1.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
2.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
3.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
4.Changes and Trends in the microbiological-related standards in the Chinese Pharmacopoeia 2025 Edition
FAN Yiling ; ZHU Ran ; YANG Yan ; JIANG Bo ; SONG Minghui ; WANG Jing ; LI Qiongqiong ; LI Gaomin ; WANG Shujuan ; SHAO Hong ; MA Shihong ; CAO Xiaoyun ; HU Changqin ; MA Shuangcheng, ; YANG Meicheng
Drug Standards of China 2025;26(1):093-098
Objective: To systematically analyze the revisions content and technological development trends of microbiological standards in the Chinese Pharmacopoeia (ChP) 2025 Edition, and explore its novel requirements in risk-based pharmaceutical product lifecycle management.
Methods: A comprehensive review was conducted on 26 microbiological-related standards to summarize the revision directions and scientific implications from perspectives including the revision overview, international harmonization of microbiological standards, risk-based quality management system, and novel tools and methods with Chinese characteristics.
Results: The ChP 2025 edition demonstrates three prominent features in microbiological-related standards: enhanced international harmonization, introduced emerging molecular biological technologies, and established a risk-based microbiological quality control system.
Conclusion: The new edition of the Pharmacopoeia has systematically constructed a microbiological standard system, which significantly improves the scientificity, standardization and applicability of the standards, providing a crucial support for advancing the microbiological quality control in pharmaceutical industries of China.
5.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
6.Intelligent handheld ultrasound improving the ability of non-expert general practitioners in carotid examinations for community populations: a prospective and parallel controlled trial
Pei SUN ; Hong HAN ; Yi-Kang SUN ; Xi WANG ; Xiao-Chuan LIU ; Bo-Yang ZHOU ; Li-Fan WANG ; Ya-Qin ZHANG ; Zhi-Gang PAN ; Bei-Jian HUANG ; Hui-Xiong XU ; Chong-Ke ZHAO
Ultrasonography 2025;44(2):112-123
Purpose:
The aim of this study was to investigate the feasibility of an intelligent handheld ultrasound (US) device for assisting non-expert general practitioners (GPs) in detecting carotid plaques (CPs) in community populations.
Methods:
This prospective parallel controlled trial recruited 111 consecutive community residents. All of them underwent examinations by non-expert GPs and specialist doctors using handheld US devices (setting A, setting B, and setting C). The results of setting C with specialist doctors were considered the gold standard. Carotid intima-media thickness (CIMT) and the features of CPs were measured and recorded. The diagnostic performance of GPs in distinguishing CPs was evaluated using a receiver operating characteristic curve. Inter-observer agreement was compared using the intragroup correlation coefficient (ICC). Questionnaires were completed to evaluate clinical benefits.
Results:
Among the 111 community residents, 80, 96, and 112 CPs were detected in settings A, B, and C, respectively. Setting B exhibited better diagnostic performance than setting A for detecting CPs (area under the curve, 0.856 vs. 0.749; P<0.01). Setting B had better consistency with setting C than setting A in CIMT measurement and the assessment of CPs (ICC, 0.731 to 0.923). Moreover, measurements in setting B required less time than the other two settings (44.59 seconds vs. 108.87 seconds vs. 126.13 seconds, both P<0.01).
Conclusion
Using an intelligent handheld US device, GPs can perform CP screening and achieve a diagnostic capability comparable to that of specialist doctors.
7.Effect of a new type of self-made new bone drill applied to L5/S1 intervertebral disc herniation surgery
Yang-Yang ZHAO ; Dong-Jiao FAN ; Ge-Lin FAN ; Jian ZHANG ; Bo-Wen LI ; Zhi-Hong NIE
Journal of Regional Anatomy and Operative Surgery 2024;33(7):610-613
Objective To investigate the efficacy and safety of a new type of self-made bone drill applied to percutaneous transforaminal endoscopic discectomy for L5/S1 intervertebral disc herniation.Methods The clinical data of 52 patients with L5/S1 intervertebral disc herniation admitted to our hospital were retrospectively analyzed.All patients underwent percutaneous transforaminal endoscopic discectomy,with a new type of self-made bone drill for foraminoplasty during the surgery.The surgical conditions and occurrence of complications were recorded.The pain of patients before surgery,3 days after surgery,3 months after surgery,6 months after surgery,and 1 year after surgery was assessed by visual analogue scale(VAS);and the neurological function improvement before and after surgery was evaluated by Oswestry disability index(ODI).Results All patients underwent successful surgery without serious complications or recurrence after surgery.The VAS and ODI scores of patients 3 days,3 months,6 months,and 1 year after surgery were significantly lower than those before surgery(P<0.05).Conclusion The self-made new bone drill can significantly improve the efficiency of foraminoplasty and ensure surgical safety,with satisfactory early clinical effect.
8.Value of single-phase gonadotropin-releasing hormone stimulation test in diagnosis of central precocious puberty in girls with different levels of body mass index
Wei WANG ; Yi-Fan WANG ; Ya XIAO ; Hong-Ru ZHANG ; Jun SUN ; Wen-Hui SHI ; Jin-Bo LI
Chinese Journal of Contemporary Pediatrics 2024;26(6):592-598
Objective To investigate the value of single-phase gonadotropin releasing hormone(GnRH)stimulation test in the diagnosis of central precocious puberty(CPP)in girls with different levels of body mass index(BMI).Methods A retrospective analysis was performed for the data of 760 girls with breast development before 7.5 years of age who attended the Third Affiliated Hospital of Zhengzhou University from January 2017 to August 2023.According to the results of GnRH stimulation test and clinical manifestations,they were divided into a CPP group(297 girls)and a non-CPP group(463 girls).According to the values of BMI,the girls were divided into a normal weight group(540 girls),an overweight group(116 girls),and an obese group(104 girls).The receiver operating characteristic(ROC)curve was used to investigate the value of single-phase GnRH stimulation test in the diagnosis of CPP in girls with different levels of BMI.Results Luteinizing hormone(LH)/follicle-stimulating hormone at 30 minutes after GnRH stimulation had an area under the curve(AUC)of 0.985 in the diagnosis of CPP,which was higher than the AUC at 0,60,and 90 minutes(P<0.05).LH at 30 minutes had a similar diagnostic value to LH at 60 minutes(P>0.05).LH at 30 minutes was negatively correlated with BMI and BMI-Z value(P<0.05).The AUC for diagnosing CPP in normal weight,overweight,and obese girls at 30 minutes LH was 0.952,0.965,and 0.954,respectively(P<0.05).Conclusions The 30-minute GnRH stimulation test has a good value in the diagnosis of CPP in girls with different levels of BMI and is expected to replace the traditional GnRH stimulation test,but the influence of BMI on LH level should be taken seriously.
9.Construction and simulation of medical resources demand model during epidemic events of infectious diseases
Dong WANG ; Yong-Quan TIAN ; Wei ZHANG ; Hong-Shu ZHOU ; Bo XIE ; Zhen-Yan LI ; Si-Hai FAN ; Su-Juan HUANG
Chinese Journal of Infection Control 2024;23(10):1286-1294
Objective To construct the demand model of four types of medical resources including beds in hospi-tal,beds in intensive care unit(ICU),ventilators and medical human resources during the major infectious disease epidemic events,simulate and analyze the treatment of infectious diseases when different medical resources are in short supply.Methods Based on the susceptible-exposed-infectious-recovered(SEIR)model,considering the infec-tivity of infected persons,the susceptibility of the population and the immunity of convalescents,the characteristics of asymptomatic COVID-19 patients and different clinical types,the"COVID-19 infection-hospitalization model"was constructed.By collecting and setting the parameters of disease transmission,clinical course and medical re-source shortage scenarios,an analysis model of allocation and supply of urban medical resources during infectious di-sease epidemic events was initially formed based on Anylogic platform,the supply and demand of medical resources during infectious disease events in different scenarios were analyzed.Results In the non-intervention scenario,the peak time of bed demand was on the 107th day,and the peak value was 160.92 beds per thousand people;the peak time of ventilator demand was on the 122nd day,and the peak value was 5.61 units per thousand people;the peak time of ICU bed demand was on the 117th day,and the peak value was 12.78 beds per thousand people;the peak time of the demand for medical human resources was on the 109th day,and the peak value was 151.12 persons per thousand persons.The simulation results suggested that there were some differences in the impact of different medi-cal resources on the outcome of medical treatment.Conclusion This study constructs an analytical tool for the allo-cation and supply of urban medical resources under the epidemic events of infectious diseases,and the results of mul-tiple simulation experiments suggest that bed resources and medical human resources play more important roles in the outcome of medical treatment.
10.Quality monitoring indicator system in blood banks of Shandong: applied in blood donation services, component preparation and blood supply process
Yuqing WU ; Hong ZHOU ; Zhijie ZHANG ; Zhiquan RONG ; Xuemei LI ; Zhe SONG ; Shuhong ZHAO ; Zhongsi YANG ; Qun LIU ; Lin ZHU ; Xiaojuan FAN ; Shuli SUN ; Wei ZHANG ; Jinyu HAN ; Haiyan HUANG ; Guangcai LIU ; Ping CHEN ; Xianwu AN ; Hui ZHANG ; Junxia REN ; Xuejing LI ; Chenxi YANG ; Bo ZHOU ; Hui YE ; Mingming QIAO ; Hua SHEN ; Dunzhu GONGJUE ; Yunlong ZHUANG
Chinese Journal of Blood Transfusion 2024;37(3):275-282
【Objective】 To establish an effective quality indicator monitoring system, scientifically and objectively evaluate the quality management level of blood banks, and achieve continuous improvement of quality management in blood bank. 【Methods】 A quality monitoring indicator system that covers the whole process of blood collection and supply was established, the questionnaire of Quality Monitoring Indicators for Blood Collection and Supply Process with clear definition of indicators and calculation formulas was distributed to 17 blood banks in Shandong. Statistical analysis of 21 quality monitoring indicators in terms of blood donation service (10 indicators), blood component preparation (7 indicators ), and blood supply (4 indicators) from each blood bank from January to December 2022 were conducted using SPSS25.0 software The differences in quality monitoring indicators of blood banks of different scales were analyzed. 【Results】 The average values of quality monitoring indicators for blood donation service process of 17 blood banks were as follows: 44.66% (2 233/5 000) of regular donors proportion, 0.22% (11/50) of adverse reactions incidence, 0.46% (23/5 000) of non-standard whole blood collection rate, 0.052% (13/25 000) of missed HBsAg screening rate, 99.42% (4 971/5 000) of first, puncture successful rate, 86.49% (173/200) of double platelet collection rate, 66.50% (133/200) of 400 mL whole blood collection rate, 99.25% (397/400) of donor satisfaction rate, 82.68% (2 067/2 500) of use rate of whole blood collection bags with bypass system with sample tube, and 1 case of occupational exposure in blood collection.There was a strong positive correlation between the proportion of regular blood donors and the collection rate of 400 mL whole blood (P<0.05). The platelet collection rate, incidence of adverse reactions to blood donation, and non-standard whole blood collection rate in large blood banks were significantly lower than those in medium and small blood banks (P<0.05). The average quality monitoring indicators for blood component preparation process of 17 blood banks were as follows: the leakage rate of blood component preparation bags was 0.03% (3/10 000), the discarding rate of lipemic blood was 3.05% (61/2 000), the discarding rate of hemolysis blood was 0.13%(13/10 000). 0.06 case had labeling errors, 8 bags had blood catheter leaks, 2.76 bags had blood puncture/connection leaks, and 0.59 cases had non-conforming consumables. The discarding rate of hemolysis blood of large blood banks was significantly lower than that of medium and small blood banks (P<0.05), and the discarding rate of lipemic blood of large and medium blood banks was significantly lower than that of small blood banks (P<0.05). The average values of quality monitoring indicators for blood supply process of 17 blood banks were as follows: the discarding rate of expired blood was 0.023% (23/100 000), the leakage rate during storage and distribution was of 0.009%(9/100 000), the discarding rate of returned blood was 0.106% (53/50 000), the service satisfaction of hospitals was 99.16% (2 479/2 500). The leakage rate of blood components during storage and distribution was statistically different with that of blood component preparation bags between different blood banks (P<0.05). There were statistically significant differences in the proportion of regular blood donors, incidence of adverse reactions, non-standard whole blood collection rate, 400 mL whole blood collection rate, double platelet collection rate, the blood bag leakage rate during preparation process, the blood components leakage rate during storage and distribution as well as the discarding rate of lipemic blood, hemolysis blood, expired blood and returned blood among large, medium and small blood banks (all P<0.05). 【Conclusion】 The establishment of a quality monitoring indicator system for blood donation services, blood component preparation and blood supply processes in Shandong has good applicability, feasibility and effectiveness. It can objectively evaluate the quality management level, facilitate the continuous improvement of the quality management system, promote the homogenization of blood management in the province and lay the foundation for future comprehensive evaluation of blood banks.

Result Analysis