1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Singapore consensus statements on the management of obstructive sleep apnoea.
Leong Chai LEOW ; Chuen Peng LEE ; Sridhar VENKATESWARAN ; Michael Teik Chung LIM ; Oon Hoe TEOH ; Ruth CHANG ; Yam Cheng CHEE ; Khai Beng CHONG ; Ai Ping CHUA ; Joshua GOOLEY ; Hong Juan HAN ; Nur Izzianie KAMARUDDIN ; See Meng KHOO ; Lynn Huiting KOH ; Shaun Ray Han LOH ; Kok Weng LYE ; Mark IGNATIUS ; Yingjuan MOK ; Jing Hao NG ; Thun How ONG ; Chu Qin PHUA ; Rui Ya SOH ; Pei Rong SONG ; Adeline TAN ; Alvin TAN ; Terry TAN ; Jenny TANG ; David TAY ; Jade TAY ; Song Tar TOH ; Serene WONG ; Chiang Yin WONG ; Mimi YOW
Annals of the Academy of Medicine, Singapore 2025;54(10):627-643
INTRODUCTION:
Obstructive sleep apnoea (OSA) is common in Singapore, with moderate to severe OSA affecting around 30% of residents. These consensus statements aim to provide scientifically grounded recommendations for the management of OSA, standar-dise the management of OSA in Singapore and promote multidisciplinary collaboration.
METHOD:
An expert panel, which was convened in 2024, identified several areas of OSA management that require guidance. The expert panel reviewed the current literature and developed consensus statements, which were later independently voted on using a 3-point Likert scale (agree, neutral or disagree). Consensus (total ratings of agree and neutral) was set a priori at ≥80% agreement. Any statement not reaching consensus was excluded.
RESULTS:
The final consensus included 49 statements that provide guidance on the screening, diagnosis and management of adults with OSA. Additionally, 23 statements on the screening, diagnosis and management of paediatric OSA achieved consensus. These 72 consensus statements considered not only the latest clinical evidence but also the benefits and harms, resource implications, feasibility, acceptability and equity impact of the recommendations.
CONCLUSION
The statements presented in this paper aim to guide clinicians based on the most updated evidence and collective expert opinion from sleep specialists in Singapore. These recommendations should augment clinical judgement rather than replace it. Management decisions should be individualised, taking into account the patient's clinical characteristics, as well as patient and caregiver concerns and preferences.
Humans
;
Sleep Apnea, Obstructive/diagnosis*
;
Singapore
;
Consensus
;
Adult
7.Mechanisms and treatment of inflammation-cancer transformation in colon from perspective of cold and heat in complexity in integrative medicine.
Ning WANG ; Han-Zhou LI ; Tian-Ze PAN ; Wei-Bo WEN ; Ya-Lin LI ; Qian-Qian WAN ; Yu-Tong JIN ; Yu-Hong BIAN ; Huan-Tian CUI
China Journal of Chinese Materia Medica 2025;50(10):2605-2618
Colorectal cancer(CRC) is one of the most common malignant tumors worldwide, primarily originating from recurrent inflammatory bowel disease(IBD). Therefore, blocking the inflammation-cancer transformation in the colon has become a focus in the early prevention and treatment of CRC. The inflammation-cancer transformation in the colon involves multiple types of cells and complex pathological processes, including inflammatory responses and tumorigenesis. In this complex pathological process, immune cells(including non-specific and specific immune cells) and non-immune cells(such as tumor cells and fibroblasts) interact with each other, collectively promoting the progression of the disease. In traditional Chinese medicine(TCM), inflammation-cancer transformation in the colon belongs to the categories of dysentery and diarrhea, with the main pathogenesis being cold and heat in complexity. This paper first elaborates on the complex molecular mechanisms involved in the inflammation-cancer transformation process in the colon from the perspectives of inflammation, cancer, and their mutual influences. Subsequently, by comparing the pathogenic characteristics and clinical manifestations between inflammation-cancer transformation and the TCM pathogenesis of cold and heat in complexity, this paper explores the intrinsic connections between the two. Furthermore, based on the correlation between inflammation-cancer transformation in the colon and the TCM pathogenesis, this paper delves into the importance of the interaction between inflammation and cancer. Finally, it summarizes and discusses the clinical and basic research progress in the TCM intervention in the inflammation-cancer transformation process, providing a theoretical basis and treatment strategy for the treatment of CRC with integrated traditional Chinese and Western medicine.
Humans
;
Colon/pathology*
;
Integrative Medicine
;
Animals
;
Cold Temperature
;
Cell Transformation, Neoplastic/drug effects*
;
Medicine, Chinese Traditional
;
Hot Temperature
;
Inflammation
;
Drugs, Chinese Herbal/therapeutic use*
;
Colonic Neoplasms/drug therapy*
8.The Relationship between Ig Class Switch Recombination and MMR Protein, Microsatellite Phenotype in Extranodal Marginal Zone Lymphoma of Mucosa-associated Lymphoid Tissue.
Hong-Xia WANG ; Jun CHEN ; Jing LI ; Guo-Feng LU ; Xiu-Hua HAN ; Rong YANG ; Ya-Jun JIANG
Journal of Experimental Hematology 2025;33(4):1036-1041
OBJECTIVE:
To investigate the relationship between Ig class switch recombination (CSR) and mismatch repair (MMR) protein, microsatellite phenotype in extranodal marginal zone lymphoma of mucosa-associated lymphoid tissue (MALT lymphoma).
METHODS:
Forty cases of MALT lymphoma archived in the Department of Pathology, Jiading District Central Hospital, Shanghai University of Medicine & Health Sciences were selected as the observation group, and twenty cases of benign lymphoid tissue hyperplasia were as the control group. The expressions of IgG, IgM, IgD, and IgA in both groups were detected by immunohistochemical double staining, and MMR proteins including MLH1, MSH2, MSH6, and PMS2 in both groups were detected by immunohistochemistry. Multiplex fluorescence PCR capillary electrophoresis was used to detect microsatellite phenotype in tumor and adjacent tissues of the experimental group.
RESULTS:
In the observation group, the proportions of single Ig heavy chain expression (modeⅠ), negative expression (modeⅡ), and multiple expression (mode Ⅲ) were 65% (26/40), 27.5% (11/40), and 7.5% (3/40), respectively, while in the control group were 0 (0/20), 5% (1/20), and 95% (19/20). The proportion of Ig heavy chain expression mode Ⅰ+Ⅱ in the observation group was 92.5%, which was significantly higher than 5% in the control group (P < 0.01). In the observation group, partial deletion of MMR protein was observed in 3 cases (7.5%), including 2 cases of MSH6 deletion and 1 case of both MSH6 and PMS2 deletion. In the control group, there was 1 case (5%) with PMS2 deletion. There was no significant difference in the deletion rate of MMR protein between the two groups ( P >0.05). A total of 5 cases of microsatellite instability (MSI) were detected in the observation group, including 1 case of low-frequency MSI (MSI-L), 4 cases of high-frequency MSI (MSI-H), and 2 cases of MSI-H with MSH6 deletion. When the loss expression of MSI-H or MMR protein was counted as a positive result, the MSI-H rate detected by PCR capillary electrophoresis was 10% (4/40), which was slightly higher than the MMR protein deletion rate detected by immunohistochemistry (7.5%, 3/40), but there was no statistically significant difference between the two groups (P >0.05). The MMR protein deletion rates among the Ig heavy chain protein expression mode Ⅰ, mode Ⅱ, and mode Ⅲ groups were 0 (0/26), 18.2% (2/11), and 33.3% (1/3), respectively. There was a statistically significant difference in the constituent ratios among the three groups (P < 0.05). The MMR protein deletion rates among the MSS, MSI-L, and MSI-H groups were 2.9% (1/35), 0 (0/1), and 50% (2/4), respectively. There was a statistically significant difference in the constituent ratios among the three groups (P < 0.05). MMR protein deficiency was positively correlated with Ig heavy chain expression pattern and MSI ( r =0.41, P < 0.05; r =0.48, P < 0.05), but Ig heavy chain expression pattern was not correlated with MSI ( r =0.02, P >0.05).
CONCLUSION
Ig heavy chain CSR detection is helpful for the differential diagnosis of MALT lymphoma. Low frequency MMR protein deletion and MSI-H phenotype exist in MALT lymphoma, which may be of certain value for the study of its occurrence, development and clinical treatment.
Humans
;
Lymphoma, B-Cell, Marginal Zone/genetics*
;
DNA Mismatch Repair
;
Immunoglobulin Class Switching
;
DNA-Binding Proteins/metabolism*
;
MutS Homolog 2 Protein
;
Microsatellite Repeats
;
Phenotype
;
MutL Protein Homolog 1
;
Mismatch Repair Endonuclease PMS2
;
Male
9.Histaminergic Innervation of the Ventral Anterior Thalamic Nucleus Alleviates Motor Deficits in a 6-OHDA-Induced Rat Model of Parkinson's Disease.
Han-Ting XU ; Xiao-Ya XI ; Shuang ZHOU ; Yun-Yong XIE ; Zhi-San CUI ; Bei-Bei ZHANG ; Shu-Tao XIE ; Hong-Zhao LI ; Qi-Peng ZHANG ; Yang PAN ; Xiao-Yang ZHANG ; Jing-Ning ZHU
Neuroscience Bulletin 2025;41(4):551-568
The ventral anterior (VA) nucleus of the thalamus is a major target of the basal ganglia and is closely associated with the pathogenesis of Parkinson's disease (PD). Notably, the VA receives direct innervation from the hypothalamic histaminergic system. However, its role in PD remains unknown. Here, we assessed the contribution of histamine to VA neuronal activity and PD motor deficits. Functional magnetic resonance imaging showed reduced VA activity in PD patients. Optogenetic activation of VA neurons or histaminergic afferents significantly alleviated motor deficits in 6-OHDA-induced PD rats. Furthermore, histamine excited VA neurons via H1 and H2 receptors and their coupled hyperpolarization-activated cyclic nucleotide-gated channels, inward-rectifier K+ channels, or Ca2+-activated K+ channels. These results demonstrate that histaminergic afferents actively compensate for Parkinsonian motor deficits by biasing VA activity. These findings suggest that targeting VA histamine receptors and downstream ion channels may be a potential therapeutic strategy for PD motor dysfunction.
Animals
;
Histamine/metabolism*
;
Male
;
Oxidopamine/toxicity*
;
Rats
;
Ventral Thalamic Nuclei/physiopathology*
;
Rats, Sprague-Dawley
;
Disease Models, Animal
;
Parkinson Disease/metabolism*
;
Neurons/physiology*
;
Humans
;
Optogenetics
10.Analysis of Tongue and Face Image Features of Anemic Women and Construction of Risk-Screening Model.
Hong Yuan FU ; Yi CHUN ; Ya Han ZHANG ; Yu WANG ; Yu Lin SHI ; Tao JIANG ; Xiao Juan HU ; Li Ping TU ; Yong Zhi LI ; Jia Tuo XU
Biomedical and Environmental Sciences 2025;38(8):935-951
OBJECTIVE:
To identify the key features of facial and tongue images associated with anemia in female populations, establish anemia risk-screening models, and evaluate their performance.
METHODS:
A total of 533 female participants (anemic and healthy) were recruited from Shuguang Hospital. Facial and tongue images were collected using the TFDA-1 tongue and face diagnosis instrument. Color and texture features from various parts of facial and tongue images were extracted using Face Diagnosis Analysis System (FDAS) and Tongue Diagnosis Analysis System version 2.0 (TDAS v2.0). Least Absolute Shrinkage and Selection Operator (LASSO) regression was used for feature selection. Ten machine learning models and one deep learning model (ResNet50V2 + Conv1D) were developed and evaluated.
RESULTS:
Anemic women showed lower a-values, higher L- and b-values across all age groups. Texture features analysis showed that women aged 30-39 with anemia had higher angular second moment (ASM)and lower entropy (ENT) values in facial images, while those aged 40-49 had lower contrast (CON), ENT, and MEAN values in tongue images but higher ASM. Anemic women exhibited age-related trends similar to healthy women, with decreasing L-values and increasing a-, b-, and ASM-values. LASSO identified 19 key features from 62. Among classifiers, the Artificial Neural Network (ANN) model achieved the best performance [area under the curve (AUC): 0.849, accuracy: 0.781]. The ResNet50V2 model achieved comparable results [AUC: 0.846, accuracy: 0.818].
CONCLUSION
Differences in facial and tongue images suggest that color and texture features can serve as potential TCM phenotype and auxiliary diagnostic indicators for female anemia.
Humans
;
Female
;
Tongue/diagnostic imaging*
;
Adult
;
Anemia/diagnosis*
;
Middle Aged
;
Face/diagnostic imaging*
;
Young Adult
;
Machine Learning

Result Analysis
Print
Save
E-mail