1.Randomized Controlled Study of Baoshen Prescription in Treating Stage Ⅳ Diabetic Nephropathy in Patients with Syndromes of Qi-Yin Deficiency and Kidney Collateral Stasis and Obstruction
Yiting QIU ; Shuangshuang HONG ; Zhiqiu LIU ; Xinru SUN ; Yuefen WANG ; Mengchao LIU ; Wenjing ZHAO
Chinese Journal of Experimental Traditional Medical Formulae 2025;31(3):124-131
ObjectiveTo evaluate the clinical efficacy and safety of Baoshen prescription in the treatment of stage Ⅳ diabetic nephropathy (DN) in the patients with syndromes of Qi-Yin deficiency and kidney collateral stasis and obstruction, and to explore the mechanism of this prescription delaying the disease progression. MethodsA randomized, controlled, double-blind, multicenter clinical trial was conducted, in which 94 stage Ⅳ DN patients with syndromes of Qi-Yin deficiency and kidney collateral stasis and obstruction were randomly assigned into Baoshen prescription and control groups (47 cases). The treatment lasted for 12 weeks. The primary efficacy indicators were mainly renal function indexes, including urine albumin-to-creatinine ratio (UACR), 24-hour urine total protein (24 h-UTP), serum creatinine (SCr), and estimated glomerular filtration rate (eGFR). The secondary efficacy indicators were metabolic memory of hyperglycemia, podocyte epithelial-to-mesenchymal transdifferentiation-related indexes, and TCM syndrome score. ResultsAfter 12 weeks of treatment, the Baoshen prescription group showed lowered levels of advanced glycation end products (lgAGEs), connective tissue growth factor (CTGF), type Ⅳ collagen (Col-Ⅳ), receptor of AGEs (RAGE), urinary fibroblast-specific protein-1 (FSP-1), UACR, 24 h-UTP, and glycated hemoglobin (HbAlc) (P<0.05), and an upward trend of miR-21 mRNA. The control group showed elevated levels of SCr and UREA and lowered levels of urinary FSP-1, eGFR, and HbAlc (P<0.05). After treatment, the Baoshen prescription group had lower levels of lgAGEs, CTGF, urinary FSP-1, SCr, UACR, and 24 h-UTP and higher levels of Col-Ⅳ and eGFR than the control group (P<0.05). In addition, the Baoshen prescription group showed statistically significant differences in SCr, eGFR, UACR, and 24 h-UTP before and after treatment (P<0.05). ConclusionBaoshen prescription can effectively improve the renal function, reduce the urinary protein level, and alleviate clinical symptoms in stage Ⅳ DN patients with syndromes of Qi-Yin deficiency and kidney collateral stasis and obstruction. The mechanism may be related to the metabolic memory of hyperglycemia and epithelial-to-mesenchymal transdifferentiation of podocytes.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.A clinical study on the effectiveness of feedforward control mode on improving occupational burnout among operating room nurses
Ru GU ; Liyan ZHAO ; Qianru WANG ; Hong ZHANG ; Dan LEI ; Yang YAO ; Pan LIU ; Jinzhu SUN ; Na LI
Chinese Medical Ethics 2025;38(10):1373-1378
ObjectiveTo explore the effectiveness of feedforward control mode on improving occupational burnout among operating room nurses through theoretical research and clinical practice, with a view to promoting their physical and mental health and enhancing the quality of surgical nursing. MethodsA total of 440 operating room nurses from different regions, scales, and nursing experiences in Shaanxi Province from November 2023 to December 2023 were randomly divided into an experimental group and a control group, with 220 nurses in each group. While the control group received routine intervention measures, the experimental group introduced a feedforward control mode based on the control group, with “emotional exhaustion,” “depersonalization,”and“personal achievement” as observation indicators. ResultsThe incidence of occupational burnout in the experimental group was 11.4%, while that in the control group was 20.0%. The experimental group showed a significantly lower incidence than the control group (P=0.013). ConclusionThe feedforward control mode can significantly alleviate nurses’ sense of job burnout, promote the improvement of surgical nursing quality, as well as continuously improve the scientific rigor, advancement, and humanistic nature of nursing services, which is conducive to building a harmonious and efficient nursing team. The spirit of teamwork, reflected in mutual support, mutual trust, and joint efforts for surgical success and patient health, has become an important component of nurses’ professional ethics.
8.Effect of palmatine inhibiting migration,invasion and epithelial mesenchymal transformation in human oral cancer KB cells
Xue-Yun CHENG ; Guang-Yao HU ; Hong-Li LIU ; Chen-Guang LIU ; Yuan-Li DING ; Hui-Ning YANG ; Yi-An ZHAO ; Zhi-Guang SUN
The Chinese Journal of Clinical Pharmacology 2024;40(12):1749-1753
Objective To investigate the effects of palmatine on migration,invasion and epithelial mesenchymal transformation(EMT)in human oral cancer KB cells.Methods KB cells were divided into control group and palmatine-L,-M,-H groups,cultured with 0,4,8 and 16 μmol·L-1 palmatine.After incubation for 48 h,scratch assay was used to detect migration;Traswell assay was used to detect invasion;matrix metalloproteinase 2(MMP-2),MMP-9 and fibronectin(FN)contents were detected by enzyme-linked immunosorbent assay;the expression of Vimentin,N-cadherin and E-cadherin mRNA were detected by real-time quantitative polymerase chain reaction;the expression of Vimentin,N-cadherin,E-cadherin,Wnt3 and β-catenin protein were detected by Western blot.Results Cell mobility in control group and palmatine-L,-M,-H groups were(69.27±8.62)%,(52.94±4.49)%,(45.22±5.05)%and(37.63±4.88)%;the number of transmembrane cells were 197.33±20.26,125.33±12.01,97.00±9.17 and 62.67±7.51;the content of MMP-2 were(2.93±0.21),(1.49±0.13),(1.16±0.15)and(0.95±0.09)ng·mL-1;the content of MMP-9 were(3.51±0.36),(2.37±0.23),(2.06±0.35)and(1.72±0.16)ng·mL-1;the content of FN were(41.28±4.02),(24.03±3.17),(20.67±2.63)and(13.82±2.19)ng·mL-1;the above indexes in palmatine-L,-M,-H groups were compared with the control group,and the differences were statistically significant(P<0.05,P<0.01).The mRNA and protein expressions of Vimentin,N-cadherin and E-cadherin,and the expressions of Wnt3 and β-catenin protein in palmatine-L,-M,-H groups were statistically significant compared with those in control group(P<0.05,P<0.01).Conclusion Palmatine can inhibit the migration,invasion and EMT of human oral cancer KB cells,and its mechanism is related to the regulation of Wnt/β-catenin signaling pathway.
9.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.
10.Establishment of SHERLOCK-HBA Detection Method and Its Application in Blood Identification
Qian-Wei YAO ; Hong-Xia HE ; Sheng HU ; Yi-Xia ZHAO ; Yu LUO ; An-Quan JI ; Qi-Fan SUN
Progress in Biochemistry and Biophysics 2024;51(8):1971-1982
ObjectiveRapid and accurate identification of body fluid traces at crime scenes is crucial for case investigation. Leveraging the speed and sensitivity of nucleic acid detection technology based on SHERLOCK, our research focuses on developing a peripheral blood SHERLOCK-HBA detection system to detect mRNA in forensic practice. MethodsShort crRNA fragments targeting the blood-specific mRNA gene HBA were designed and screened, alongside RPA primers. Optimal RPA primers were selected based on specificity and amplification efficiency, leading to the establishment of the RPA system. The most efficient crRNA was chosen based on relative fluorescence units (RFU) generated by the Cas protein reaction, and the Cas protein reaction system was constructed to establish the SHERLOCK-HBA detection method. The RPA and Cas protein reaction systems in the SHERLOCK detection system were then individually optimized. A total of 79 samples of five body fluids were tested to evaluate the method’s ability to identify blood, with further verification through species-specific tests, sensitivity tests, mixed spots detection, aged samples, UV-irradiated samples, and actual casework samples. ResultsThe SHERLOCK reaction system for the peripheral blood-specific marker HBA was successfully established and optimized, enabling detection within 30 min. The method demonstrated a detection limit of 0.001 ng total RNA, better than FOB strip method and comparable to RT-PCR capillary electrophoresis. The system could detect target body fluids in mixed samples and identify blood in samples stored at room temperature for three years and exposed to UV radiation for 32 h. Detection of 11 casework samples showed performance comparable to RT-PCR capillary electrophoresis. ConclusionThis study presents a CRISPR/Cas-based SHERLOCK-HBA detection system capable of accurately, sensitively, and rapidly identifying blood samples. Introducing CRISPR/Cas technology to forensic body fluid identification represents a significant advancement in applying cutting-edge molecular biology techniques to forensic science.The method’s simplicity, shorter detection time, and independence from specialized equipment make it promising for rapid blood sample identification in forensic cases.

Result Analysis
Print
Save