1.Evaluation of the anticoagulant effect of nafamostat mesylate in continuous veno-venous hemofiltration with different dilution methods for uremic patients
Li SHEN ; Yao ZHANG ; Jun WANG ; Hong ZHU ; Yong QIN ; Yuewu TANG ; Ni DU
China Pharmacy 2026;37(3):350-355
OBJECTIVE To evaluate the anticoagulant efficacy and safety of nafamostat mesylate (NM) in the treatment of uremic patients at high risk of bleeding undergoing continuous veno-venous hemofiltration (CVVH) with different methods (pre- dilution and post-dilution). METHODS A total of 130 uremic patients at high risk of bleeding who underwent CVVH treatment in the nephrology department of Chongqing University Three Gorges Hospital from July 2023 to September 2024 were selected. They were divided into pre-dilution group and post-dilution group according to the random number table method, with 65 cases in each group. Both groups of patients received CVVH treatment under NM anticoagulation. The pre-dilution group adopted the pre-dilution replacement method, while the post-dilution group adopted the post-dilution replacement method. The coagulation, pressure, and usage duration of the filter and dialysis circuit venous reservoirs were compared between the two groups. The changes in prothrombin time (PT), prothrombin time-international normalized ratio (PT-INR), activated partial thromboplastin time (APTT), and fibrinogen (FIB) in the peripheral venous blood before the heparin pump and after the filter at 1, 4 and 7 h of CVVH treatment, as well as 20 min after the end of treatment, were compared between the two groups. The single-compartment urea clearance rate (spKt/V), β2-microglobulin (β2-MG) clearance rate and the incidence of adverse reactions were duni2007@foxmail.com compared between the two groups. RESULTS Both the pre-dilution and post-dilution groups had 60 patients who completed the study. The incidence of grade Ⅱ-Ⅲ coagulation of the filter and venous reservoirs, as well as the number of patients with transmembrane and venous pressure alarm intervention in the post- dilution group were significantly higher or more than those in the pre-dilution group (P<0.05), while usage time of the filter and the pipeline in the post-dilution group was significantly shorter than that in the pre-dilution group (P<0.05). The APTT values before the heparin pump as well as PT and APTT values after the filter at 1 h, 4 h, and 7 h of CVVH treatment in the post-dilution group were significantly higher than those in the pre-dilution group (P<0.001). There were no significant differences in PT, PT- INR, APTT and FIB between the two groups of patients 20 min after the end of treatment (P>0.05). The spKt/v and β2-MG clearance rates in the post-dilution group were significantly higher than those in the pre-dilution group (P<0.001). There was no significant difference in the incidence of adverse reactions between the two groups (P>0.05). CONCLUSIONS When NM is used as an anticoagulant in the CVVH treatment of uremic patients at high risk of bleeding, compared with the pre-dilution treatment method, the post-dilution treatment method has a higher incidence of filter and dialysis tubing venous reservoir, a shorter usage time of the filter and pipeline, and a greater impact on extracorporeal coagulation, but has a higher solute clearance rate. Clinically, different dilution methods can be selected according to the different treatment needs of patients.
2.Development and validation of assessment and diagnostic tools for apraxia of speech of Chinese Putonghua
Tianhao NI ; Siyu BI ; Yuan DAI ; Hong QIAN ; Yongli WANG ; Qin WAN ; Zhaoming HUANG
Chinese Journal of Rehabilitation Theory and Practice 2026;32(5):550-560
ObjectiveTo develop an assessment tool for apraxia of speech (AOS) of Chinese Putonghua speakers and test its reliability and validity. MethodsThe Chinese Apraxia of Speech Assessment and Diagnostic Tool (CAADT) was developed based on the Apraxia of Speech Rating Scale 3.5, combined with the linguistic characteristics of Chinese and clinical experience. The tool consistsed of eleven items across three sections: articulation, prosody and alternating motion rates. Six experts evaluated the content validity. From November, 2024 to May, 2025, 51 patients with post-stroke AOS (experimental group) and ten patients with post-stroke aphasia without AOS (control group) were recruited from Anhui Wannan Rehabilitation Hospital (the Fifth People's Hospital of Wuhu), and tested with CAADT. Reliability was assessed using Cronbach's α coefficient, Kendall's coefficient of concordance W and Pearson correlation coefficient. Validity was evaluated using the content validity index (CVI) and Spearman correlation coefficient. Discriminative effect was analyzed using the receiver operating characteristic (ROC) curve. ResultsThe Cronbach's α coefficients for the articulation and prosody sections and the total scale were all > 0.9, while it was 0.454 for the alternating motion rates. Inter-rater reliability was good (W ≥ 0.598, P < 0.001). Test-retest reliability showed high positive correlations for the three sections and the total score between the two assessments (r ≥ 0.84, P < 0.001). The scale-level CVI was 0.95, and the item-level CVI ≥ 0.83. The Spearman correlation coefficients among the sections ranged from 0.30 to 0.70. ROC analysis revealed an area under the curve of 0.953, with a cut-off value of 11, yielding a sensitivity of 0.92 and a specificity of 0.90. ConclusionCAADT demonstrates good reliability, validity and discriminative effect, which can be used for clinical assessment and auxiliary diagnosis of Chinese Putonghua speaking patients with post-stroke AOS.
3.Isolation, Identification and Biological Characteristics Analysis of Citrobacter freundii from Cynomolgus Monkey (Macaca fascicularis)
Heling LI ; Ziyao QIAN ; Gangmin QIN ; Debing JIANG ; Yanqiong ZHANG ; Wenzheng JIN ; Hong WANG
Laboratory Animal and Comparative Medicine 2026;46(3):367-377
ObjectiveIdentification and analysis, animal regression test, and drug susceptibility study were conducted on a pathogenic strain causing diarrhea in cynomolgus monkeys, aiming to provide a practical basis for the clinical treatment of Citrobacter freundii. MethodsFresh fecal samples were collected from nine diarrheal cynomolgus monkeys and streaked on Salmonella-Shigella (SS) medium, LB medium, and Columbia blood agar medium, and incubated at 37 ℃ for 24 h. Subsequently, the isolated strain was identified by colony morphology observation, Gram staining, biochemical tests and 16S rRNA gene sequencing, and PCR was used to detect its major virulence genes. After propagation, the isolate was intragastrically administered to healthy cynomolgus monkeys and C57BL/6 mice for animal regression tests to evaluate its pathogenicity. Finally, the disk-diffusion method was used to detect the antimicrobial susceptibility of the isolate. ResultsA single bacterial strain, designated MF071743, was isolated from 9 fecal samples collected from diarrheal cynomolgus monkeys. The isolate formed pink, smooth, round colonies on SS medium; translucent, smooth, moist, shiny colonies with neat edges on LB medium; and smooth, moist, off-white colonies on Columbia blood agar medium. Gram staining revealed that the isolate was a Gram-negative, spore-free short bacillus. Biochemical tests showed that the isolate was positive for motility test, mannitol test, hydrogen sulfide test, methyl red test, citrate utilization test, gas production from glucose test, raffinose test, sorbitol test, and D-xylose test, but negative for phenylalanine test, gluconate test, indole test, Voges Proskauer (VP) test, urease test, lysine test, ornithine test, and adonitol test. The results of 16S rRNA gene sequencing showed that the gene sequence similarity between strain MF071743 and Citrobacter freundii was 99.0%. PCR results showed that this strain carries genes encoding the urease accessory proteins UreD, UreE, and UreF. Animal intragastric administration assays demonstrated that the strain caused loose stools in cynomolgus monkeys, and all C57BL/6 mice died within 72 h. Drug susceptibility test results indicated that the isolate was sensitive to 16 antibiotics, including ceftriaxone, amikacin, gentamicin, ceftazidime, and levofloxacin, while it exhibited resistance to 5 antibiotics, including ampicillin, cefazolin, vancomycin, erythromycin, and cephalexin. ConclusionA strain of Citrobacter freundii with certain drug resistance was isolated from the feces of diarrheal cynomolgus monkeys. The results of this study provide a reference for the diagnosis and treatment of gastrointestinal diseases in captive laboratory monkeys.
4.Research on The Construction and Application of Multiple Fluorescence Amplification System for Three Kinds of Stains
Yi-Fan BAI ; He-Miao ZHAO ; Jing CHEN ; Hong-Di LIU ; Rui-Qin YANG ; Chong WANG
Progress in Biochemistry and Biophysics 2025;52(4):982-994
ObjectiveA multiplex amplification system was constructed based on the capillary electrophoresis platform for simultaneous detection of saliva, semen, and vaginal secretions using tissue-specific RNA markers. The aim of this study is to identify the tissue origin of suspicious body fluid stains found at crime scenes and determine whether the body fluid stains at the crime scene are one or several types among saliva, semen, and vaginal secretions. MethodsThirty saliva samples, forty semen samples, and forty vaginal secretion samples (half from 2015 and half from 2024) were collected from healthy adult volunteers. Through primer designing, system formulation, and PCR condition optimization, a multiplex fluorescent amplification system was constructed. The specificity, sensitivity, and detection ability for mixed samples of this system were investigated, and it was tested using real crime scene materials. In the primer design stage, to reduce the requirements for RNA template quality, the amplification products were set within 80-300 bp. In the system formulation stage, dominant and subordinate primers were mainly considered. By reducing the concentration of dominant primers and increasing that of subordinate primers, a capillary electrophoresis spectrum with an appropriate peak height ratio was finally obtained. Additionally, gradient experiments were designed to adjust the concentrations of PCR reagents and PCR amplification conditions, and multiple versions of DNA amplification enzymes were optimized to achieve the best experimental results. ResultsThrough statistical analysis, there was no significant difference in the capillary electrophoresis of the 3 types of body fluid samples from the two years (2015 and 2024), demonstrating that the sample preservation method in this study can preserve samples for a relatively long time. The composite amplification system constructed in this study exhibited high specificity for all 3 types of body fluid, with no cross-reactions between the markers of each type of body fluid. The minimum detection thresholds for the 3 types of body fluid reached 0.002 9, 0.001 5, and 0.42 mg/L, respectively. This system also had a high degree of discrimination for mixed samples, especially for semen-saliva mixtures, where each body fluid marker could still be successfully detected when the concentration ratio of semen to saliva was 100:1. Meanwhile, in the two actual cases presented in this article, the application of this composite amplification system performed outstandingly. ConclusionThe composite amplification detection system constructed in this study can achieve the correct screening of saliva, semen, and vaginal secretions, overcoming the problems such as low specificity and sensitivity of marker tests and unbalanced RFU values of each marker in previous studies. The specificity and sensitivity meet the practical work requirements, and the operation is simple. It provides an analytical and identification method for body fluid stains in actual case and is applicable to the identification of the tissue origin of biological evidence at crime scenes involving sexual assault, indecent assault, and other criminal acts. In the future, more types of body fluid markers will be screened to expand the types of body fluids detected by the system, and body fluid-specific cSNP and cInDel genetic markers will be introduced to infer the sources (individuals and types) of mixed and complex stains more accurately.
5.Setup Error and Its Influencing Factors in Radiotherapy for Spinal Metastasis
Wenhua QIN ; Xin FENG ; Zengzhou WANG ; Shangnan CHU ; Hong WANG ; Shiyu WU ; Cheng CHEN ; Fukui HUAN ; Bin LIANG ; Tao ZHANG
Cancer Research on Prevention and Treatment 2025;52(5):400-404
Objective To investigate the setup error in patients with spinal bone metastasis who underwent radiotherapy under the guidance of kilovoltage cone-beam CT (KV-CBCT). Methods A total of 118 patients with spinal metastasis who underwent radiotherapy, including 17 cases of cervical spine, 62 cases of thoracic spine, and 39 cases of lumbar spine, were collected. KV-CBCT scans were performed using the linear accelerators from Elekta and Varian’s EDGE system. CBCT images were registered with reference CT images in the bone window mode. A total of 973 data were collected, and 3D linear errors were recorded. Results The patients with spinal bone metastasis were grouped by site, height, weight, and BMI. The P value of the patients grouped only by site was P<0.05, which was statistically significant. Conclusion When grouped by site in the 3D direction, the positioning effect of cervical spine is better than that of thoracic and lumbar spine. The positioning effect of the thoracic spine is better in the head and foot direction but worse in the left and right direction compared with that of the lumbar spine. Instead of extending or narrowing the margin according to the BMI of patients with spinal metastasis, the margin must be changed according to the site of spinal bone metastasis.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Update on the treatment navigation for functional cure of chronic hepatitis B: Expert consensus 2.0
Di WU ; Jia-Horng KAO ; Teerha PIRATVISUTH ; Xiaojing WANG ; Patrick T.F. KENNEDY ; Motoyuki OTSUKA ; Sang Hoon AHN ; Yasuhito TANAKA ; Guiqiang WANG ; Zhenghong YUAN ; Wenhui LI ; Young-Suk LIM ; Junqi NIU ; Fengmin LU ; Wenhong ZHANG ; Zhiliang GAO ; Apichat KAEWDECH ; Meifang HAN ; Weiming YAN ; Hong REN ; Peng HU ; Sainan SHU ; Paul Yien KWO ; Fu-sheng WANG ; Man-Fung YUEN ; Qin NING
Clinical and Molecular Hepatology 2025;31(Suppl):S134-S164
As new evidence emerges, treatment strategies toward the functional cure of chronic hepatitis B are evolving. In 2019, a panel of national hepatologists published a Consensus Statement on the functional cure of chronic hepatitis B. Currently, an international group of hepatologists has been assembled to evaluate research since the publication of the original consensus, and to collaboratively develop the updated statements. The 2.0 Consensus was aimed to update the original consensus with the latest available studies, and provide a comprehensive overview of the current relevant scientific literatures regarding functional cure of hepatitis B, with a particular focus on issues that are not yet fully clarified. These cover the definition of functional cure of hepatitis B, its mechanisms and barriers, the effective strategies and treatment roadmap to achieve this endpoint, in particular new surrogate biomarkers used to measure efficacy or to predict response, and the appropriate approach to pursuing a functional cure in special populations, the development of emerging antivirals and immunomodulators with potential for curing hepatitis B. The statements are primarily intended to offer international guidance for clinicians in their practice to enhance the functional cure rate of chronic hepatitis B.
8.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
9.Update on the treatment navigation for functional cure of chronic hepatitis B: Expert consensus 2.0
Di WU ; Jia-Horng KAO ; Teerha PIRATVISUTH ; Xiaojing WANG ; Patrick T.F. KENNEDY ; Motoyuki OTSUKA ; Sang Hoon AHN ; Yasuhito TANAKA ; Guiqiang WANG ; Zhenghong YUAN ; Wenhui LI ; Young-Suk LIM ; Junqi NIU ; Fengmin LU ; Wenhong ZHANG ; Zhiliang GAO ; Apichat KAEWDECH ; Meifang HAN ; Weiming YAN ; Hong REN ; Peng HU ; Sainan SHU ; Paul Yien KWO ; Fu-sheng WANG ; Man-Fung YUEN ; Qin NING
Clinical and Molecular Hepatology 2025;31(Suppl):S134-S164
As new evidence emerges, treatment strategies toward the functional cure of chronic hepatitis B are evolving. In 2019, a panel of national hepatologists published a Consensus Statement on the functional cure of chronic hepatitis B. Currently, an international group of hepatologists has been assembled to evaluate research since the publication of the original consensus, and to collaboratively develop the updated statements. The 2.0 Consensus was aimed to update the original consensus with the latest available studies, and provide a comprehensive overview of the current relevant scientific literatures regarding functional cure of hepatitis B, with a particular focus on issues that are not yet fully clarified. These cover the definition of functional cure of hepatitis B, its mechanisms and barriers, the effective strategies and treatment roadmap to achieve this endpoint, in particular new surrogate biomarkers used to measure efficacy or to predict response, and the appropriate approach to pursuing a functional cure in special populations, the development of emerging antivirals and immunomodulators with potential for curing hepatitis B. The statements are primarily intended to offer international guidance for clinicians in their practice to enhance the functional cure rate of chronic hepatitis B.
10.Comparison of detection and manifestations of metastatic hepatocellular carcinoma by ultrasound at different frequencies
Hong QIN ; Yuli ZHU ; Qiannan ZHAO ; Feihang WANG ; Hansheng XIA ; Wentao KONG ; Wenping WANG
Chinese Journal of Clinical Medicine 2025;32(3):500-504
Objective To explore the value of high-frequency ultrasound in the detection of metastatic hepatocellular carcinoma and displaying lesion characteristics. Methods A total of 38 paitients with hepatocellular carcinoma satellite lesions within 40 mm of subcutaneous tissue were underwent low-frequency (1-5 MHz) and high-frequency (6-9 MHz) ultrasound. Detection rates and ultrasonic features were compared. Results High-frequency grayscale ultrasound had a higher detection rate (71.1% vs. 36.8%, P<0.001). Subgroup analysis showed higher detection rates with chemotherapy history (88.9% vs. 33.3%, P=0.002), fatty liver (71.9% vs 31.3%, P<0.001) or superficial lesion (within 20 mm, 76.5% vs 41.2%, P=0.031). High-frequency ultrasound also showed clearer margins (P=0.004) and more arterial-phase rim enhancement (P=0.007). Conclusions 6-9 MHz ultrasound detects metastatic hepatocellular carcinoma, especially superficial lesions, more effectively than 1-5 MHz ultrasound and better visualizes characteristics.

Result Analysis
Print
Save
E-mail