1.Comparison of sleep EEG power spectral density between depressive episode patients and schizophrenia patients with suicidal behavior
Jingwen LIU ; Yunfei ZHOU ; Jingchu HU ; Jiaoyan ZHOU ; Junwei YANG ; Jie LIANG ; Hong XU ; Yu CANG ; Shimeng MA
Sichuan Mental Health 2026;39(1):50-57
BackgroundPatients with depressive episode and schizophrenia have a high risk of suicide. The sleep electroencephalogram power spectral density characteristics of patients with depressive episode accompanied by suicidal behavior and those with schizophrenia may be different, but there is currently a lack of direct comparative studies on these two groups of patients. ObjectiveTo compare the sleep electroencephalogram power spectral density between depressive episode and schizophrenic patients with suicidal behavior, in order to provide references for exploring predictive indicators of suicidal behavior. MethodsFrom June 2018 to December 2020, 20 patients with depressive episode and 20 patients with schizophrenia who had committed suicide within the past month and were treated at the outpatient department of Shenzhen Kangning Hospital were selected. All of them met the diagnostic criteria for depressive episode or schizophrenia as defined in the International Classification of Diseases, tenth edition (ICD-10). Using a random sampling method, 20 volunteers with matching gender and age to the patient groups were selected from the Cuiping community in Shenzhen as the control group. The subjective sleep of the patients was evaluated using the Insomnia Severity Index (ISI), the Dysfunctional Belief and Attitude about Sleep (DBAS), the Disturbing Dreams and Nightmare Severity Index (DDNSI), and the Epworth Somnolence Scale (ESS). The objective sleep of the patients was assessed using polysomnography. The sleep electroencephalogram was filtered and the power spectral density of the brain wave was analyzed and processed for all the subjects. The subjective and objective sleep conditions of the two patient groups were compared, and the sleep electroencephalogram power spectral density of the patient groups and the control group were also compared. ResultsA comparison of subjective and objective sleep conditions between patients with depressive episode accompanied by suicidal behavior and patients with schizophrenia accompanied by suicidal behavior showed no statistically significant differences (P>0.05). Comparisons of sleep electroencephalogram power spectral density in the W stage (average power of α wave, total power of δ wave, average power of δ wave, average power of θ wave), N1 stage (average power of β wave, total power of α wave, total power of δ wave), N2 stage (total power of α wave, average power of α wave, total power of δ wave, average power of δ wave), N3 stage (average power of α wave, average power of δ wave), and R stage (total power of α wave, average power of α wave, total power of δ wave, average power of δ wave) between patients with depressive episode accompanied by suicidal behavior, patients with schizophrenia accompanied by suicidal behavior, and the control group showed statistically significant differences (P<0.05 or 0.01). The total power of δ wave in the W stage and the average power of β wave and δ wave in the N1 stage were higher in two patient groups were higher than those of the control group. The total power of α wave and the average power of α wave in the N2 stage were lower than those of the control group, while the average power of δ wave was higher than that of the control group. The average power of α wave in the N3 stage of both patient groups were lower than that of the control group, while the average power of δ wave was higher than that of the control group. The total power and average power of α wave in the R stage were lower than those of the control group, while the total power and average power of δ wave were higher than those of the control group. All the differences were statistically significant. Patients with depressive episode accompanied by suicidal behavior had higher average powers of α wave, δ wave, and θ wave in the W stage compared with the control group, while the total power of α wave in the N1 stage was lower in the former group. All these differences were statistically significant (P<0.05). ConclusionThe depressive episode patients accompanied by suicidal behavior have highly overlapping sleep electroencephalogram abnormal patterns with those of schizophrenia patients, mainly manifested as a general decrease in α wave power (N2, N3, R stage) and a general increase in δ wave power (W, N1, N2, N3, R stage) as well as β wave power in N1 stage. At the same time, patients with depressive episode accompanied by suicidal behavior also show specific changes, including an increase in the average power of α and θ waves during the wakefulness period (W stage), and a decrease in the total power of α wave in N1 stage. [Funded by Guangdong Province High-level Clinical Key Specialty (with supporting funds from Shenzhen City) (number, SZGSP013); Shenzhen Key Medical Discipline (number, SZXK041); Shenzhen Clinical Medicine Research Center Project (number, 20210617155253001)]
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
5.Combination of CT/MRI LI-RADS With Second-Line Contrast-Enhanced Ultrasound Using Sulfur Hexafluoride or Perfluorobutane for Diagnosing Hepatocellular Carcinoma in High-Risk Patients
Yu LI ; Sheng LI ; Qing LI ; Kai LI ; Jing HAN ; Siyue MAO ; Xiaohong XU ; Zhongzhen SU ; Yanling ZUO ; Shousong XIE ; Hong WEN ; Xuebin ZOU ; Jingxian SHEN ; Lingling LI ; Jianhua ZHOU
Korean Journal of Radiology 2025;26(4):346-359
Objective:
The CT/MRI Liver Imaging Reporting and Data System (LI-RADS) demonstrates high specificity with relatively limited sensitivity for diagnosing hepatocellular carcinoma (HCC) in high-risk patients. This study aimed to explore the possibility of improving sensitivity by combining CT/MRI LI-RADS v2018 with second-line contrast-enhanced ultrasound (CEUS) LI-RADS v2017 using sulfur hexafluoride (SHF) or perfluorobutane (PFB).
Materials and Methods:
This retrospective analysis of prospectively collected multicenter data included high-risk patients with treatment-naive hepatic observations. The reference standard was pathological confirmation or a composite reference standard (only for benign lesions). Each participant underwent concurrent CT/MRI, SHF-enhanced US, and PFB-enhanced US examinations. The diagnostic performances for HCC of CT/MRI LI-RADS alone and three combination strategies (combining CT/ MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or a modified algorithm incorporating the Kupffer-phase findings for PFB [modified PFB]) were evaluated. For the three combination strategies, apart from the CT/MRI LR-5 criteria, HCC was diagnosed if CT/MRI LR-3 or LR-4 observations met the LR-5 criteria using LI-RADS SHF, LI-RADS PFB, or modified PFB.
Results:
In total, 281 participants (237 males; mean age, 55 ± 11 years) with 306 observations (227 HCCs, 40 non-HCC malignancies, and 39 benign lesions) were included. Using LI-RADS SHF, LI-RADS PFB, and modified PFB, 20, 23, and 31 CT/MRI LR-3/4 observations, respectively, were reclassified as LR-5, and all were pathologically confirmed as HCCs. Compared to CT/MRI LI-RADS alone (74%, 95% confidence interval [CI]: 68%–79%), the three combination strategies combining CT/MRI LI-RADS with either LI-RADS SHF, LI-RADS PFB, or modified PFB increased sensitivity (83% [95% CI: 77%–87%], 84% [95% CI: 79%–89%], 88% [95% CI: 83%–92%], respectively; all P < 0.001), while maintaining the specificity at 92% (95% CI: 84%–97%).
Conclusion
The combination of CT/MRI LI-RADS with second-line CEUS using SHF or PFB improved the sensitivity of HCC diagnosis without compromising specificity.
6.Development of A High-performance Rectangular Ion Trap for Multi-reflection Time-of-Flight Mass Spectrometer
Xiao-Xia CHEN ; Yi REN ; Qi HUANG ; Da-Jun XIANG ; Chang-Wei LI ; Yi HONG ; Lei LI ; Zheng-Xu HUANG ; Mei LI ; Jing-Wei XU ; Zhen ZHOU
Chinese Journal of Analytical Chemistry 2025;53(1):38-46
As a new generation of time-of-flight mass spectrometry,multiple-reflection time-of-flight mass spectrometry(MR-TOF-MS)has been increasingly applied in the fields such as nuclear physics,chemistry,and biology due to its ultra-high resolution and rapid analysis capabilities.However,the analytical performance of MR-TOF-MS largely depends on the ion bunch state entering the mass analyzer.In this study,a rectangular ion trap(RIT)was developed,designed and processed using printed circuit board technology,as an ion accumulating and focusing device for MR-TOF mass analyzer.Compared to traditional ion traps composed of two sets of planar electrodes,this RIT had higher voltage utilization efficiency,resulting in more efficient ion collection and focusing.The ions were cooled to a sufficiently small bunch for precise mass measurement with MR-TOF-MS mass spectrometry in only 1 ms of cooling time in the RIT,then orthogonally ejected to the MR-TOF mass spectrometer for mass analysis.Experimental results indicated that the working cycle,ion flux,and ion focusing state of the RIT fully met the requirements of the MR-TOF mass analyzer.When coupled with the MR-TOF mass analyzer,the RIT enabled MR-TOF-MS to achieve a mass resolution of 1.5×105.
7.Colorimetric Sensor for Determination of Golgi Protein 73 Based on Hemin-Reduced Graphene Oxide-Manganese Dioxide Nanozyme
Xiao-Hong TAN ; Jia-Hao ZHOU ; Pei-Hong XU ; Hao LIN ; Gui-Yin LI
Chinese Journal of Analytical Chemistry 2025;53(9):1476-1485
Hepatocellular carcinoma(HCC)is one of common cancer that seriously endangers human health.Designing methods for early,rapid,and accurate diagnosis of HCC has become the key point.Golgi protein 73(GP73),a novel potential biomarker for HCC,is crucial for diagnosis and treatment of HCC.In this study,a colorimetric sensor with rapidity,smplicity and high specificity was established for detection of GP73 based on peroxidase-like activity of hemin-reduced graphene oxide-manganese dioxide(H-rGO-MnO2).The H-rGO-MnO2-GP73Apt1 signal probe was synthesized by carboxyl of H-rGO-MnO2 nanozyme and amination of GP73 aptamer(GP73Apt1)though amide reaction.In the presence of GP73,the sulfhydryl-modifed GP73 aptamer(GP73Apt2),as the capture probe,and the signal probe both specifically recognized GP73,forming a sandwich structure(GP73Apt2-GP73-H-rGO-MnO2-GP73Apt1).This structure could catalyze the oxidation of H2O2 to produce hydroxyl radical(·OH),thereby oxidizing the colorless phthalenediamine(OPD)into the yellow 2,3-diaminophenazine(DPA).The quantitative detection of GP73 was achieved by measuring the characteristic absorbance of DPA at 450 nm.In the GP73 concentration range of 10-150 ng/mL,there was a good linear relationship between the DPA absorbance at 450 nm(A450 nm)and the GP73 concentration under optimal conditions.The linear equation was A450 nm=0.00321CGP73+0.8988,with the correlation coefficient(R2)of 0.9960 and the detection limit(LOD)of 5.38 ng/mL.The colorimetric sensor was applied to detection of GP73 in human serum samples,with recoveries of 88.4%?98.8%.This sensor showed high specificity,sensitivity,and stability,and had potential for clinical detection of GP73,providing a new approach for the early diagnosis of HCC.
8.Screening of Illicit Oxyphenisatin Substances in Weight-Loss Dietary Supplements by High Performance Liquid Chromatography-in-Source-Fragmentation-Quadrupole Time-of-Flight Mass Spectrometry
Hong-Fei SHI ; Ke-Yu LIU ; Bo-Peng XU ; Cheng-Xin XU ; Xiu-Qi ZHOU ; Yi-Fei ZHOU ; Ming-Xin GUO
Chinese Journal of Analytical Chemistry 2025;53(9):1576-1585,后插1-后插9,封3
By summarizing the mass spectrometric fragmentation patterns of oxyphenisatin substances,an analytical method was established for screening of illegally added oxyphenisatin compounds in weight-loss health foods using high performance liquid chromatography-in-source-fragmentation-quadrupole time-of-flight mass spectrometry(HPLC-ISF-QTOF-MS),along with a quantitative method for 11 kinds of oxyphenisatin compounds.Based on the developed screening method,an oxyphenisatin derivative was discovered in the reference standards,which was tentatively identified as 4-(3-(4-hydroxyphenyl)-2-oxoindolin-3-yl)phenyl acetate and confirmed by MS/MS analysis.The results showed that all 11 kinds of oxyphenisatin compounds had correlation coefficients greater than 0.9971,with limits of detection(LODs)ranging from 0.12 to 0.68 μg/L and limits of quantification(LOQ)from 0.21 to 2.29 μg/L.The LODs for 11 kinds of characteristic ions ranged from 0.45 to 9.11 μg/kg.At spiking levels of 25,50 and 100 μg/kg,the recoveries ranged from 78.9%to 117.3%.The instrumental precision,intra-day method precision and inter-day method precision were 0.23%?1.70%,0.7%?2.4%,and 1.1%?3.3%,respectively.The developed targeted and non-targeted detection method demonstrated high sensitivity,strong stability,rapid analysis,and an expanded screening range for oxyphenisatin substances,and provided robust technical support for regulatory authorities in combating illegal adulteration.
9.PPAR δ-87T/C plays a critical role in the development of colorectal cancer.
Bo DONG ; Lie YANG ; Bin YANG ; Bin ZHOU ; Ben NIU ; Taiqi WANG ; Zhaowan XU ; Lin ZHU ; Guang HU ; Wenjian MENG ; Hong ZHANG ; Zongguang ZHOU ; Xiaofeng SUN
Chinese Medical Journal 2025;138(23):3209-3211
10.Processing technology of calcined Magnetitum based on concept of QbD and its XRD characteristic spectra.
De-Wen ZENG ; Jing-Wei ZHOU ; Tian-Xing HE ; Yu-Mei CHEN ; Huan-Huan XU ; Jian FENG ; Yue YANG ; Xin CHEN ; Jia-Liang ZOU ; Lin CHEN ; Hong-Ping CHEN ; Shi-Lin CHEN ; Yuan HU ; You-Ping LIU
China Journal of Chinese Materia Medica 2025;50(9):2391-2403
Guided by the concept of quality by design(QbD), this study optimizes the calcination and quenching process of calcined Magnetitum and establishes the XRD characteristic spectra of calcined Magnetitum, providing a scientific basis for the formulation of quality standards. Based on the processing methods and quality requirements of Magnetitum in the Chinese Pharmacopoeia, the critical process parameters(CPPs) identified were calcination temperature, calcination time, particle size, laying thickness, and the number of vinegar quenching cycles. The critical quality attributes(CQAs) included Fe mass fraction, Fe~(2+) dissolution, and surface color. The weight coefficients were determined by combining Analytic Hierarchy Process(AHP) and the criteria importance though intercrieria correlation(CRITIC) method, and the calcination process was optimized using orthogonal experimentation. Surface color was selected as a CQA, and based on the principle of color value, the surface color of calcined Magnetitum was objectively quantified. The vinegar quenching process was then optimized to determine the best processing conditions. X-ray diffraction(XRD) was used to establish the characteristic spectra of calcined Magnetitum, and methods such as similarity evaluation, cluster analysis, and orthogonal partial least squares-discriminant analysis(OPLS-DA) were used to evaluate the quality of the spectra. The optimized calcined Magnetitum preparation process was found to be calcination at 750 ℃ for 1 h, with a laying thickness of 4 cm, a particle size of 0.4-0.8 cm, and one vinegar quenching cycle(Magnetitum-vinegar ratio 10∶3), which was stable and feasible. The XRD characteristic spectra analysis method, featuring 9 common peaks as fingerprint information, was established. The average correlation coefficient ranged from 0.839 5-0.988 1, and the average angle cosine ranged from 0.914 4 to 0.995 6, indicating good similarity. Cluster analysis results showed that Magnetitum and calcined Magnetitum could be grouped together, with similar compositions. OPLS-DA discriminant analysis identified three key characteristic peaks, with Fe_2O_3 being the distinguishing component between the two. The final optimized processing method is stable and feasible, and the XRD characteristic spectra of calcined Magnetitum was initially established, providing a reference for subsequent quality control and the formulation of quality standards for calcined Magnetitum.
X-Ray Diffraction/methods*
;
Drugs, Chinese Herbal/chemistry*
;
Quality Control
;
Particle Size

Result Analysis
Print
Save
E-mail