1.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
2.Correlation between hemoglobin,anemia and sarcopenia in the elderly population
Hong-Zhen CHEN ; Kun ZHENG ; Xiao-Xue WU ; Li XIA
Medical Journal of Chinese People's Liberation Army 2025;50(4):444-451
Objective To analyze the correlation between hemoglobin(Hb),anemia,and sarcopenia in the elderly population in Chongqing communities.Methods A cross-sectional study was conducted on elderly individuals who underwent healthy examinations at 5 community health service centers in Chongqing from March to August 2023.Demographic characteristics,social factors,body composition measurement,grip strength,6-meter gait speed and blood tests were assessed.Receiver operating characteristic(ROC)curve was utilized to evaluate the accuracy of Hb in predicting sarcopenia,and the Youden index was employed to determine the optimal Hb cut-off value for diagnosing sarcopenia and its components.Both unadjusted and adjusted logistic regression analyses were performed to examine the relationship between Hb and anemia with sarcopenia and its components.Results A total of 531 elderly populations were included,with an average age of(71.1±6.5)years.The overall prevalence of sarcopenia was 13.6%(72/531),including 29 males(40.3%)and 43 females(59.7%).Unadjusted analyses showed that Hb was correlated with sarcopenia,decreased muscle mass,slower gait speed,and reduced grip strength(P<0.05).After adjusting for all potential risk factors,Hb was still significantly associated with sarcopenia and reduced grip strength(P<0.05).For every 10 g/L increase in Hb,the risk of sarcopenia decreased by 2.3%,and the risk of reduced grip strength decreased by 1.7%(P<0.05).Anemia was correlated with sarcopenia,reduced muscle mass,and decreased grip strength in unadjusted analyses(P<0.05),while the correlation between anemia and reduced grip strength remained significant after adjustment for all potential risk factors(P<0.05).The optimal Hb cut-off value for diagnosing sarcopenia in males and females were 148 g/L and 128 g/L,respectively.Conclusions Hb is an independent risk factor for sarcopenia and reduced grip strength.Anemia is associated with sarcopenia,but is not an independent risk factor for sarcopenia.
3.Predictive value of toe-to-room temperature gradient for 28 d mortality in sepsis patients:a single center prospective observational clinical study
Lu-Lan LI ; Yi-Lin LIU ; Yong LIU ; Shao-Wu CHEN ; Hong-Bin HU ; Zhen-Hua ZENG
Medical Journal of Chinese People's Liberation Army 2025;50(5):536-544
Objective To investigate the predictive value of temperature gradients on the mortality of sepsis patients and their correlation with fluid input.Methods By means of a prospective observational method,154 patients with sepsis or septic shock admitted to the Department of Critical Care Medicine at Nanfang Hospital,Southern Medical University from November 2019 to November 2021 were included as research subjects.They were divided into a survivor group(n=118)and a non-survivor group(n=36)according to whether they survived within 28 days.The core-to-toe temperature gradient(CTTG)and toe-to-room temperature gradient(TRTG)were monitored and calculated immediately upon admission to the intensive care unit(ICU)and 6 hours after admission.Receiver operating characteristic(ROC)curve was used to explore the predictive value of temperature gradients on mortality,and multivariate Cox regression analysis was performed to explore the risk factors of 28-day mortality in sepsis patients.The results were verified through survival analysis.Correlation analysis and multivariate analysis of variance were used to explore the correlation between temperature gradients and fluid input,as well as noradrenaline doses.Results Among the 154 patients,118 survived within 28 days(survivor group),and 36 died(non-survivor group).ROC curve and multivariate Cox regression analysis showed that a toe-to-room temperature gradient of≤5.35℃within 6 hours after admission was a risk factor for 28-day mortality.Compared with patients with a high toe-to-room temperature gradient(>5.35℃),patients with a low toe-to-room temperature gradient(≤5.35℃)had a 2.74-fold increase in the risk of 28-day mortality(P=0.004,95%CI 1.54,9.12).The CTTG and TRTG upon admission to the ICU and 6 hours after admission were not significantly associated with fluid input or noradrenaline doses(P>0.05).Conclusions A toe-to-room temperature gradient of less than or equal to 5.35℃within 6 hours after ICU admission is a risk factor for 28-day mortality in sepsis patients.The improvement of temperature gradients at different time points is not associated with fluid input.
4.Establishment and evaluation of a predictive model for spontaneous peritonitis in HBV-related primary liver cancer
Hong-Yan WEI ; Yong-Zhen CHEN ; Ren-Hai TIAN ; Li-Xian CHANG ; Ying-Yuan ZHANG ; Dan-Qing XU ; Chun-Yun LIU ; Li LIU
Medical Journal of Chinese People's Liberation Army 2025;50(8):949-957
Objective To establish and evaluate a nomogram prediction model for spontaneous peritonitis in HBV-related primary liver cancer.Methods A retrospective study was conducted on 1298 patients with HBV-related primary liver cancer hospitalized in the Kunming Third People's Hospital from January 2012 to December 2022.General data and serological indicators were collected,and patients were divided into infection group(n=262)and control group(n=1036)based on the occurrence of spontaneous peritonitis.Univariate and LASSO regression analyses were used to screen variables,followed by binary logistic regression to analyze the influencing factors of spontaneous peritonitis in HBV-related primary liver cancer patients,leading to the establishment of a nomogram prediction model.Finally,the Hosmer-lemeshow(H-L)goodness of fit test,receiver operating characteristic(ROC)curve,calibration curve,decision curve analysis(DCA)and clinical impact curve(CIC)were utilized to evaluate the fit degree,accuracy,calibration,and clinical practicability of the nomogram prediction model.Results Single factor analysis revealed significant differences between infection group and control group in portal vein cancer thrombus(PVTT),Child-Pugh grade,China Liver Cancer Staging(CNLC)stage,alcohol consumption history,smoking history,white blood cell count(WBC),neutrophil count(NE),hemoglobin(Hb),fibrinogen(FIB),abnormal prothrombin(PIVKA-Ⅱ),aspartate aminotransferase(AST),alanine aminotransferase(ALT),total protein(TP),prealbumin(PA),γ-glutamyltransferase(GGT),alkaline phosphatase(ALP),cholinesterase(CHE),total bile acid(TBA),total cholesterol(TC),low density lipoprotein(LDL),creatinine(Cr),HBV DNA,CD3+T cells count,CD4+T cells count,CD8+T cells count,CD4+T cells/CD8+T cells ratio,procalcitonin(PCT),serum amyloid A(SAA),interleukin-6(IL-6),high-sensitivity C-reactive protein(hs-CRP),alpha-fetoprotein(AFP),and IL-4(P<0.05).LASSO regression analysis identified 5 variables:Child-Pugh grade,PVTT,WBC,CHE and hs-CRP.Binary logistic regression analysis indicated that Child-Pugh grade(Grade B:OR=5.780,95%CI 3.271-10.213,P<0.001;Grade C:OR=14.818,95%CI 7.697-28.526,P<0.001),PVTT(OR=2.893,95%CI 2.037-4.108,P<0.001),WBC(OR=1.088,95%CI 1.031-1.148,P=0.002),and hs-CRP(OR=1.005,95%CI 1.001-1.010,P=0.026)were the independent risk factors of spontaneous peritonitis in HBV-related primary liver cancer patients.Using these 4 variables,a nomogram prediction model was constructed and evaluated.The P-value of the H-L goodness of fit test was 0.760.Moreover,the area under ROC curve(AUC)was 0.866,with a sensitivity of 0.870 and a specificity of 0.716.The average absolute error of the calibration curve is 0.022.DCA and CIC analyses demonstrated that the nomogram prediction model possessed some clinical utility.Conclusion The nomogram prediction model for spontaneous peritonitis in HBV-related primary liver cancer patients,constructed using Child-Pugh grade,PVTT,WBC and hs-CRP,exhibits a high fitting degree and accuracy,with the prediction probability highly consistent with the actual occurrence probability,and possesses certain clinical practicability.
5.Analysis of factors influencing global longitudinal strain based on cardiac magnetic resonance after acute myocardial infarction
Ke LIU ; Yi-Qing ZHAO ; Zhen-Yan MA ; Xin A ; Li LI ; Wei-Ran KONG ; Lei ZHAO ; Hong-Bo ZHANG ; Ying ZHANG ; Geng QIAN
Medical Journal of Chinese People's Liberation Army 2025;50(11):1382-1389
Objective To investigate the factors influencing global longitudinal strain(GLS)measured by cardiac magnetic resonance(CMR)in patients with acute ST-segment elevation myocardial infarction(STEMI).Methods Clinical data of 315 hospitalized patients diagnosed with acute STEMI who underwent percutaneous coronary intervention(PCI)at the First Medical Center of Chinese PLA General Hospital from June 2016 to September 2021 were retrospectively collected.After analyzing CMR images of all patients,GLS and other strain parameters were obtained,and then the patients were divided into two groups according to the median GLS.In order to balance gender and age differences,1:1 propensity score matching was performed,and 206 patients were eventually included:GLS>-11.3%group(indicating severe GLS impairment,n=103)and GLS≤-11.3%group(n=103).Baseline characteristics,laboratory indicators,coronary angiographic parameters,electrocardiogram(ECG)features,and CMR parameters were compared between the two groups.Variables showing significant differences were analyzed for their correlation with GLS.Multivariate logistic regression and multiple stepwise linear regression analyses were performed to identify factors associated with GLS impairment.Results Compared with GLS≤-11.3%group,GLS>-11.3%group had significantly higher peak levels of creatine kinase-MB(CK-MB)and troponin T(TnT)(P<0.001).A higher proportion of patients in GLS>-11.3%group had the left anterior descending artery(LAD)as the culprit vessel,while a lower proportion had the right coronary artery(RCA)as the culprit vessel(P<0.001).Additionally,GLS>-11.3%group had longer QRS duration(P<0.001)and a higher incidence of pathological Q waves(P=0.001).Regarding CMR parameters,GLS>-11.3%group exhibited larger global circumferential strain(GCS),infarct size(IS),and left ventricular end-systolic volume(LVESV),as well as lower global radial strain(GRS)and left ventricular ejection fraction(LVEF)(P<0.001).Multivariate logistic regression indicated that peak TnT(OR=1.092,P=0.001),LAD culprit vessel(OR=3.744,P<0.001),and QRS duration(OR=1.026,P<0.001)were significantly associated with severely impaired GLS.Multiple stepwise linear regression analysis showed that the logarithmic value of peak TnT,LAD as the culprit vessel,and the square root of QRS duration were linearly correlated with GLS values(adjusted R2=0.301,P<0.001),and these independent variables explained 30.1%of the variation in GLS.Conclusion Elevated peak TnT,prolonged QRS duration,and LAD as the culprit vessel are significantly associated with severe GLS impairment in STEMI patients,indicating more severe myocardial infarction and worse left ventricular function.
6.Anatomical structures of the matrix channel network for interstitial fluid flow in the human hand
Tian-Tian LI ; Jian-Ping ZHAO ; Chao-Zhi YANG ; Zhen CHEN ; Nai-Li WANG ; Bei LI ; Jin CAI ; Xiao-Yu WANG ; Hong-Yi LI
Acta Anatomica Sinica 2025;56(3):307-314
Objective To investigate the anatomical and microscopic structures of interstitial fluid flow channels in the skin tissue of hand dorsum in human cadavers.Methods Totally 7 fresh cadavers within 12 hours post-mortem were included.MRI was used to observe the distribution of interstitial fluid flow from the first phalanx of the fingers to the wrist,precisely locating the flow channels.Based on imaging results,histological analyses were conducted to determine the histological characteristics of the flow channels.Furthermore,multi-immunofluorescence and microcomputed tomography(Micro-CT)techniques were employed to analyze the channels,and image post-processing was used to elucidate their anatomical structures at the microscopic level.Results After injecting a contrast agent into the first phalanx of ten finger specimens and applying repeated pressure,MRI image revealed centripetal long-range interstitial fluid flow along channels distinct from blood vessels and lymphatic vessels.Histological analysis and Micro-CT further confirmed that the flow primarily occurred within the fibrous connective tissue and adventitia of the skin.Conclusion The orderly fibrous connective tissue and adventitia in the skin form the interstitial fluid flow channels in the human hand dorsum skin,named as"stromal membrane channels"in the skin.
7.Development of A High-performance Rectangular Ion Trap for Multi-reflection Time-of-Flight Mass Spectrometer
Xiao-Xia CHEN ; Yi REN ; Qi HUANG ; Da-Jun XIANG ; Chang-Wei LI ; Yi HONG ; Lei LI ; Zheng-Xu HUANG ; Mei LI ; Jing-Wei XU ; Zhen ZHOU
Chinese Journal of Analytical Chemistry 2025;53(1):38-46
As a new generation of time-of-flight mass spectrometry,multiple-reflection time-of-flight mass spectrometry(MR-TOF-MS)has been increasingly applied in the fields such as nuclear physics,chemistry,and biology due to its ultra-high resolution and rapid analysis capabilities.However,the analytical performance of MR-TOF-MS largely depends on the ion bunch state entering the mass analyzer.In this study,a rectangular ion trap(RIT)was developed,designed and processed using printed circuit board technology,as an ion accumulating and focusing device for MR-TOF mass analyzer.Compared to traditional ion traps composed of two sets of planar electrodes,this RIT had higher voltage utilization efficiency,resulting in more efficient ion collection and focusing.The ions were cooled to a sufficiently small bunch for precise mass measurement with MR-TOF-MS mass spectrometry in only 1 ms of cooling time in the RIT,then orthogonally ejected to the MR-TOF mass spectrometer for mass analysis.Experimental results indicated that the working cycle,ion flux,and ion focusing state of the RIT fully met the requirements of the MR-TOF mass analyzer.When coupled with the MR-TOF mass analyzer,the RIT enabled MR-TOF-MS to achieve a mass resolution of 1.5×105.
8.Atomic Fluorescence Dispersion Detection Technique Based on Area Array Single Photon Counting Imaging Detector
Chen TAO ; Hong-Ji ZHANG ; Chun-Sheng LI ; Ling-Ping HE ; Zhen-Yu MA ; Bo CHEN ; Ran ZHANG
Chinese Journal of Analytical Chemistry 2025;53(2):187-194
The single photon counting imaging detector based on microchannel plate(MCP)has the characteristics of high sensitivity and low dark count rate,and has been applied to the optical remote sensing detection of weak ultraviolet spectral signals in space.In this work,by using planar array single photon counting imaging detector as the detector,flat-field concave grating as the splitter,and electrodeless discharge lamp(EDL)as the excitation light source,a dispersion detection system suitable for hydride generation-atomic fluorescence spectrometry(HG-AFS)was developed.The wavelength calibration of the system was carried out,and the negative high pressure and EDL stability time of the planar array single photon counting imaging detector were analyzed and optimized.The characteristic emission spectral lines of As and Bi elements excited in the wavelength range of 180-320 nm were analyzed,and the scattering interference in the wavelength range of 257.3-306.7 nm was discussed.The results showed that the AFS dispersion detection system based on the planar array single photon counting imaging detector could detect and analyze the HG-AFS fluorescence signal initially,and the influence of scattering interference on the detection results was effectively avoided.The system had the advantages including simple structure,no refrigeration and temperature control,no moving parts and simultaneous measurement of multi-band.
9.Dual-modal Magnetic Resonance Imaging Contrast Agents Based on Polymetallic Nanoclusters for Targeted Diagnosis of Prostate Cancer
Qing-Dong LI ; Peng WANG ; Jian-Min XIAO ; Wen-Juan GAO ; Zhen-Hong XIA ; Gui-Long ZHANG ; Zheng-Yan WU
Chinese Journal of Analytical Chemistry 2025;53(4):602-611
Fe/Mn/Gd polymetallic nanooxide(FMGN)were prepared by one-step solvent thermal reaction by using Fe(acac)3,Mn(acac)2 and Gd(acac)3 as reaction precursors.Next,hyaluronic acid(HA)was used to modify FMGN to fabricate tumor-targeting T 1-T 2 dual-mode magnetic resonance imaging(MRI)contrast agent(HA-FMGN)for accurate diagnosis of prostate cancer.The structure and morphology of FMGN were observed by transmission electron microscope(TEM).It was found that FMGN exhibited a uniform nanocluster spherical structure when the feeding ratio of iron acetylacetonate,manganese acetylacetonate,and gadolinium acetylacetonate was 3:2:1.X-ray diffraction(XRD)analysis showed that FMGN had a typical inverse spinel structure of Mn doped Fe 3O 4,with Gd existing in the form of amorphous gadolinium oxide.The longitudinal relaxivity(r 1)and transverse relaxivity(r 2)of FMGN were 13.395 and 428.535 L/(mmol·s),respectively,measured by 0.5 T MRI analyzer,which proved that FMGN had excellent T 1-T 2 dual-mode MRI contrast capability.The cytotoxicity and hemolysis test found that HA-FMGN didn't damage red cells and induce toxicity for normal cells,indicating that HA-FMGN had excellent cell biocompatibility.The internalization efficacy of HA-FMGN was observed by CLSM,and the results showed that HA-FMGN possessed excellent prostate tumor-targeting ability.In vivo MRI experiment showed that HA-FMGN significantly enhanced T 1 and T 2 weighted MRI signal to noise ratio(SNR)of prostate tumor,which promoted the accurate diagnosis of orthotopic prostate cancer.
10.Validation and Forensic Application of a Domestic Human DNA Quantitative De-tection Kit
Jing CHEN ; Ya-Ping WANG ; Yun-Peng FENG ; Xiao-Xin HU ; Zhen-Jun JIA ; Hong-Di LIU ; An-Xin YAN ; Yong-Jiu LI ; Zhu PENG ; Zhi-Fang LIU ; Jian-Gang CHEN
Journal of Forensic Medicine 2025;41(3):252-259
Objective To verify the efficacy of a domestic human DNA quantification kit based on real-time fluorescence quantitative PCR in detecting the total human DNA concentration,male DNA concen-tration in mixed male/female DNA samples,the degree of DNA degradation and inhibitor tolerance.Methods Samples with different concentrations,different male/female ratios,different concentrations of inhibitors,and different degradation degrees were tested using the domestic human DNA quantification kit based on real-time fluorescence quantitative PCR.This kit was compared with a similar product on the market and was applied to the detection of DNA from real cases.Results This human DNA quan-tification kit can effectively detect human DNA as low as 0.001 65 ng/μL,and 6.25 pg/μL of male DNA in mixed samples with a male-to-female ratio of 1∶15 000.Even when the sample contains as high as 400 ng/μL of humic acid or 1 000 μmol/L of hemin alone,the DNA concentration can still be accurately detected.The degradation index can effectively characterize the degradation degree of the sample.This kit has been successfully applied in forensic practice.Conclusion This human DNA quan-tification kit is accurate and reliable in detection.It can accurately reflect the degradation of DNA and inhibitor tolerance.It has good performance in quantitative accuracy,determination of the male/female ratio in mixed samples,and inhibitor tolerance.It has application potential in forensic case examination.


Result Analysis
Print
Save
E-mail