1.Compilation Instruction and Key Point Interpretation for Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration
Wenzhe LI ; Rui MA ; Xiaoxiao ZHAO ; Hong HUA ; Xin CUI ; Yanming XIE ; Lianxin WANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):260-266
To develop the Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration in response to common problems, including insufficient safety information in package inserts, amplified medication risks in special populations, and non-standard clinical practices, thus establishing a risk management system tailored to the characteristics of Chinese patent medicines for mucosal administration. An approach combining qualitative and quantitative methods was adopted. In accordance with the Drug Administration Law of the People's Republic of China (2019 revision) and the GB/T 1.1—2020 standard, a systematic search was performed in the Chinese Pharmacopoeia (2020 edition), the Catalog of Medicines Covered by Medical Insurance (2022 edition), Chinese databases [China Network of Knowledge Infrastructure (CNKI), Wanfang Data (Wanfang), and VIP journal resource integration service platform (VIP)], and international databases (Cochrane Library, PubMed, and EMbase). Guideline outlines were developed through questionnaire surveys, expert interviews, and the nominal group technique. The content of each item was formulated with full consideration of traditional Chinese medicine (TCM) incompatibility, as well as the conceptual connotations and extensions of pharmacovigilance. The results included 54 Chinese patent medicines for mucosal administration from the Chinese Pharmacopoeia (2020 edition) and 58 from the Catalog of Medicines Covered by Medical Insurance (2022 edition). Safety-related items in the corresponding package inserts were collected, and 27 relevant publications were retrieved. Thirty experts from 24 institutions were mobilized for the drafting, and opinions from 61 external experts were solicited. A pharmacovigilance framework was established, covering the full chain of "monitoring, identification, assessment, and control". Based on seven anatomical sites, including nasal, ocular, and oral mucosa, a stratified monitoring system was constructed. The guideline proposed key recommendations on improving package insert sections such as "Adverse Reactions", "Contraindications", and "Precautions", clinical procedure standardization in healthcare institutions, risk control, and dynamic pharmacovigilance. The Guideline provides evidence-based support tailored to the risk profile of Chinese patent medicines for mucosal administration, filling the current gap in international pharmacovigilance standards in this field, while offering technical support for safety management across the full life cycle of medicines for mucosal administration.
2.Compilation Instruction and Key Point Interpretation for Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration
Wenzhe LI ; Rui MA ; Xiaoxiao ZHAO ; Hong HUA ; Xin CUI ; Yanming XIE ; Lianxin WANG
Chinese Journal of Experimental Traditional Medical Formulae 2026;32(8):260-266
To develop the Pharmacovigilance Guidelines for Clinical Application of Chinese Patent Medicines for Mucosal Administration in response to common problems, including insufficient safety information in package inserts, amplified medication risks in special populations, and non-standard clinical practices, thus establishing a risk management system tailored to the characteristics of Chinese patent medicines for mucosal administration. An approach combining qualitative and quantitative methods was adopted. In accordance with the Drug Administration Law of the People's Republic of China (2019 revision) and the GB/T 1.1—2020 standard, a systematic search was performed in the Chinese Pharmacopoeia (2020 edition), the Catalog of Medicines Covered by Medical Insurance (2022 edition), Chinese databases [China Network of Knowledge Infrastructure (CNKI), Wanfang Data (Wanfang), and VIP journal resource integration service platform (VIP)], and international databases (Cochrane Library, PubMed, and EMbase). Guideline outlines were developed through questionnaire surveys, expert interviews, and the nominal group technique. The content of each item was formulated with full consideration of traditional Chinese medicine (TCM) incompatibility, as well as the conceptual connotations and extensions of pharmacovigilance. The results included 54 Chinese patent medicines for mucosal administration from the Chinese Pharmacopoeia (2020 edition) and 58 from the Catalog of Medicines Covered by Medical Insurance (2022 edition). Safety-related items in the corresponding package inserts were collected, and 27 relevant publications were retrieved. Thirty experts from 24 institutions were mobilized for the drafting, and opinions from 61 external experts were solicited. A pharmacovigilance framework was established, covering the full chain of "monitoring, identification, assessment, and control". Based on seven anatomical sites, including nasal, ocular, and oral mucosa, a stratified monitoring system was constructed. The guideline proposed key recommendations on improving package insert sections such as "Adverse Reactions", "Contraindications", and "Precautions", clinical procedure standardization in healthcare institutions, risk control, and dynamic pharmacovigilance. The Guideline provides evidence-based support tailored to the risk profile of Chinese patent medicines for mucosal administration, filling the current gap in international pharmacovigilance standards in this field, while offering technical support for safety management across the full life cycle of medicines for mucosal administration.
3.Efficacy of audiovisual training on ameliorating core symptoms in children with autism spectrum disorder
QU Zhiyi, LIU Zhao, LI Yi, HE Yingli, CHE Hong, ZHANG Xin
Chinese Journal of School Health 2026;47(5):646-651
Objective:
To explore the effect of a computer assisted audiovisual combined intervention model on the core symptoms of children with autism spectrum disorder (ASD), in order to provide references for enriching intervention and treatment methods for ASD children.
Methods:
From December 2023 to March 2024, 36 ASD children aged 4-8 years were recruited from Tianjin Disabled Persons Rehabilitation Center and Xinxinyu Children s Rehabilitation Center, and were divided into a training group (22 cases) and a control group (14 cases). The training group completed a 12 week audiovisual training course (visual sessions:twice a week, for 50-60 minutes each session; auditory sessions:three times a week, for 15 minutes each time), while the control group received only conventional treatment interventions. Before and after the intervention, the core symptoms of ASD children were assessed using the Short Sensory Profile (SSP), Social Responsiveness Scale (SRS), and Repetitive Behavior Questionnaire-2 ( RBQ- 2). Eye tracking experiments were used to test preferences for social attention.
Results:
Before the intervention, there were no statistically significant differences in the total scores and factor scores of the SSP and RBQ-2 scales between the two groups ( t =-1.63, 0.38, both P >0.05). The SRS total score, social communication, and restricted interests and repetitive behavior factor scores of the training group (90.68±25.83, 33.36±11.80, 15.64±7.00) were significantly higher than those of the control group (72.29±19.84, 24.93±7.85, 10.21±5.67) ( t =2.27, 2.36, 2.43, all P <0.05). Children in the training group with higher social communication factor scores before the intervention scored lower than the control group at the post intervention test (simple slope=-14.17, t =-2.48, P = 0.02), while there was no statistically significant difference in post intervention scores between children with lower social communication factor scores before the intervention and the control group (simple slope=2.31, t =0.57, P >0.05). Eye tracking experiments showed that the total fixation time on geometric images decreased significantly more in the training group [ -4.56 (-11.42, 1.21)] compared to the control group [6.55 (-0.32, 16.53)] after the intervention ( Z=2.48, P <0.05).
Conclusions
The computer assisted audiovisual intervention model can effectively improve the core symptoms of ASD children with poorer social communication levels. The promotion of the intervention model needs to consider individual differences in ASD.
4.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
5.Noninvasive Screening for Chronic Atrophic Gastritis Using Photoplethysmography-derived Meridian-labelled Harmonic Parameters
Yun-Qing LE ; Jian-Xin CHEN ; Ai-Ping CHEN ; Zhi-Hong LI
Progress in Biochemistry and Biophysics 2026;53(5):1178-1194
ObjectiveChronic atrophic gastritis (CAG) is usually diagnosed by gastroscopy and histopathological biopsy. These procedures remain the reference standard, but their invasive nature and resource requirements may limit their use in large-scale population screening and repeated follow-up. A convenient and reproducible method for noninvasive auxiliary screening may help identify individuals who require further endoscopic assessment. Fingertip photoplethysmography (PPG) provides a noninvasive recording of peripheral pulse waves and allows harmonic features to be extracted from the signal. In this study, the so-called meridian-related variables were defined as PPG-derived harmonic parameters labelled according to meridian nomenclature, rather than as direct measurements of meridian physiology. This study aimed to compare these harmonic parameters between patients with CAG and non-CAG controls, identify parameters that remained different after age adjustment, and develop a multivariable model for noninvasive auxiliary screening and pre-endoscopic risk stratification of CAG. MethodsA total of 343 participants were included, comprising 171 patients with CAG and 172 non-CAG controls. CAG diagnosis was established using gastroscopy and histopathology as the reference standard. Fingertip PPG signals were collected using a PPG-based pulse acquisition device. Eight PPG-derived harmonic parameters labelled according to meridian nomenclature were extracted for analysis. Between-group differences were first assessed using nonparametric tests. Age-adjusted analyses were then performed to reduce potential confounding by age. The false discovery rate (FDR) method was applied for multiple-comparison correction. A multivariable logistic regression model integrating age and multiple harmonic parameters was constructed. Model performance was evaluated using receiver operating characteristic (ROC) analysis and the area under the curve (AUC). Internal validation performance was assessed using stratified five-fold cross-validation and bootstrap optimism correction. Threshold performance was examined using both a high-specificity strategy and a Youden index-based cutoff. Decision curve analysis was used to evaluate the model’s net clinical benefit across a range of threshold probabilities. ResultsAll eight harmonic parameters were non-normally distributed. In the univariate analysis, the stomach-labelled harmonic parameter (ST), bladder-labelled harmonic parameter (BL), and liver-labelled harmonic parameter (LR) differed between the CAG and non-CAG groups. After age adjustment and FDR correction, only ST and BL remained statistically significant. Compared with non-CAG controls, patients with CAG showed higher ST values and lower BL values. This finding indicates an associated differential harmonic pattern that was not fully explained by age distribution. However, the discriminative ability of a single harmonic parameter was limited. The best-performing single indicator was ST, with an AUC of 0.652 (95% CI: 0.595-0.707). The multivariable model integrating age and multiple harmonic parameters achieved an AUC of 0.791 (95% CI: 0.743-0.835), representing an improvement of 0.139 over ST alone. In internal validation, stratified five-fold cross-validation yielded a mean AUC of 0.753 (95% CI: 0.715-0.781), and the bootstrap optimism-corrected AUC was 0.748. These results suggest that the model retained moderate discriminative performance after internal validation.At a specificity of at least 95%, the model achieved a sensitivity of only 40.4% (95% CI: 25.7%-49.7%). This high-specificity cutoff may be suboptimal as the preferred threshold for an initial screening setting because of the potential risk of missed CAG cases. The Youden index-based optimal cutoff was 0.419, corresponding to a sensitivity of 80.7% and a specificity of 62.8%. This threshold may better match the practical aim of noninvasive auxiliary screening, where sensitivity is usually prioritized to reduce missed cases. Decision curve analysis showed that, within a threshold probability range of 10%-55%, the model provided higher net clinical benefit than the reference strategies of recommending gastroscopy for all participants or for none. ConclusionPatients with CAG showed associated harmonic differences in fingertip PPG-derived features, mainly characterized by higher ST and lower BL values after age adjustment and FDR correction. Compared with a single harmonic parameter, the multivariable model showed better overall discrimination and retained moderate internal validation performance. These findings suggest that PPG-derived harmonic parameters labelled according to meridian nomenclature may provide auxiliary information for noninvasive auxiliary screening and front-line triage before gastroscopic confirmation in CAG. The present results support further validation rather than immediate clinical implementation. External validation in independent, multicenter, and preferably prospective screening cohorts is needed to assess the model’s generalizability, screening performance, and potential clinical utility.
6.Reactive and Enzyme-activated Probe Strategies for Imaging Acute Kidney Injury
Ru-Long CHEN ; Ting-Fei XIE ; Jin-Xin ZHANG ; Jia-Ting CHEN ; Jie LI ; Peng-Fei ZHANG ; Ji-Hong CHEN ; Lin-Tao CAI
Progress in Biochemistry and Biophysics 2026;53(6):1622-1637
Acute kidney injury (AKI) is a prevalent and life-threatening clinical syndrome characterised by a rapid decline in renal function and diverse pathological etiologies. The condition has been demonstrated to be associated with elevated mortality rates and an increased risk of progression to chronic kidney disease. At present, clinicians depend heavily on conventional functional markers, such as serum creatinine and urine output, for the diagnosis and staging of the disease. It is evident that these conventional indicators characteristically manifest a considerable temporal delay and only undergo modification subsequent to considerable tissue damage. This severely restricts the timeframe for early detection and timely therapeutic intervention. Furthermore, standard markers fail to provide specific biological information regarding the underlying cellular injury mechanisms. The utilisation of advanced probe technologies in molecular imaging offers a robust alternative to overcome these inherent diagnostic limitations.This comprehensive review systematically evaluates recent progress in the design and application of two primary categories of molecular imaging tools for acute kidney disease, specifically reactive probes and enzyme-activated probes. Reactive probes are engineered to specifically interact with redox-active chemical species, including hydrogen peroxide, peroxynitrite, hypochlorous acid, and sulfur dioxide. Because oxidative stress constitutes a primary early event in acute renal tubular damage, these probes enable researchers and clinicians to visualize early cellular injury and radical accumulation well before global renal functional decline becomes evident. We discuss the application of these reactive probes across multiple imaging modalities including fluorescence imaging, magnetic resonance imaging (MRI), positron emission tomography (PET), and photoacoustic techniques. Photoacoustic imaging combines high spatial resolution with deep tissue penetration and has successfully demonstrated the ability to provide diagnostic alerts up to 12 h before any detectable rise in serum creatinine levels. Additionally, specific reactive probes have shown promising translational potential when tested by high-throughput screening in clinical human urine samples. Enzyme-activated probes target the specific catalytic activity of disease-relevant enzymes. These include well-documented renal tubular structural biomarkers such as NAG, GGT, and ALP, along with apoptosis-related caspases and specific nitroreductases. By responding only to enzymatic cleavage, these tools provide highly specific and pathology-directed imaging readouts. Recent structural design strategies in this field have advanced significantly beyond single-enzyme detection. Researchers are now focusing on sophisticated dual-target recognition to minimize background noise, multimodal integration to cross-validate imaging signals, and theranostic applications where probes simultaneously deliver diagnostic feedback and therapeutic agents to injured tissues. Nanotechnology serves as a fundamental enabler for realizing these advanced probe functions. By precisely optimizing nanoparticle parameters such as hydrodynamic size, surface charge, and targeting ligands, researchers can achieve amplified signal output, highly precise kidney delivery, and protection against premature degradation in the systemic circulation. For example, modifying surface charges can significantly enhance the active uptake of nanoprobes by damaged renal tubular epithelial cells.While preclinical probe development has progressed rapidly, moving these technologies into routine clinical practice remains a major challenge. We analyze the translational feasibility and current obstacles from biological, technological, and regulatory perspectives. Although biological targets such as KIM-1, FAP, and ALP have been validated in extensive patient cohorts, practical barriers severely limit their immediate clinical application. These obstacles involve complex changes in in vivo pharmacokinetics. During an acute injury episode, the extreme drop in the glomerular filtration rate alters probe clearance and can cause unwanted systemic accumulation or confusing background imaging signals. Other major hurdles include a lack of comprehensive long-term toxicity data and the absence of standardized manufacturing protocols to ensure batch-to-batch consistency. Future successful translation will require rigorous multi-center clinical studies to confirm the true diagnostic value of these probes over traditional markers. Researchers must also establish strict standardization of imaging procedures and comprehensive safety evaluations. Ultimately, this review provides a thorough reference framework for designing clinically translatable molecular probes and building a precision diagnostic imaging system for acute kidney injury.
7.The first record of Anopheles messeae (Diptera: Culicidae) parasitized by water mites in China
Xue-ru CHEN ; Wen-zhen YAO ; Yu-hao LI ; Gui-chang LI ; Tao MENG ; Qun-ling FENG ; Xin-hui LIU ; Li-hong QIAO ; Xiang-ting WU ; Xue-feng ZHANG ; Cheng-lin LI ; Xue-cheng DONG ; Da-wei WANG ; Xiao-yan SI ; Yu-hong GUO
Acta Parasitologica et Medica Entomologica Sinica 2026;33(1):53-57
Objective This study reports on the obligatory parasitism of water mites Arrenurus sp. on Anopheles messeae at the Manzhouli Port, Inner Mongolia, China. Methods Duing July 2024, a survey on the mosquito diversity was conducted at the Manzhouli Port. Captured mosquitoes and their ectoparasites were identified to species level. Results A total of 1840 adult mosquitoes were collected, representing species from three genera: Culex(Cx. modestus, Cx. pipiens pallens), Aedes(Ae. dorsalis, Ae. flavidorsalis, Ae. flavescens), and Anopheles (An. messeae). Among all the mosqutioes specimens,3 out of 150 captured An. messeae were found to carry ectoparasitic mites, with number of 2,4,27 mites separately. Morphological and molecular identification reached the same result as water mites(Hydrachnidiae, Hydracrina). COI gene sequence showed 94% similarity with the closest species Arrenurus truncatellus. Conlusions Literature review suggests water mites are host-specific parasitism of mosquito species and herein with the first record of Arrenurus sp. parasiting on An. Messeae in the most high-latitude region globally.
8.High Expression of INF2 Predicts Poor Prognosis and Promotes Hepatocellular Carcinoma Progression
Hai-Biao WANG ; Man LIN ; Fu-Sang YE ; Jia-Xin SHI ; Hong LI ; Meng YE ; Jie WANG
Progress in Biochemistry and Biophysics 2025;52(1):194-208
ObjectiveINF2 is a member of the formins family. Abnormal expression and regulation of INF2 have been associated with the progression of various tumors, but the expression and role of INF2 in hepatocellular carcinoma (HCC) remain unclear. HCC is a highly lethal malignant tumor. Given the limitations of traditional treatments, this study explored the expression level, clinical value and potential mechanism of INF2 in HCC in order to seek new therapeutic targets. MethodsIn this study, we used public databases to analyze the expression of INF2 in pan-cancer and HCC, as well as the impact of INF2 expression levels on HCC prognosis. Quantitative real time polymerase chain reaction (RT-qPCR), Western blot, and immunohistochemistry were used to detect the expression level of INF2 in liver cancer cells and human HCC tissues. The correlation between INF2 expression and clinical pathological features was analyzed using public databases and clinical data of human HCC samples. Subsequently, the effects of INF2 expression on the biological function and Drp1 phosphorylation of liver cancer cells were elucidated through in vitro and in vivo experiments. Finally, the predictive value and potential mechanism of INF2 in HCC were further analyzed through database and immunohistochemical experiments. ResultsINF2 is aberrantly high expression in HCC samples and the high expression of INF2 is correlated with overall survival, liver cirrhosis and pathological differentiation of HCC patients. The expression level of INF2 has certain diagnostic value in predicting the prognosis and pathological differentiation of HCC. In vivo and in vitro HCC models, upregulated expression of INF2 triggers the proliferation and migration of the HCC cell, while knockdown of INF2 could counteract this effect. INF2 in liver cancer cells may affect mitochondrial division by inducing Drp1 phosphorylation and mediate immune escape by up-regulating PD-L1 expression, thus promoting tumor progression. ConclusionINF2 is highly expressed in HCC and is associated with poor prognosis. High expression of INF2 may promote HCC progression by inducing Drp1 phosphorylation and up-regulation of PD-L1 expression, and targeting INF2 may be beneficial for HCC patients with high expression of INF2.
9.Application of Recombinant Collagen in Biomedicine
Huan HU ; Hong ZHANG ; Jian WANG ; Li-Wen WANG ; Qian LIU ; Ning-Wen CHENG ; Xin-Yue ZHANG ; Yun-Lan LI
Progress in Biochemistry and Biophysics 2025;52(2):395-416
Collagen is a major structural protein in the matrix of animal cells and the most widely distributed and abundant functional protein in mammals. Collagen’s good biocompatibility, biodegradability and biological activity make it a very valuable biomaterial. According to the source of collagen, it can be broadly categorized into two types: one is animal collagen; the other is recombinant collagen. Animal collagen is mainly extracted and purified from animal connective tissues by chemical methods, such as acid, alkali and enzyme methods, etc. Recombinant collagen refers to collagen produced by gene splicing technology, where the amino acid sequence is first designed and improved according to one’s own needs, and the gene sequence of improved recombinant collagen is highly consistent with that of human beings, and then the designed gene sequence is cloned into the appropriate vector, and then transferred to the appropriate expression vector. The designed gene sequence is cloned into a suitable vector, and then transferred to a suitable expression system for full expression, and finally the target protein is obtained by extraction and purification technology. Recombinant collagen has excellent histocompatibility and water solubility, can be directly absorbed by the human body and participate in the construction of collagen, remodeling of the extracellular matrix, cell growth, wound healing and site filling, etc., which has demonstrated significant effects, and has become the focus of the development of modern biomedical materials. This paper firstly elaborates the structure, type, and tissue distribution of human collagen, as well as the associated genetic diseases of different types of collagen, then introduces the specific process of producing animal source collagen and recombinant collagen, explains the advantages of recombinant collagen production method, and then introduces the various systems of expressing recombinant collagen, as well as their advantages and disadvantages, and finally briefly introduces the application of animal collagen, focusing on the use of animal collagen in the development of biopharmaceutical materials. In terms of application, it focuses on the use of animal disease models exploring the application effects of recombinant collagen in wound hemostasis, wound repair, corneal therapy, female pelvic floor dysfunction (FPFD), vaginal atrophy (VA) and vaginal dryness, thin endometritis (TE), chronic endometritis (CE), bone tissue regeneration in vivo, cardiovascular diseases, breast cancer (BC) and anti-aging. The mechanism of action of recombinant collagen in the treatment of FPFD and CE was introduced, and the clinical application and curative effect of recombinant collagen in skin burn, skin wound, dermatitis, acne and menopausal urogenital syndrome (GSM) were summarized. From the exploratory studies and clinical applications, it is evident that recombinant collagen has demonstrated surprising effects in the treatment of all types of diseases, such as reducing inflammation, promoting cell proliferation, migration and adhesion, increasing collagen deposition, and remodeling the extracellular matrix. At the end of the review, the challenges faced by recombinant collagen are summarized: to develop new recombinant collagen types and dosage forms, to explore the mechanism of action of recombinant collagen, and to provide an outlook for the future development and application of recombinant collagen.
10.Junctophilin-2 MORN-Helix Domain: Structural Basis for Membrane Binding and Hypertrophic Cardiomyopathy-associated Mutations
Jing-Xin WANG ; Zhi-Wei LI ; Wei LIU ; Wen-Qing ZHANG ; Jian-Chao LI
Progress in Biochemistry and Biophysics 2025;52(8):2103-2116
ObjectiveJunctophilin-2 (JPH2) is an essential structural protein that maintains junctional membrane complexes (JMCs) in cardiomyocytes by tethering the plasma membrane to the sarcoplasmic reticulum, thereby facilitating excitation-contraction (E-C) coupling. Mutations in JPH2 have been associated with hypertrophic cardiomyopathy (HCM), but the molecular mechanisms governing its membrane-binding properties and the functional relevance of its membrane occupation and recognition nexus (MORN) repeat motifs remain incompletely understood. This study aimed to elucidate the structural basis of JPH2 membrane association and its implications for HCM pathogenesis. MethodsA recombinant N-terminal fragment of mouse JPH2 (residues1-440), encompassing the MORN repeats and an adjacent helical region, was purified under near-physiological buffer conditions.X-ray crystallography was employed to determine the structure of the JPH2 MORN-Helix domain. Sequence conservation analysis across species and junctophilin isoforms was performed to assess the evolutionary conservation of key structural features. Functional membrane-binding assays were conducted using liposome co-sedimentation and cell-based localization studies in COS7 and HeLa cells. In addition, site-directed mutagenesis targeting positively charged residues and known HCM-associated mutations, including R347C, was used to evaluate their effects on membrane interaction and subcellular localization. ResultsThe crystal structure of the mouse JPH2 MORN-Helix domain was resolved at 2.6 Å, revealing a compact, elongated architecture consisting of multiple tandem MORN motifs arranged in a curved configuration, forming a continuous hydrophobic core stabilized by alternating aromatic residues. A C-terminal α-helix further reinforced structural integrity. Conservation analysis identified the inner groove of the MORN array as a highly conserved surface, suggesting its role as a protein-binding interface. A flexible linker segment enriched in positively charged residues, located adjacent to the MORN motifs, was found to mediate direct electrostatic interactions with negatively charged phospholipid membranes. Functional assays demonstrated that mutation of these basic residues impaired membrane association, while the HCM-linked R347C mutation completely abolished membrane localization in cellular assays, despite preserving the overall MORN-Helix fold in structural modeling. ConclusionThis study provides structural insight into the membrane-binding mechanism of the cardiomyocyte-specific protein JPH2, highlighting the dual roles of its MORN-Helix domain in membrane anchoring and protein interactions. The findings clarify the structural basis for membrane targeting via a positively charged linker and demonstrate that disruption of this interaction—such as that caused by the R347C mutation—likely contributes to HCM pathogenesis. These results not only enhance current understanding of JPH2 function in cardiac E-C coupling but also offer a structural framework for future investigations into the assembly and regulation of JMCs in both physiological and disease contexts.


Result Analysis
Print
Save
E-mail