1.An experimental method for direct detection of lymphocyte γ-H2AX in mice peripheral blood and its application
Lei SHI ; Xing SHEN ; Ya DONG ; Qiaoyun ZHANG ; Hongling OU ; Xiujun SONG ; Yingying MA ; Xinru WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(1):18-23
Objective:To develop a method of employing flow cytometry to directly detect the γ-H2AX expression levels in peripheral blood lymphocytes of mice through fixation and lysis and to evaluate the feasibility of applying this method to research on the radiation-related biological effects and the efficacy evaluation of radioprotective drugs.Methods:A total of 41 male C57BL/6J mice were used. First, 21 mice were randomly divided into 7 groups according to different radiation doses (0, 1, 2, 4, 6, 8, and 10 Gy) with 3 mice in each group. Blood samples were collected from the tail vein of mice at 1, 4, 8, and 24 h after irradiation and immediately fixed with formaldehyde. Red blood cells (RBC) were lysed with Triton X-100, and γ-H2AX was labeled with specific antibodies. DRAQ5 dye was used to further exclude debris and anucleate cells. The mean fluorescence intensity of γ-H2AX in lymphocyte populations was directly analyzed by flow cytometry through forward and side scatter, and dose-effect curves after irradiation were established. Then, the other 20 mice were divided into radiation alone groups and radiation combined with WR-2721 administration groups at 4 and 6 Gy, respectively, with 5 mice in each group. Blood samples were collected from the tail vein of mice at 1, 4, 8, and 24 h after irradiation to detect the average fluorescence intensity of γ-H2AX in lymphocytes, which was used to evaluate the degree of DNA damage in mice and the therapeutic effect of WR-2721.Results:The expression of γ-H2AX in peripheral blood lymphocytes of mice significantly increased with the increase of radiation doses, and reached a peak at 1-2 h and then decreased. The dose-effect relationship was significant ( R2 = 0.9914). At 24 h after 4 and 6 Gy irradiation, compared with the radiation alone groups, the average fluorescence intensity of γ-H2AX in the radiation combined with WR-2721 administration groups was lower (144.8 ± 8.0 and 109.5 ± 9.7, vs. 178.0 ± 18.5 and 136.6 ± 5.4), with statistically significant difference ( t = 3.78, 5.48, P < 0.05). The average fluorescence intensity of γ-H2AX at 24 h after irradiation was consistent with the lowest values of the three blood cell lines at 7 or 14 d after irradiation. Conclusions:The application of flow cytometry with a fixation/dissolution protocol to directly detect the mean fluorescence intensity of γ-H2AX in peripheral blood lymphocytes of mice has significant application value in radiation biology effect research, radiation protection drug screening, and efficacy evaluation.
2.An experimental method for direct detection of lymphocyte γ-H2AX in mice peripheral blood and its application
Lei SHI ; Xing SHEN ; Ya DONG ; Qiaoyun ZHANG ; Hongling OU ; Xiujun SONG ; Yingying MA ; Xinru WANG
Chinese Journal of Radiological Medicine and Protection 2025;45(1):18-23
Objective:To develop a method of employing flow cytometry to directly detect the γ-H2AX expression levels in peripheral blood lymphocytes of mice through fixation and lysis and to evaluate the feasibility of applying this method to research on the radiation-related biological effects and the efficacy evaluation of radioprotective drugs.Methods:A total of 41 male C57BL/6J mice were used. First, 21 mice were randomly divided into 7 groups according to different radiation doses (0, 1, 2, 4, 6, 8, and 10 Gy) with 3 mice in each group. Blood samples were collected from the tail vein of mice at 1, 4, 8, and 24 h after irradiation and immediately fixed with formaldehyde. Red blood cells (RBC) were lysed with Triton X-100, and γ-H2AX was labeled with specific antibodies. DRAQ5 dye was used to further exclude debris and anucleate cells. The mean fluorescence intensity of γ-H2AX in lymphocyte populations was directly analyzed by flow cytometry through forward and side scatter, and dose-effect curves after irradiation were established. Then, the other 20 mice were divided into radiation alone groups and radiation combined with WR-2721 administration groups at 4 and 6 Gy, respectively, with 5 mice in each group. Blood samples were collected from the tail vein of mice at 1, 4, 8, and 24 h after irradiation to detect the average fluorescence intensity of γ-H2AX in lymphocytes, which was used to evaluate the degree of DNA damage in mice and the therapeutic effect of WR-2721.Results:The expression of γ-H2AX in peripheral blood lymphocytes of mice significantly increased with the increase of radiation doses, and reached a peak at 1-2 h and then decreased. The dose-effect relationship was significant ( R2 = 0.9914). At 24 h after 4 and 6 Gy irradiation, compared with the radiation alone groups, the average fluorescence intensity of γ-H2AX in the radiation combined with WR-2721 administration groups was lower (144.8 ± 8.0 and 109.5 ± 9.7, vs. 178.0 ± 18.5 and 136.6 ± 5.4), with statistically significant difference ( t = 3.78, 5.48, P < 0.05). The average fluorescence intensity of γ-H2AX at 24 h after irradiation was consistent with the lowest values of the three blood cell lines at 7 or 14 d after irradiation. Conclusions:The application of flow cytometry with a fixation/dissolution protocol to directly detect the mean fluorescence intensity of γ-H2AX in peripheral blood lymphocytes of mice has significant application value in radiation biology effect research, radiation protection drug screening, and efficacy evaluation.
3.Effects of long-term exposure to new types of light emitting diode sources on neurobehavior of rats
Fengrong LU ; Zhaoyang FENG ; Yihua SHI ; Guoliang LI ; Jiewei ZHENG ; Yuli ZENG ; Xiangrong SONG ; Xiao ZHANG ; Hongling LI ; Lihai ZENG ; Zhiwei XIE ; Jin WU ; Wenliang ZHOU ; Hailan WANG
China Occupational Medicine 2024;51(6):614-621
Objective To investigate the effects of long-term exposure to three new types of light emitting diode (LED) sources on the behavior, learning, and memory of rats. Methods A total of 160 specific pathogen-free SD rats were divided into eight groups as followed, trichromatic fluorescent lamps color temperature control group, violet-chip full-spectrum white LED group, blue-chip white LED group, and blue-chip full-spectrum white LED group based on the light sources types, with color temperature of 4 000 K and 6 500 K groups in each group using the 4×2 factorial design. There were 20 rats in each group, with half of the rats were males and half females. Rats were exposed to artificial lighting, and the illumination was set at 750 lx. The rats in each group were exposed to different lighting environments for 12 hours per day for 24 weeks. The open-field and step-down tests were conducted in rats after 24 weeks exposure, followed by sacrifice of rats and measurement of organ coefficients. Differences in body weight, organ coefficients, and neurobehavioral indexes of rats in different groups were compared. Results The spleen coefficient of female rats decreased in blue-chip white LED of 6 500 K color temperature group, and the liver coefficient of male rats decreased in the violet-chip full-spectrum white LED of 4 000 K color temperature, blue-chip full-spectrum white LED of 4 000 K color temperature, and blue-chip full-spectrum white LED of 6 500 K color temperature groups, compared with the same-sex rats in trichromatic fluorescent lamps with same-color temperature control group (all P<0.05). The result of different types of light sources compared in the open-field test showed that the index of total distance and movement speed of female rats in the blue-chip full-spectrum white LED group were lower than those in the other three groups, and the time cost to the central area was longer than that in the blue-chip white LED group and the violet-chip full-spectrum white LED group (all P<0.05). The total distance and movement speed of male rats in the blue-chip full-spectrum white LED group were longer or higher than those in the violet-chip full-spectrum white LED group (all P<0.05). Based on the comparison of color temperature, the time and total distance of male rats in 6 500 K color temperature group were lower than that in the 4 000 K color temperature group (both P<0.05). In the step-down test, both male and female rats in the blue-chip full-spectrum white LED group made more errors compared with other three groups with the same gender (all P<0.05). Conclusion Based on the experimental conditions of this study, the blue-chip full-spectrum white light LED affects behavior, learning and memory of the rats, and trichromatic fluorescent lamp has the lowest effect on neurobehavior. The color temperature also affects behavior of the rats, and high color temperature has higher risk.
4.Construction of the quality evaluation scale of specification of management for humanistic caring in outpatients and its reliability and validity testing
Lixia YUE ; Na CUI ; Xu CHE ; Heng ZHANG ; Hongxia WANG ; Shujie GUO ; Hongling SHI ; Ruiying YU ; Xia XIN ; Xiaohuan CHEN ; Li WANG ; Zhiwei ZHI ; Lei TAN ; Xican ZHENG
Chinese Medical Ethics 2024;37(11):1366-1377
Objective:To construct the quality evaluation scale of specification of management for humanistic caring in outpatients and test its reliability and validity.Methods:Referring to the group standards in Specification of Management for Humanistic Caring in Outpatients released by the China Association for Life Care,as well as relevant guidelines and literature,a pool of items for the quality evaluation scale of specification of management for humanistic caring in outpatients was formed.After expert consultation and expert argumentation,a quality evaluation scale of specification of management for humanistic caring in outpatients was constructed.From January to February 2024,243 hospital managers from 5 hospitals in Zhengzhou were selected as survey subjects to conduct item analysis,and reliability and validity testing on the scale.Results:Two rounds of expert inquiry and two rounds of expert argumentation were conducted,with questionnaire response rates of 92.00%and 100.00%,respectively,and expert authority coefficients of 0.952.In the second round of the expert inquiry scale,the mean importance score of the first-level indicators was 4.80 to 5.00,the full score ratio was 88.00%to 100.00%,the coefficient of variation was 0.04 to 0.17,and Kendall's coefficient of concordance was 0.857(P<0.001);the mean importance score of the second-level indicators was 4.60 to 5.00,the full score ratio was 80.00%to 100.00%,the coefficient of variation was 0.00 to 0.21,and Kendall's coefficient of concordance was 0.775(P<0.001);the mean importance score of the third-level indicators was 4.60 to 5.00,the full score ratio was 76.00%to 100.00%,the coefficient of variation was 0.00 to 0.21,and Kendall's coefficient of concordance was 0.830(P<0.001).Finally,a quality evaluation scale of specification of management for humanistic caring in outpatients was formed,including 5 first-level indicators,25 second-level indicators,and 58 third-level indicators.Exploratory factor analysis produced 5 common factors with a cumulative variance contribution rate of 74.628%.The Pearson correlation coefficients between the five-factor scores ranged from 0.648 to 0.798,and the correlation coefficients between the factor scores and the total score of the scale ranged from 0.784 to 0.938.The scale-level content validity index(S-CVI)of the scale was 0.945,the item-content validity index(I-CVI)was 0.725 to 1.000,the Cronbach's alpha coefficient of the total scale was 0.973,and the retest reliability coefficient was 0.934.Conclusion:The constructed quality evaluation scale of specification of management for humanistic caring in outpatients has good scientific validity and reliability,and can be used as an evaluation tool for specification of management for humanistic caring in outpatients.
5.Advances in research and application of ionizing radiation biomarkers
Hongling OU ; Wenchao AI ; Yan WANG ; Yingying MA ; Lei SHI ; Qiaoyun ZHANG ; Xiujun SONG ; Xinru WANG
Chinese Journal of Pharmacology and Toxicology 2024;38(1):70-78
Exposure to ionizing radiation intervenes in genomic stability and gene expression,resulting in the disruption of normal metabolic processes in cells and organs by causing complex biolog-ical responses.Altered genomic variations,gene expression and metabolite concentrations in blood or tissue samples reflect systemic radiation damage.With the application of new techniques and exten-sive study on the mechanisms for ionizing radiation damage,related indicators such as chromosomal variation,gene expression,lipid and metabolism are being recognized and promise to be the markers for early diagnosis and prognosis of radiation exposure.Therefore,this article reviews recent progress in and potential applications of biomarkers related to ionizing radiation injury.
6.Impact of different diagnostic criteria for assessing mild micro-hepatic encephalopathy in liver cirrhosis: an analysis based on a prospective, multicenter, real-world study
Xiaoyan LI ; Shanghao LIU ; Chuan LIU ; Hongmei ZU ; Xiaoqing GUO ; Huiling XIANG ; Yan HUANG ; Zhaolan YAN ; Yajing LI ; Jia SUN ; Ruixin SONG ; Junqing YAN ; Qing YE ; Fei LIU ; Lei HUANG ; Fanping MENG ; Xiaoning ZHANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Yiling LI ; Ningning WANG ; Huipeng CUI ; Yanmeng WANG ; Chuang LEI ; Qinghai WANG ; Hongling TIAN ; Zhangshu QU ; Min YUAN ; Ruichun SHI ; Xiaoting YANG ; Dan JIN ; Dan SU ; Yijun LIU ; Ying CHEN ; Yuxiang XIA ; Yongzhong LI ; Qiaohua YANG ; Huai LI ; Xuelan ZHAO ; Zemin TIAN ; Hongji YU ; Xiaojuan ZHANG ; Chenxi WU ; Zhijian WU ; Shengqiang LI ; Qian SHEN ; Xuemei LIU ; Jianping HU ; Manqun WU ; Tong DANG ; Jing WANG ; Xianmei MENG ; Haiying WANG ; Zhenyu JIANG ; Yayuan LIU ; Ying LIU ; Suxuan QU ; Hong TAO ; Dongmei YAN ; Jun LIU ; Wei FU ; Jie YU ; Fusheng WANG ; Xiaolong QI ; Junliang FU
Chinese Journal of Hepatology 2023;31(9):961-968
Objective:To compare the differences in the prevalence of mild micro-hepatic encephalopathy (MHE) among patients with cirrhosis by using the psychometric hepatic encephalopathy score (PHES) and the Stroop smartphone application (Encephal App) test.Methods:This prospective, multi-center, real-world study was initiated by the National Clinical Medical Research Center for Infectious Diseases and the Portal Hypertension Alliance and registered with International ClinicalTrials.gov (NCT05140837). 354 cases of cirrhosis were enrolled in 19 hospitals across the country. PHES (including digital connection tests A and B, digital symbol tests, trajectory drawing tests, and serial management tests) and the Stroop test were conducted in all of them. PHES was differentiated using standard diagnostic criteria established by the two studies in China and South Korea. The Stroop test was evaluated based on the criteria of the research and development team. The impact of different diagnostic standards or methods on the incidence of MHE in patients with cirrhosis was analyzed. Data between groups were differentiated using the t-test, Mann-Whitney U test, and χ2 test. A kappa test was used to compare the consistency between groups. Results:After PHES, the prevalence of MHE among 354 cases of cirrhosis was 78.53% and 15.25%, respectively, based on Chinese research standards and Korean research normal value standards. However, the prevalence of MHE was 56.78% based on the Stroop test, and the differences in pairwise comparisons among the three groups were statistically significant (kappa = -0.064, P < 0.001). Stratified analysis revealed that the MHE prevalence in three groups of patients with Child-Pugh classes A, B, and C was 74.14%, 83.33%, and 88.24%, respectively, according to the normal value standards of Chinese researchers, while the MHE prevalence rates in three groups of patients with Child-Pugh classes A, B, and C were 8.29%, 23.53%, and 38.24%, respectively, according to the normal value standards of Korean researchers. Furthermore, the prevalence rates of MHE in the three groups of patients with Child-Pugh grades A, B, and C were 52.68%, 58.82%, and 73.53%, respectively, according to the Stroop test standard. However, among the results of each diagnostic standard, the prevalence of MHE showed an increasing trend with an increasing Child-Pugh grade. Further comparison demonstrated that the scores obtained by the number connection test A and the number symbol test were consistent according to the normal value standards of the two studies in China and South Korea ( Z = -0.982, -1.702; P = 0.326, 0.089), while the other three sub-tests had significant differences ( P < 0.001). Conclusion:The prevalence rate of MHE in the cirrhotic population is high, but the prevalence of MHE obtained by using different diagnostic criteria or methods varies greatly. Therefore, in line with the current changes in demographics and disease spectrum, it is necessary to enroll a larger sample size of a healthy population as a control. Moreover, the establishment of more reliable diagnostic scoring criteria will serve as a basis for obtaining accurate MHE incidence and formulating diagnosis and treatment strategies in cirrhotic populations.
7.Diagnostic value of a combined serology-based model for minimal hepatic encephalopathy in patients with compensated cirrhosis
Shanghao LIU ; Hongmei ZU ; Yan HUANG ; Xiaoqing GUO ; Huiling XIANG ; Tong DANG ; Xiaoyan LI ; Zhaolan YAN ; Yajing LI ; Fei LIU ; Jia SUN ; Ruixin SONG ; Junqing YAN ; Qing YE ; Jing WANG ; Xianmei MENG ; Haiying WANG ; Zhenyu JIANG ; Lei HUANG ; Fanping MENG ; Guo ZHANG ; Wenjuan WANG ; Shaoqi YANG ; Shengjuan HU ; Jigang RUAN ; Chuang LEI ; Qinghai WANG ; Hongling TIAN ; Qi ZHENG ; Yiling LI ; Ningning WANG ; Huipeng CUI ; Yanmeng WANG ; Zhangshu QU ; Min YUAN ; Yijun LIU ; Ying CHEN ; Yuxiang XIA ; Yayuan LIU ; Ying LIU ; Suxuan QU ; Hong TAO ; Ruichun SHI ; Xiaoting YANG ; Dan JIN ; Dan SU ; Yongfeng YANG ; Wei YE ; Na LIU ; Rongyu TANG ; Quan ZHANG ; Qin LIU ; Gaoliang ZOU ; Ziyue LI ; Caiyan ZHAO ; Qian ZHAO ; Qingge ZHANG ; Huafang GAO ; Tao MENG ; Jie LI ; Weihua WU ; Jian WANG ; Chuanlong YANG ; Hui LYU ; Chuan LIU ; Fusheng WANG ; Junliang FU ; Xiaolong QI
Chinese Journal of Laboratory Medicine 2023;46(1):52-61
Objective:To investigate the diagnostic accuracy of serological indicators and evaluate the diagnostic value of a new established combined serological model on identifying the minimal hepatic encephalopathy (MHE) in patients with compensated cirrhosis.Methods:This prospective multicenter study enrolled 263 compensated cirrhotic patients from 23 hospitals in 15 provinces, autonomous regions and municipalities of China between October 2021 and August 2022. Clinical data and laboratory test results were collected, and the model for end-stage liver disease (MELD) score was calculated. Ammonia level was corrected to the upper limit of normal (AMM-ULN) by the baseline blood ammonia measurements/upper limit of the normal reference value. MHE was diagnosed by combined abnormal number connection test-A and abnormal digit symbol test as suggested by Guidelines on the management of hepatic encephalopathy in cirrhosis. The patients were randomly divided (7∶3) into training set ( n=185) and validation set ( n=78) based on caret package of R language. Logistic regression was used to establish a combined model of MHE diagnosis. The diagnostic performance was evaluated by the area under the curve (AUC) of receiver operating characteristic curve, Hosmer-Lemeshow test and calibration curve. The internal verification was carried out by the Bootstrap method ( n=200). AUC comparisons were achieved using the Delong test. Results:In the training set, prevalence of MHE was 37.8% (70/185). There were statistically significant differences in AMM-ULN, albumin, platelet, alkaline phosphatase, international normalized ratio, MELD score and education between non-MHE group and MHE group (all P<0.05). Multivariate Logistic regression analysis showed that AMM-ULN [odds ratio ( OR)=1.78, 95% confidence interval ( CI) 1.05-3.14, P=0.038] and MELD score ( OR=1.11, 95% CI 1.04-1.20, P=0.002) were independent risk factors for MHE, and the AUC for predicting MHE were 0.663, 0.625, respectively. Compared with the use of blood AMM-ULN and MELD score alone, the AUC of the combined model of AMM-ULN, MELD score and education exhibited better predictive performance in determining the presence of MHE was 0.755, the specificity and sensitivity was 85.2% and 55.7%, respectively. Hosmer-Lemeshow test and calibration curve showed that the model had good calibration ( P=0.733). The AUC for internal validation of the combined model for diagnosing MHE was 0.752. In the validation set, the AUC of the combined model for diagnosing MHE was 0.794, and Hosmer-Lemeshow test showed good calibration ( P=0.841). Conclusion:Use of the combined model including AMM-ULN, MELD score and education could improve the predictive efficiency of MHE among patients with compensated cirrhosis.
8.Value of Coronary Sinus During Computed Tomography Pulmonary Angiography for Predicting Pulmonary Hypertension in Patients with Acute Pulmonary Embolism
Chuang ZHANG ; Qian XIN ; Hongling XU ; Xiangyu WANG ; Zhiqiang YAN ; Shengtao SUN ; Xiangmin SHI ; Mei TIAN
Cardiology Discovery 2023;03(2):78-84
Objective::Computed tomography pulmonary angiography (CTPA) parameters are valuable for predicting pulmonary hypertension (PH) in patients with pulmonary embolism (PE). However, few studies have used the coronary sinus ostium area (CSOA), derived from CTPA, to detect PH. This study aimed to compare the prognostic values of the CSOA, coronary sinus ostium diameter (CSOD), and right ventricular (RV)/left ventricular (LV) ratio for PH.Methods::This study retrospectively analyzed 78 patients (mean age, (51.94 ± 12.33) years; 53.8% male) with acute PE confirmed by CTPA at the Sixth and Eighth Medical Centers of the People’s Liberation Army General Hospital between June 2018 and June 2020. Patients were categorized into 2 groups using a pulmonary artery systolic pressure (PASP) cut-off of 30 mmHg. CTPA parameters were compared between these groups.Results::Patients with PASP >30 mmHg ( n = 22) had a larger CSOA, CSOD, RV diameter, RV/LV ratio, and inferior vena cava diameter compared with patients with PASP ≤30 mmHg ( n = 56). The CSOA had an area under the receiver-operating characteristic curve (AUC, 0.84; 95% confidence interval (CI), 0.74-0.94; P < 0.001) similar to that of the RV/LV ratio (AUC, 0.85; 95%CI, 0.73-0.99; P < 0.001), while that of the CSOD was smaller (AUC, 0.66; 95%CI, 0.51-0.81; P < 0.05). Conclusion::Both CSOA and CSOD demonstrated a good ability to predict PH, while CSOA better predicted PASP >30 mmHg.
9.Value of Coronary Sinus During Computed Tomography Pulmonary Angiography for Predicting Pulmonary Hypertension in Patients with Acute Pulmonary Embolism
Chuang ZHANG ; Qian XIN ; Hongling XU ; Xiangyu WANG ; Zhiqiang YAN ; Shengtao SUN ; Xiangmin SHI ; Mei TIAN
Cardiology Discovery 2023;03(2):78-84
Objective::Computed tomography pulmonary angiography (CTPA) parameters are valuable for predicting pulmonary hypertension (PH) in patients with pulmonary embolism (PE). However, few studies have used the coronary sinus ostium area (CSOA), derived from CTPA, to detect PH. This study aimed to compare the prognostic values of the CSOA, coronary sinus ostium diameter (CSOD), and right ventricular (RV)/left ventricular (LV) ratio for PH.Methods::This study retrospectively analyzed 78 patients (mean age, (51.94 ± 12.33) years; 53.8% male) with acute PE confirmed by CTPA at the Sixth and Eighth Medical Centers of the People’s Liberation Army General Hospital between June 2018 and June 2020. Patients were categorized into 2 groups using a pulmonary artery systolic pressure (PASP) cut-off of 30 mmHg. CTPA parameters were compared between these groups.Results::Patients with PASP >30 mmHg ( n = 22) had a larger CSOA, CSOD, RV diameter, RV/LV ratio, and inferior vena cava diameter compared with patients with PASP ≤30 mmHg ( n = 56). The CSOA had an area under the receiver-operating characteristic curve (AUC, 0.84; 95% confidence interval (CI), 0.74-0.94; P < 0.001) similar to that of the RV/LV ratio (AUC, 0.85; 95%CI, 0.73-0.99; P < 0.001), while that of the CSOD was smaller (AUC, 0.66; 95%CI, 0.51-0.81; P < 0.05). Conclusion::Both CSOA and CSOD demonstrated a good ability to predict PH, while CSOA better predicted PASP >30 mmHg.
10.Effects of oxidative stress, PSMB5, TFEB, and lysosomes on sodium arsenite-induced liver injury in rats
Hongling WANG ; Mingyang SHI ; Dingnian BI ; Haiyan ZHI ; Qian HU ; Yong HU
Journal of Environmental and Occupational Medicine 2022;39(10):1134-1139
Background Liver damage presented in endemic arsenic poisoning is usually serious. Studies have shown that oxidative stress, proteasome beta 5 subunit (PSMB5), regulatory transcription factor EB (TFEB), and lysosomes are associated with liver injury, but their specific links to arsenic-induced liver injury remain unclear. Objective Using a sodium arsenite (NaAsO2)-induced rat liver injury model established earlier by the research group, the expressions of PSMB5, TFEB, and lysosomal associated membrane protein 1 (LAMP1) in liver tissues were detected. Methods Twenty-four SPF Wistar rats were randomly divided into control group, and low, medium, and high dose groups, with 6 rats in each group, half male and half female. The exposure concentrations were 0, 25, 50, and 100 mg·L−1 NaAsO2 solutions for 24 weeks. At the end of the experiment, liver was dissected after rats were anesthetized. The levels of alkaline phosphatase (ALP), alanine aminotransferase (ALT), total bile acid (TBA), and catalase (CAT) in liver tissues were detected by chemical colorimetry, and the levels of lipid peroxide (LPO), 4-hydroxynonenal (4-HNE), LAMP1, and cathepsin D (CTSD) in liver tissues were detected by enzyme-linked immunosorbent assay (ELISA); the transcriptional expression levels of PSMB5 and TFEB in liver tissues were detected by real-time fluorescence quantitative PCR (RT-qPCR), and the protein expressions of PSMB5, TFEB, and phosphorylated TFEB (p-TFEB) in liver tissues were detected by immunohistochemistry. Results The results of chemical colorimetry and ELISA showed that compared with the control group, the liver homogenate levels of ALP, TBA, and LAMP1 of each arsenic-exposed group, the ALT and LPO in the medium and high concentration groups, the 4-HNE and CTSD in the high concentration group were increased, while the CAT activity of each arsenic-exposed group was decreased (P<0.05). The results of real-time fluorescence quantitative PCR showed that the transcription levels of PSMB5 and TFEB in the liver tissues of each arsenic-exposed group were decreased compared with those of the control group (P<0.05). The results of immunohistochemistry showed that compared with the control group, the expression of PSMB5 of each arsenic-exposed group were decreased, the expression of TFEB in the medium and high concentration groups was decreased, while the expression of p-TFEB of each arsenic-exposed group was increased (P<0.05). The expression of TFEB protein gradually decreased in the nucleus, while the expression of p-TFEB protein gradually increased in the cytoplasm, but no expression of p-TFEB was found in the nucleus. The results of Pearson correlation analysis showed that PSMB5 in liver tissues was positively correlated with CAT (r=0.818, P<0.05), and negatively correlated with 4-HNE and p-TFEB (r=−0.582, r=−0.899; P<0.05); TFEB was negatively correlated with CTSD and LAMP1 (r=−0.457, r=−0.564; P<0.05); CTSD was positively correlated with ALT and ALP (r=0.529, r=0.485; P<0.05). Conclusion Long-term exposure to NaAsO2 can induce oxidative stress, inhibit the expression of PSMB5 and TFEB, promote the accumulation of p-TFEB in the cytoplasm, decrease the nuclear entry of active TFEB, damage the lysosome, and cause liver damage.

Result Analysis
Print
Save
E-mail