blood testing were analyzed using SPSS25.0 software. 【Results】 The proportion of unqualified serological tests in 17 blood bank laboratories was 55.84% for ALT, 13.63% for HBsAg, 5.08% for anti HCV, 5.62% for anti HIV, 18.18% for anti TP, and 1.65% for other factors (mainly sample quality). The detection unqualified rate and median were (1.23±0.57)% and 1.11%, respectively. The ALT unqualified rate and median were (0.74±0.53)% and 0.60%, respectively. The detection unqualified rate was positively correlated with ALT unqualified rate (r=0.974, P<0.05). The unqualified rate of HBsAg, anti HCV, anti HIV and anti TP was (0.15±0.09)%, (0.05±0.04)%, (0.06±0.03)% and (0.20±0.05)% respectively. The average unqualified rate, average hemolysis rate, average insufficient volume rate and the abnormal hematocrit rate of samples in 17 blood bank laboratories was 0.21‰, 0.08‰, 0.01‰ and 0.02‰ respectively. There were differences in the retest concordance rates of four HBsAg, anti HCV and anti HIV reagents, and three anti TP reagents among 17 blood bank laboratories (P<0.05). The usage rate of ELISA reagents was (114.56±3.30)%, the outage rate of ELISA was (10.23±7.05) ‰, and the out of range rate of ELISA was (0.90±1.17) ‰. There was no correlation between the out of range rate, outrage rate and usage rate (all P>0.05), while the outrage rate was positively correlated with the usage rate (r=0.592, P<0.05). A total of 443 HBV DNA positive samples were detected in all blood banks, with an unqualified rate of 3.78/10 000; 15 HCV RNA positive samples were detected, with an unqualified rate of 0.13/10 000; 5 HIV RNA positive samples were detected, with an unqualified rate of 0.04/10 000. The unqualified rate of NAT was (0.72±0.04)‰, the single NAT reaction rate [(0.39±0.02)‰] was positively correlated with the single HBV DNA reaction rate [ (0.36±0.02) ‰] (r=0.886, P<0.05). There was a difference in the discriminated reactive rate by individual NAT among three blood bank laboratories (C, F, H) (P<0.05). The median resolution rate of 17 blood station laboratories by minipool test was 36.36%, the median rate of invalid batch of NAT was 0.67%, and the median rate of invalid result of NAT was 0.07‰. The consistency rate of ELISA dual reagent detection results was (99.63±0.24)%, and the median length of equipment failure was 14 days. The error rate of blood type testing in blood collection department was 0.14‰. 【Conclusion】 The quality monitoring indicator system for blood testing process in Shandong can monitor potential risks before, during and after the experiment, and has good applicability, feasibility, and effectiveness, and can facilitate the continuous improvement of laboratory quality control level. The application of blood testing quality monitoring indicators will promote the homogenization and standardization of blood quality management in Shandong, and lay the foundation for future comprehensive evaluations of blood banks.
5.Application of quality control indicator system in blood banks of Shandong
Qun LIU ; Yuqing WU ; Xuemei LI ; Zhongsi YANG ; Zhe SONG ; Zhiquan RONG ; Shuhong ZHAO ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Xuejing LI ; Bo ZHOU ; Chenxi YANG ; Haiyan HUANG ; Guangcai LIU ; Kai CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):267-274
【Objective】 To establish an effective quality monitoring indicator system for blood quality control in blood banks, in order to analyze the quality control indicators for blood collection and supply, and evaluate blood quality control process, thus promoting continuous improvement and standardizing management of blood quality control in blood banks. 【Methods】 A quality monitoring indicator system covering the whole process of blood collection and supply, including blood donation services, component preparation, blood testing, blood supply and quality control was established. The Questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process was distributed to 17 blood banks in Shandong, which clarified the definition and calculation formula of indicators. The quality monitoring indicator data from January to December 2022 in each blood bank were collected, and 20 quality control indicators data were analyzed by SPSS25.0 software. 【Results】 The average pass rate of key equipment monitoring, environment monitoring, key material monitoring, and blood testing item monitoring of 17 blood banks were 99.47%, 99.51%, 99.95% and 98.99%, respectively. Significant difference was noticed in the pass rate of environment monitoring among blood banks of varied scales(P<0.05), and the Pearson correlation coefficient (r) between the total number of blood quality testing items and the total amount of blood component preparation was 0.645 (P<0.05). The average discarding rates of blood testing or non-blood testing were 1.14% and 3.36% respectively, showing significant difference among blood banks of varied scales (P<0.05). The average discarding rate of lipemic blood was 3.07%, which had a positive correlation with the discarding rate of non testing (r=0.981 3, P<0.05). There was a statistically significant difference in the discarding rate of lipemic blood between blood banks with lipemic blood control measures and those without (P<0.05). The average discarding rate of abnormal color, non-standard volume, blood bag damage, hemolysis, blood protein precipitation and blood clotting were 0.20%, 0.14%, 0.06%, 0.06%, 0.02% and 0.02% respectively, showing statistically significant differences among large, medium and small blood banks(P<0.05).The average discarding rates of expired blood, other factors, confidential unit exclusion and unqualified samples were 0.02%, 0.05%, 0.003% and 0.004%, respectively. The discarding rate of blood with air bubbles was 0.015%, while that of blood with foreign body and unqualified label were 0. 【Conclusion】 The quality control indicator system of blood banks in Shandong can monitor weak points in process management, with good applicability, feasibility, and effectiveness. It is conducive to evaluate different blood banks, continuously improve the quality control level of blood collection and supply, promote the homogenization and standardization of blood quality management, and lay the foundation for comprehensive evaluation of blood banks in Shandong.
6.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
7.Efficacy of different concentrations of ZKY001 eyedrops in the treatment of corneal epithelial defect after primary pterygium excision
Hua GAO ; Lei ZHU ; Jianjiang XU ; Liming TAO ; Yanling DONG ; Luxia CHEN ; Xiuming JIN ; Guigang LI ; Huping WU ; Ping ZHAO ; Wei CHEN ; Xiaoyi LI ; Weiyun SHI
International Eye Science 2024;24(12):1888-1894
AIM: To investigate the efficacy and safety of ZKY001 eye drops with different concentrations in the treatment of corneal epithelial defects(CED)after primary pterygium excision.METHODS: This was a multicenter, randomized, double-blinded, placebo-controlled phase II clinical trial. From March 15, 2022 to November 14, 2022, patients with primary pterygium who had undergone surgery were recruited from 12 tertiary hospitals across China. Using block randomization, 178 patients(178 eyes)were randomly assigned to 3 groups in a 1:1:1 ratio: 0.002% ZKY001 group(n=59), 0.004% ZKY001 group(n=59), and placebo group(n=60, receiving ZKY001 sham eye drops). Subjects in each group received 1 drop of the study drug 4 times per day for 4 d. The percentage of CED area recovery from baseline, the first complete healing time of CED area, the number of first complete healing cases of CED, and changes in visual analogue scale(VAS)scores for eye discomfort including eye pain, foreign body sensation, tearing and photophobia were observed.RESULTS: In terms of improvement in CED, there were no statistically significant differences among the three groups including the first healing time of CED, the percentage improvement in CED area compared to baseline, and the percentage of first healing cases at different follow-up visits(all P>0.05). Numerically, the first healing time of CED was shorter in the test groups compared to the placebo group(67.87±21.688 h for the 0.002% ZKY001 group, 61.48±22.091 h for the 0.004% ZKY001 group, and 68.85±20.851 h for the placebo group). On D1 morning, the percentage improvement in CED area compared to baseline was maximally different from the placebo group, and the numerical difference advantage was maintained at subsequent follow-up visits. The number of first healing cases in the CED area at different follow-up visits was higher in the test groups than the placebo group. In terms of improvement in ocular discomfort, the total VAS scores were lower in the test groups compared to the placebo group, mainly due to reductions in foreign body sensation and pain scores. At D3, the 0.004% ZKY001 group showed statistically significant improvement in foreign body sensation(P<0.017). In terms of safety, the overall incidence of adverse events was low(9.0%)and similar among groups.CONCLUSION: The use of ZKY001 eyedrops after primary pterygium surgery can safely improve the CED repair, and alleviate postoperative symptoms caused by CED.
8.Preparation of soluble microneedle patch with fusion protein nanoparticles secreted by Mycobacterium tuberculosis and application of tuberculosis skin test
Fan CHEN ; Rong-sheng ZHU ; Jing ZHOU ; Yue HU ; Yun XUE ; Jian-hua KANG ; Wei WANG
Acta Pharmaceutica Sinica 2024;59(6):1804-1811
Rapid epidemiological screening for tuberculosis (TB) usually uses tuberculin pure protein derivative (PPD) skin test, which has limitations such as low specificity and high side effects. ESAT-6 and CFP-10 are secreted proteins of
9.Effects of template and pore-forming agent method on the structure and drug delivery of porous maltodextrin
Zhe LI ; Xiao-sui LUO ; Wei-feng ZHU ; Qiong LI ; Yong-mei GUAN ; Zheng-ji JIN ; Li-hua CHEN ; Liang-shan MING
Acta Pharmaceutica Sinica 2024;59(8):2381-2395
This study using maltodextrin as raw material, 1%-5% polyvinylpyrrolidone K30 as template agent, 1%-5% ammonium bicarbonate as pore-forming agent, curcumin and ibuprofen as model drugs. Porous maltodextrin was prepared by template and pore-forming agent methods, respectively. The structure and drug delivery behavior of porous maltodextrin prepared by different technologies were comprehensively characterized. The results showed that the porous maltodextrin prepared by pore-forming agent method had larger specific surface area (6.449 4 m2·g-1) and pore size (32.804 2 nm), which was significantly better than that by template agent method (3.670 2 m2·g-1, 15.278 5 nm). The adsorption kinetics between porous maltodextrin prepared by pore-forming agent method and curcumin were suitable for quasi-first order adsorption kinetic model, and that between porous maltodextrin and ibuprofen were suitable for quasi-second order adsorption kinetic model. While the adsorption kinetics between porous maltodextrin prepared by template agent method and two model drugs were both suitable for the quasi-first order adsorption kinetic model. In addition, the dissolution behavior analysis showed that the porous maltodextrin prepared by the two technologies can significantly improve the dissolution behavior of insoluble drugs, and the drug release was both carried out by diffusion mechanism, which suitable for the Peppas kinetic release model, but the porous maltodextrin prepared by template agent method had a faster release rate. The change of nozzle diameter had no significant effect on the adsorption process and drug release behavior of porous maltodextrin. In conclusion, the porous maltodextrins prepared by two different technologies were both beneficial to the delivery of insoluble drugs, and the template agent method was the best for delivery of insoluble drugs. This study can provide theoretical basis for the preparation of porous particles, promote the application of porous particles in insoluble drugs, and improve the bioavailability of insoluble drugs.
10.Two new dalbergiphenols from Zhuang medicine Dalbergia rimosa Roxb
Cheng-sheng LU ; Wei-yu WANG ; Min ZHU ; Si-si QIN ; Zhao-hui LI ; Chen-yan LIANG ; Xu FENG ; Jian-hua WEI
Acta Pharmaceutica Sinica 2024;59(2):418-423
Twelve compounds were isolated from the ethyl acetate fraction of the 80% aqueous ethanol extract of the roots and stems of

Result Analysis
Print
Save
E-mail