1.Overexpression of Ptpn2 inhibits SiO2-mediated inflammatory response in alveolar type II epithelial cells
Mengfei FENG ; Yi WEI ; Xinru SUN ; Jingshuo GONG ; Xuemin GAO ; Hong XU ; Ying ZHU
Journal of Environmental and Occupational Medicine 2025;42(4):482-489
Background Protein tyrosine phosphatase non-receptor type II (PTPN2) is essential for the regulation of inflammation and immunity, but the specific mechanism of action of Ptpn2 in silicosis is unknown. Objective To investigate the regulatory role of overexpression of Ptpn2 in SiO2-mediated inflammatory response in alveolar type II epithelial cells based on transcriptome sequencing. Methods This study was an in vitro study. A negative control group (vector transferred) and an overexpression of Ptpn2 group of mouse lung epithelial cell line MLE-12 cells were firstly constructed. Transcriptome sequencing was performed to detect differentially expressed genes (DEGs), differentially expressed mRNAs, and differentially expressed ncRNAs in the two groups of MLE-12 cells, and then the DEGs were analyzed by the Gene Ontology (GO) and the Kyoto Encyclopedia of Genes and Genomes (KEGG). Constructed MLE-12 cells and A549 cells were stimulated using SiO2 suspension, and divided into a negative control group (vector transferred), an overexpression of Ptpn2 group, a negative control + SiO2 group, and an overexpression of Ptpn2 + SiO2 group, respectively. Protein expressions of tumor necrosis factor-α (TNF-α) and interleukin (IL)-17A, IL-2, IL-1β were detected by Western blot. Positive TNF-α expression was detected by immunofluorescence staining. Results The results of Western blot showed that the protein expression level of PTPN2 was up-regulated in the overexpressed Ptpn2 group compared with the negative control group (P < 0.05). The volcano plot and clustering heat map showed that there were
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Finite element analysis of three internal fixation modalities for treatment of Pauwels type Ⅲ femoral neck fractures under different loading conditions
Zhenggang LI ; Xuehong SHANG ; Zhang WU ; Hong LI ; Chaojun SUN ; Huadong CHEN ; Zhe SUN ; Yi YANG
Chinese Journal of Tissue Engineering Research 2025;29(3):455-463
BACKGROUND:There is still no consensus on the optimal internal fixation for the treatment of Pauwels Ⅲ femoral neck fracture,and most of the related finite element analyses have been performed using a single simplified loading condition,and the biomechanical properties of commonly used internal fixation devices need to be further investigated. OBJECTIVE:To analyze the biomechanical characteristics of Pauwels Ⅲ femoral neck fractures treated with cannulated compression screw,dynamic hip screw,and femoral neck system by finite element method under different loading conditions of single-leg standing loads and sideways fall loads. METHODS:The DICOM data of healthy adult femur were obtained by CT scanning,imported into Mimics 15.0 software to obtain the rough model of bone tissue.The data exported from Mimics were optimized by Geomagics software,and then three internal fixation models were built and assembled with the femur model according to the parameters of the clinical application of the cannulated compression screw,dynamic hip screw,and femoral neck system by using Pro/E software.Finally,the three internal fixation models were imported into Ansys software for loading and calculation to analyze the stress distribution and displacement of the femur and the internal fixation under different working conditions of single-leg standing loads and sideways fall loads,as well as the stress characteristics of the calcar femorale and Ward's triangle. RESULTS AND CONCLUSION:(1)Under the single-leg standing load and the sideways fall load,the proximal femoral stress of the three internal fixation models was mainly distributed above the fracture end of the femoral neck.The peak stress of the proximal femoral end,fracture end,Ward triangle,and calcar femorale of the three internal fixation models were the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(2)Under the single-leg standing load and the sideways fall load,the peak displacement of the proximal femur of the three internal fixation models was all located at the top of the femoral head,and the peak displacement was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(3)The peak displacement of the three internal fixation models was all located at the top of the internal fixation device under the single-leg standing and sideways fall loading conditions,and the peak displacement values were the smallest in the femoral neck system internal fixation model and the largest in the cannulated compression screw internal fixation model.(4)The internal fixation stress of the three internal fixation models was mainly distributed in the area near the fracture end of the internal fixation device under the single-leg standing and sideways fall loads,and the peak value of internal fixation stress was the smallest in the femoral neck system model and the largest in the cannulated compression screw model.(5)These results suggest that the mechanical stability of the femoral neck system is the best,but there may be a risk of stress shielding of the fracture end and calcar femorale.The stress of the internal fixation device of the femoral neck system is more dispersed,and the risk of internal fixation break is lower.
6.Design, synthesis and anti-Alzheimer's disease activity evaluation of cinnamyl triazole compounds
Wen-ju LEI ; Zhong-di CAI ; Lin-jie TAN ; Mi-min LIU ; Li ZENG ; Ting SUN ; Hong YI ; Rui LIU ; Zhuo-rong LI
Acta Pharmaceutica Sinica 2025;60(1):150-163
19 cinnamamide/ester-triazole compounds were designed, synthesized and evaluated for their anti-Alzheimer's disease (AD) activity. Among them, compound
7.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Study on equivalence of biological activity of insulin glargine by quantitative immunofluorescence assay and insulin bioassay
Yi-Min GAO ; Hong-Mei ZHANG ; Kai-Yong HE ; Deng-Ke YIN ; Bei SUN ; Lei-Ming XU
Chinese Pharmacological Bulletin 2024;40(11):2193-2199
Aim To establish a quantitative immunofluorescent bioactivity assay(ICW)for insulin glargine based on CHO-IN-SRB 1284 transgenic cells,and to study its equivalence with in-sulin bioassay of Ch.P.Methods The cells were diluted 25 times with 1.5 × 108 L-1 cell density plates and 1 500 μmol·L-1 insulin glargine,and then diluted with a 3-fold gradient se-ries.The cells were stimulated in microporous plates for 20 min.After fixation,permeation and antibody incubation.Quantitative immunofluorescence biological activity was detected by odyssey two-color infrared fluorescence imaging system.Results There was a good dose-effect relationship between the concentration of insulin glargine in ICW and its relative potency.The method had good specificity,and the relative accuracy,intermediate preci-sion and linearity met the requirements.The relative deviation of biological activity results of 7 batches of insulin glargine samples measured by the two methods was less than 10%.The results were analyzed by SPSS and SAS software,which showed that the methods were correlated and equivalent.Conclusions The quantitative immunofluorescence assay for the biological activity of insulin glargine can be established.The method has good spe-cificity,high accuracy and precision,and has correlation and e-quivalent with biotiter assay,which can be applied to in vitro ef-ficacy evaluation and quality control of insulin glargine.
10.Clinical efficacy of double-bundle and double-tunnel enhanced reconstruction in the treatment of anterior cruciate ligament injury
Bao LI ; Xin-Wei LIU ; Yang SUN ; Ning SUN ; Yu WANG ; Ying-Chao DUAN ; Xiang-Hong CUI ; Yi-Peng SUN ; Hong YUAN
China Journal of Orthopaedics and Traumatology 2024;37(7):649-654
Objective To explore the clinical efficacy of double beam double tunnel enhanced reconstruction technique in the treatment of knee anterior cruciate ligament(ACL)training injuries.Methods Twenty-nine cases of ACL injury of knee joint from January 2021 to December 2021 were retrospectively analyzed.All the cases were underwent ligament reconstruc-tion surgery.Cases were grouped by surgical technique:there were 14 patients in conventional reconstruction group,including 13 males and 1 female,aged from 22 to 31 years old with an average of(27.07±7.28)years old,autogenous hamstring tendon was used for ligament reconstruction.There were 15 patients in the enhanced reconstruction group,including 13 males and 2 females,aged from 25 to 34 years old with an average of(29.06±4.23)years old,double tunnel ligament reconstruction,the autogenous hamstring muscle was used as the anteromedial bundle,and the posterolateral bundle was replaced by a high-strength line.The difference between knee tibial anterior distance,Lysholm score,International Knee Literature Committee(IKDC)subjective score,Tegner motor level score and visual analog scale(VAS)at 6th and 12th months after the surgery,limb symmetry index(LSI)were recorded at the last follow-up and surgery-related adverse effects during follow-up.Results All patients were followed up,ranged from 13 to 15 months with an average of(13.7±0.8)months.There were no serious adverse reactions related to surgery during the period.There was no statistical difference between the preoperative general data and the observation index of the two groups(P>0.05).The difference in tibial anterior distance at 6 and 12 months in the enhanced re-construction group(1.45±0.62)mm and(1.74±0.78)mm which were lower those that in the conventional reconstruction group(2.42±0.60)mm and(2.51±0.63)mm(P<0.05).There was no significant difference in postoperative Lysholm score,Tegner motor level score,IKDC score,VAS,and limb symmetry index at the last follow-up(P>0.05).Conclusion The enhanced recon-struction technique can more effectively maintain the stability of the knee joint and has no significant effect on the postoperative knee joint function compared with the traditional ligament reconstruction technique.The short-term curative effect is satisfac-tory,and it is suitable for the group with high sports demand.

Result Analysis
Print
Save
E-mail