1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.A Fitting Method for Photoacoustic Pump-probe Imaging Based on Phase Correction
Zhuo-Jun XIE ; Hong-Wen ZHONG ; Run-Xiang LIU ; Bo WANG ; Ping XUE ; Bin HE
Progress in Biochemistry and Biophysics 2025;52(2):525-532
ObjectivePhotoacoustic pump-probe imaging can effectively eliminate the interference of blood background signal in traditional photoacoustic imaging, and realize the imaging of weak phosphorescence molecules and their triplet lifetimes in deep tissues. However, background differential noise in photoacoustic pump-probe imaging often leads to large fitting results of phosphorescent molecule concentration and triplet lifetime. Therefore, this paper proposes a novel triplet lifetime fitting method for photoacoustic pump-probe imaging. By extracting the phase of the triplet differential signal and the background noise, the fitting bias caused by the background noise can be effectively corrected. MethodsThe advantages and feasibility of the proposed algorithm are verified by numerical simulation, phantom and in vivo experiments, respectively. ResultsIn the numerical simulation, under the condition of noise intensity being 10% of the signal amplitude, the new method can optimize the fitting deviation from 48.5% to about 5%, and has a higher exclusion coefficient (0.88>0.79), which greatly improves the fitting accuracy. The high specificity imaging ability of photoacoustic pump imaging for phosphorescent molecules has been demonstrated by phantom experiments. In vivo experiments have verified the feasibility of the new fitting method proposed in this paper for fitting phosphoometric lifetime to monitor oxygen partial pressure content during photodynamic therapy of tumors in nude mice. ConclusionThis work will play an important role in promoting the application of photoacoustic pump-probe imaging in biomedicine.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Advances in exosomes and Alzheimer's disease
Jin-Ping LIANG ; Yu-Chen ZHU ; Sha-Sha LIU ; Yang SUN ; Bo-Yu KUANG ; Shi-Feng CHU ; Nai-Hong CHEN ; Qi-Di AI ; Yan-Tao YANG
Chinese Pharmacological Bulletin 2024;40(9):1628-1633
Exosomes represent a class of nanoscale extracellular vesicles that facilitate the exchange of genetic information among various cells.Alzheimer's disease(AD)stands as a progressive neurodegenerative disorder characterized by its subtle and advan-cing onset,representing the foremost form of dementia lacking effective therapeutic interventions.Notably,investigations have illuminated the involvement of exosomes in the pathogenesis of AD,attributing diagnostic and therapeutic significance to their role,particularly concerning exosomal microRNAs(miRNA).The miRNAs carried by exosomes serve as potential biomarkers for AD,while also exhibiting potential benefits in ameliorating cognitive dysfunction in individuals afflicted by AD.This article aims to comprehensively review the origins of exosomes(encom-passing both mesenchymal cell-derived exosomes and brain-de-rived exosomes)and their potential as therapeutic agents targe-ting AD.
8.Interpretation of report on cardiovascular health and diseases in China 2023
Ming-Bo LIU ; Xin-Ye HE ; Xiao-Hong YANG ; Zeng-Wu WANG ; Sheng-Shou HU
Chinese Journal of Interventional Cardiology 2024;32(10):541-550
Due to the prominent unhealthy lifestyle of residents,accelerated population aging,and urbanization processes in our country,the impact of cardiovascular disease(CVD)risk factors on public health is becoming increasingly significant.The prevalence of cardiovascular disease(CVD)in China is still on the rise.It is estimated that there are 330 million people with CVD,including 13 million cases of stroke,11.39 million cases of coronary heart disease,8.9 million cases of heart failure,5 million cases of pulmonary heart disease,4.87 million atrial fibrillation,2.5 million cases of rheumatic heart disease,2 million cases of congenital heart disease,45.3 million cases of peripheral arterial disease,and 245 million cases of hypertension.The economic burden of CVD on residents and society is increasingly heavy,making it a significant public health issue.The turning point for the prevention and control of CVD has not yet arrived,and it is urgent to strengthen government-led efforts in CVD prevention and control.
9.Effects of Codonop sis saponins on T cells invasion assay across H9N2 AIV infec-ted pulmonary microvascular endothelium
Chang QIAO ; Xiang LIU ; Bo FENG ; Xiang MU ; Tao ZHANG ; Hong DONG ; Ge HU ; Qian ZHANG
Chinese Journal of Veterinary Science 2024;44(8):1800-1806
In order to investigate the regulatory effect of Codonopsis saponins on the immunosup-pression caused by H9N2 subtype avian influenza virus(AIV)infection,rat pulmonary microvas-cular endothelial cells(RPMECs)were incubated with different concentrations of Codonopsis sap-onins(5,10 and 20 mg/L).The expression level of PD-L1 was detected by RT-PCR and flow cy-tometry,and the contents of TNF-α,IFN-y and IL-10 in supernatant were detected by ELISA kit.The titer of H9N2 AIV in supernatant was detected by plaque method.Then,a co-culture system of RPMECs and T cells was established using a Transwell plate with an aperture of 8 μm to mimic the migration of circulating T cells across microvessels to the site of viral infection.RPMECs were cultured in the upper chamber of Transwell,inoculated with H9N2 AIV,supplemented with 20 mg/L Codonopsis saponins 1 h later,and T cells 36 h later.After 8 h of treatment,T cells in the lower compartment were collected and the proportions of CD4+T cells and CD8+T cells were detected by flow cytometry,the expression levels of IL-2,IFN-y and granzyme B in the superna-tant were detected by ELISA,and the proportions of perforin-1 positive T cells were detected by flow cytometry.The proliferation activity of T cells was detected with the MTT cell proliferation and cytotoxicity assay kit,and the percentage of apoptotic cells was detected by flow cytometry af-ter staining of T cells with Annexin V-FITC/PI.The experimental results showed that Codonopsis saponins could significantly reduce the expression level of PD-L1,IL-10 and TNF-α in RPMECs in-duced by H9N2 AIV infection,and reduce the apoptosis rate of T cells.However,the expression levels of IL-2,IFN-y,perforin-1 and granzyme B in transendothelial migration T cells and the pro-liferation activity of T cells were significantly increased.In this study,Codonopsis saponins can sig-nificantly inhibit the expression of H9N2 AIV-induced PD-L1 in RPMECs,enhance the antiviral function of T cells migrating across the endothelial layer,and enhance the resistance of host to H9N2 AIV.
10.Effect of CD8+CD28-T Cells on Acute Graft-Versus-Host Disease after Haploidentical Hematopoietic Stem Cell Transplantation
An-Di ZHANG ; Xiao-Xuan WEI ; Jia-Yuan GUO ; Xiang-Shu JIN ; Lin-Lin ZHANG ; Fei LI ; ZHEN-Yang GU ; Jian BO ; Li-Ping DOU ; Dai-Hong LIU ; Meng LI ; Chun-Ji GAO
Journal of Experimental Hematology 2024;32(3):896-905
Objective:To investigate the effect of CD8+CD28-T cells on acute graft-versus-host disease(aGVHD)after haploidentical hematopoietic stem cell transplantation(haplo-HSCT).Methods:The relationship between absolute count of CD8+CD28-T cells and aGVHD in 60 patients with malignant hematological diseases was retrospectively analyzed after haplo-HSCT,and the differences in the incidence rate of chronic graft-versus host disease(cGVHD),infection and prognosis between different CD8+CD28-T absolute cells count groups were compared.Results:aGVHD occurred in 40 of 60 patients after haplo-HSCT,with an incidence rate of 66.67%.The median occurrence time of aGVHD was 32.5(20-100)days.At 30 days after the transplantation,the absolute count of CD8+CD28-T cells of aGVHD group was significantly lower than that of non-aGVHD group(P=0.03).Thus the absolute count of CD8+CD28-T cells at 30 days after transplantation can be used to predict the occurrence of aGVHD to some extent.At 30 days after transplantation,the incidence rate of aGVHD in the low cell count group(CD8+CD28-T cells absolute count<0.06/μl)was significantly higher than that in the high cell count group(CD8+CD28-T cells absolute count ≥0.06/μl,P=0.011).Multivariate Cox regression analysis further confirmed that the absolute count of CD8+CD28-T cells at 30 days after transplantation was an independent risk factor for aGVHD,and the risk of aGVHD in the low cell count group was 2.222 times higher than that in the high cell count group(P=0.015).The incidence of cGVHD,fungal infection,EBV infection and CMV infection were not significantly different between the two groups with different CD8+CD28-T cells absolute count.The overall survival,non-recurrent mortality and relapse rates were not significantly different between different CD8+CD28-T cells absolute count groups.Conclusion:Patients with delayed CD8+CD28-T cells reconstitution after haplo-HSCT are more likely to develop aGVHD,and the absolute count of CD8+CD28-T cells can be used to predict the incidence of aGVHD to some extent.The absolute count of CD8+CD28-T cells after haplo-HSCT was not associated with cGVHD,fungal infection,EBV infection,and CMV infection,and was also not significantly associated with the prognosis after transplantation.

Result Analysis