1.Digital study on proximal clavicle anatomical plate based on 3D printing technology
Yi ZHENG ; Xing-Guo ZHENG ; Jia-Kai ZHANG ; Jun-Long WU ; Xin-Hua YUAN
China Journal of Orthopaedics and Traumatology 2024;37(3):278-280
Objective To explore feasibility of 3D metal printing technology combined with virtual design proximal clavicle anatomical plate.Methods A 52-year-old male healthy volunteer was retrospectively selected to design proximal clavicle anatomical plate system by using Mimics15.01,NX12.0 and other software.STL data were input into 3D printer to print 1∶1 clavicle model and proximal clavicle anatomical plate.The fit of the plate was tested in vitro and the accuracy of screw position was evaluated by imaging.Printing time of model,nail path design and fabrication time of the anatomical plate at proximal clavicle were recorded.Results The 3D metal printing proximal clavicle anatomical plate fitted well to clavicle model,orienta-tion of proximal clavicle locking screw was accurate,and X-ray and CT scan showed the screw position was good.Printing time of model,the time of nail path design,and the time of making anatomical plate of proximal clavicle were 120,15 and 300 min respectively.Conclusion The proximal clavicular anatomical plate system based on 3D metal printing technology could achieve good lamination of proximal clavicular fracture plate and precise screw placement,providing a new and accurate surgical method for the treatment of the proximal clavicular fracture.
2.Finite element analysis of anatomic plate fixation for proximal clavicular fractures
Yi ZHENG ; Jia-Kai ZHANG ; Jun-Long WU ; Xin-Hua YUAN
China Journal of Orthopaedics and Traumatology 2024;37(9):917-920
Objective To explore establishment and finite element analysis of personalized proximal clavicular anatomical plate screw fixation model.Methods A 40-year-old male healthy volunteer was selected and the finite element analysis modules of 3D reconstruction software Mimics 15.01,Hypermesh 2019 and Abaqus 2020 were used.The finite element model of anatomic plate at the proximal clavicle was established,and a vertical load of 250 N was applied to the distal end of long axis of clavicle about 15 mm,then the overall structure,plate and screw displacement cloud image,Mises stress distribution were ob-served.Results The displacement distribution of the overall structure shows the maximum displacement was distributed on the distal clavicle.Under the four conditions of normal upper limb weight,longitudinal clavicle fracture,oblique fracture and shoulder impact violence during fall,longitudinal clavicle fracture and oblique fracture,the maximum displacement were 1.04 mm,1.03 mm,1.35 mm and 1.33 mm,respectively.The displacement cloud map of titanium alloy steel plate showed the largest displacement was distributed near the distal clavicular bone,and the maximum displacement were 0.89 mm,0.88 mm,1.10 mm and 1.09 mm,respectively.The displacement cloud map of titanium alloy screw showed the largest displacement was distribut-ed at the root of the distal screw,and the maximum displacement were 0.88 mm,0.87 mm,1.08 mm and 1.06 mm,respectively.Mises stress distribution showed the maximum stress was mainly distributed on titanium alloy plates and screws,and the stress on the clavicle was very small.Mises stress distribution cloud showed the maximum Mises stress was distributed at the second row of screw holes near the clavicle,and the maximum Mises stress were 673.1,678.1,648.5,654.4 MPa,respectively.The maximum stresses of titanium alloy screws were 414.5,417.4,415.8 and 419.7 MPa,respectively.Conclusion The biomechan-ical changes of personalized proximal clavicular anatomical plates are demonstrated by using 3D finite element method to pro-vide biomechanical data for personalized proximal clavicular anatomical plates.
3.Practice of the construction of China hospital research integrity alliance
Zhuojing ZHANG ; Jing XUE ; Wenyi LI ; Jun NING ; Peiwu HU ; Jing YU ; Zhuoqing WANG ; Zheng WANG ; Hua GUO
Chinese Journal of Hospital Administration 2024;40(5):362-366
Research integrity is the foundation for ensuring the sound and orderly development of scientific and technological innovation. As the main battlefield of clinical medical research, hospitals should effectively fulfill their main responsibilities and do a good job in research integrity management. The China Hospital Research Integrity Alliance, consisting of the first batch of 43 hospitals, was established in November 2021. With the aim of " complementary advantages, resource sharing, and collaborative development", the alliance has carried out construction practices from seven aspects: construction mode, cultural system construction, organizational management, institutional construction, publicity and education, early warning and supervision, and technological empowerment. It has achieved the overall improvement of the research integrity construction ability of member units of the alliance, organic linkage between government and medical institutions, and efficient combination of internal and external resources, which can provide reference for the research integrity construction of medical institutions in China.
4.Design and experimental study of wearable cardiopulmonary monitoring system
Wan-Jun SHUAI ; Shu-Li ZHAO ; Wen-Zhe LI ; Hua-Yong GAO ; Jian JIANG ; Xi CHEN ; Jin-Hua YANG ; Yong CHAO ; Zheng-Tao CAO
Chinese Medical Equipment Journal 2024;45(4):51-55
Objective To design a wearable cardiopulmonary monitoring system and validate its performance through preliminary human trials.Methods The wearable cardiopulmonary monitoring system was composed of a data collector,a wearing vest and an information management platform.The data collector used an EFM32GG330 SCM as the main microcon-troller unit(MCU),which included a respiratory modulation module,an ECG modulation module,a body position modulation module,a wireless communication module(involving in a Bluetooth module and a Wi-Fi module),a storage module and a power management module.The wearable vest had a cardigan-type structure,and was equipped with ECG sensors and respiratory motion sensors at its inner side.The information management platform was developed with Client/Server(C/S)architecture and Java/JavaScript.The system developed was compared with Mindray's IPM10 Patient Monitor routinely used in hospitals through preliminary human trials to verify its effectiveness in monitoring human heart rate and respiratory rate.Results The system developed could continuously monitor the human heart rate and respiratory rate for a long time,and the monitoring results had high consistency with those of Mindray's IPM10 Patient Monitor.Conclusion The system can be used for medical monitoring of cardiopulmonary indicators during training or exercise,providing accurate physiological information for health management.[Chinese Medical Equipment Journal,2024,45(4):51-55]
5.A multi-center epidemiological study on pneumococcal meningitis in children from 2019 to 2020
Cai-Yun WANG ; Hong-Mei XU ; Gang LIU ; Jing LIU ; Hui YU ; Bi-Quan CHEN ; Guo ZHENG ; Min SHU ; Li-Jun DU ; Zhi-Wei XU ; Li-Su HUANG ; Hai-Bo LI ; Dong WANG ; Song-Ting BAI ; Qing-Wen SHAN ; Chun-Hui ZHU ; Jian-Mei TIAN ; Jian-Hua HAO ; Ai-Wei LIN ; Dao-Jiong LIN ; Jin-Zhun WU ; Xin-Hua ZHANG ; Qing CAO ; Zhong-Bin TAO ; Yuan CHEN ; Guo-Long ZHU ; Ping XUE ; Zheng-Zhen TANG ; Xue-Wen SU ; Zheng-Hai QU ; Shi-Yong ZHAO ; Lin PANG ; Hui-Ling DENG ; Sai-Nan SHU ; Ying-Hu CHEN
Chinese Journal of Contemporary Pediatrics 2024;26(2):131-138
Objective To investigate the clinical characteristics and prognosis of pneumococcal meningitis(PM),and drug sensitivity of Streptococcus pneumoniae(SP)isolates in Chinese children.Methods A retrospective analysis was conducted on clinical information,laboratory data,and microbiological data of 160 hospitalized children under 15 years old with PM from January 2019 to December 2020 in 33 tertiary hospitals across the country.Results Among the 160 children with PM,there were 103 males and 57 females.The age ranged from 15 days to 15 years,with 109 cases(68.1% )aged 3 months to under 3 years.SP strains were isolated from 95 cases(59.4% )in cerebrospinal fluid cultures and from 57 cases(35.6% )in blood cultures.The positive rates of SP detection by cerebrospinal fluid metagenomic next-generation sequencing and cerebrospinal fluid SP antigen testing were 40% (35/87)and 27% (21/78),respectively.Fifty-five cases(34.4% )had one or more risk factors for purulent meningitis,113 cases(70.6% )had one or more extra-cranial infectious foci,and 18 cases(11.3% )had underlying diseases.The most common clinical symptoms were fever(147 cases,91.9% ),followed by lethargy(98 cases,61.3% )and vomiting(61 cases,38.1% ).Sixty-nine cases(43.1% )experienced intracranial complications during hospitalization,with subdural effusion and/or empyema being the most common complication[43 cases(26.9% )],followed by hydrocephalus in 24 cases(15.0% ),brain abscess in 23 cases(14.4% ),and cerebral hemorrhage in 8 cases(5.0% ).Subdural effusion and/or empyema and hydrocephalus mainly occurred in children under 1 year old,with rates of 91% (39/43)and 83% (20/24),respectively.SP strains exhibited complete sensitivity to vancomycin(100% ,75/75),linezolid(100% ,56/56),and meropenem(100% ,6/6).High sensitivity rates were also observed for levofloxacin(81% ,22/27),moxifloxacin(82% ,14/17),rifampicin(96% ,25/26),and chloramphenicol(91% ,21/23).However,low sensitivity rates were found for penicillin(16% ,11/68)and clindamycin(6% ,1/17),and SP strains were completely resistant to erythromycin(100% ,31/31).The rates of discharge with cure and improvement were 22.5% (36/160)and 66.2% (106/160),respectively,while 18 cases(11.3% )had adverse outcomes.Conclusions Pediatric PM is more common in children aged 3 months to under 3 years.Intracranial complications are more frequently observed in children under 1 year old.Fever is the most common clinical manifestation of PM,and subdural effusion/emphysema and hydrocephalus are the most frequent complications.Non-culture detection methods for cerebrospinal fluid can improve pathogen detection rates.Adverse outcomes can be noted in more than 10% of PM cases.SP strains are high sensitivity to vancomycin,linezolid,meropenem,levofloxacin,moxifloxacin,rifampicin,and chloramphenicol.[Chinese Journal of Contemporary Pediatrics,2024,26(2):131-138]
6.Antimicrobial resistance of bacteria from blood specimens:surveillance re-port from Hunan Province Antimicrobial Resistance Surveillance System,2012-2021
Hong-Xia YUAN ; Jing JIANG ; Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Xing-Wang NING ; Jun LIU ; Guo-Min SHI ; Man-Juan TANG ; Jing-Min WU ; Huai-De YANG ; Ming ZHENG ; Jie-Ying ZHOU ; Nan REN ; An-Hua WU ; Xun HUANG
Chinese Journal of Infection Control 2024;23(8):921-931
Objective To understand the change in distribution and antimicrobial resistance of bacteria isolated from blood specimens of Hunan Province,and provide for the initial diagnosis and treatment of clinical bloodstream infection(BSI).Methods Data reported from member units of Hunan Province Antimicrobial Resistance Survei-llance System from 2012 to 2021 were collected.Bacterial antimicrobial resistance surveillance method was imple-mented according to the technical scheme of China Antimicrobial Resistance Surveillance System(CARSS).Bacteria from blood specimens and bacterial antimicrobial susceptibility testing results were analyzed by WHONET 5.6 soft-ware and SPSS 27.0 software.Results A total of 207 054 bacterial strains were isolated from blood specimens from member units in Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021,including 107 135(51.7%)Gram-positive bacteria and 99 919(48.3%)Gram-negative bacteria.There was no change in the top 6 pathogenic bacteria from 2012 to 2021,with Escherichia coli(n=51 537,24.9%)ranking first,followed by Staphylococcus epidermidis(n=29 115,14.1%),Staphylococcus aureus(n=17 402,8.4%),Klebsiella pneu-moniae(17 325,8.4%),Pseudomonas aeruginosa(n=4 010,1.9%)and Acinetobacter baumannii(n=3 598,1.7%).The detection rate of methicillin-resistant Staphylococcus aureus(MRSA)decreased from 30.3%in 2015 to 20.7%in 2021,while the detection rate of methicillin-resistant coagulase-negative Staphylococcus(MRCNS)showed an upward trend year by year(57.9%-66.8%).No Staphylococcus was found to be resistant to vancomy-cin,linezolid,and teicoplanin.Among Gram-negative bacteria,constituent ratios of Escherichia coli and Klebsiella pneumoniae were 43.9%-53.9%and 14.2%-19.5%,respectively,both showing an upward trend(both P<0.001).Constituent ratios of Pseudomonas aeruginosa and Acinetobacter baumannii were 3.6%-5.1%and 3.0%-4.5%,respectively,both showing a downward trend year by year(both P<0.001).From 2012 to 2021,resistance rates of Escherichia coli to imipenem and ertapenem were 1.0%-2.0%and 0.6%-1.1%,respectively;presenting a downward trend(P<0.001).The resistant rates of Klebsiella pneumoniae to meropenem and ertapenem were 7.4%-13.7%and 4.8%-6.4%,respectively,presenting a downward trend(both P<0.001).The resistance rates of Pseudomonas aeruginosa and Acinetobacter baumannii to carbapenem antibiotics were 7.1%-15.6%and 34.7%-45.7%,respectively.The trend of resistance to carbapenem antibiotics was relatively stable,but has de-creased compared with 2012-2016.The resistance rates of Escherichia coli to the third-generation cephalosporins from 2012 to 2021 were 41.0%-65.4%,showing a downward trend year by year.Conclusion The constituent ra-tio of Gram-negative bacillus from blood specimens in Hunan Province has been increasing year by year,while the detection rate of carbapenem-resistant Gram-negative bacillus remained relatively stable in the past 5 years,and the detection rate of coagulase-negative Staphylococcus has shown a downward trend.
7.Antimicrobial resistance of bacteria from cerebrospinal fluid specimens:surveillance report from Hunan Province Antimicrobial Resistance Survei-llance System,2012-2021
Jun LIU ; Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Xing-Wang NING ; Guo-Min SHI ; Jing-Min WU ; Huai-De YANG ; Hong-Xia YUAN ; Ming ZHENG ; Nan REN ; An-Hua WU ; Xun HUANG ; Man-Juan TANG
Chinese Journal of Infection Control 2024;23(8):932-941
Objective To investigate changes in the distribution and antimicrobial resistance of bacteria isolated from cerebrospinal fluid(CSF)specimens in Hunan Province,and provide reference for correct clinical diagnosis and rational antimicrobial use.Methods Data reported by member units of Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021 were collected according to China Antimicrobial Resistance Surveillance Sys-tem(CARSS)technical scheme.Data of bacteria isolated from CSF specimens and antimicrobial susceptibility tes-ting results were analyzed with WHONET 5.6 and SPSS 20.0 software.Results A total of 11 837 bacterial strains were isolated from CSF specimens from member units of Hunan Province Antimicrobial Resistance Surveillance Sys-tem from 2012 to 2021.The top 5 strains were coagulase-negative Staphylococcus(n=6 397,54.0%),Acineto-bacter baumannii(n=764,6.5%),Staphylococcus aureus(n=606,5.1%),Enterococcus faecium(n=465,3.9%),and Escherichia coli(n=447,3.8%).The detection rates of methicillin-resistant coagulase-negative Staphyloco-ccus(MRCNS)and methicillin-resistant Staphylococcus aureus(MRSA)were 58.9%-66.3%and 34.4%-62.1%,respectively.No Staphylococcus spp.were found to be resistant to vancomycin,linezolid,and teicoplanin.The de-tection rate of Enterococcus faecium was higher than that of Enterococcus faecalis,and the resistance rates of En-terococcus f aecium to penicillin,ampicillin,high concentration streptomycin and levofloxacin were all higher than those of Enterococcus faecalis(all P=0.001).Resistance rate of Streptococcus pneumoniae to penicillin was 85.0%,at a high level.Resistance rate of Escherichia coli to ceftriaxone was>60%,while resistance rates to enzyme inhibitors and carbapenem antibiotics were low.Resistance rate of Klebsiella pneumoniae to ceftriaxone was>60%,to en-zyme inhibitors piperacillin/tazobactam and cefoperazone/sulbactam was>30%,to carbapenem imipenem and me-ropenem was about 30%.Resistance rates of Acinetobacter baumannii to most tested antimicrobial agents were>60%,to imipenem and meropenem were 59.0%-79.4%,to polymyxin B was low.Conclusion Among the bac-teria isolated from CSF specimens,coagulase-negative Staphylococcus accounts for the largest proportion,and the overall resistance of pathogenic bacteria is relatively serious.Bacterial antimicrobial resistance surveillance is very important for the effective treatment of central nerve system infection.
8.Antimicrobial resistance of bacteria from intensive care units:surveillance report from Hunan Province Antimicrobial Resistance Surveillance Sys-tem,2012-2021
Li-Hua CHEN ; Chen-Chao FU ; Chen LI ; Yan-Ming LI ; Jun LIU ; Xing-Wang NING ; Guo-Min SHI ; Jing-Min WU ; Huai-De YANG ; Hong-Xia YUAN ; Ming ZHENG ; Nan REN ; Xun HUANG ; An-Hua WU ; Jian-Dang ZHOU
Chinese Journal of Infection Control 2024;23(8):942-953
Objective To investigate the distribution and antimicrobial susceptibility of clinically isolated bacteria from intensive care units(ICUs)in hospitals of Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021.Methods According to China Antimicrobial Resistance Surveillance System,data of clinically isolated bacterial strains and antimicrobial susceptibility testing results of bacteria from ICUs reported by all member units of Hunan Province Antimicrobial Resistance Surveillance System were analyzed with WHONET 2022 software.Results From 2012 to 2021,the total number of bacteria isolated from ICUs of member units of the Hunan Province Antimi-crobial Resistance Surveillance System was 5 777-22 369,with Gram-negative bacteria accounting for 76.1%-78.0%annually.Staphylococcus aureus ranked first among isolated Gram-positive bacteria each year.The top 5 bacteria among Gram-negative bacteria were Acinetobacter baumannii,Klebsiella pneumoniae,Escherichia coli,Pseudo-monas aeruginosa,and Stenotrophomonas maltophilia.Detection rate of methicillin-resistant Staphylococcus aureus showed a downward trend year by year.No Staphylococcus spp.were found to be resistant to vancomycin,teico-planin and linezolid.Detection rates of vancomycin-resistant Enterococcus faecalis and vancomycin-resistant Entero-coccus faecium were 0.6-1.1%and 0.6%-2.2%,respectively.Resistance rates of Escherichia coli and Kleb-siella pneumoniae to imipenem were 3.1%-5.7%and 7.7%-20.9%,respectively.Resistance rates of Pseudo-monasaeruginosa and Acinetobacter baumannii to imipenem were 24.6%-40.1%and 76.1%-80.9%,respective-ly.Detection rates of carbapenem-resistant Pseudomonas aeruginosa declined year by year.Acinetobacter baumannii maintained high susceptibility to polymyxin B,with resistance rate<10%.Conclusion Antimicrobial resistance of bacteria from ICUs is serious.Carbapenem-resistant Enterobacteriales has an upward trend after 2019.It is nece-ssary to strengthen the surveillance of bacterial resistance and carry out multidisciplinary collaboration.
9.Antimicrobial resistance of Enterococcus spp.:surveillance report from Hunan Province Antimicrobial Resistance Surveillance System,2012-2021
Chen-Chao FU ; Li-Hua CHEN ; Chen LI ; Yan-Ming LI ; Jun LIU ; Xing-Wang NING ; Guo-Min SHI ; Jing-Min WU ; Huai-De YANG ; Hong-Xia YUAN ; Ming ZHENG ; An-Hua WU ; Xun HUANG ; Nan REN
Chinese Journal of Infection Control 2024;23(8):954-962
Objective To understand the antimicrobial resistance of clinically isolated Enterococcus spp.in Hunan Province.Methods Surveillance data of Enterococcus spp.resistance from member units of Hunan Provincial Anti-microbial Resistance Surveillance System from 2012 to 2021 were collected.Data were cleaned according to a unified method,and WHONET 5.6 software was adopted for statistical analysis.Results From 2012 to 2021,a total of 110 652 non-repetitive Enterococcus spp.strains were included in the analysis,mainly Enterococcus faecalis and Enterococcus faecium,accounting for 46.9%(n=37 774)and 45.9%(n=36 968),respectively,followed by En-terococcus avium(2.5%,n=1 982),Enterococcus gallinarum(1.8%,n=1 428),and Enterococcus casseliflavus(1.5%,n=1 185).The main specimen sources of Enterococcus spp.was urine(51.8%,n=57 350),followed by secretions(9.6%,n=10 660)and bile(8.5%,n=9 377).From 2012 to 2021,the resistance rates of Enteroco-ccus faecalis to ampicillin,teicoplanin,and vancomycin were 5.5%-12.0%,1.3%-2.0%,and 0.6%-1.4%,respectively.The resistance rates of Enterococcus faecium to ampicillin,teicoplanin,and vancomycin were 69.2%-85.0%,1.5%-2.8%,and 0.7%-2.5%,respectively.Except for linezolid and minocycline,the resistance rates of Enterococcus faecium to tested antimicrobial agents were all higher than those of Enterococcus faecalis.The re-sistance rates of Enterococcus faecalis and Enterococcus faecium to vancomycin decreased from 1.4%and 2.1%in 2012 to 0.6%and 0.7%in 2021,respectively,presenting a decreased trend.Conclusion Clinically isolated En-terococcus spp.maintain high antimicrobial susceptibility to vancomycin and teicoplanin.Resistance rates of Entero-coccus faecalis and Enterococcus faecium to vancomycin present decreased trends.
10.Antimicrobial resistance of bacteria isolated from bile:surveillance report from Hunan Province Antimicrobial Resistance Surveillance System,2012-2021
Chen LI ; Li-Hua CHEN ; Yan-Ming LI ; Jun LIU ; Xing-Wang NING ; Guo-Min SHI ; Jing-Min WU ; Huai-De YANG ; Hong-Xia YUAN ; Ming ZHENG ; Chen-Chao FU ; Nan REN ; Xun HUANG ; An-Hua WU
Chinese Journal of Infection Control 2024;23(8):963-974
Objective To analyze the distribution and changing trend of antimicrobial resistance of bacteria isolated from bile from Hunan Province Antimicrobial Resistance Surveillance System.Methods Data of pathogens isolated from bile from Hunan Province Antimicrobial Resistance Surveillance System from 2012 to 2021 were collected.The constituent of bacteria and antimicrobial susceptibility testing results were analyzed by WHONET 5.6 software.Changes in antimicrobial resistance was analyze by trend chi-square test.Results The major pathogenic bacteria isolated from bile were Gram-negative bacteria,accounting for 70.84%.The top three isolated Gram-negative pathogens were Escherichia coli(30.14%),Klebsiella pneumoniae(12.15%),and Pseudomonas aeruginosa(5.18%),and the top two Gram-positive bacteria were Enterococcus faecium(10.34%)and Enterococcus faecalis(9.52%).The resistance rates of Klebsiella pneumoniae and Escherichia coli to imipenem were highest in 2012-2013,being 15.7%and 14.9%,respectively,presenting an downward trend(P<0.05);resistance rates to piperacillin/tazobactam and cefoperazone/sulbactam were<24%,presenting an upward trend year by year(P<0.05);the sus-ceptibility rate to amikacin was>94%,to levofloxacin and ciprofloxacin was 15.5%-65.2%.The highest resis-tance rate of Pseudomonas aeruginosa to imipenem(32.0%)was higher than that of meropenem(22.9%),resis-tance rates to piperacillin/tazobactam and cefoperazone/sulbactam were<19%.The highest resistance rates of Acinetobacter baumannii to imipenem and meropenem were 59.4%and 62.6%,respectively,resistance rate to cefo-perazone/sulbactam was<48%,presenting an upward trend(P<0.05);the highest resistance rate to ciprofloxa-cin(60.8%)was higher than levofloxacin(48.7%);resistance rate to tigecycline was<8%.The resistance rates of Enterococcus faecium to penicillin and ampicillin were both higher than those of Enterococcus faecalis,presenting an upward trend(P<0.05).Resistance rate of Enterococcus faecium to vancomycin was lower than that of Entero-coccus faecalis.The resistance rates of Enterococcus faecium to vancomycin and linezolid were 0.5%-4.5%and 0.5%-3.4%,respectively;resistance rates of Enterococcus faecalis to vancomycin and linezolid were 0.2%-1.7%and 0.5%-3.5%,respectively(both P<0.05),all presenting a downward trend(all P<0.05).Conclusion Pathogenic bacteria isolated from bile are mainly related to the intestinal flora.The resistance rates of Enterococcus faecalis and Enterococcus faecium to vancomycin and linezolid as well as resistance rate of Enterobacterales to car-bapenem antibiotics all present a downward trend.

Result Analysis
Print
Save
E-mail