1.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
2.Construction of Organoid-on-a-chip and Its Applications in Biomedical Fields
Rui-Xia LIU ; Jing ZHANG ; Xiao LI ; Yi LIU ; Long HUANG ; Hong-Wei HOU
Progress in Biochemistry and Biophysics 2026;53(2):293-308
Organoid-on-a-chip technology represents a promising interdisciplinary advancement that merges two cutting-edge biomedical platforms: stem cell-derived organoids and microfluidics-based organ-on-a-chip systems. Organoids are self-organizing three-dimensional (3D) cell cultures that mimic the key structural and functional features of in vivo organs. However, traditional organoid culture systems are often static, lacking dynamic environmental cues and suffering from limitations such as batch-to-batch variability, low stability, and low throughput. Organ-on-a-chip platforms, by contrast, utilize microfluidic technologies to simulate the dynamic physiological microenvironment of human tissues and organs, enabling more controlled cell growth and differentiation. By integrating the advantages of organoids and organ-on-a-chip technologies, organoid-on-a-chip systems transcend the limitations of conventional 3D culture models, offering a more physiologically relevant and controllable in vitro platform. In organoid-on-a-chip systems, stem cells or pre-formed organoids are cultured in micro-engineered environments that mimic in vivo conditions, enabling precise control over fluid flow, mechanical forces, and biochemical cues. Specifically, these platforms employ advanced strategies including bio-inspired 3D scaffolds for structural support, precise spatial cell patterning via 3D bioprinting, and integrated biosensors for real-time monitoring of metabolic activities. These synergistic elements recreate complex extracellular matrix signals and ensure high structural fidelity. Based on structural complexity, organoid-on-a-chip systems are classified into single-organoid and multi-organoid types, forming a trajectory from unit biomimicry to systemic simulation. Single-organoid chips focus on highly biomimetic units by integrating vascular, immune, or neural functions. Multi-organoid chips simulate inter-organ crosstalk and systemic homeostasis, advancing complex disease modeling and PK/PD evaluation. This emerging technology has demonstrated broad application potential in multiple fields of biomedicine. Organoid-on-a-chip systems can recapitulate organ developmentin vitro, facilitating research in developmental biology. They mimic organ-specific physiological activities and mechanisms, showing promising applications in regenerative medicine for tissue repair or replacement. In disease modeling, they support the reconstruction of models for neurodegenerative, inflammatory, infectious, metabolic diseases, and cancers. These platforms also enable in vitro drug testing and pharmacokinetic studies (ADME). Patient-derived chips preserve genetic and pathological features, offering potential for precision medicine. Additionally, they reduce species differences in toxicology, providing human-relevant data for environmental, food, cosmetic, and drug safety assessments. Despite progress, organoid-on-a-chip systems face challenges in dynamic simulation, extracellular matrix (ECM) variability, and limited real-time 3D imaging, requiring improved materials and the integration of developmental signals. Current bottlenecks also include the high technical threshold for automation and the lack of standardized validation frameworks for regulatory adoption. Meanwhile, the concept of a “human-on-a-chip” has been proposed to mimic whole-body physiology by integrating multiple organoid modules. This approach enables systemic modeling of drug responses and toxicity, with the potential to reduce animal testing and revolutionize drug development. Future advancements in bio-responsive hydrogels and flexible biosensors will further empower these platforms to bridge the gap between bench-side research and personalized clinical interventions. In conclusion, organoid-on-a-chip technology offers a transformative in vitro model that closely recapitulates the complexity of human tissues and organ systems. It provides an unprecedented platform for advancing biomedical research, clinical translation, and pharmaceutical innovation. Continued development in biomaterials, microengineering, and analytical technologies will be essential to unlocking the full potential of this powerful tool.
3.Study on the construction of a red blood cell rare blood type database and physical repository in the Guangzhou Region
Zhijian LIAO ; Shuangshuang JIA ; Yuan SHAO ; Boquan HUANG ; Chunyan MO ; Jizhi WEN ; Runqing ZHANG ; Xia RONG ; Hong LUO ; Huaqin LIANG ; Yanli JI
Chinese Journal of Blood Transfusion 2026;39(5):619-628
Objective: To conduct screening for rare blood types within important blood group systems for the Chinese population, such as Rh, Duffy, Kidd, P1Pk, Diego, and MNS, in the Guangzhou region, and to establish a corresponding rare blood type database and physical repository. Methods: The saline medium microplate method was used to screen blood donors with the ccDEE phenotype combined with either Jk(a-) or Jk(b-). The polybrene microplate method was employed to screen for donors with Fy(a-), s(-), Lu(b-), Di(b-), k(-), and p phenotypes. The urea lysis microplate method was applied to screen for the Jk(a-b-) phenotype. A high-resolution melting (HRM) curve method was established for screening some donors with the Di(b-) phenotype. Subsequently, expanded phenotyping of antigens in the Rh, Kidd, MNS, Duffy, P1Pk, Lewis, Kell, and Lutheran blood group systems was performed on identified rare blood type donors using monoclonal antibodies. The test results are entered into the Rare Blood Type Bank Management System of the Guangzhou Blood Center, enabling functions such as confirmation reminders and cryopreservation storage when the donor donates again. Red blood cells of rare blood types are processed into frozen red blood cells for long-term storage. Results: Among voluntary blood donors, 16 cases of the ccDEE combined with Jk(a-) phenotype were identified (0.221 7%, 16/7 216); 10 cases of the ccDEE combined with Jk(b-) phenotype (0.138 6%, 10/7 216); 78 cases of the Fy(a-) phenotype (0.169 5%, 78/46 012); 39 cases of the Lu(b-) phenotype (0.138 2%, 39/28 214); 31 cases of the s(-) phenotype (0.081 8%, 31/37 913); 22 cases of the Di(b-) phenotype (0.029 9%, 22/73 691); 30 cases of the Jk(a-b-) phenotype (0.010 1%, 30/298 250); and 1 case of the k(-) phenotype (0.001 3%, 1/77 382), which was further identified as KELnull phenotype (K0). No p phenotype donors were identified (0/88 528). A total of 228 units of frozen red blood cells were prepared. The screening results were compared and analyzed with rare blood type data from other regions. Conclusion: This study, through a combination of different screening methods, significantly improved the efficiency of rare blood type screening while remaining cost-effective. By conducting large-scale screening and performing data informatization processing, a database and physical repository of rare blood types in the Guangzhou region were successfully established. This provides a strong guarantee for the timely supply of blood to patients with difficult-to-match and rare blood types in the region, effectively enhances the level of transfusion safety in the region, and offers a practical paradigm for constructing a comprehensive blood transfusion support system.
4.Expert consensus on imaging diagnosis and analysis of early correction of childhood malocclusion.
Zitong LIN ; Chenchen ZHOU ; Ziyang HU ; Zuyan ZHANG ; Yong CHENG ; Bing FANG ; Hong HE ; Hu WANG ; Gang LI ; Jun GUO ; Weihua GUO ; Xiaobing LI ; Guangning ZHENG ; Zhimin LI ; Donglin ZENG ; Yan LIU ; Yuehua LIU ; Min HU ; Lunguo XIA ; Jihong ZHAO ; Yaling SONG ; Huang LI ; Jun JI ; Jinlin SONG ; Lili CHEN ; Tiemei WANG
International Journal of Oral Science 2025;17(1):21-21
Early correction of childhood malocclusion is timely managing morphological, structural, and functional abnormalities at different dentomaxillofacial developmental stages. The selection of appropriate imaging examination and comprehensive radiological diagnosis and analysis play an important role in early correction of childhood malocclusion. This expert consensus is a collaborative effort by multidisciplinary experts in dentistry across the nation based on the current clinical evidence, aiming to provide general guidance on appropriate imaging examination selection, comprehensive and accurate imaging assessment for early orthodontic treatment patients.
Humans
;
Malocclusion/diagnostic imaging*
;
Child
;
Consensus
5.Association of Body Mass Index with All-Cause Mortality and Cause-Specific Mortality in Rural China: 10-Year Follow-up of a Population-Based Multicenter Prospective Study.
Juan Juan HUANG ; Yuan Zhi DI ; Ling Yu SHEN ; Jian Guo LIANG ; Jiang DU ; Xue Fang CAO ; Wei Tao DUAN ; Ai Wei HE ; Jun LIANG ; Li Mei ZHU ; Zi Sen LIU ; Fang LIU ; Shu Min YANG ; Zu Hui XU ; Cheng CHEN ; Bin ZHANG ; Jiao Xia YAN ; Yan Chun LIANG ; Rong LIU ; Tao ZHU ; Hong Zhi LI ; Fei SHEN ; Bo Xuan FENG ; Yi Jun HE ; Zi Han LI ; Ya Qi ZHAO ; Tong Lei GUO ; Li Qiong BAI ; Wei LU ; Qi JIN ; Lei GAO ; He Nan XIN
Biomedical and Environmental Sciences 2025;38(10):1179-1193
OBJECTIVE:
This study aimed to explore the association between body mass index (BMI) and mortality based on the 10-year population-based multicenter prospective study.
METHODS:
A general population-based multicenter prospective study was conducted at four sites in rural China between 2013 and 2023. Multivariate Cox proportional hazards models and restricted cubic spline analyses were used to assess the association between BMI and mortality. Stratified analyses were performed based on the individual characteristics of the participants.
RESULTS:
Overall, 19,107 participants with a sum of 163,095 person-years were included and 1,910 participants died. The underweight (< 18.5 kg/m 2) presented an increase in all-cause mortality (adjusted hazards ratio [ aHR] = 2.00, 95% confidence interval [ CI]: 1.66-2.41), while overweight (≥ 24.0 to < 28.0 kg/m 2) and obesity (≥ 28.0 kg/m 2) presented a decrease with an aHR of 0.61 (95% CI: 0.52-0.73) and 0.51 (95% CI: 0.37-0.70), respectively. Overweight ( aHR = 0.76, 95% CI: 0.67-0.86) and mild obesity ( aHR = 0.72, 95% CI: 0.59-0.87) had a positive impact on mortality in people older than 60 years. All-cause mortality decreased rapidly until reaching a BMI of 25.7 kg/m 2 ( aHR = 0.95, 95% CI: 0.92-0.98) and increased slightly above that value, indicating a U-shaped association. The beneficial impact of being overweight on mortality was robust in most subgroups and sensitivity analyses.
CONCLUSION
This study provides additional evidence that overweight and mild obesity may be inversely related to the risk of death in individuals older than 60 years. Therefore, it is essential to consider age differences when formulating health and weight management strategies.
Humans
;
Body Mass Index
;
China/epidemiology*
;
Male
;
Female
;
Middle Aged
;
Prospective Studies
;
Rural Population/statistics & numerical data*
;
Aged
;
Follow-Up Studies
;
Adult
;
Mortality
;
Cause of Death
;
Obesity/mortality*
;
Overweight/mortality*
6.Glucocorticoid Discontinuation in Patients with Rheumatoid Arthritis under Background of Chinese Medicine: Challenges and Potentials Coexist.
Chuan-Hui YAO ; Chi ZHANG ; Meng-Ge SONG ; Cong-Min XIA ; Tian CHANG ; Xie-Li MA ; Wei-Xiang LIU ; Zi-Xia LIU ; Jia-Meng LIU ; Xiao-Po TANG ; Ying LIU ; Jian LIU ; Jiang-Yun PENG ; Dong-Yi HE ; Qing-Chun HUANG ; Ming-Li GAO ; Jian-Ping YU ; Wei LIU ; Jian-Yong ZHANG ; Yue-Lan ZHU ; Xiu-Juan HOU ; Hai-Dong WANG ; Yong-Fei FANG ; Yue WANG ; Yin SU ; Xin-Ping TIAN ; Ai-Ping LYU ; Xun GONG ; Quan JIANG
Chinese journal of integrative medicine 2025;31(7):581-589
OBJECTIVE:
To evaluate the dynamic changes of glucocorticoid (GC) dose and the feasibility of GC discontinuation in rheumatoid arthritis (RA) patients under the background of Chinese medicine (CM).
METHODS:
This multicenter retrospective cohort study included 1,196 RA patients enrolled in the China Rheumatoid Arthritis Registry of Patients with Chinese Medicine (CERTAIN) from September 1, 2019 to December 4, 2023, who initiated GC therapy. Participants were divided into the Western medicine (WM) and integrative medicine (IM, combination of CM and WM) groups based on medication regimen. Follow-up was performed at least every 3 months to assess dynamic changes in GC dose. Changes in GC dose were analyzed by generalized estimator equation, the probability of GC discontinuation was assessed using Kaplan-Meier curve, and predictors of GC discontinuation were analyzed by Cox regression. Patients with <12 months of follow-up were excluded for the sensitivity analysis.
RESULTS:
Among 1,196 patients (85.4% female; median age 56.4 years), 880 (73.6%) received IM. Over a median 12-month follow-up, 34.3% (410 cases) discontinued GC, with significantly higher rates in the IM group (40.8% vs. 16.1% in WM; P<0.05). GC dose declined progressively, with IM patients demonstrating faster reductions (median 3.75 mg vs. 5.00 mg in WM at 12 months; P<0.05). Multivariate Cox analysis identified age <60 years [P<0.001, hazard ratios (HR)=2.142, 95% confidence interval (CI): 1.523-3.012], IM therapy (P=0.001, HR=2.175, 95% CI: 1.369-3.456), baseline GC dose ⩽7.5 mg (P=0.003, HR=1.637, 95% CI: 1.177-2.275), and absence of non-steroidal anti-inflammatory drugs use (P=0.001, HR=2.546, 95% CI: 1.432-4.527) as significant predictors of GC discontinuation. Sensitivity analysis (545 cases) confirmed these findings.
CONCLUSIONS
RA patients receiving CM face difficulties in following guideline-recommended GC discontinuation protocols. IM can promote GC discontinuation and is a promising strategy to reduce GC dependency in RA management. (Trial registration: ClinicalTrials.gov, No. NCT05219214).
Adult
;
Aged
;
Female
;
Humans
;
Male
;
Middle Aged
;
Arthritis, Rheumatoid/drug therapy*
;
Glucocorticoids/therapeutic use*
;
Medicine, Chinese Traditional
;
Retrospective Studies
7.In vitro and intracellular antibacterial activities of OPC-167832 against Mycobacterium fortuitum
Zhen-yan QI ; Xia YU ; Hai-rong HUANG ; Hong-fei DUAN
Chinese Journal of Zoonoses 2025;41(4):392-397
This study evaluated the potential of OPC-167832 as a new method for the treatment of Mycobacterium fortuitum infec-tion.Drug sensitivity tests were conducted with the broth microdilution method to determine the minimum inhibitory concentration(MIC)of OPC-167832 against standard strains of M.fortuitum and 44 clinical isolates of M.fortuitum.A DprE1 overexpression strain was constructed,and the effect in the MIC of OPC-167832 against M.fortuitum were explored.Intracellular germicidal tests and checkerboard tests were conducted to verify the ability of OPC-167832 to kill intracellular M.fortuitum,and its interaction with five drugs:amikacin,clarithromycin,imipenem,moxifloxacin,and clofazimine.The MIC50 and MIC90 against 44 clinical isolates of M.fortuitum were 0.031 25 μg/mL and 0.062 5μg/mL,respectively.The epidemiological cut-off value(ECOFF)was 0.062 5 μg/mL.Overexpression of DprE1 led to resistance to OPC-167832 in M.fortuitum.After 24 hours of incubation,the intracellular bacterial in-hibition rate of OPC-167832 at a 1 μg/mL concentration was 81.37%,exceeding the 74.05%inhibition rate of amikacin at a 1 μg/mL concentration.OPC-167832 showed strong inhibitory activity against M.fortuitum in vitro and in macrophages,and might provide a promising treatment for M.fortuitum infection.
8.Development and reliability and validity test of the Ego Depletion Scale for Type 2 Diabetes Patients
Jiaxin YOU ; Rong XU ; Tian XIA ; Haishan HUANG ; Xiao LU ; Hong LIU ; Yan HUANG ; Qinghua LIU ; Xuna BIAN
Chinese Journal of Nursing 2025;60(19):2371-2377
Objective To develop the Ego Depletion Scale for Type 2 Diabetes Patients and evaluate its reliability and validity,and to provide a specific assessment tool for evaluating ego-depletion in self-management.Methods Guided by the self-control strength model,the initial scale was constructed through literature review,semi-structured interviews,2 rounds of expert consultation,and a pilot survey.A convenience sampling method was employed to recruit 460 patients with Type 2 Diabetes from the endocrinology department of a tertiary hospital in Wuhan,Hubei Province,between April and July 2024.They were randomly divided into 2 subsets for exploratory factor analysis and confirmatory factor analysis.Results A total of 451 valid questionnaires were collected.Exploratory factor analysis extracted 6 common factors,with a cumulative variance contribution of 73.231%.In confirmatory factor analysis,an item was deleted due to failing to meet the standardized loading value criterion.The revised Ego Depletion Scale for Type 2 Diabetes Patients comprised 6 dimensions and 22 items.The total Cronbach's α coefficient was 0.911;split-half reliability was 0.744;the content validity index was 0.860.Correlation coefficients between the total score and scores of each dimension of the scale and the total score of the Self-Regulatory Fatigue Scale ranged from 0.558 to 0.946(P<0.001).Conclusion The scale exhibits robust reliability and validity,serving as a scientifically instrument for assessing ego depletion in patients with Type 2 Diabetes.
9.Risk factors and development of a prediction model of enteral feeding intolerance in critically ill children.
Xia ZHOU ; Hong-Mei GAO ; Lin HUANG ; Hui-Wu HAN ; Hong-Ling HU ; You LI ; Ren-He YU
Chinese Journal of Contemporary Pediatrics 2025;27(3):321-327
OBJECTIVES:
To explore the risk factors of feeding intolerance (FI) in critically ill children receiving enteral nutrition (EN) and to construct a prediction nomogram model for FI.
METHODS:
A retrospective study was conducted to collect data from critically ill children admitted to the Pediatric Intensive Care Unit of Xiangya Hospital, Central South University, between January 2015 and October 2020. The children were randomly divided into a training set (346 cases) and a validation set (147 cases). The training set was further divided into a tolerance group (216 cases) and an intolerance group (130 cases). Multivariate logistic regression analysis was used to screen for risk factors for FI in critically ill children receiving EN. A nomogram was constructed using R language, which was then validated on the validation set. The model's discrimination, calibration, and clinical net benefit were evaluated using receiver operating characteristic curves, calibration curves, and decision curves.
RESULTS:
Duration of bed rest, shock, gastrointestinal decompression, use of non-steroidal anti-inflammatory drugs, and combined parenteral nutrition were identified as independent risk factors for FI in critically ill children receiving EN (P<0.05). Based on these factors, a nomogram prediction model for FI in critically ill children receiving EN was developed. The area under the receiver operating characteristic curve for the training set and validation set was 0.934 (95%CI: 0.906-0.963) and 0.852 (95%CI: 0.787-0.917), respectively, indicating good discrimination of the model. The Hosmer-Lemeshow goodness-of-fit test showed that the model had a good fit (χ 2=12.559, P=0.128). Calibration curve and decision curve analyses suggested that the model has high predictive efficacy and clinical application value.
CONCLUSIONS
Duration of bed rest, shock, gastrointestinal decompression, use of non-steroidal anti-inflammatory drugs, and combined parenteral nutrition are independent risk factors for FI in critically ill children receiving EN. The nomogram model developed based on these factors exhibits high predictive efficacy and clinical application value.
Humans
;
Critical Illness
;
Enteral Nutrition/adverse effects*
;
Male
;
Risk Factors
;
Female
;
Child, Preschool
;
Infant
;
Nomograms
;
Retrospective Studies
;
Child
;
Logistic Models
10.Value of targeted next-generation sequencing in pathogen detection for neonates with respiratory distress syndrome: a prospective randomized controlled trial.
Hai-Hong ZHANG ; Xia OU-YANG ; Xian-Ping LIU ; Shao-Ru HUANG ; Yun-Feng LIN
Chinese Journal of Contemporary Pediatrics 2025;27(10):1191-1198
OBJECTIVES:
To investigate the application value of targeted next-generation sequencing (tNGS) in the etiological diagnosis of moderate to severe respiratory distress syndrome (RDS) in neonates.
METHODS:
A prospective randomized controlled trial was conducted, enrolling 81 term and late-preterm neonates with moderate to severe RDS admitted to Fujian Children's Hospital between December 2023 and December 2024. Patients were randomly assigned to the conventional microbiological test (CMT) group (n=42) or the tNGS group (n=39). For routine pathogen detection, bronchoalveolar lavage fluid was obtained via bronchoscopy, and lower respiratory tract specimens were collected via the endotracheal tube; all specimens underwent culture, and some specimens additionally underwent polymerase chain reaction or antigen testing. In the tNGS group, tNGS was performed in addition to routine pathogen detection on the same specimen types. The detection rate of pathogens, the detection rate of co-infections, and the duration of antibiotic use were compared between the two groups.
RESULTS:
The pathogen detection rate in the tNGS group (18/39, 46%) was significantly higher than that in the CMT group (8/42, 19%) (P=0.009). The co-infection detection rate was 13% (5/39) in the tNGS group, while no co-infections were identified in the CMT group (P=0.024). Regarding treatment, the duration of antibiotic use in the tNGS group was shorter than that in the CMT group [(12±4) days vs (15±5) days, P=0.003].
CONCLUSIONS
tNGS significantly improves the pathogen detection rate in neonates with moderate to severe RDS and offers advantages in the rapid identification of co-infections and reduction of antibiotic treatment duration, suggesting it has clinical utility and potential for wider adoption.
Humans
;
Prospective Studies
;
Infant, Newborn
;
Female
;
Respiratory Distress Syndrome, Newborn/etiology*
;
Male
;
High-Throughput Nucleotide Sequencing/methods*

Result Analysis
Print
Save
E-mail